• 제목/요약/키워드: Interventricular space

검색결과 7건 처리시간 0.022초

심실간 공간 압력을 이용한 이동작동기형 완전이식 인공심장에서의 좌, 우심방압 추정 (Relationship between atrial pressures and the interventricular pressure in the moving actuator type total artificial heart)

  • 조영호;최원우;박성근;최재순;이종진;엄경식;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.88-90
    • /
    • 1996
  • The right and left atrial pressures are important parameters in automatic control of a total artificial heart (TAH) within normal physiological ranges. Our TAH is composed of a moving actuator, right and left ventricles and the interventricular space enclosed by a semi-rigid housing. During operation of the TAH, the jnterventpicular space's volume is changed dynamically by the difference between the ejection volume of one ventricle and the inflow volume of the other. Therefore, the changes in pressure of the interventricular space is related to both atrial pressures. We measured the interventricular pressure (IVP) waveform using a pressure sensor and attempted to indirectly estimate the changes of atrial pressures. This method has an advantage that the sensor does not contact the blood directly. Furthermore, the IVP waveforms have its zero baseline in each pump cycle, thus the pressure measurements are free from the transducer drift problems by measuring the peak pressure from these baseline values. From the In vitro experiments, we found that the IVP waveform contained several useful parameters such as negative peak, dP/dT on the initial break, the area enclosed by the profile in each stroke, which are associated with atrial pressures and the filling conditions of the ventricles. The measured atrial pressures were linearly related to the negative peak of the interventricular pressure.

  • PDF

A Simplified Model for Compliance Determination of the Moving-Actuator Type Totally Implantable Artificial Heart

  • 박성근;최원우;안재목;김수정;최재순;조영호;엄경식;이종진;김희찬;최민주;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.82-83
    • /
    • 1996
  • In this paper, we present a simplified model for complicance determination of the moving-actuator type totally implantable artificial heart (TAH). The modeling equations are derived from the mechanics and geometry of the TAH components. The interventricular pressure and volume are computed for determining the compliance of the interventricular space using this model. The model is capable of generating realistic hemodynamic variables such as the left atrial pressure and interventricular pressure and is proved to be acceptable. This model can be used as an initial step for analyzing characteristics of the moving-actuator type TAH.

  • PDF

말에서 흉복부의 초음파상 (Ultrasonographic Evaluation of the Thorax and Abdomen in Horse)

  • 김명철;변홍섭;신상태;김용준;이경광;한용만
    • 한국임상수의학회지
    • /
    • 제15권1호
    • /
    • pp.14-21
    • /
    • 1998
  • Ultrasonogram for kidney, spleens liver, intestine and heart was evaluated 11 Chriu horses and 14 Thoroughbred horse. The kidney was determined at both flan and both 17th intercostal spaces. The spleen was determined at the left 13-17 intercom spacer and the liver was determined at the right 7-13 intercostal space. The heart was determined at the right 4-6 intercostal space and left 3-6 intercostal space. The length, of rig kidney at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 16.2, 12.6, 13.1 and 11.2 mm, respectively. The width of right kidney at the Thoroughbed horse, Thorughbred foul, Cheju horse and Cheju foul were 5.4, 4.3, 4.6 and 4.2 mm, respectively. The depth of right kidney at the Thoroughbred horsed Thoroughbred foul, Cheju horse and Chrju foul were 5.2, 4.4, 4.5 and 4.3 mm, respectively. Similar ultrasonographic measurements were obtained for the left kidney, The left ventricular end-diastolic diameter at the Thoroughbred horse, Thoroughbred fouls Cheju horst and Cheju foul were 107, 83, 85 and 73 mm, respectively. The left ventricular end-systolic diameter were at the Thoroughbred horse, Thoroughbred foul, Cheiu horse and Cheiu foul were 63, 52, 53 and 45 mm, respectively. Also, the interventricular septum in end-diastole, interventricular septum in end-systoles left ventricular wall end-diastoles left ventricular wall end-systoles right ventricular end-diastole diameter, aorta and left atrium at t Thoroughbred horse, Thoroughbred foul, Chriu horse and Chriu foul were measured. Experimental renal stone and enterolith of colon were observed by ultrasonography.

  • PDF

완전이식형 인공심장의 좌,우 심박출량 균형의 개선에 관한 연구 (A New Method for Enhancement of Right-Left Pump Output Balance in the Totally Implantable Artificial Heart)

  • 최원우;김희찬;김원곤;노준량;김인영;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권4호
    • /
    • pp.385-391
    • /
    • 1998
  • 이동형 작동기 방식의 완전이식형 인공심장을 대상으로 부가적인 체적보상실(compliance chamber)이 필요없는 새로운 균형적 심방압 유지방법을 개발하였다. 이동작동기으 lqleocld 원주운동을 통하여 좌우심박출의 균형을 유지할 수 있었으며, 두 시실 사이의 공간에 존재하는 공기가 심박출량 차이를 보상하도록 고안되었다. 인공심장 표면이 가변적인 부분은 좌우 심박출량의 균형 보상을 도와주게 된다. 그러나 인공심장 표면의 가변성을 높일 경우, 전체 심박출량의 감소를 유발할 수 있다. 본 논문에서는 두 심실사의 공기량을 조절하여 좌우 심박출량의 균형 및 전체 심박량에 대하여 좋은 조건을 모의 순환 실험을 통하여 결정하였다. 새로운 인공심장은 63kg의 양에 이식하여 3일간 생존하였으며, 생존기간중 평균심박출량은 4.21/min 이었으며, 심방압은 15mmHg 이하로 유지되었다.

  • PDF

완전이식형 인공심장의 심방압 균형성능의 개선에 관한 연구 (A Study On the Improvement of Atrial Pressures Balancing Performance of Total Artificial Heart)

  • 최원우;박성근;조영호;최재순;이동준;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.216-218
    • /
    • 1995
  • A new atrial pressures balancing method for moving actuator total artificial heart(TAH) without an extra compliance chamber is developed. The structural characteristics of the pendulous moving actuator have made it possible to compensate the left and right pump output difference by utilizing the interventricular air space as an internal compliance chamber in a pump housing. Furthermore, the balancing performance is increased through the improvement of the flexibility of part of the polyurathane housing. However, the increase of the flexibility of the housing causes a little loss of the cardiac output due to the reduction of active filling performance. In this paper, a good condition between the balance and pump output performance is evaluated by adjusting the air volume in the interventricular space through a series of in vitro experiment.

  • PDF

한우에서의 초음파화상진단에 관한 연구 (Fundamental Studies on the Ultrasonographic Diagnosis in Korean Native Cattle)

  • 김명철;박관호
    • 한국임상수의학회지
    • /
    • 제12권1호
    • /
    • pp.861-876
    • /
    • 1995
  • This study was carried out to get fundamental information about the normal ultrasonogram of the liver and heart in Korean native cattle and calves. The interventricular septum, left ventricular internal diameter, left ventricular free wall thickness, aortic diameter, left atrial diameter, and right ventricular internal diameter of hear in 10 Korean native calves were determined at 4-5 right intercostal spare by use of ultrasonography. The caudal vena cava, portal vein, gallbladder, liver of 9 Korean native cattle and 10 calves were determined at 12, 11 and 10th intercostal spares by use of ultrasonography. Cursor-directed M-mode and gray-scale, B-mode ultrasonograms were obtained with electronic scanning ultrasound equipment with a 3.5 or 5.0-MHz convex transducer. The results obtained through the experiments were summarized as follows: 1. The result of ultrasonographic examination of the korean native calves' heart 1) Interventricular septum in systole and diastole was 1.23 and 0.81 cm, respectively(vc=28.84, 17.4). 2) Ventricular internal diameter in systole and diastole was 2.50 and 4.91 cm, respectively(vc=17.44, 12.73). 3) Left ventricular free was thickness in systole and diastole was 1.44 and 0.92 cm, respectively(vc=26.85, 23.54). 4) Aortic diameter was 2.69.m, .rspectevely(vc=11.29). 5) Left atrial diameter was 1.82 cm(vc=15.31). 6) Right ventricular internal diameter in systole and diastole was 1.12 and 1.9 cm, respectively(vc=33.71, 24.43). 3. Ultrasonographic measurments of caudal vena cava, portal vein, gallbladder of Korean native calves 1) Dorsal margin of caudal vena cava at the 12, 11 and 10th intercostal space was 13.5, 15.3 and 18.1 cm, respectively(p<0.01). 3) Depth of caudal vena cava at the 12, 11 and 10th intercostal space was 4.4, 4.5 and 4.6 cm, respectively. 3) Diameter of caudal vena cava at the 12, 11 and 10th intercostal space was 11.6, 1.7 and 1.6 cm, respectively. 4) Dorsal margin of portal vein at the 12, 11 and 10th intercostal space was 16.2, 18.6 and 21.4 cm, respectively(p<0.01) 5) Depth of portal vein at the 12, 11 and 10th intercostal spare was 4.5, 4.4 and 3.9 cm respectively. 6) Diameter of portal vein at the 13, 11 and 10th intercostal space was 2.1, 2.2 and 1.9 cm respectively. 7) Dorsal margin of gallbladder at the 11 and 10th intercostal space was 23.6 and 23.9 cm, respectively(p<0.01), 8) Longitudinal diameter of gallbladder at the 11 and 10th intercostal space was 7.1 and 5.9 cm, respectively(p<0.05). 9) Transverse diameter of gallbladder at the 11 and 10th intercostal space was 2.4 and 2.1 cm respectively(p<0.01). 3. Ultrasonographic measurments of caudal vena cava, portal vein, gallbladder of Korean native cattle 1) Dorsal margin of caudal vena cava at the 12 and 11th intercostal space was 22.2, and 25.4 cm, respectively(p<0.01). 2) Depth of caudal vena cava at the 12 and 11th intercostal space was 103 and 11.1 cm, respectively(p<0.01). 3) Diameter of caudal vena cava at the 12 and 11th intercostal space was 3.1 and 3.0 cm, respectively. 4) Dorsal margin of portal vein at the 12 and 11th intercostal space was 29.3 and 32.9 cm, respectively(p<0.01). 5) Depth of portal vein at the 12 and 11th intercostal space was 9.6, and 9.2 cm, respectively. 6) Diameter of portal vein at the 12 and lith intercostal space was 3.4 and 3.3 cm, respectively. 7) Dorsal margin of gallbladder at the 11 and 10th intercostal space was 43.1 and 45.5 cm, respectively(p<0.01). 8) Longitudinal diameter of gallbladder at the 11 and 10th intercostal space was 10.1 and 9.4 cm, respectively. 9) Transverse diameter of gallbladder at the 11 and 10th intercostal space was 4.0 and 3.7 cm, respectively. 4, Ultrasonogaphic measurments of dorsal margin, ventral margin, size and angles of the Korean native calves' liver. 1) Dorsal margin of liver at the 12, 11 and 10th intercostal space was 11.0, 9.6, and 12.4 cm, respectively(p<0.01). 2) Ventral margin of liver at the 12, 11 and 10th intercostal spate was 20, 24 and 26.1 cm, respectively(p<0.01). 3) Size of the liver at the 12, 11 and 10th intercostal space was 9.0, 14.6 and 13.8 cm, respectively(p<0.01). 4) Angle of liver at the 12, 11 and 10th intercostal space was 40, 46 and 37, respectively(p<0.01). 5. Ultrasonographic measurmants of dorsal margin, ventral margin, size and anglses of the korean native cattle's liver 1) Dorsal margin of the liver at the 12, 11 and 10th intercostal space was 14.4, 18.2 and 26, 3 cm, respectively. 2) Ventral margin of liver at the 12, 11 and 10th intercostal space was 41.1, 46.4 and 49.3 cm, respectively(p<0.01). 3) Size of the liver at the 12, 11 and 10th intercostal space was 26.8, 28.2 and 23.2 cm, respectively(p<0.01). 4) Angel of liverat the 15, 11 and 10 intercostal space was 41, 40.6 and 35.7, respectively(p<0.05). It was concluded that the ultrasonographic values oletermined in this study can be used as references for the diagnosis of morphologic changes in the hear and liver in korean native calves, and in the liver in korean native rattle.

  • PDF

부분방실관의 교정수술 치험 1예 (Surgical Correction of Partial Atrioventricular Canal: One Case Report)

  • 이철범
    • Journal of Chest Surgery
    • /
    • 제14권1호
    • /
    • pp.49-59
    • /
    • 1981
  • This is one case report of surgically treated partial atrioventricular canal. The 22 year-old male patient had no definitive history of frequent respiratory infection and cyanosis in his early childhood. Since his age of 7 years, dyspnea was manifested on exertion. First appearance of congestive heart failure was at his age of 16 years old. The physical examination revealed that the neck veins were distended and heaving of precordium. A thrill was palpable on the left 3rd-4th intercostal space extending from the sternal border toward the apex and Grade IV/VI systolic ejection murmur was audible on it. Neither cyanosis nor clubbing was noted. Liver was palpable about 5 finger breadths. Chest X-ray revealed increased pulmonary vascularity and severe cardiomegaly (C-T ratio = 74%). EKG revealed LAD, clockwise rotation, LVH and trifascicular block. Echocardiogram showed paradoxical ventricular septal movement, narrowed left ventricular outflow tract and abnormal diastolic movement of the anterior leaflet of mitral valve. Right heart catheterization resulted in large left to right shunt (Qp : Qs = 5.7: 1), ASD and moderate pulfllonary hypertension. Finally, left ventriculogram revealed typical goose neck appearance of left ventrlcalar outflow tract. On Oct. 10, 1980, open heart surgery was performed. Operative findings were: 1. Large primum defect ($6{\times}5$ Cm in diameter) 2. Cleft on the anterior leaflet of mitral valve. 3. The upper portion of ventricular septum was descent but no interventricular communication. 4. Downward attachment of the atrioventricular valves on the ventricular muscular septum. 5. Medium sized secumdum defect ($2{\times}1$ Cm in diameter). The cleft was repaired with 4 interrupted sutures. The primum defect was closed with Teflon patch and the secundum defect was closed with direct suture closure. Postoperatively atrial flutter-fibrillation in EKG and Grade U/VI apical systolic murmur were found. The postoperative course was uneventful and discharged on 29th postoperative day in good general conditions.

  • PDF