• Title/Summary/Keyword: Intra-motion

Search Result 211, Processing Time 0.021 seconds

A Study on an Improved H.264 Inter mode decision method (H.264 인터모드 결정 방법 개선에 관한 연구)

  • Gong, Jae-Woong;Jung, Jae-Jin;Hwang, Eui-Sung;Kim, Tae-Hyoung;Kim, Doo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.245-252
    • /
    • 2008
  • In this paper, we propose a new method for improving the H 264 encoding process and motion estimation part. Our approach is a method to reduce the encoding running time through the omission of reference frame in the mode selection process of H 264 and an improvement of SAD computing process. To evaluate the proposed method, we used the H 264 standard image of QCIF size and TIN 4:2:0 format. Experimental results show that proposed SAD algorithm 1 can improve the speed of encoding runnung time by an average of 4.7% with a negligible degradation of PSNR. However, SAD algorithm 2 can improve the speed of encoding runnung time by an average of 9.6% with 0.98dB degradation of PSNR.

  • PDF

Anterolateral Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Using an Anterolateral Locking Plate (원위 경골 골절에서 전외측 잠김 금속판을 사용한 전외측 최소 침습적 금속판 고정술)

  • Suh, Dongwhan;Lee, Hwan Hee;Han, Young Hoon;Jeong, Jae Jung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.24 no.1
    • /
    • pp.19-24
    • /
    • 2020
  • Purpose: Anterolateral minimally invasive plate osteosynthesis (MIPO) was performed to treat patients with distal tibial fractures associated with open fractures or extensive soft tissue injuries, which is limited medial MIPO. The treatment results of the anterolateral MIPO technique were evaluated and analyzed. Materials and Methods: Seventeen patients with distal tibial fractures associated with an open fracture or large bullae formation on the distal tibia medial side were treated with anterolateral MIPO using anterolateral locking plates. Within 24 hours of visiting the emergency room, external fixation was applied, and the medial side wound was managed. After damage control, the anterolateral locking plate was applied using an anterolateral MIPO technique. The union time, nonunion, or malunion were evaluated with regular postoperative radiographs. The ankle range of motion, operative time, blood loss, Iowa score, and wound complications were investigated. Results: Radiological evidence of bony union was obtained in all cases. The mean time to union was 16.7 weeks (12~25 weeks). The mean operation time was 44.0 minutes. Regarding the ankle range of motion, the mean dorsiflexion was 15°, and the mean plantarflexion was 35°. Satisfactory results were obtained in 15 out of 17 cases; five results were classified as excellent, four were good, and six were fair. The mean blood loss was 125.2 mL. Two complications were recorded. Conclusion: In distal tibial fractures with severe medial soft tissue damage caused by high-energy trauma, the staged anterolateral MIPO technique using anterolateral locking plates is a useful alternative treatment to achieving optimal wound care, rapid union with biological fixation, and intra-articular reduction.

An Efficient H.264/AVC Encoding Using GOP Based Adaptive Inter Prediction (GOP 기반의 적응적 인터 예측을 이용한 다시점 비디오의 효율적인 H.264/AVC 부호화)

  • Lee, Jung-Ho;Cho, Ik-Hwan;Lee, Woong-Ho;Jeong, Dong-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12C
    • /
    • pp.1224-1231
    • /
    • 2006
  • This paper proposes a fast encoding algorithm of H.264/AVC multi-view video coding. The amount of data to be encoded for a multi-view video is much more than normal video's data, and the amount of information to be predicted is enormous because of the multi-view video coding uses inter-disparity prediction in addition to inter-motion prediction in conventional video coding. We noticed through an experiment that the efficiency of prediction is getting better in order of intra, inter-disparity, inter-motion, and inter-skip, and proposes a early termination algorithm by means of estimate the adaptive threshold within a GOP unit. In the experiments, the proposed algorithm shows improved processing speed about 32% compared to existing method, and increased amount of bits and distortions are relatively disregardable.

The reliability of the nonradiologic measures of thoracic spine rotation in healthy adults

  • Hwang, Donggi;Lee, Ju Hyeong;Moon, Seongyeon;Park, Soon Woo;Woo, Juha;Kim, Cheong
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Objective: The purpose of this study was to examine the intertester reliability and validity of four nonradiologic measurements of thoracic spine rotation in healthy adults. Design: Descriptive laboratory study. Methods: This study was conducted on 20 male and 20 female university students aged between 19 and 26. To measure thoracic rotation, a goniometer, a bubble inclinometer, a dual inclinometer, and a smartphone application-clinometer were used. The measurement was performed twice for each device and the same measurement was performed by two examiners. The measurements were performed in the lumbar locked position. The arm in the direction of rotation was taken back and placed onto the back of the lumbar region. With right and left trunk rotation, the head was rotated together but remained in the center line so that the axial rotation was maintained. Both examiners performed the measuring procedures and directly handled the measuring instrument. All measurement results were recorded by the recorder. Results: The range of motion (ROM) of thoracic rotation in lumbar locked position for all four devices was 47 degrees. The intra-rater reliability estimates ranged from 0.738 to 0.906 (p<0.05). The inter-rater reliability estimates ranged from 0.736 to 0.853 (p<0.05). The goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer showed high validity (p<0.05). This result indicates that all four devices may be used by the same examiner and by other examiners obtaining follow-up measurement. Conclusions: The use of the goniometer, bubble inclinometer, dual inclinometer, and smartphone clinometer for measurements in the lumbar locked posture are reliable and valid nonradiologic measures of thoracic rotational ROM in healthy adults.

Can manipulation under anesthesia alone provide clinical outcomes similar to arthroscopic circumferential capsular release in primary frozen shoulder (FS)?: the necessity of arthroscopic capsular release in primary FS

  • Lee, Seung-Jin;Jang, Jun-Hyuk;Hyun, Yoon-Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.169-177
    • /
    • 2020
  • Background: We evaluated the need for arthroscopic capsular release (ACR) in refractory primary frozen shoulder (FS) by comparing clinical outcomes of patients treated with ACR and manipulation under anesthesia (MUA). Methods: We assessed patients with refractory primary FS, 57 patients (group A) who were treated with MUA and 22 patients (group B) who were treated with ACR. In group A, manipulation including a backside arm-curl maneuver was performed under interscalene brachial block. In group B, manipulation was performed only to release the inferior capsule before arthroscopic circumferential capsular release, which was carried out for the unreleased capsule after manipulation. Pain, range of shoulder motion, and American Shoulder and Elbow Surgeons score were recorded at 1 week, 3 months, 6 months, and 1 year after surgery. We compared outcome variables between treatment groups and between diabetics and non-diabetics and also evaluated the numbers of patients receiving additional intra-articular steroid injection. Results: Outcome variables at 3 months after surgery and improvements in outcome variables did not differ between groups. Group A showed significantly better results than group B in the evaluation of pain and range of motion at 1 week. Diabetics showed comparable outcomes to non-diabetics for most variables. Eleven patients required additional steroid injections between 8 to 16 weeks after surgery: 12.2% in group A, 18.2% in group B. Additional injections were given three times more often in diabetics compared to non-diabetics. Conclusions: MUA alone can yield similar clinical outcomes to ACR in refractory FS.

Short-term comparative outcomes between reverse shoulder arthroplasty for shoulder trauma and shoulder arthritis: a Southeast Asian experience

  • Ng, Julia Poh Hwee;Tham, Sherlyn Yen Yu;Kolla, Saketh;Kwan, Yiu Hin;Tan, James Chung Hui;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.210-216
    • /
    • 2022
  • Background: Reverse shoulder arthroplasty (RSA), first introduced as a management option for cuff tear arthropathy, is now an accepted treatment for complex proximal humeral fractures. Few studies have identified whether the outcomes of RSA for shoulder trauma are comparable to those of RSA for shoulder arthritis. Methods: This is a retrospective, single-institution cohort study of all patients who underwent RSA at our institution between January 2013 and December 2019. In total, 49 patients met the inclusion criteria. As outcomes, we evaluated the 1-year American Shoulder and Elbow Surgeons (ASES) and Constant shoulder scores, postoperative shoulder range of motion, intra- and postoperative complications, and cumulative revision rate. The patients were grouped based on preoperative diagnosis to compare postoperative outcomes across two broad groups. Results: The median follow-up period was 32.8 months (interquartile range, 12.6-66.6 months). The 1-year visual analog scale, range of motion, and Constant and ASES functional scores were comparable between RSAs performed to treat shoulder trauma and that performed for arthritis. The overall complication rate was 20.4%, with patients with a preoperative diagnosis of arthritis having significantly more complications than those with a preoperative diagnosis of trauma (34.8% vs. 7.7%). Conclusions: Patients who underwent RSA due to a proximal humeral fracture or dislocation did not fare worse than those who underwent RSA for arthritis at 1 year, in terms of both functional and radiological outcomes.

Effects of Combined Cervical Stabilization and Stretching Exercises on Craniovertebral Angle, Respiration, Disability, and Range of Motion in Office Workers with Forward Head Posture : A Randomized Control Trial

  • Kim, Kyung;Kang, Na-Yeon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.3
    • /
    • pp.13-25
    • /
    • 2022
  • Purpose : The purpose of this study was to investigate the effects of combined cervical stabilization exercise (CSE) and stretching exercise (SE) on office workers with forward head posture (FHP). Methods : A total of 32 office workers with forward head posture were randomly assigned to experimental (n=16) and control (n=16) groups. The experimental group underwent combined CSE and SE, and the control group underwent cervical self-myofascial release and SE. Both groups performed exercises for 40 min per day, thrice per week for a total of 6 weeks. Craniovertebral angle (CVA), respiration, disability, and joint range of motion (ROM) before and 6 weeks after intervention were measured and compared. Results : There was no significant between-group difference in the general characteristics (p>.05). The intra-group comparison showed significant differences in the visual analog scale (VAS) and neck disability index (NDI) of both groups post-intervention (p<.05). CVA and forced expiratory volume in 1 seconds (FEV1) were significantly improved post-intervention in the experimental group only (p<.05). In the experimental group, all ROM variables were significantly improved post-intervention. In contrast, in the control group, all ROM variables improved significantly post-intervention, except for extension (p<.05). The inter-group comparison showed significant differences in NDI, left lateral flexion, right lateral flexion, and left rotation between the two groups (p<.05). Conclusion : The combination of CSE and SE, which stabilizes the cervical spine, had positive effects on cranial rotation angle, respiration, disability, and joint ROM in office workers with forward head posture. Therefore, the combination of the two exercises may be an effective option to reduce symptoms and prevent postural problems in office workers with FHP.

A Study on Motion Estimator Design Using DCT DC Value (DCT 직류 값을 이용한 움직임 추정기 설계에 관한 연구)

  • Lee, Gwon-Cheol;Park, Jong-Jin;Jo, Won-Gyeong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.3
    • /
    • pp.258-268
    • /
    • 2001
  • The compression method is necessarily used to send the high quality moving picture that contains a number of data in image processing. In the field of moving picture compression method, the motion estimation algorithm is used to reduce the temporal redundancy. Block matching algorithm to be usually used is distinguished partial search algorithm with full search algorithm. Full search algorithm be used in this paper is the method to compare the reference block with entire block in the search window. It is very efficient and has simple data flow and control circuit. But the bigger the search window, the larger hardware size, because large computational operation is needed. In this paper, we design the full search block matching motion estimator. Using the DCT DC values, we decide luminance. And we apply 3 bit compare-selector using bit plane to I(Intra coded) picture, not using 8 bit luminance signals. Also it is suggested that use the same selective bit for the P(Predicted coded) and B(Bidirectional coded) picture. We compare based full search method with PSNR(Peak Signal to Noise Ratio) for C language modeling. Its condition is the reference block 8$\times$8, the search window 24$\times$24 and 352$\times$288 gray scale standard video images. The result has small difference that we cannot see. And we design the suggested motion estimator that hardware size is proved to reduce 38.3% for structure I and 30.7% for structure II. The memory is proved to reduce 31.3% for structure I and II.

  • PDF

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Chronic Lateral Ankle Instability (만성 외측 발목 불안정)

  • Kim, Dae-Wook;Sung, Ki-Sun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.2
    • /
    • pp.55-61
    • /
    • 2018
  • Chronic lateral ankle instability is a major complication of acute ankle sprains, which can cause discomfort in both daily and sports activity. In addition, it may result in degenerative changes to the ankle joint in the long term. An accurate diagnostic approach and successful treatment plan can be established based on a comprehensive understanding of the concept of functional and mechanical instability. The patients' history and correct physical examination would be the first and most important step. The hindfoot alignment, competence of the lateral ligaments, and proprioceptive function should be evaluated. Additional information can be gathered using standard and stress radiographs. In addition, concomitant pathologic conditions can be investigated by magnetic resonance imaging. Conservative rehabilitation composed of the range of motion, muscle strengthening, and proprioceptive exercise is the main treatment for functional instability and mechanical instability. Regarding the mechanical instability, surgical treatment can be considered for irresponsible patients after a sufficient period of rehabilitation. Anatomic repair (modified $Brostr{\ddot{o}}m$ operation) is regarded as the gold standard procedure. In cases with poor prognostic factors, an anatomical reconstruction or additional procedures can be chosen. For combined intra-articular pathologies, arthroscopic procedures should be conducted, and arthroscopic lateral ligament repair has recently been introduced. Regarding the postoperative management, early functional rehabilitation with short term immobilization is recommended.