• Title/Summary/Keyword: Internal valve

Search Result 342, Processing Time 0.028 seconds

A Study on the Wear Characteristics of Aluminizing Steel ( 1 ) - Wear in Run-in Period on Rolling-Sliding Contact - (알루미나이징 강의 마모특성에 관한 연구 ( 1 ) - Rolling-Sliding 마찰의 초기마모영역을 중심으로 -)

  • 이규용
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.69-78
    • /
    • 1978
  • It is well known that the aluminizing steel is excellent in corrosion resistance and heat resistance. Therefore it has been used as boiler parts, heat exchanger parts and guide rails which are used under comparatively simple conditions. Recently, it has been noticed that aluminizing steel has high resistance to various atmosphere, high temperature oxidation and seawater resistance. So its usage has been extended widely to the production of parts such as intake and exhaust valve of internal combustion engine, turbine blade and pipelines On ships which required such properties. It is considered that aluminium coated steel is excellent in wear resistance because of high hardness on main ingredient FezAIs of Fe-AI alloy layer existed in diffusion coating layer. And it will beused as a new material taking wear resitance with seawater resistance in marine field. However it is difficult to findout any report concering the wear behaviors or properties of alum in izing steel. In this study the experiment was carried out under the condition of rolling-sliding contact using an Amsler-type wear testing machine at 0.80, 0.91, 1. 10, 1. 25% of slip ratio and 55.43, 78.38, 110.85 kg/mm^2 of Hertz's contact stress in run-in period for the purpose of service-ability test of aluminizing steel as a wear resisting material and obtaining the available design data. The followings are the obtained results from the experimen tal study; 1) The 2nd diffusion material has most excellent wear resistance. This material has brought out about 18% decrease of wear weight in a lower friction load level and 40~G decrease in a higher level comparing to the raw material. 2) Satisfactory effect of wear resistivity cannot be much expected in 2nd diffusion specimens. This is considered due to the formation of fine void in the alloy layer near the boundary to the aluminium layer. 3) Fracture on friction surface of aluminizing steel by the rolling-sliding contact is spalling, and spalling crack occurres initially beneath the specimen surface near the boundary in diffusion coating layer.

  • PDF

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.

Triangular Resection of the Upper Lateral Cartilage for Middle Vault Deviation

  • Ryu, Gwanghui;Seo, Min Young;Lee, Kyung Eun;Hong, Sang Duk;Chung, Seung-Kyu;Dhong, Hun-Jong;Kim, Hyo Yeol
    • Clinical and Experimental Otorhinolaryngology
    • /
    • v.11 no.4
    • /
    • pp.275-280
    • /
    • 2018
  • Objectives. Middle vault deviation has a significant effect on the aesthetic and functional aspects of the nose, and its management continues to be a challenge. Spreader graft and its modification techniques have been focused, but there has been scarce consideration for removing surplus portion and balancing the upper lateral cartilage (ULC). This study aimed to report the newly invented triangular-shaped resection technique ("triangular resection") of the ULC and to evaluate its efficacy for correcting middle vault deviation. Methods. A retrospective study included 17 consecutive patients who presented with middle vault deviation and underwent septorhinoplasty by using triangular resection at a tertiary academic hospital from February 2014 and March 2016. Their outcomes were evaluated pre- and postoperatively including medical photographs, acoustic rhinometry and subjective nasal obstruction using a 7-point Likert scale. Results. The immediate outcomes were evaluated around 1 month after surgery, and long-term outcomes were available in 12 patients; the mean follow-up period was 9.1 months. Nasal tip deviation angle was reduced from $5.66^{\circ}$ to $2.37^{\circ}$ immediately (P<0.001). Middle vault deviation also improved from $169.50^{\circ}$ to $177.24^{\circ}$ (P<0.001). Long-term results were $2.49^{\circ}$ (P=0.015) for nasal tip deviation and $178.68^{\circ}$ (P=0.002) for middle vault deviation. The aesthetic outcome involved a complete correction in eight patients (47.1%), a minimally visible deviation in seven patients (41.2%) and a remaining residual deviation in two patients (11.8%). Pre- and postoperative minimal cross-sectional areas (summation of the right and left sides) were 0.86 and 1.07, respectively (P=0.021). Fifteen patients answered about their nasal obstruction symptoms and the median symptom score had alleviated from 6.0 to 3.0 (P=0.004). Conclusion. Triangular resection of the ULC is a simple and effective method for correcting middle vault deviation and balancing the ULCs without complications as internal nasal valve narrowing.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Clinical Analysis to the Early Results of the CABG (관상동맥우회술의 조기 성적에 대한 임상적 고찰)

  • Kim, Dae-Sig;Yang, Jin-Young;Koo, Won-Mo;Moon, Seung-Chul;Lee, Gun;Lee, Hyeon-Jae;Lim, Chang-Young
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1043-1048
    • /
    • 1998
  • Background: As coronary arterial disease is increasing, we evaluated the patients who underwent CABG(Coronary Artery Bypass Grafting) and thus report the early results and risk factors related to mortality and morbidity. Materials and methods: Between July 1996 and February 1998, 42 patients underwent CABG. We analyzed age, sex, preoperative ejection fraction, Canadian heart classification, prevalence factors of CAD(Coronary Artery Disease), angiographic findings, graft vessel numbers, IMA(Internal Mallary Artery) use, ECC* (extracorporeal circulation) time and morbidity. We also evaluated the mortality rate and the causes of death. Results: Complication was developed at 17cases. The average age of the complication group was 61±11.9 years and that of the noncomplication group was 51±10.5 years(p=0.004). ECC time was 198±42.5(min) in the complication group and 158±47.4(min) in the noncomplication group(p=0.008). The other factors had no correlation to the morbidity, statistically. The average follow up duration was 12.5 months and all the patients were alive except for the 2 expired cases. The mortality rate was 4.7%, among which one patient who underwent CABG with aortic valve replacement died due to multiorgan failure and the other died due to sepsis with pneumonia and wound infection. Conclusions: We conclude that the risk factors related to morbidity were age and ECC time, and that there were no correlations between other factors and morbidity.

  • PDF

Clinical Analysis of 500 Cases of Coronary Artery Bypass Grafting (관상동맥 우회술 500례의 임상적 고찰)

  • Shin, Yoon-Cheol;Kim, Ki-Bong;Ahn, Hyuk;Chae, Hurn;Rho, Joon-Ryang;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.525-531
    • /
    • 1999
  • Background: We analyzed five hundred patients who underwent either isolated or concomitant coronary artery bypass grafting(CABG) between November 1981 and June 1997. Material and Method: There were 330 males and 170 females with a mean age of 57.4$\pm$8.9 years. To evaluate the preoperative status, we performed electrocardiograghy, echocardiography, MIBI scan, Duplex sonogram, common blood test including CK and LDH and coronary angiography. Result: Preoperative clinical diagnoses were unstable angina in 282 (56.4%), stable angina in 141 (28.2%), postinfarction angina in 58 (11.6%), acute myocardial infarction in 8 (1.6%), variant angina in 7 (1.4%) and failed percutaneous transluminal coronary angioplasty in 4 (0.8%) patients. Preoperative angiographic diagnoses were three-vessel disease in 263 (52.6%), two-vessel disease in 93 (18.6%), one-vessel disease in 71 (14.2%), left main disease in 68 (13.6%), and others in 5 (1.0%) patients. Patients had various risk factors for coronary disease, and the frequency of the risk factors such as hypertension, diabetes and smoking showed increasing tendency year by year. We used saphenous vein grafts in 1143, internal thoracic artery grafts in 442, radial artery graft in 17, and gastroepiploic artery graft in 1 anastomosis. The mean number of grafts was 3.2$\pm$1.2 per patient. Concomitant operations were prosthetic valve replacement or valvuloplasty in 31, coronary endarterectomy and angioplasty in 27, left main coronary angioplasty in 13, carotid endarterectomy in 5, and neurologic problems, bleeding, and perioperative myocardial infarction. The mean follow-up period was 25$\pm$23 months and there were 5 cases of reoperation. Conclusion: We hope that the surgical results would improve with the accumulation of experience, application of new myocardial protection technique, and timely intervention of mechanical assisted devices.

  • PDF

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Clinical Features of Symptomatic Meckel's Diverticulum (증후성 멕켈 게실의 임상적 고찰)

  • Lee, Young Ah;Seo, Ji Hyun;Youn, Hee Sang;Lee, Gyeong Hun;Kim, Jae Young;Choi, Gwang Hae;Choi, Byung Ho;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.2
    • /
    • pp.193-199
    • /
    • 2006
  • Purpose: The proper diagnosis of Meckel's diverticulum (MD) is difficult and delayed because of the variety of clinical manifestations. We reviewed clinical characteristics of symptomatic MD to facilitate early detection. Methods: We analyzed retrospectively the clinical manifestations, diagnostic tools, histopathological findings, and operative findings in 58 patients with symptomatic MD. Results: The male to female ratio was 2.8 : 1. The most common symptom of MD was bleeding. Others symptoms included: vomiting, abdominal pain, irritability, abdominal distension and fever in the order of frequency. The clinical manifestations of symptomatic MD were lower gastrointestinal bleeding, intestinal obstruction, perforation, diverticulitis and hemoperitoneum, in the order of frequency. The causes of intestinal obstruction were intussusception, internal hernia, band, volvulus, invagination, in the order of frequency. Seventy five percent of patient with MD were diagnosed prior to 5 years of age. The most frequently used diagnostic tool was the Meckel's scan. The diverticulum was located 2 cm to 120 cm proximal to the ileocecal valve. The length of the diverticulum ranged from 1 cm to 10 cm and 94% were less than 5 cm. The most common ectopic tissue found in the MD was gastric mucosa. Ileal resection was more frequently performed than diverticulectomy. Conclusion: In cases of unexplained gastrointestinal bleeding, obstruction and repeated intussusception, the meckel's scan, ultrasound and computed tomography shoud be considered to rule out MD, and if clinically necessary, an exploratory laparotomy when needed.

  • PDF

Coronary Artery Bypass Graft in Patient with Advanced Left Ventricular Dysfunction (중등도 이상의 좌심실 기능 부전 환자에서의 관상동 우회술의 임상 분석)

  • 정종필;김승우;신제균
    • Journal of Chest Surgery
    • /
    • v.34 no.12
    • /
    • pp.901-908
    • /
    • 2001
  • Background : Coronary artery bypass graft(CABG) in patients with advanced left ventricular dysfunction has often been regarded as having high mortality rate, despite the great improvement in operative result of CABG. With recent advances in surgical technique and myocardial protection, surgical revascularization improved the symptom and long-term survival of these high risk patients more than the medical conservative treatment. Material and Methold : Clinical data of 31(4.1%) patients with preoperative ejection fraction less than 30% among 864 CABGs performed between January 1995 and March 1999 were retrospectively analyzed and pre- and postoperative changes of the ejection fraction on echocardiography were analyzed. There were 26 men and 5 women. The mean age was 60.7 years(range 41 to 72 years). History of myocardial infarction(30 cases, 98%) was the most common preoperative risk factor. There were seven irreversible myocardial infarction on thallium scan. Most patients had triple vessel diseases(26 cases, 84%) and first degree of Rentrop classification(16 cases, 52%) on coronary angiography. The mean number of distal anastomosis during CABG was per patient was 4.9${\pm}$0.8 sites in each patient. In addition to long saphenous veins, the internal mammary artery was used in 20 patients. Total bypass time was 244.7${\pm}$3.7 minutes(range, 117 to 567 minutes), and mean aortic cross-clamp time was 77.9 ${\pm}$ 1.6 minutes(range, 30 to 178 minutes). There were five other reparative procedures such as two left ventricular aneurysrmectomy, two mitral repair, and one aortic valve replacement. There were twelve postoperative complications such as three cardiac arrhythmia, two bleeding(re-operation), one delayed sternal closure, eleven usage of intra-aortic balloon counterpulsation for low cardiac output. Two patients died, postoperative mortality was 6.5% . Twenty-nine patients were relieved of chest pain and left ventricular ejection fraction after operation was significantly higher(38.5${\pm}$11.6%, p 0.001) as compared with preoperative left ventricular ejection fraction(25.3${\pm}$2.3%). The follow up period of out patient was 25. 3 months. Conclusion: In patients with coronary artery disease and advanced left ventricular dysfunction, coronary artery bypass grafting can be performed relatively safely with improvement in left ventricular function, but it will be necessary to study long term results.

  • PDF