• Title/Summary/Keyword: Intra-cavity

Search Result 82, Processing Time 0.02 seconds

Fiber Ring Laser Intra-cavity Absorption Spectroscopy for Gas Sensing: Analysis and Experiment

  • Li, Mo;Liu, Kun;Jing, Wencai;Peng, Gang-Ding
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.14-21
    • /
    • 2010
  • Fiber ring laser based intra-cavity absorption spectroscopic sensor has great potential for high sensitivity gas detection. Using the rate equations and propagation equations, we investigated theoretically factors that affect the sensitivity of such fiber ring laser sensors and determined the optimal design parameters and conditions for significant enhancement of the system sensitivity. Experiments have been conducted to determine the sensitivity enhancement performance. The results showed a factor of 25 ~ 30 in sensitivity enhancement in the experimental system, agreeing well with the theoretical expectations. Experiments on acetylene detection have also been carried out and the results showed that the ring cavity significantly increases the signal absorption and that high sensitivity can be obtained for gas detection.

The Musculoskeletal Pain and Inconvenient Feeling During Hand Instruments with Mannequin and Intra-oral Cavity in Dental Hygiene Students (치위생학과 학생들의 구강 내와 마네킹에서 기구 조작시 근골격계 통증과 불편감)

  • Yoo, Jae-Hae;Ro, Hyo-Lyun;Lee, Min-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.4
    • /
    • pp.247-254
    • /
    • 2008
  • Purpose : The purpose of this study was to analyze some factors that can cause incidence of the muscle and skeletal system trouble, by which Dental Hygiene Students examine the pain and the inconvenient feeling according to kinds in manual implements and the usability in the level of manipulating and maintaining the manual implement, in the actual training of the intra oral cavity along with mannequin given the scaling practice. Methods : Targeting 18 female juniors for the department of dental hygiene, who had directly practiced oral prophylaxis for 2 years, the questionnaire research was carried out right after the mutual practice in the intra oral cavity along with mannequin. Results : It was indicated that there is no big difficulty both in intra oral cavity and mannequin in terms of manipulating implement with a method of maintaining the rightly hand fixing or of grasping the trans formative pencil and of controlling force given manipulating the implement. How to grasp a trans formative pencil was indicated to be more difficult in the intra-oral manipulation(p<.05). Pain and inconvenient-feeling level, which occur in muscle and skeletal system during practicing the scaling in mannequin, were indicated to be in order of shoulder, wrist, neck, waist, elbow, and headache. Conclusion : There was no big difference in the pain and the inconvenient feeling in muscle and skeletal system according to mannequin and intra-oral environment given manipulating tile manual implement. However, there was difference in manipulating the implement with a method of grasping transformative pencil. The pain and inconvenient feeling in muscle and skeletal system were the highest both in shoulder and wrist.

  • PDF

The legal status of the breast in assessing physical disability (신체장애 평가에서 유방의 법적 지위 - 장기 해당 여부, 수유장애, 노동력상실에 대하여 -)

  • Kim, Bong Kyum
    • The Korean Society of Law and Medicine
    • /
    • v.18 no.1
    • /
    • pp.265-295
    • /
    • 2017
  • Breast tissue is composed of skin, mammary gland(including lactiferous duct), subcutaneous fat layer. The anatomical position is on the anterior chest wall(the outside of the chest cavity) but not on the inside of the thorax. Therefore, when the internal organs in the thoracic cavity are defined and expressed as 'organs' and the internal organs of each are labeled for a long time, for the breast located outside the thoracic cavity, it is thought that there is considerable difficulty in defining and recognizing the breast tissue as organs. For this reason, it is necessary to discourage the controversy over whether or not the breast is contained in the chest(or intra-thoracic cavity). In order to completely exclude it, it is assumed that the "chest-abdomen" can be called the "intra-thoraxic or intra-abdominal." But it is difficult to change the terms in various laws and regulations, I think that it would be necessary to insert only the clue clause "Breasts are excluded" in the detailed criteria for grading. In order to include it, it is necessary to change the terms of the ordinance or to say that the breast is exceptionally included.

  • PDF

Wideband Flat Optical Frequency Comb Generated from a Semiconductor Based 10 GHz Mode-Locked Laser with Intra-cavity Fabry-Perot Etalon

  • Leaird, Daniel E.;Weiner, Andrew M.;Seo, Dongsun
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.19-24
    • /
    • 2014
  • We report stable, wideband, flat-topped, 10 GHz optical frequency comb generation from a semiconductor-based mode-locked ring laser with an intra-cavity high finesse Fabry-Perot etalon. We demonstrate a stable 10 GHz comb with greater than 200 lines within a spectral power variation below 1 dB, which is the largest value obtained from a similar mode-locked laser in our knowledge. Greater than 20 dB of the spectral peak to deep ratio at 0.02 nm resolution, ~92 femtosecond timing jitter over 1 kHz to 1 MHz range, and non-averaged time traces of pulses confirm very stable optical frequency comb lines.

Factors Affecting Postoperative Complication in Pneumonectomy for Chronic Complicated Inflammatory Lung Disease (만성 염증성 폐질환의 전폐적축술 후 합병증에 영향을 미치는 요인)

  • 최필조;우종수
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.73-78
    • /
    • 2000
  • Background: this study was designed to estimate whether specific risk factors could increase the postoperative complication rate of pneumonectomy for chronic complicated inf-lammatory lung disease. Material and Method: Eighty-five patients underwent pneumon-ectomy for chronic complicated inflammatory lung disease(tuberculosis, 67 ; bronchiecasis 11; aspergio- losis, 4; others, 3) between January 1991 and August 1998. We performed a univariated statistical analysis to identify preoperative and intraoperative risk factors associated with postoperative complications, Result: There was no operative mortality. There were a total of 18 postoperative complications(22.2%) Bronchopleural fistula(BPF) and empyema occurred in 5(5.9%) and 2(2.4%) respectively. General complication rate was significantly higher in patients with right-sided pneumonectomy(p=.029) extrapleural pneu-monectomy(p=.009) and intraoperative pleural spillage due to cavity or lesion perforation (p=.004). The prevalence of BPF and empyema was higher in patients with right sided pneumonectomy(p=.007) extrapleural pneumonectomy(p=.015) and intraoperative pl- eural spillage due to cavity or lesion perforation(p=.003) which is as the same results as gen-eral complication rate. Conclusion: The postoperative complication rate of pneumone-ctomy for chronic complicated lung disease is accptably low. But it is increase in patients with right sided pneumonectomy extrapleural pneumonectomy and intraoperative pleural spillage due to cavity or lesion perforation. therefore more careful and meticulous intra-operatve management are needed in right sided extrapleural pneumonectomy without intra- pleural spillage.

  • PDF

A Case of Intra-Abdominal Esophageal Duplication Cyst (복강 내에 위치한 식도 중복성 낭종 1례)

  • Chung, Ju-Young;Park, Dong-Chul
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.224-227
    • /
    • 2001
  • Esophageal duplication cysts are quite uncommon benign lesions of the esophagus that have previously been described as occurring only in the thoracic cavity. We experienced a rare case of completely intra-abdominal esophageal duplication cyst in a 10-year-old boy who has suffered from epigastric abdominal pain. Surgical excision is recommended at the time of cyst discovery whether symptoms present or not.

  • PDF

Local Application of NK1 Receptor Antagonists and Pulpal Blood Flow in Cat

  • Kim, Young-Kyung;Chu, Wan-Sik;Lee, Ho-Jeong;Ahn, Dong-Kuk;Yoo, Hyun-Mi;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.239-248
    • /
    • 2004
  • The purpose of this study was to investigate the influence of NK1 receptor antagonists on the pulpal blood flow (PBF) when applied iontophoretically through the dentinal cavity of the teeth in order to understand whether iontophoretically applied NK1 receptor antagonists can control the pulpal inflammation. Eleven cats were anesthetized with alpha-chloralose and urethane, and substance P (SP) was administered to the dental pulp through the catheterized lingual artery in doses that caused PBF change without the influence of systemic blood pressure. NK1 receptor antagonists were applied iontophoretically to the prepared dentinal cavity of ipsilateral canine teeth of the drug administration, and PBF was monitored. Data were analyzed statistically with paired t-test. PBF increase after iontophoretic application of the NK1 receptor antagonists followed by the intra-arterial administration of SP was significantly less than PBF increase after iontophoretic application of the 0.9% saline followed by the intra-arterial administration of SP as a control (p < 0.05). Iontophoretic application of the NK1 receptor antagonists (0.2~3.4 mM) following the intra-arterial administration of SP resulted in less increase of PBF than the iontophoretic application of the 0.9% saline following the intra-arterial administration of SP as a control (p < 0.05). Therefore. the results of the present study provide evidences that the iontophoretic application is an effective method to deliver drugs to the dental pulp. and that iontophoretically applied NK1 receptor antagonists block SP-induced vasodilation effectively. The above results show the possibility that the iontophoretical application of NK1 receptor antagonists can control the neurogenic inflammation in the dental pulp.

The Patient Care During Before Radiotherapy in Oral Cavity Cancer (구강내 종양환자의 방사선 치료시의 Patient Care)

  • Jeon Byeong-chul;Park Jae-il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.92-96
    • /
    • 1995
  • All patients who will Undergo irraidiation of the oral cavity cancer will need dental before and during Radiotherapy. The extent of the region and the presence of numerous critical normal tissues(mucosa, gingiva, teeth and the alveolar ridge, alveolar bony structure, etc) in the oral cavity area, injury to which could result in serious functional impairment. Therefore I evaluate the Usefulness of custom-made intraoral shielding device before and during Radiotherapy in oral cavity cancer. Materials and Methods(1) : Manufacture process of Custom-made intraoral shielding device Containing Cerroband. A. Acquisition of impression B. Matrix Constitution C. Separation by Separator D. Sprincle on method E. Trimming F. Spacing G. Fill with Cerroband Materials and Methods (2) A. Preannealing B. TLD Set up C. Annealing D. TLD Reading = Results = Therefore dosimetric characteristics in oral cavity by TLD Compared to isodose curve dose distribution Ipsilateral oral mucosa, Contralateral oral mucosa, alveolar ridge, tongue, dose was reduced by intraoral shielding device containning Cerroband technique Compard to isodose plan = Conclusions = The custom-made intra-oral shielding device containing Cerroband was useful in reducing the Contralateral oral mucosa dose and Volume irradiated.

  • PDF

Quasi-Continuous Operation of 1.55- μm Vertical-Cavity Surface-Emitting Lasers by Wafer Fusion

  • Song, Dae-Sung;Song, Hyun-Woo;Kim, Chang-Kyu;Lee, Young-Hee;Kim, Jung-Su
    • Journal of the Optical Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.83-89
    • /
    • 2001
  • Room temperature quasi-continuous operation is achieved near 1556 nm with threshold current as low as 2.2 mA from a 5.6-${\mu}{\textrm}{m}$ oxide-aperture vertical-cavity surface-emitting laser. Wafer fusion techniques are employed to combine the GaAs/AlGaAs mirror and the InP-based InGaAs/InGaAsP active layer. In this structure, an $Al_x/O_y$/GaAs distributed bragg reflector and intra-cavity contacts are used to reduce free carrier absorption.