• Title/Summary/Keyword: Intra-cavity

Search Result 82, Processing Time 0.026 seconds

Dependence of Mode Locked Yb-doped Fiber Laser Output on the Size of the Beam Incident upon a Semiconductor Saturable Absorber Mirror (반도체 포화 흡수체 거울에 입사되는 광의 크기에 따른 모드 잠금된 Yb 첨가된 광섬유 레이저 출력 특성)

  • Moon, Dong Joon;Kim, Myung Jin;Ahan, Cheol Yong;Kim, Nam Seong;Kim, Hyun Su
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.3
    • /
    • pp.103-107
    • /
    • 2012
  • We investigate the dependence of the output of a mode locked Yb-doped fiber laser on incident intra-cavity intensity on a semiconductor saturable absorber mirror (SESAM). To vary the incident intra-cavity intensity, we change the beam spot size on a SESAM by varying the focal length of a lens installed in the front of the SESAM.

Two Cases of Infantile Intra-abdominal Inflammatory Myofibroblastic Tumor

  • Kim, Soo-Hong;Cho, Yong Hoon;Kim, Hae Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.17 no.2
    • /
    • pp.116-120
    • /
    • 2014
  • Inflammatory myofibroblastic tumor (IMT) is rare mesenchymal solid tumor that consists of proliferating myofibroblasts with an inflammatory infiltrate background. It has a very low prevalence in infants and occurs mainly in children and young adults. IMT are mainly located in the thoracic cavity, but intra-abdominal lesions are rare. IMT can exhibit locally aggressive neoplastic processes and metastases similar to malignancies, so, have clinical importance. Herein, we describe two infantile intra-abdominal IMT cases presenting with incidentally found palpable abdominal mass. A 4-month-old male infant had IMT at the ileal mesentery and a 5-month-old male infant had IMT at liver. Both cases were successfully treated by complete surgical resection without complication or recurrence. Considering the biological behavior of the intermediate type of neoplasm in IMT, we expect good survivals when achieving appropriate surgical resection without adjuvant therapy in infantile intra-abdominal IMT.

Effect of local anesthetics on pulpal blood flow in mechanically stimulated teeth

  • Chu, Wan-Sik;Park, Jeong-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.596-596
    • /
    • 2003
  • The purpose of this study were to evaluate the effect of epinephrine-containing local anesthetics on pulpal blood flow (PBF) and to compare the change of pulpal blood flow after cavity preparation between in non-anesthetized teeth and in anesthetized ones in cats. Nine cats were initially anesthetized with intra-muscular injection of keramine(75mg/kg) and acepromazine(2.5mg/kg). Periapical radiographs of canine teeth were taken, followed by intra-venous injection of alpha-chloralose(40mg/kg) and urethane (500mg/kg) through the femoral vein for the general anesthesia.(중략)

  • PDF

Characteristics of the Sealing Pressure of a Magnetic Fluid Shaft Seal for Intra-Cardiac Axial Flow Blood Pumps (심장 내 이식형 축류 혈액 펌프용 자성 유체 축봉의 내압 특성)

  • KIM, Dong-Wook;Mitamura , Yoshinori
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.10
    • /
    • pp.477-482
    • /
    • 2002
  • One of the key technologic requirements for rotary blood pumps is the sealing of the motor shaft. A mechanical seal, a journal bearing, magnetic coupling, and magnetic suspension have been developed, but they have drawbacks such as wear, thrombus formation, and power consumption. A magnetic fluid seal is durable, simple, and non power consumptive. Long-term experiments confirmed these advantages. The seal body was composed of a Nd-Fe-B magnet and two pole pieces; the seal was formed by injecting magnetic fluid into the gap (50${\mu}m$) between the pole pieces and the motor shaft. To contain the ferro-fluid in the seal and to minimize the possibility of magnetic fluid making contact with blood, a shield with a small cavity was attached to the pole piece. While submerged in blood, the sealing pressure of the seal was measured and found to be 31kPa with magnetic fluid LS-40 (saturated magnetization, 24.3 KA/m) at a motor speed of 10,000 rpm and 53kPa under static conditions(0mmHg). The specially designed magnetic fluid seal for keeping liquids out is useful for axial flow blood pumps. The magnetic fluid seal was incorporated into an intra-cardiac axial flow blood pump.

A Huge Intra-Abdominal Mass Associated with Long-Term Surgical Gauze Retention in a Toy Breed Dog

  • Lee, Sung-Jun;Jeong, Soon-Wuk;Eom, Ki-Dong;Shin, Jong-Il;Yoon, Hun-Young
    • Journal of Veterinary Clinics
    • /
    • v.33 no.2
    • /
    • pp.116-121
    • /
    • 2016
  • A 1.83 kg, 9-year-old, spayed female Yorkshire Terrier was referred to the Veterinary Medical Teaching Hospital of Konkuk University for evaluation of an intra-abdominal mass with a week history of vomiting and diarrhea. On physical examination, survey radiography, abdominal ultrasonography, and computed tomography, a huge firm mass was identified in the mid-caudal abdomen. Surgical exploration of the abdominal cavity was performed to remove the mass. The encapsulated mass adhered to the mesentery, tail of the spleen, small intestine, omentum, and right lobe of the pancreas was removed using blunt dissection with dry gauze and cotton swabs. Macroscopic and histopathological examination revealed that the mass was foreign-body granuloma consistent with gauze fiber. Plain abdominal radiography demonstrated no remarkable findings 8 months post-operatively. There was no evidence of vomiting, diarrhea, coughing, difficulty breathing, and cyanosis on exertion 13 months post-operatively.

Participation of IL-1β in temporomandibular nociception in rats with CFA-induced inflammation

  • Ju, Jin-Sook;Choi, Seung-Ho;Kim, Hye-Jin;Son, Jo-Young;Ahn, Dong-Kuk
    • International Journal of Oral Biology
    • /
    • v.41 no.3
    • /
    • pp.125-131
    • /
    • 2016
  • The aim of the present study was to develop an animal model for evaluation of temporomandibular (TMJ) nociception under TMJ inflammation. We also investigated the participation of $IL-1{\beta}$ in inflammation-induced TMJ nociception. Experiments were carried out using male Sprague-Dawley rats. Intra-articular injection of 3% formalin was administered to evaluate hyperalgesia 3 days after CFA injection. Intra-articular injection of 3% formalin did not produce nociceptive behavior in normal rats. Although intra-articular injection of 3 doses of CFA produced TMJ inflammation, only 1:3 diluted CFA produced hyperalgesia when formalin was injected intra-articularly 3 days after CFA injection. Co-administration of IL-1 receptor inhibitor with formalin into the TMJ cavity 3 days after CFA injection was performed. Co-administration of IL-1 receptor inhibitor significantly inhibited formalin-induced hyperalgesia in rats with CFA-induced TMJ inflammation. These results suggested that intra-articular injection of formalin produced hyperalgesia under chronic TMJ inflammation. Moreover, $IL-1{\beta}$ plays an important role in TMJ hyperalgesia under chronic inflammation and blockade of $IL-1{\beta}$ is a potential therapeutic target for inflammatory TMJ pain.

A Study of Radiation Dose Evaluation and Optimization Methods for Intra Oral Dental X-ray in Pediatric Patient (소아 구내촬영 시 방사선량 평가 및 최적화 방안에 대한 연구)

  • Lee, Hyun-Yong;Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.195-203
    • /
    • 2021
  • Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.

Medical Image Registration Methods for Intra-Cavity Surgical Robots (인체 공동 내부 수술용 로봇을 위한 이미지 레지스트레이션 방법)

  • An, Jae-Bum;Lee, Sang-Yoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.140-147
    • /
    • 2007
  • As the use of robots in surgeries becomes more frequent, the registration of medical devices based on images becomes more important. This paper presents two numerical algorithms for the registration of cross-sectional medical images such as CT (Computerized Tomography) or MRI (Magnetic Resonance Imaging) by using the geometrical information from helix or line fiducials. Both registration algorithms are designed to be used for a surgical robot that works inside a cavity of human body. This paper also reports details about the fiducial pattern that includes four helices and one line. The algorithms and the fiducial pattern were tested in various computer-simulated situations, and the results showed excellent overall registration accuracy.

Wavelength-Tunable, Passively Mode-Locked Erbium-Doped Fiber Master-Oscillator Incorporating a Semiconductor Saturable Absorber Mirror

  • Vazquez-Zuniga, Luis A.;Jeong, Yoonchan
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.117-129
    • /
    • 2013
  • We briefly review the recent progress in passively mode-locked fiber lasers (PMLFLs) based on semiconductor saturable absorber mirrors (SESAMs) and discuss the detailed characterization of a SESAM-based, passively mode-locked erbium-doped fiber (EDF) laser operating in the 1.5-${\mu}m$ spectral range for various configurations. A simple and compact design of the laser cavity enables the PMLFL to generate either femtosecond or wavelength-tunable picosecond pulses with high stability as the intra-cavity filtering method is altered. All the cavities investigated in our experiments present self-starting, continuous-wave mode-locking with no Q-switching instabilities. The excellent stability of the source eventually enables the wavelength-tunable PMLFL to be used as a master oscillator for a power-amplifier source based on a large-core EDF, generating picosecond pulses of >10-kW peak power and >100-nJ pulse energy.

Arthroscopy Assisted 2 Cannulated Screw Fixation for Transverse Glenoid Fracture: A Case Report

  • Park, Sam-Guk
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.2
    • /
    • pp.105-109
    • /
    • 2016
  • Arthroscopy is recognized as an important adjunct in treatment of intra-articular fractures. The author reports on successful treatment of a displaced transverse glenoid cavity fracture, reduced and fixed with arthroscopic assist, using two cannulated screws perpendicular to the fracture surface, in a patient with frail chest. One screw passed through the Neviaser portal, and the other screw passed through the base of the coracoid process. Arthroscopy assisted reduction and 2 cannulated screw fixation through the Neviaser portal and coracoid base appears to be a good method for treatment of transverse glenoid fractures.