• Title/Summary/Keyword: Internal generation of wave

Search Result 47, Processing Time 0.025 seconds

Periodically Poled $KNbO_3$ Crystals for Quasi-Phase-Matching

  • Kim, Joong-Hyun;Lee, Sooseok;Yoon, Choon-Sup
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.18-18
    • /
    • 2002
  • Although it was suggested in 1962 that an efficient wavelength conversion could be achieved using ferroelectric crystals of periodic 180° domains, it was not until 1990's that quasi-phase-matching (QPM) became realized, as technology for periodic poling of LiNbO₃ crystals was readily available. Since ferroelectric domain inversion brings about change of the sign of second-order nonlinear susceptibility, periodically poled ferroelectric structures provide an ideal way of achieving QPM for second-harmonic generation and optical parametric oscillation. Periodically poled ferroelectric domains can also be utilized for optical devices, such as Brags electrooptic modulators. fabrication of stable periodic domain structures depends on a number of poling parameters of a ferroelectric crystal, such as coercive field, internal field and electrical conductivity. We present poling kinetics of KNbO₃ crystals, which involve domain nucleation and growth, backswitching, relaxation of internal field. Optimum poling conditions were established by designing a proper wave shape of external field. We demonstrate an efficient second-harmonic generation using QPM in a periodically poled KNbO₃ crystal.

  • PDF

SOLUTION OF THE SUPER BESSEL WAVE EQUATION WITH INTEGRAL PARAMETER m

  • Lee, Nae-Ja;Liu, Chang-Keng
    • Bulletin of the Korean Mathematical Society
    • /
    • v.20 no.2
    • /
    • pp.99-103
    • /
    • 1983
  • Internal heat generation is one of the insidious conditions affecting the quality of an industrial product after it is cast, coated, molded, forged or laminated. Frequently, the product is pressed into service before the exothermic chemical reactions in the generic material has been completed. The heat liberated from this continuing chemical reaction or the residual deformation from the rheological activities in the materials must be adequately removed or prevented, or the product may be discolored, warped, weakened or even "ignited" spontaneously. Numerous instances of premature structural failures, product-recalls, and/or system-malfunctions have been recorded in recent history. The Coulee Dam was poured with pre-chilled concrete just to negate this freakish encore. It is well-known that concrete (a non-isotropic conducting medium), for instance, takes 28 days to develop its full strength. During this period of curing it is conceivable that the processes of internal heat generation, heat conduction and heat dissipation take place simultaneously inside the medium.he medium.

  • PDF

Experimental study on motions of VLCO for wave power generation (2. Multiple floating bodies) (파력발전용 가변수주진동장치의 운동에 대한 실험적 연구 (2. 다수 부유체))

  • Lee, Seung-Chul;Goo, Ja-Sam
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.27-31
    • /
    • 2013
  • The structure of a variable liquid column oscillator(VLCO) is analogous to that of the tuned liquid column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. The VLCO is a system for absorbing the high kinetic energy of the accelerated motions of multiple floating bodies using an air-spring effect produced the installation of inner air chambers. Thus, a VLCO can improve the energy efficiency of the activating object type of wave energy converters made by the Pelamis Company. In this research, an experiment was performed in two cases: with the top valves closed and open. The floating bodies were connected by hinges. The effect of the internal flow was estimated by comparing the results for the closed and open valves.

An Experimental Analysis of Ultrasonic Cavitation Effect on Ondol Pipeline Management (온돌 파이프라인 관리를 위한 초음파 캐비테이션 효과에 대한 실험적 분석)

  • Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.67-75
    • /
    • 2024
  • In the context of Korean residential heating systems, Ondol pipelines are a prevalent choice. However, the maintenance of these pipelines becomes a complex task once they are embedded within concrete structures. As time progresses, the accumulation of sludge, corrosive oxides, and microorganisms on the inner surfaces of these pipelines diminishes their heating efficiency. In extreme scenarios, this accumulation can induce corrosion and scale formation, compromising the system's integrity. Consequently, this research introduces an ultrasonic generation system tailored for the upkeep of Ondol pipelines, with the objective of empirically assessing its practicality. This investigation delineates three variants of ultrasonic generating apparatuses: those employing surface vibration, external generation, and internal generation techniques. To emulate the presence of contaminants within the pipelines, substances in powder, slurry, and liquid forms were employed. The efficacy of the cleaning process post-ultrasonic wave application was scrutinized over time, with image analysis methodologies being utilized to evaluate the outcomes. The findings indicate that ultrasonic waves, whether generated externally or internally, exert a beneficial effect on the cleanliness of the pipelines. Given the inherent characteristics of Ondol pipelines, external generation proves impractical, thereby rendering internal generation a more viable solution for pipeline maintenance. It is anticipated that future endeavors will pave the way for innovative maintenance strategies for Ondol pipelines, particularly through the advancement of internal generation technologies for pipeline applications.

Protective Relaying Algorithm for 3-Phase Power Transformer Protection based on Fuzzy Decision Making

  • Kim, Sang-Tae;Lee, Seung-Jae;Kang, Sang-Hee;Park, Myeon-Song;Yoon, Sang-Hyun;Lee, Tae-Sung
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.26-30
    • /
    • 2002
  • The four fuzzy criteria to distinguish the internal fault from the inrush fur the power transformer protection have been identified. They are based on the wave shape, terminal voltage, fundamental and second harmonic component of differential current. systematic way to determine the associated fuzzy membership function is also proposed.

Development of 3-D Nonlinear Wave Driver Using SPH (SPH을 활용한 3차원 비선형 파랑모형 개발)

  • Cho, Yong Jun;Kim, Gweon Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.559-573
    • /
    • 2008
  • In this study, we newly proposed 3-D nonlinear wave driver utilizing the Navier-Stokes Eq. the numerical integration of which is carried out using SPH (Smoothed Particle Hydrodynamics), an internal wave generation with the source function of Gaussian distribution and an energy absorbing layer. For the verification of new 3-D nonlinear wave driver, we numerically simulate the sloshing problem within a parabolic water basin triggered by a Gaussian hump and uniformly inclined water surface by Thacker (1981). It turns out that the qualitative behavior of sloshing caused by relaxing the external force which makes a free surface convex or uniformly inclined is successfully simulated even though phase error is visible and an inundation height shrinks as numerical simulation more proceeds. For the more severe test, we also simulate the nonlinear shoaling and refraction over uniform beach of wedge shape. It is shown that numerically simulated waves are less refracted than the linear counterpart by Hamiltonian ray theory due to nonlinearity, energy dissipation at the bottom and side walls, energy loss induced by breaking, and the hydraulic jump occurring when breaking waves encounter a down-rush by the preceding wave.

Fast Defect Detection of PCB using Ultrasound Thermography (초음파 서모그라피를 이용한 빠른 PCB 결함 검출)

  • Cho, Jai-Wan;Jung, Hyun-Kyu;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.273-275
    • /
    • 2005
  • Active thermography is being used since several years for remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements were performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

  • PDF

Two Layer Modelling with Applications to Exchange Flow and Internal Tide (이층류 모델링의 교환류와 내부조석파 연구에의 적용)

  • Kang, Sok-Kuh;Abbott, Michael-B.;Heung, Jae-Lie;Yum, Ki-Dai
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.9 no.1
    • /
    • pp.9-23
    • /
    • 1997
  • A numerical study of a two-layer, stratified flow is investigated, using the implicit finite difference method in one dimension. The results of computational method have been tested and, in case of lock exchange flow, compared with the results of experimental data. The results of model experiments with various interfacial, bottom friction coefficients along with various time weighting factor of numerical scheme and dissipative interface are shown and discussed. Two-layer model experiment has been also carried out to investigate the generation and propagation characteristics of internal tidal wave over the steep bottom topography under stratified condition. The internal wave seems to well radiate through the downstream boundary under the experiments adopting radiation conditions both at two layers and only at upper layer, confirming the applicability of radiational boundary condition in stratified flows. It is also shown that the internal wave through the downstream boundary propagates more actively with increasing thickness of lower layer in the downstream. This implies that the potential tidal energy in the interface will depend upon the thickness of lower layer for the constant thickness of upper layer.

  • PDF

Arc Phenomena and Induced Voltage due to Inductive Energy of Superconducting Coil (초전도 코일의 유도성 에너지에 의한 아크현상과 유기 과전압)

  • 최병주;류경우;성기철;김해종
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.24-30
    • /
    • 2000
  • This paper present the characteristics of the internal induced voltage and arc phenomena in liquid helium at the energy transfer from a superconducting magnet to a load resistor. Especially generation mechanism of the oscillated wave from of the coil terminal voltage is analyzed by considering circuit constant of the superconducting magnet, load condition and arc resistance of the mechanical opening switch. The wavefront and peak portion of the voltage are strongly influenced by arc discharge triggered by the switch separation in liquid helium. Abrupt arc extinction leads to voltage oscillation with an enormous peak. It is suggested that the superconducting magnet should be designed to ensure the internal surge when arc is possibly formed by switch opening or coil short circuit between turns or layers. Finally, a suppression method of the oscillating surge is proposed based on the load condition.

  • PDF

Primary Energy Conversion in a Direct Drive Turbine for Wave Power Generation

  • Prasad, Deepak Divashkar;Zullah, Mohammed Asid;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.237.1-237.1
    • /
    • 2010
  • Recent developments such as concern over global warming, depletion of fossil fuels and increase in energy demands by the increasing world population has eventually lead to mass production of electricity using renewable sources. Ocean contains energy in form of thermal energy and mechanical energy: thermal energy from solar radiation and mechanical energy from the waves and tides. The current paper looks at generating power using waves. The primary objective of the present study is to maximize the primary energy conversion (first stage conversion) of the base model by making some design changes. The model entire consisted of a numerical wave tank and the turbine section. The turbine section had three components; front guide nozzle, augmentation channel and the rear chamber. The augmentation channel further consisted of a front nozzle, rear nozzle and an internal fluid region representing the turbine housing. Different front guide nozzle configuration and rear chamber design were studied. As mentioned, a numerical wave tank was utilized to generate waves of desired properties and later the turbine section was integrated. The waves in the numerical wave tank were generated by a piston type wave maker which was located at the wave tank inlet. The inlet which was modeled as a plate wall which moved sinusoidally with the general function, $x=asin{\omega}t$. In addition to primary energy conversion, observation of flow characteristics, pressure and the velocity in the augmentation channel, rear chamber as well as the front guide nozzle are presented in the paper. The analysis was performed using the commercial code of the ANSYS-CFX. The base model recorded water power of 29.9 W. After making the changes, the best model obtained water power of 37.1 W which represents an increase of approximately 24% in water power and primary energy conversion.

  • PDF