• Title/Summary/Keyword: Internal gap

Search Result 412, Processing Time 0.023 seconds

10-GHz Band Voltage Controlled Oscillator (VCO) MMIC for Motion Detecting Sensors

  • Kim, Sung-Chan;Kim, Yong-Hwan;Ryu, Keun-Kwan
    • Journal of information and communication convergence engineering
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2018
  • In this work, a voltage controlled oscillator (VCO) monolithic microwave integrated circuit (MMIC) was demonstrated for 10-GHz band motion detecting sensors. The VCO MMIC was fabricated using a $2-{\mu}m$ InGap/GaAs HBT process, and the tuning of the oscillation frequency is achieved by changing the internal capacitance in the HBT, instead of using extra varactor diodes. The implemented VCO MMIC has a micro size of $500{\mu}m{\times}500{\mu}m$, and demonstrates the value of inserting the VCO into a single chip transceiver. The experimental results showed that the frequency tuning characteristic was above 30 MHz, with the excellent output flatness characteristic of ${\pm}0.2dBm$ over the tuning bandwidth. And, the VCO MMIC exhibited a phase noise characteristic of -92.64 dBc/Hz and -118.28 dBc/Hz at the 100 kHz and 1 MHz offset frequencies from the carrier, respectively. The measured values were consistent with the design values, and exhibited good performance.

Improvement of Ozone Yield by a Multi-Discharge Type Ozonizer Using Super position of Silent Discharge Plasma (무성방전의 중첩을 이용한 다중방전형 오존발생기의 오존생성수율 개선)

  • Song, Hyun-Jig;Lee, Dong-Heon;Oh, Jin-Hoon;Park, Seong-Wook;Seo, Young-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.88-91
    • /
    • 2004
  • In order to improve ozone generation, we experimentally investigated the silent discharge plasma and ozone generation characteristics of a multi-discharge type ozonizer. Ozone in a multi-discharge type ozonizer is generated by superposition of a silent discharge plasma, which is simultaneously generated in separated discharge spaces. A multi-discharge type ozonizer is composed of three different kinds of superposed silent discharge type ozonizers, depending on the method of applying power to each electrode. We observed that the discharge period of the current pulse for a multi-discharge type ozonizer can be longer than that of silent discharge type ozonizer with two electrodes and one gap.Hence, ozone generation is improved up to 17185 ppm and 783 g/kwh for the superposed silent discharge type ozonizer for which an AC high voltages with a 180 phase difference were applied to the internal electrode and the external electrode, respectively, with the central electrode being ground

  • PDF

The Impact of Internal Control on the Security and Usefulness of EDI System (EDI시스템에 있어서 내부통제가 정보시스템 보안성 및 유용성에 미치는 영향)

  • Han, In-Goo;Lee, Jae-Chang
    • Asia pacific journal of information systems
    • /
    • v.9 no.3
    • /
    • pp.143-157
    • /
    • 1999
  • EDI is one of the most important information technologies in todays business environment. This study is an exploratory study on the EDI control of Korean companies in their early stage of EDI implementation. The purpose of this study is to examine the impact of EDI controls on the security and usefulness of EDI systems for Korean companies who have adopted EDI. The data of fifty-one Korean companies for financial, manufacturing, and trade industries are collected by the mail survey and interview methods. The level of EDI control is mediocre on the average. The level of EDI security is low while that of EDI usefulness is mediocre. The empirical results show that the EDI controls in general improve the EDI security and usefulness significantly. Especially, the application and security control affect the EDI security significantly while the management, application, and security controls affect the EDI usefulness significantly. The gap between the level and perceived importance of control does not affect the EDI security but decreses the EDI usefulness at the marginal level of significance. The limitation of this study is that only a small number of companies are available for data collection because Korea is in the early stage of EDI implementation.

  • PDF

Identification of Fungus-infected Tomato Seeds Based on Full-Field Optical Coherence Tomography

  • Bharti, Bharti;Yoon, Taeil;Lee, Byeong Ha
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.571-576
    • /
    • 2019
  • The morphological changes of anthracnose (fungus) -infected tomato seeds have been studied to identify the infection and characterize its effect. Full-field optical coherence tomography (FF-OCT) has been utilized as a nondestructive but efficient modality for visualizing the effects of fungal infection. The cross-sectional images extracted from a stack of en face FF-OCT images showed significant changes with infection in the seed structure. First of all, the seed coat disappeared with the infection. The thickness of the seed coat of a healthy seed was measured as 28.2 ㎛, with a standard deviation of 1.2 ㎛. However, for infected seeds the gap between surface and endosperm was not appreciably observed. In addition, the measurements confirmed that the dryness of seeds did not affect the internal seed structure. The reconstructed three-dimensional (3D) image revealed that the permeability of the seed coat, which plays the vital role of protecting the seed, is also affected by the infection. These results suggest that FF-OCT has good potential for the identification of fungus-infected tomato seeds, and for many other tasks in agriculture.

Histopathology of a microspridian infection in ayu, Plecoglossus altivelis, from southern Korea (양식 은어의 미포자충 감염예에 대한 병리조직학적 관찰)

  • Jo, Byeong-Yeol;Gang, Hyeong-Gil;Gang, Hyo-Ju;Ryu, Gap-Min;Lee, Jae-Yeong;Park, Nam-Gyu;Heo, Min-Do
    • Journal of fish pathology
    • /
    • v.16 no.1
    • /
    • pp.23-30
    • /
    • 2003
  • On September in 1998, a microsporidian infection was recognized in ayu, Plecoglossus altivelis, farmed on Kyongnam province of South Korea. Cumulative mortality was around 10% in 10 days. Infected fish which were piping for air near the surface of the water or in the asphyxic, lethargic condition revealed darkening of body and abdominal distention. Numerous whitish nodules up to 3mm in size were observed throughout most of body organs and tissues including gill, operculum, peritoneal wall and organs. Xenomas were also histologically confirmed in multiple internal organs with the evidences suggesting circulatory disturbance. Based on the morphology of spore and xenoma, and the distribution of xenomas in organs and tissues, this disease was diagnosed to be a microsporidiosis caused by Glugea plecoglossi. The mortality might be deeply related to the local circulatory disturbance by xemonas rather than the mechano-chemical effect of xenomas on adjacent tissues.

CHANGE OF CHANNEL-FLOW TOPOLOGY BY A STREAMWISE-PERIODIC ARRAY OF ROTATING CIRCULAR CYLINDERS (주기적으로 배열된 회전하는 원형 실린더를 이용한 채널유동 토폴로지 변화)

  • Jeong, Taekyeong;Yang, Kyung-Soo;Lee, Kyongjun;Kang, Changwoo
    • Journal of computational fluids engineering
    • /
    • v.18 no.4
    • /
    • pp.17-24
    • /
    • 2013
  • In this study, we consider the characteristics of channel flow in the presence of an infinite streamwise array of equispaced identical rotating circular cylinders. This flow configuration can be regarded as a model representing a micro channel or an internal heat exchanger with cylindrical vortex generators. A numerical parametric study has been carried out by varying Reynolds number based on the bulk mean velocity and the cylinder diameter, and the gap between the cylinders and the channel wall for some selected angular speeds. An immersed boundary method was employed to facilitate implementing the cylinders on a Cartesian grid system. No-slip condition is employed at all solid boundaries including the cylinders, and the flow is assumed to be periodic in the streamwise direction. The presence of the rotating circular cylinders arranged periodically in the streamwise direction causes a significant topological change of the flow, leading to increase of mean friction on the channel walls. More quantitative results as well as qualitative physical explanations are presented to justify the effectiveness of rotating cylinders to modify flow topology, which might be used to enhance heat transfer on the channel walls.

Theoretical modeling and analysis of thulium doped fluoride fiber amplifier at 1.47 $\mu\textrm{m}$ band amplification (툴륨이 첨가된 플루오르 계열의 광섬유 증폭기의 1.47$\mu\textrm{m}$ 증폭 대역에 대한 모델링과 분석에 대한 연구)

  • 이원재;민범기;박재형;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.171-178
    • /
    • 2000
  • We present a numerical model which enables to analyze $1.47mu$m amplification band characteristics for thulium doped fluoride fiber amplifiers. We focused on upconversion pumping scheme, thus many transitions affecting $1.47mu$m band amplification was considered simultaneously. Backward propagating waves and transverse mode were also considered in the model. The parameters for modeling were then acquired using published experimental data and related theories such as Judd-Ofelt theory for radiative transition, empirical energy gap law for non-radiative transition, and McCumber relations for cross-sections. The simulation showed well-matched results with experiment and internal dynamics. amics.

  • PDF

Comparison of Ideal versus Actual Fashion Corporate Social Responsibility from a Consumer Perspective (소비자 관점에서의 패션기업의 이상적 CSR과 실제적 CSR 비교)

  • Ahn, Soo-Kyoung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.5
    • /
    • pp.631-644
    • /
    • 2013
  • This study investigates the gaps between ideal and actual corporate social responsibility (CSR) by comparing levels of CSR perceptions and examining the relationship differences between CSR perception, perceived quality, and affective trust from a consumer perspective. Data from 315 adult samples were collected through a nationwide online survey. In order to compare ideal and actual CSR, the study employed the approach of latent means analysis (LMA) and multi-group comparisons within the framework of a structural equation modeling (SEM). The result of latent means comparison showed significant differences of perceptions on fashion CSR across ideal and actual contexts. Only actual economic CSR was evaluated higher than in the ideal context and the effect size of inter-management CSR was the largest among seven domains. Multi-group SEM revealed a significant discrepancy between ideal and actual CSR structural models that exhibited relationships of CSR perception, perceived quality, and affective trust. The paths from internal management and ethical CSR to perceived quality and from economic and philanthropy CSR to affective trust were different across ideal and actual contexts. Implying the understanding of consumer CSR perceptions and the mediating role of perceived quality, this study suggests that marketers narrow the gap between ideal and actual CSR.

Humidity Distribution and Performance Variation of a PEMFC Multi Stack System According to the Direction of Anodic Supply (고분자 전해질 연료전지 멀티 스택 시스템의 수소극 흐름방향에 따른 습도분포 및 성능변화)

  • Lee, Yongtaek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.143-148
    • /
    • 2018
  • In this study the performance and humidity variation for 2 unit cells connected in series were experimentally measured. The relative flow direction of hydrogen and air was changed from parallel flow to counter flow. Internal humidity distribution was then measured by 5 embedded sensors on each channel. In all experimental conditions, the former unit cell showed a better performance and the gap is noted to be higher when counter flow is applied. The performance was noted to be higher at high humidification case in the parallel flow. However, in the counter flow, the difference of performance according to the humidification is negligible. Hydrogen and air are discharged from the PEMFC unsaturated with water vapor at parallel flow/low humidification condition, which explains lower performance of the PEMFC than other conditions. The humidities in hydrogen and air streams of counter flow were noted to increase rapidly even at low humidification condition and the consequential even hydration of membrane is the reason of higher performance.

Optoelectronics Properties of In0.27Ga0.73N/GaN Multi-Quantum-Well Structure (In0.27Ga0.73N/GaN 다중 양자우물 구조에 대한 광전기적 특성)

  • Park, Hun-Bo;Bae, In-Ho;Kim, Ki-Hong
    • Korean Journal of Materials Research
    • /
    • v.17 no.9
    • /
    • pp.489-492
    • /
    • 2007
  • Temperature and injection current dependence of elctroluminescence(EL) spectral intensity of the $In_{0.27}Ga_{0.73}N/GaN$ multi-quantum-well(MQW) have been studied over a wide temperature and as a function of injection current level. EL peaks also show significant broadening into higher photon energy region with the increase of injection current. This is explained by the band-filling effect. When temperature is slightly increased to 300 from 15 K, the EL emission peak showed red-blue-red shift. It can be explained by the carrier localization by potential fluctuation of multiple quantum well and band-gap shrinkage as temperature increase. It is found that a temperature-dependent variation pattern of the EL efficiency under very low and high injection currents show a drastic difference. This unique EL efficiency variation pattern with temperature and current is explained field effects due to the driving forward bias in presence of internal(piezo and spontaneous polarization) fields.