• 제목/요약/키워드: Interstory drift

검색결과 69건 처리시간 0.024초

Limit states of RC structures with first floor irregularities

  • Favvata, Maria J.;Naoum, Maria C.;Karayannis, Chris G.
    • Structural Engineering and Mechanics
    • /
    • 제47권6호
    • /
    • pp.791-818
    • /
    • 2013
  • The seismic performance of reinforced concrete (RC) frame structures with irregularities leading to soft first floor is studied using capacity assessment procedures. The soft first story effect is investigated for the cases: (i) slab-column connections without beams at the first floor, (ii) tall first story height and (iii) pilotis type building (open ground story). The effects of the first floor irregularity on the RC frame structure performance stages at global and local level (limit states) are investigated. Assessment based on the Capacity Spectrum Method (ATC-40) and on the Coefficient Method (FEMA 356) is also examined. Results in terms of failure modes, capacity curves, interstory drifts, ductility requirements and infills behaviour are presented. From the results it can be deduced that the global capacity of the structures is decreased due to the considered first floor morphology irregularities in comparison to the capacities of the regular structure. An increase of the demands for interstory drift is observed at the first floor level due to the considered irregularities while the open ground floor structure (pilotis type) led to even higher values of interstory drift demands at the first story. In the cases of tall first story and slab-column connections without beams soft-story mechanisms have also been observed at the first floor. Rotational criteria (EC8-part3) showed that the structure with slab-column connections without beams exhibited the most critical response.

TS 제진공법으로 내진보강된 철근콘크리트 골조의 내진성능(Part 2:해석적 연구) (Seismic Performance of RC Frame System Retrofitted with TS Seismic Strengthening Method(Part 2:Analytical Study))

  • 정명철;송정원;송진규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.148-153
    • /
    • 2018
  • 본 연구에서는 TS 내진보강공법의 내진보강 효과 검증을 목적으로 7개의 지진파에 대한 TS 댐퍼(Tension Spring-Damper)로 내진보강된 구조물의 비선형 시간이력해석을 수행하였다. 비선형 시간이력 해석을 통해 얻어진 무보강 구조물의 층간변위비와 에너지소산 양과 비교한 결과 층간변위비가 약 30% 가량 감소하였고, 구조체를 통한 에너지 소산의 양은 반감되었다. 이를 통해 TS 내진보강공법의 제진성능이 우수함을 확인하였다.

Evaluation of seismic strengthening techniques for non-ductile soft-story RC frame

  • Karki, Prajwol;Oinam, Romanbabu M.;Sahoo, Dipti Ranjan
    • Advances in concrete construction
    • /
    • 제9권4호
    • /
    • pp.423-435
    • /
    • 2020
  • Open ground story (OGS) reinforced concrete (RC) buildings are vulnerable to the complete collapse or severe damages under seismic actions. This study investigates the effectiveness of four different strengthening techniques representing the local and global modifications to improve the seismic performance of a non-ductile RC OGS frame. Steel caging and concrete jacketing methods of column strengthening are considered as the local modification techniques, whereas steel bracing and RC shear wall systems are selected as the global strengthening techniques in this study. Performance-based plastic design (PBPD) approach relying on energy-balance concept has been adopted to determine the required design force demand on the strengthening elements. Nonlinear static and dynamic analyses are carried out on the numerical models of study frames to assess the effectiveness of selected strengthening techniques in improving the seismic performance of OGS frame.. Strengthening techniques based on steel braces and RC shear wall significantly reduced the peak interstory drift response of the OGS frame. However, the peak floor acceleration of these strengthened frames is amplified by more than 2.5 times as compared to that of unstrengthened frame. Steel caging technique of column strengthening resulted in a reasonable reduction in the peak interstory drift response without substantial amplification in peak floor acceleration of the OSG frame.

Seismic performance evaluation of steel moment resisting frames with mid-span rigid rocking cores

  • Ali Akbari;Ali Massumi;Mark Grigorian
    • Steel and Composite Structures
    • /
    • 제46권5호
    • /
    • pp.621-635
    • /
    • 2023
  • The combination of replaceable and repairable properties in structures has introduced new approach called "Low Damage Design Structures". These structural systems are designed in such a way that through self-centering, primary members and specific connections neither suffer damage nor experience permanent deformations after being exposed to severe earthquakes. The purpose of this study is the seismic assessment of steel moment resisting frames with the aid of rigid rocking cores. To this end, three steel moment resisting frames of 4-, 8-, and 12-story buildings with and without rocking cores were developed. The nonlinear static analysis and incremental dynamic analysis were performed by considering the effects of the vertical and horizontal components of 16 strong ground motions, including far-fault and near-fault arrays. The results reveal that rocking systems benefit from better seismic performance and energy dissipation compared to moment resisting frames and thus structures experience a lower level of damage under higher intensity measures. The analyses show that the interstory drift in structures equipped with stiff rocking cores is more uniform in static and dynamic analyses. A uniform interstory drift distribution leads to a uniform distribution of the bending moment and a reduction in the structure's total weight and future maintenance costs.

Steel hexagonal damper-brace system for efficient seismic protection of structures

  • Mohammad Mahdi, Javidan;Jinkoo, Kim
    • Steel and Composite Structures
    • /
    • 제45권5호
    • /
    • pp.683-695
    • /
    • 2022
  • Conventional braces are often used to provide stiffness to structures; however due to buckling they cannot be used as seismic energy dissipating elements. In this study, a seismic energy dissipation device is proposed which is comprised of a bracing member and a steel hysteretic damper made of steel hexagonal plates. The hexagonal shaped designated fuse causes formation of plastic hinges under axial deformation of the brace. The main advantages of this damper compared to conventional metallic dampers and buckling-restrained braces are the stable and controlled energy dissipation capability with ease of manufacture. The mechanical behavior of the damper is formulated first and a design procedure is provided. Next, the theoretical formulation and the efficiency of the damper are verified using finite element (FE) analyses. An analytical model of the damper is established and its efficiency is further investigated by applying it to seismic retrofit of a case study structure. The seismic performance of the structure is evaluated before and after retrofit in terms of maximum interstory drift ratio, top story displacement, residual displacement, and energy dissipation of dampers. Overall, the median of maximum interstory drift ratios is reduced from 3.8% to 1.6% and the residual displacement decreased in the x-direction which corresponds to the predominant mode shape of the structure. The analysis results show that the developed damper can provide cost-effective seismic protection of structures.

Correlation between seismic damage index and structural performance for Indian code-conforming RC frame buildings

  • Tushar K. Das;Pallab Das;Satyabrata Choudhury
    • Earthquakes and Structures
    • /
    • 제27권3호
    • /
    • pp.209-226
    • /
    • 2024
  • The susceptibility of Reinforced Concrete (RC) buildings to earthquake-induced damage is a critical concern, primarily attributed to their inadequate seismic performance. The existing earthquake-resistant design code of India prescribes guidelines to minimize seismic damage but does not provide any means for evaluating the actual seismic performance and damage. To ascertain the seismic performance of the structures quantitatively, it is crucial to classify damage into measurable damage states. Damage Index (DI) acts as an important tool for this purpose. Among various procedures for computation of DI, the modified Park and Ang Damage Index appears to be highly accurate. However, the major drawback of this method is that it is lengthy and time-consuming. On the other hand, structural performances can be evaluated using various performance parameters such as interstory drift ratio (IDR), inelastic deformation, etc., as described in FEMA-356 and ASCE-41 17. The present study explores the correlation between seismic DI and structural performance in RC frame buildings designed according to IS code. Sixteen building models, incorporating diverse configurations, are examined using nonlinear static and time history analyses. A simplified equation is developed by regression analysis to predict DI based on IDR, offering a computationally efficient alternative. Validation tests are done to confirm the equation's accuracy. Furthermore, a unified damage scale integrating DI and seismic performance is also proposed for seismic damage evaluation of buildings designed by IS code.

Post-Northridge WUF-B 접합부 골조의 내진 성능 평가 (Seismic Performance Evaluation of Post-Northridge WUF-B Connections Frame)

  • 한상환;문기훈;정지은;이기학
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.751-760
    • /
    • 2007
  • 본 연구에서는 Welded Unreinforced Flange-Bolted web(WUF-B) 접합부로 설계된 골조의 내진 성능 평가를 수행 하였다. WUF-B 접합부의 설계는 FEMA 350에서 제시한 방법을 사용하였으며, FEMA 350에 따르면 WUF-B 접합부 골조를 보통모멘트 골조(Ordinary Moment Resisting Steel Frames: OMFSFs)로 사용을 제한하고 있다. 이를 위해 WUF-B 접합부 실험결과를 바탕으로 패널존 강도 비를 변수로 하여 Post-Northridge WUF-B 접합부 해석 모델을 제안하였다. 이 해석 접합부 모델을 이용하여 SAC Phase II에서 사용된 3층, 9층 골조를 모델링 하고 내진 해석을 수행하였다. 해석 방법 중 비선형 정적 푸쉬오버 해석을 통하여 Post-Northridge 접합부 골조의 연성능력과 최대 모멘트 강도비, 최대 층간변위비를 구하였고, Incremental Dynamic Analysis(IDA)를 통해 각 성능 레벨(IO, CP)지점에서의 최대 층간변위비를 구하였다. 해석 결과는 Pre-Northridge 접합부 골조와 ductile 접합부 골조의 성능과 비교 검토 하였으며 접합부 상세 보강이 이루어진 Post-Northridge 접합부 골조의 성능이 Pre-Northridige 접합부 골조보다 향상된 것을 확인 할 수 있었다.

20층 비선형 벤치마크 빌딩에 대한 MR 유체 감쇠기의 최적위치 결정 (Optimal placement of MR dampers for 20-story nonlinear benchmark building)

  • 장종우;조상원;윤우현;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.153-160
    • /
    • 2003
  • The objective of optimal placement of dampers for a structure is to maximize the effective-ness of the vibration control with the same number of dampers. While many optimal placement methods of linear viscous dampers have been proposed and used, there are only a few methods for MR dampers. Here some optimal location indices for M dampers are proposed, which are similar to those for linear viscous dampers and show how large the structural responses on each floor are. Every time an additional MR damper is implemented, the optimal location index on each floor is measured, and then the next damper is installed on the floor with the maximum location index. In these sequential procedures, the peak interstory drift, the peak interstory velocity and the absolute acceleration of each floor are selected as the optimal location indeices. Four different earthquakes with various scales are loaded to the 20-story nonlinear benchmark building model (Otori et al. 2000, 2002). Passive On/on algorithms are used in order to represent the control algorithm of M dampers.

  • PDF

동조질량감쇠기와 동조액체기둥감쇠기의 건물응답의 제어성능 비교연구 (Comparative Study of Tuned Mass Damper and Tuned Liquid Column Damper for Response Control of Building structures)

  • 김홍진;김형섭;민경원;오정근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.427-434
    • /
    • 2003
  • In this study, the control performances of Tuned Mass Damper (TMD) and Tuned Liquid Column Damper (TLCD) are evaluated and compared for seismically excited structures. Results show that TLCD is more effective than TMD for interstory drift control while TLCD is as effective as TMD for acceleration control. In special, it is shown that interstory drifts are maximally controlled in lower floors and accelerations are reduced most in upper floors. This indicates that TLCD is an effective controller for earthquake-induced structures in terms of structural safety as well as serviceability.

  • PDF

20층 비선형 벤치마크 빌딩에 대한 자기유변유체 감쇠기의 최적위치 결정 (Optimal placement of MR dampers for 20-story nonlinear benchmark building)

  • 장종우;조상원;이인원;윤우현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.467-472
    • /
    • 2003
  • The objective of optimal placement of dampers for a structure is to maximize the effectiveness of the vibration control with the same number of dampers. While many optimal placement methods of linear viscous dampers have been proposed and used, there are only a few methods for MR dampers. Here some optimal location indices for MR dampers are proposed, which are similar to those for linear viscous dampers and show how large the structural responses on each floor we. Every time an additional MR damper is implemented, the optimal location index on each floor is measured, and then the next damper is installed on the floor with the maximum location index. In these sequential procedures, the peak interstory drift, the peak interstory velocity and the absolute acceleration of each floor are selected as the optimal location indeices. Four different earthquakes with various scales are loaded to the 20-story nonlinear benchmark building model (Otori et at. 2000, 2002). Passive On/Off algorithms are used in order to represent the control algorithm of MR dampers.

  • PDF