• Title/Summary/Keyword: Internal radiation dosimetry

Search Result 51, Processing Time 0.026 seconds

Discrepancies between Calculated and Delivered Dose Distributions of Respiratory Gated IMRT Fields according to the Target Motion Ranges for Lung and Liver Cancer Patients (호흡연동방사선치료시 폐암과 간암환자의 병소 움직임 크기에 따른 선량분포 차이 분석)

  • Kim, Youngkuk;Lim, Sangwook;Choi, Ji Hoon;Ma, Sun Young;Jeung, Tae Sig;Ro, Tae Ik
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.242-247
    • /
    • 2014
  • To see the discrepancies between the calculated and the delivered dose distribution of IMRT fields for respiratory-induced moving target according to the motion ranges. Four IMRT plans in which there are five fields, for lung and liver patients were selected. The gantry angles were set to $0^{\circ}$ for every field and recalculated using TPS (Eclipse Ver 8.1, Varian Medical Systems, Inc., USA). The ion-chamber array detector (MatriXX, IBA Dosimetry, Germany) was placed on the respiratory simulating platform and made it to move with ranges of 1, 2, and 3 cm, respectively. The IMRT fields were delivered to the detector with 30~70% gating windows. The comparison was performed by gamma index with tolerance of 3 mm and 3%. The average pass rate was 98.63% when there's no motion. When 1.0, 2.0, 3.0 cm motion ranges were simulated, the average pass rate were 98.59%, 97.82%, and 95.84%, respectively. Therefore, ITV margin should be increased or gating windows should be decreased for targets with large motion ranges.

Physical Dosimetry in Radioactive Iodine Treatment in the Patients with Thyroid Cancer (갑상선암 환자에 대한 방사성옥소 치료시 물리적 선량 측정)

  • Kim, Myung-Seon;Jeong, Nae-In;Lee, Jai-Yong;Kim, Chong-Soon;Kim, Chong-Ho;Lee, Myung-Chul;Koh, Channg-Soon;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.124-132
    • /
    • 1994
  • Radioactive iodine has been widely used in patients with thyroid cancer combined with surgical treatment. However, due to individual variations in absorption and excretion and uptake by tumor tissue of radioactive iodine, there are differences in therapeutic effect and adverse effects even if the same doses are administrated. So this study compared the therapeutic effect and radiation hazard by measuring internal radiation dose. Of total 27 patients with well differentiated thyroid cancer who had been thyroidectomized, we administered radioactive iodine 100 mCi, 150 mCi, 200 mCi. According to BEL DOSIMETRY PROTO-COL, beta and gamma ray dose were estimated from a pelt of the logarithm of the percent of dose per liter of whole blood versus day, and percent dose retained versus day using somilogarithmic paper, respectively. 1) Physical dose to whole blood averaged $56.54{\pm}13.02$ rad in 100 mCi administered group, $76.83{\pm}19.97$ rad in 150 mCi administered group, $95.08{\pm}25.51$ rad in 200 mCi administered group and there has been a significant correlation among the groups. 2) Mean percent dose retained 48 hours later was 26.34%. 3) There was no significant correlation of physical dose between absence and presence of metastasis. 4) 17 of 19 patients who has been followed up with TSH and serum throglobulin, Thallium scan were successfully ablated by radioactive iodine. 5) Leukocyte, lymphocyte, neutrophil, platelet counts all deelined in 4.6 weeks and most of all were restored 3 months later. 6) There was no significant correlation between physical dosimetry and biologic dosimetry. Generally administered doses of radioactive iodine (100-200 mCi) to patients with thyroid cancer postoperatively had developed transient bone marrow suppression and minimal chromosomal aberration, but they were within safety dose to blood (200 rad). And there has been no significant differences in residual dose 48 hours later between Korean and western people.

  • PDF

Age-Specific Thyroid Internal Dose Estimation for Koreans

  • Kwon, Tae-Eun;Yoon, Seokwon;Ha, Wi-Ho;Chung, Yoonsun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.170-177
    • /
    • 2021
  • Background: The International Commission on Radiological Protection is preparing to provide reference dose coefficients for environmental radioiodine intake based on newly developed age-specific biokinetic models. However, the biokinetics of iodine has been reported to be strongly dependent on the dietary intake of stable iodine; for example, the thyroidal uptake of iodine may be substantially lower in iodine-rich regions than in iodine-deficient regions. Therefore, this study attempted to establish a system of age-specific thyroid dose estimation for South Koreans, whose daily iodine intakes are significantly higher than that of the world population. Materials and Methods: Korean age-specific biokinetic parameters and thyroid masses were derived based on the previously developed Korean adult model and the Korean anatomical reference data for adults, respectively. This study complied with the principles used in the development of age-specific biokinetic models for world population and used the ratios of baseline values for each age group relative to the value for adults to derive age-specific values. Results and Discussion: Biokinetic model predictions based on the Korean age-specific parameters showed significant differences in iodine behaviors in the body compared to those predicted using the model for the world population. In particular, the Korean age-specific thyroid dose coefficients for 129I and 131I were considerably lower than those calculated for the world population (25%-76% of the values for the world population). Conclusion: These differences stress the need for Korean-specific internal dose assessments for infants and children, which can be achieved by using the data calculated in this study.

A Study on Electron Beam Dosimetry for Chest Wall Irradiation (흉곽(胸廓)의 전자선(電子線) 조사시(照射時) 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.41-45
    • /
    • 1983
  • To obtain 7 MeV electron beam which is suitable for treatment of the chest wall after radical of modified radical mastectomy, the authors reduced the energy of electron beam by means by Lucite plate inserted in the beam. To determine the proper thickness of the Lucite plate necessary to reduce the energy of 9 MeV electron beam to 6 MeV, dosimetry was made by using a parallel plate ionization chamber in polystyrene phantom. Separation between two adjacent fields, 7 MeV for chest wall and 12 MeV for internal mammary region, was studied by means of film dosimetry in both polytyrene phantom and Humanoid phantom. The results were as follows. 1. The average energy of 9 MeV electron beam transmitted through the Lucite plate was reduced. Reduction was proportional to the thickness of the Lucite plate in the rate of 1.7 MeV/cm. 2. The proper thickness of the Lucite plate necessary to obtain 6 MeV electron beam from 9 MeV was 1.2 cm. 3. 7 MeV electron beam, 80% dose at 2cm depth, is adequate for treatment of the chest wall. 4. Proper separation between two adjacent electron fields, 7 MeV and 12 MeV, was 5mm on both flat surface and sloping surface to produce uniform dose distribution.

  • PDF

Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy

  • Soo Min Lee;Chansoo Choi;Ji Won Choi;Chul Hee Min;Seulki Ko;Bangho Shin;Chan Hyeong Kim;Yeon Soo Yeom
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2247-2257
    • /
    • 2024
  • To investigate the impact of the recently released pediatric reference voxel phantoms (0-, 1-, 5-, 10-, 15-year-old males and females) of the International Commission on Radiological Protection (ICRP) on organ dose estimates for radioactive iodine (RAI) treatment in pediatric patients, we calculated and analyzed pediatric-specific iodine131 S values (rT ← thyroid) for the 30 radiosensitive organs by conducting Monte Carlo simulations using the Geant4. The gender dependency in the S values was frequently seen for the 15-year-old phantoms with higher S values of female than male. In addition, the age dependency in the S values was observed for most target organs; that is, the S values tend to decrease for older ages (e.g., ~120 times for the gonads between the adult and newborn) due mainly to the inter-organ distances generally longer for older ages. Moreover, we observed that the iodine-131 S values tend to be significantly greater by up to ~145.5 times than those of the stylized phantoms that have been widely used for organ dose estimates of pediatric RAI patients. We believe that the pediatric-specific iodine-131 S values (rT ← thyroid) of the ICRP pediatric reference voxel phantoms should be beneficial to improve the dosimetry of pediatric RAI patients.

Chromosomal Aberrations Induced by in Vitro Irradiation of $^{131}I$ ($^{131}I$의 체외 방사선조사에 의한 염색체이상)

  • Kim, Eun-Sil;Kim, Myung-Seon;Seo, Doo-Seon;Jeong, Nae-In;Rho, Seung-Ik;Lee, Jae-Yong;Kim, Chong-Soon;Han, Seung-Soo;Kim, Hee-Geun;Kang, Duck-Won;Song, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.133-140
    • /
    • 1994
  • Recently, there are many considerations and studies on biological effects of radiations in radiation workers, as well as in accidentally or therapeutically irradiated persons. The most practical and reliable method of dosimetry for radiation accidents is the scoring of gross chromosomal aberrations in human lymphocytes (Ydr) as a biological dosimetry. By the way, although usual doses of $^{131}I$ administered therapeutically for thyroid cancer are ranging from 100 mCi to 200 mCi, there are differences of absorbed doses and Ydr, ranging from 0.004 to 0.04, on equally administered $^{131}I$ due to variations in metabolic characteristics, stage of tumors and physical status of subjects. In this study, We exert to obtain the dose-response relationships of $^{131}I$, as a good guide to evaluating acute effects of accidental irradiations and radiation induced leukemia or solid tumor, by in vitro induction of chromosomal aberrations. we studied the relationship between radiation dose (D) and the frequency of chromosomal aberrations (Ydr) obserbed in peripheral lymphocytes that were irradiated in vitro with $^{131}I$ at doses ranging from 0.05 to 6.00 Gy. By scoring cells with unstable chromosomal aberrations (dicentric chromosomes and ring chromosomes) we obtained this linear-quadratic dose response equation Ydr=0.064351 $D^2$-0.13143 D+0.045684 This dose-response relationship may be useful for evaluating acute and chronic $^{131}I$ induced biological effects.

  • PDF

Evaluation of Internal Dosimetry according to Various Radionuclides Conditions in Nuclear Medicine Myocardial Scan: Monte Carlo Simulation (심근 핵의학 검사에서 다양한 방사성핵종 조건에 따른 내부피폭선량 평가: 몬테카를로 시뮬레이션)

  • Min-Gwan Lee;Chanrok Park
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.213-218
    • /
    • 2024
  • The myocardial nuclear medicine examination is widely performed to diagnose myocardium disease using various radionuclides. Although image quality according to radionuclides has improved, the radiation exposure for target organ as well as peripheral organs should be considered. Here, the aim of this study was to evaluate absorbed dose (Gy) for peripheral organs in myocardial nuclear medicine scan from myocardium according to various scan environments based on Monte Carlo simulation. The simulation environment was modeled 5 cases, which were considered by radionuclides, number of injections, and radiodosage. In addition, the each radionuclide simulation such as distribution fraction was considered by recommended standard protocol, and the mesh computational female phantom, which is provided by International Commission on Radiological Protection (ICRP) 145, was used using the particle and heavy ion transport code system (PHITS) version 3.33. Based on the results, the closer to the myocardium, the higher the absorbed dose values. In addition, application for dual injection for radionuclides leaded to high absorbed dose compared with single injection for radionuclide. Consequently, there is difference for absorbed dose according to radionuclides, number of injections, and radiodosage. To detect the accurate diseased area, acquisition for improved image quality is crucial process by injecting radionuclides, however, we need to consider absorbed dose both target and peripheral inner organs from radionuclides in terms radiation protection for patient.

Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy (자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가)

  • Lee, Yun-Jong;Nho, Young-Chang;Lee, Jai-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.4
    • /
    • pp.387-391
    • /
    • 2006
  • Computational and experimental dosimetry of Henschke applicator with respect to high dose rate brachytherapy using the MIRD phantom and a remote control afterloader were performed. A comparison of computational dosimetry was made between the simulated Monte Carlo dosimetry and GAMMADOT brachytherapy Planning system's dosimetry. Dose measurements was performed using ion chamber in a water phantom. Dose rates are calculated using Monte Carlo code MCNP4B and the GAMMADOT. Thecomputational models include the detailed geometry of Ir-192 source, tandem tube, and shielded ovoids for accurate estimation. And transit dose delivered during source extension to and retraction from a given dwell position was estimated by Monte Carlo simulations. Point doses at ICRU bladder/rectal pointswhich have been recommened by ICRU 38 was assessed. Calculated and measured dose distribution data agreed within 4% each other. The shielding effect of ovoids leads to 19% and 20% dose reduction at bladder surface and rectal points.

THE IMPORTANCE OF PATIENT-SPECIFIC DOSE CALCULATIONS IN NUCLEAR MEDICINE

  • Stabin, Michael G.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.527-532
    • /
    • 2008
  • As therapeutic uses of radionuclides in nuclear medicine increases, the use of patient-specific methods for calculation of radiation dose becomes more important. In this manuscript basic methods and resources for internal dose calculations are outlined, with a focus on how current changes and advances are making more accurate and detailed, patient-individualized dose calculations possible. Most current resources make use of standardized models of the human body representing median individuals, but the use of image-based and more realistic models will soon take their place, and will permit adjustments to represent individual patients and tailor therapy planning uniquely for each subject.

Intercomparison Exercise on Internal Dose Assessment in Korea (국내 내부피폭방사선량 평가 상호비교)

  • Lee, Jong-Il;Kim, Jang-Lyul;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.64-70
    • /
    • 2011
  • The intercomparison exercise on internal dose assessment has been carried out for the purpose of the evaluation for harmonization of internal dosimetry between the nuclear-related institutes in Korea. The exercises of 9 items on internal dose assessment have been developed for the unknown internal dosimetric parameters such as the intake pathway, absorption type, AMAD, and intake time of a radionuclide. Solutions to these exercises were reported by 7 participants from 5 institutes. The range of the ratio between the individual values and the geometric mean value of the evaluated doses for the exercises was $5.75{\times}10^{-4}$ ~ 9.81. But without the extreme partial solution, the range of the ratio was 0.216 ~ 3.12.