• Title/Summary/Keyword: Internet Measurement

Search Result 856, Processing Time 0.027 seconds

Teleoperate Temperature Calibration via Internet

  • Moonchaisook, Watakarn;Chaikla, Amphawan;Trisuwannawat, Thanit;Tammarungwattana, Narin;Julsereewong, Prasit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1438-1442
    • /
    • 2003
  • This paper presents the calibration service for the temperature sensor via the Internet. The purpose of the calibration service is to provide the teleoperate calibration procedure without skillful technician requirement at the client site. Besides the automatic measurement equipment that eases the operation, the developed software emphasizes the reliability of operation, simplifying the measurement data recording and processing, and achieving quality of the temperature measurements.

  • PDF

Implementation and Performance Analysis of DGPS & RTK Error Correction Data Real-Time Transmission System for Long-Distance in Mobile Environments

  • Cho, Ik-Sung;Ha, Chang-Seung;Yim, Jae-Hong
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.291-291
    • /
    • 2002
  • DGPS(Differential Global Positioning System) and RTK(RealTime Kinematic) is in one of today's most widely used surveying techniques. But It's use is restricted by the distance between reference station and rover station and it is difficult to process data in realtime by it's own orgnizational limitation in precise measurement of positioning. To meet these new demands, In This paper, new DGPS and RTK correction data services through Internet and PSTN(Public Switched Telephony Network) have been proposed. For this purpose, we implemented performance a DGPS and RTK error correction data transmission system for long-distance using the internet and PSTN network which allows a mobile user to increase the distance at which the rover receiver is located from the reference in realtime. and we analyzed and compared DGPS and RTK performance by experiments through the Internet and PSTN network with the distance and the time.

  • PDF

Service Quality Measurement and Comparison of Mobile Internet Telephony Services over WiBro and HSDPA (와이브로와 HSDPA를 통한 모바일 인터넷 전화 서비스 품질 측정 및 비교)

  • Kim, Beom-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.219-224
    • /
    • 2011
  • The quality management for mobile internet voice services currently being used widely cannot be achieved by the conventional quality management depending on a specific measurement equipment. For more systematic quality management, a real-time or preventive quality management scheme is proposed. The proposed scheme required a quality management software installed in a service user's terminal. In order to implement and realize the proposed scheme, it is a very important issue to ensure the reliability of the measurement results from the developed quality management software. Therefore, we have performed a large number of tests to verify the reliability of the software and discuss on the results in this paper.

Software-based Quality Measurement of Mobile VoIP Services (소프트웨어 기반 모바일 VoIP 서비스 품질 측정)

  • Kim, Beom-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • The mobile internet telephony service rapidly grows according to the extending deployment of smartphones. Unlike telephony service over a conventional public switched telephone network (PSTN) or mobile network, internet telephony service cannot guarantee its service quality, which can be severer in a wireless environment. Therefore, a more strict and systematic quality management is required for successful settlement and popularization of mobile internet telephony service. Existing quality management scheme using a specific measurement equipment cannot measure all the time so that it performs late management. In order to overcome the problem, this paper develops a software that can be equipped on a user terminal and measures the service quality all the time. By using the developed software, all-time and user-activating service quality monitoring can be supported.

Strengthening Packet Loss Measurement from the Network Intermediate Point

  • Lan, Haoliang;Ding, Wei;Zhang, YuMei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.12
    • /
    • pp.5948-5971
    • /
    • 2019
  • Estimating loss rates with the packet traces captured from some point in the middle of the network has received much attention within the research community. Meanwhile, existing intermediate-point methods like [1] require the capturing system to capture all the TCP traffic that crosses the border of an access network (typically Gigabit network) destined to or coming from the Internet. However, limited to the performance of current hardware and software, capturing network traffic in a Gigabit environment is still a challenging task. The uncaptured packets will affect the total number of captured packets and the estimated number of packet losses, which eventually affects the accuracy of the estimated loss rate. Therefore, to obtain more accurate loss rate, a method of strengthening packet loss measurement from the network intermediate point is proposed in this paper. Through constructing a series of heuristic rules and leveraging the binomial distribution principle, the proposed method realizes the compensation for the estimated loss rate. Also, experiment results show that although there is no increase in the proportion of accurate estimates, the compensation makes the majority of estimates closer to the accurate ones.

A case study on verification of internet survey (인터넷 설문조사의 검증에 관한 사례연구)

  • Ryu, Gui-Yeol;Moon, Young-Soo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • The object of study is to verify the accuracy of internet survey by comparing database data and internet survey. Internet survey was conducted on August, 2012. Respondents were subscribers of KISTI NDSL. Variables were age, organization as demographic variables, number of use, and period of use as attitude variables. Mismatch rates of age, organization, number of use, and period, are 7.5%, 5%, 92%, and 55% respectively. We could estimate the mismatch rate for age as 3% as a pessimistic point of view, and 1% as an optimistic point of view by detail verification. The mismatch rates of organization are 4.5% as a pessimistic point of view, and 2% as an optimistic point of view. The mismatch rates for the frequency of use, the period of use are very high, because measurement error, problems in memory, and internet attitude, etc. Implication of this study is that data of internet survey could be reliable. Many further researches are needed for verification of internet survey.

Improved Measurement Indices for IPv6 Usage in South Korea (국내 IPv6 사용도 실측 지표 개선안)

  • Kim, Ha-Young;Park, Sung-Kyu;Ryu, Ji-Young;Kim, Tae-Sung;Yang, Won-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1221-1232
    • /
    • 2016
  • Even though there have been a surge in demand for Internet addresses, but the existing IPv4 addresses are virtually depleted. Therefore, the conversion of IPv6 is being made consistently and the need for systematic situation grasp for IPv6 adoption through the measurement index of the IPv6 is on the rise. This study investigated domestic and overseas IPv6 usage measurement techniques and cases. Through evaluating existing measurement indices, this study derives the improved indices of measuring IPv6 usage and proposes the implementation methods of them.

Design and Implementation of Magnetic Induction based Wireless Underground Communication System Supporting Distance Measurement

  • Kim, Min-Joon;Chae, Sung-Hun;Shim, Young-Bo;Lee, Dong-Hyun;Kim, Myung-Jin;Moon, Yeon-Kug;Kwon, Kon-Woo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4227-4240
    • /
    • 2019
  • In this paper, we present our proposed magnetic induction based wireless communication system. The proposed system is designed to perform communication as well as distance measurement in underground environments. In order to improve the communication quality, we propose and implement the adaptive channel compensation technique. Based on the fact that the channel may be fast time-varying, we keep track of the channel status each time the data is received and accordingly compensate the channel coefficient for any change in the channel status. By using the proposed compensation technique, the developed platform can reliably communicate over distances of 10m while the packet error rate is being maintained under 5%. We also implement the distance measurement block that is useful for various applications that should promptly estimate the location of nearby nodes in communication. The distance between two nodes in communication is estimated by generating a table describing pairs of the magnetic signal strength and the corresponding distance. The experiment result shows that the platform can estimate the distance of a node located within 10m range with the measurement error less than 50cm.

Object Dimension Estimation for Remote Visual Inspection in Borescope Systems

  • Kim, Hyun-Sik;Park, Yong-Suk
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4160-4173
    • /
    • 2019
  • Borescopes facilitate the inspection of areas inside machines and systems that are not directly accessible for visual inspection. They offer real-time, up-close access to confined and hard-to-access spaces without having to dismantle or destructure the object under inspection. Borescopes are ideal instruments for routine maintenance, quality inspection and monitoring of systems and structures. The main application being fault or defect detection, it is useful to have measuring capability to quantify object dimensions in a target area. High-end borescopes use multi-optic solutions to provide measurement information of viewed objects. Multi-optic solutions can provide accurate measurements at the expense of structural complexity and cost increase. Measuring functionality is often unavailable in low-end, single camera borescopes. In this paper, a single camera measurement solution that enables the size estimation of viewed objects is proposed. The proposed solution computes and overlays a scaled grid of known spacing value over the screen view, enabling the human inspector to estimate the size of the objects in view. The proposed method provides a simple means of measurement that is applicable to low-end borescopes with no built-in measurement capability.

Development of Plantar Pressure Measurement System and Personal Classification Study based on Plantar Pressure Image

  • Ho, Jong Gab;Kim, Dae Gyeom;Kim, Young;Jang, Seung-wan;Min, Se Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.11
    • /
    • pp.3875-3891
    • /
    • 2021
  • In this study, a Velostat pressure sensor was manufactured to develop a plantar pressure measurement system and a C#-based application was developed to monitor and collect plantar pressure data in real time. In order to evaluate the characteristics of the proposed plantar pressure measurement system, the accuracy of plantar pressure index and personal classification was verified by comparing with MatScan, a commercial plantar pressure measurement system. As a result, the output characteristics according to the weight of the Velostat pressure sensor were evaluated and a trend line with the reliability of r2 = 0.98 was detected. The Root Mean Square Error(RMSE) of the weighted area was 11.315 cm2, the RMSE of the x coordinate of Center of Pressure(CoPx) was 1.036 cm and the RMSE of the y coordinate of Center of Pressure(CoPy) was 0.936 cm. Finally, inaccuracy of personal classification, the proposed system was 99.47% and MatScan was 96.86%. Based on the advantage of being simple to implement and capable of manufacturing at low cost, it is considered that it can be applied to various fields of measuring vital signs such as sitting posture and breathing in addition to the plantar pressure measurement system.