• Title/Summary/Keyword: Internal flow control

Search Result 356, Processing Time 0.029 seconds

Clinical study of blood flow and vascular reaction in Taeumin CVA patients using Transcranial Doppler (Transcranial Doppler를 이용(利用)한 태음인 중풍환자의 혈류속도(血流速度)와 혈관(血管) 반응성(反應性)에 대한 임상적(臨床的) 고찰(考察))

  • Lim, Jong-Pil;Bae, Na-Young;Han, Kyung-Soo;Ahn, Taek-Won
    • Journal of Haehwa Medicine
    • /
    • v.15 no.2
    • /
    • pp.263-272
    • /
    • 2006
  • Purpose Brain vessles have autoregulation function, so even when perfusion pressure drops, cerebral blood flow remain stable by vasodilation. Latest research on this reserve of cerebral vessels is being done using TCD, which measures the reserve of the vessels. We did a research comparing cerebral vessel and peripheral vessel reserve between Taeumin, who are more likely to suffer CVA, and the normal. We observed blood flow of Internal carotid artery siphon and radial indicis artery of the two group with TCD. Method We picked 20 people out of patients diagnosed as cerebral infarction at Cheon-An Oriental hospital of Daejeon University. They were diagnosed as Taeumin with QSCCII questionnaire and constitutional differentiation. Using TCD, we measured highest blood flow rate, mean blood flow and asymmetric counting blood flow of Internal carotid artery siphon and radial indicis artery at rest. And then we measured again after stimulating cerebral vessels, by triggering hypercapnia by self apnea and peripheral vessels by palm heating. Result At rest, mean blood flow rate of Internal carotid artery siphon showed significant decrease compared to control group. Blood flow rate of Internal carotid artery siphon after hypercapnia showed significant decline in highest blood flow rate and mean blood flow compared to control group. Cerebral vessel reaction after the hypercapnia induction showed great change in experiment group than the control group. Peripheral vessel reaction after palm heating showed significant decline in experiment group compared to control group. Conclusion In conclusion, measuring the alteration of blood flow used in diagnosing cerebral infarction, is more sensitive when vessel stimulation is done. Non-invasive TCD is effective especially in case of Taeumin who are more likely to suffer vascular disorder than others.

  • PDF

The Effect of Silver Spike Point Therapy(SSP) that applied to Acupoints on the Blood Flow Rate of Internal Carotid Artery and Pain Relief of Headache Patients

  • Seo, Hyo-Seok;Lee, Yoon-Ho;Yun, Young-Dae;Moon, Ok-Kon;Kim, Ji-Sung;Choi, Suk-Ju;Choi, Yoo-Rim;Zoo, Suk-Bum;Kim, Soon-Hee
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.1
    • /
    • pp.251-259
    • /
    • 2011
  • The aim of this is to examine the effects of SSP therapy on the internal carotid arteries blood flow of 24 tension type headache patients(study group) and non tension type headache patients(control group), and on the reduction of their headaches, when applied to the acupuncture points. It stimulated the acupuncture point of headache 6 place with the SSP. It measured VAS and the blood flow of the internal carotid arteries with TCD. When the internal carotid arteries blood flow of study group and control group were compared by period, a significant difference was found in the 4th period(p<.05). When the Visual Analog Scale of study group and control group were compared by period, a significant difference was found in the 4th period(p<.05). The comparison of each measurement result of the internal carotid arteries blood flow of the study group found significantly increased. The comparison of each measurement result of the VAS of study group found significantly decreased. With regard to the control group, the VAS significantly decreased. The silver spike point low frequency electrical stimulation treatment, when applied to the acupuncture point, can significantly influence the internal carotid arteries blood flow of headache patients and can significantly reduce their headaches.

Internal Flow Analysis and Structural Design in Plastic Automatic Control Valve for the Semiconductor Chemical Liquid (반도체 약액용 자동제어 플라스틱 밸브의 내부 유동해석)

  • Lee, Gyu-Hoon;Lee, Eung-Suk;Lee, Min-Ki;Kim, Jin-Su;Bae, Il-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.311-315
    • /
    • 2012
  • Diaphragm type noncontact automatic control valve is a valve for controling acidic PR(Photo Resist) liquid used in the semiconductor process. PR is photosensitive liquid that changes phases depending on light transmittance. PR is very toxic and expensive; the purpose of this paper is to address methods that prevent loss due to leaks. The design of noncontact precise automatic control valve is expected to play an important role in controlling fluid flow, therefore influencing energy conservation and environmental improvement. In this paper, diaphragm type automatic control valve's part design, assembly and simulation are introduced. Also, through the analysis of fluid flow the valve's internal velocity, pressure, and turbulent intensity are interpreted. This paper proposes to contribute to the improvement of the valve's performance.

A Study on the Numerical Analysis of Internal Flow in a Cone Type Valve (Cone Type 밸브 내부유동 수치해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.199-207
    • /
    • 2020
  • These days, many different types of valves are developed in the industrial area according to their use purpose. Multiple kinds of valves are installed to control a flow and pressure of the pipe conveying fluid. Valves serve as critical roles in land plants such as power plants. The performance of equipment varies depending on valve characteristics. In this study, the internal flow analysis on Cone-type valve is conducted to analyze flow field and secure a value of the flow coefficient Cv. According to the internal flow analysis, when the flow distribution of the middle cross-section of valve was open 100%, flow field was relatively and smoothly taken out. If it was open 50%, flow recirculation region increased and a little complex flow field occurred. Unlike ball valve or butterfly valve, this valve had flow recirculation in its outlet depending on a valve opening amount. Therefore, it was found that there was no flow recirculation in the outlet of Cone-type valve.

Evaluation on Tongue Coating, Volatile Sulfur Compounds, Salivary Flow Rate and Secretory Immunoglobulin A in Saliva in Patients with Oral Malodor (구취환자의 설태, 휘발성 황화합물, 타액분비율 및 타액내 secretory Immunoglobulin A에 대한 평가)

  • Kim, Jin-Sung;Eom, Guk-Hyeon
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.1
    • /
    • pp.258-264
    • /
    • 2008
  • Objectives : The aim of this study was to confirm the characteristics of oral malodor patients by evaluating the differences of salivary flow rate, secretory immunoglobulin A (sIgA) level in saliva between the patient and control groups, and the correlation with the tongue coating, volatile sulfur compound (VSC), salivary flow rate and sIgA level in saliva in the patients group. Methods : Forty-seven patients with oral malodor and twenty healthy volunteers were included in this study. Their tongue coating was assessed with the Winkel tongue coating index, and salivary flow rate, sIgA concentrations in saliva and the level of VSC in oral cavity were measured. Results : There were no significant differences of the salivary flow rate and the sIgA level in saliva between the patient and control groups, but there was a significant relationship between the accumulation of tongue coating and the level of VSC in oral cavity. Conclusions : Our results suggest that tongue coating is closely related to oral malodor, but further studies are needed to confirm the relationship between tongue coating and sIgA level in saliva.

  • PDF

Flow Characteristics of Cryogenic Butterfly Valve for LNG Carrier (Part 1 : CFD Analysis and its Comparison with Experimentation) (LNG선용 버터플라이밸브의 유동특성에 관한 연구 (제1부 : CFD해석과 실험결과의 비교))

  • Kim, Sang-Wan;Choi, Young-Do;Kim, Jung-Hwan;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.2
    • /
    • pp.13-19
    • /
    • 2008
  • Butterfly valves are widely used as control valves for industrial process. For the definition of optimum configuration of the valve, wide range of related studies has been actively conducted in the case of working fluids of water or air under the normal temperature. Recently, internal flow and performance characteristics of cryogenic butterfly valve for LNG carrier take a growing interest in the field of research and development. Therefore, present study is aimed to investigate the internal flow and performance characteristics of the cryogenic butterfly valve because the study result for the valve can be hardly found at present. Part 1 of this paper describes the study result of a butterfly valve model under the condition of the normal temperature. Succeeding Part 2 of this paper will describe the internal flow characteristics of a cryogenic butterfly valve for LNG carrier. The results of Part 1 show that pressure loss coefficients and flow rate coefficients obtained by the present experiment and CFD analysis agree well each other. Moreover, internal flow visualization for the valve by CFD analysis and PIV measurement have revealed complicated flow patterns of the internal flow field in detail.

Study of the Internal Flow and Evaporation Characteristic Inside a Water Droplet on a Vertical Vibrating Hydrophobic Surface (수직 진동을 이용한 가열된 고체표면 위 증발하는 액적의 내부유동 제어연구)

  • Park, Chang-Seok;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.37-46
    • /
    • 2017
  • Thermal Marangoni flow has been observed inside droplets on heated surfaces, finally resulting in a coffee stain effect. This study aims to visualize and control the thermal Marangoni flow by employing periodic vertical vibration. The variations in the contact angle and internal volume of the droplet as it evaporates is observed by using a combination of continuous light and a still camera. With regard to the internal velocity, the particle image velocimetry system is applied to visualize the internal thermal Marangoni flow. In order to estimate the internal temperature gradient and surface tension on the surface of a droplet, the theoretical model based on the conduction and convection theory of heat transfer is applied. Thus, the internal velocity increases with an increase in plate temperature. The flow directions of the Marangoni and gravitational flows are opposite, and hence, it may be possible to control the coffee stain effect.

Vibration Control and Dynamic Stability of Pipes by means of Internal Flowing Fluid (내부 유동유체에 의한 송수관의 동적안정성과 진동제어)

  • 류봉조;정승호;엄재섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.550-554
    • /
    • 1995
  • The present paper deals with the dynamic stability and vibration suppression of a cantilevered flexible pipe with a concetrated mass under an internal fluid flow. The equations of motion are derived by energy expressions using Hamilton's pronciple, and some analytical results using Galerkin's method are presented. Finally, the vibration suppression technique by means of an internal fluid flow is demonstrated experimentally.

  • PDF

An experimental analysis of the fluid flow in an automobile HVAC system using a PIV technique (PIV기법을 이용한 차량용 공조 시스템 내부유동에 대한 실험적 연구)

  • Ji, Ho-Seong;Kim, Bo-Ram;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.92-96
    • /
    • 2007
  • Internal flow characteristics for an automobile HVAC have been investigated using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser(125 mJ), a high-resolution CCD camera($2K\;{\times}\;2K$), optics and a synchronizer. An automobile HVAC module was used directly. Only the casing was remodeled transparently for capturing flow image and laser sheet beam illumination. Time-averaged velocity field were measured in three temperature control mode. For three temperature control modes, the internal flow characteristics for an automobile HVAC system were evaluated from PIV results..

  • PDF

CFD Analysis on the Internal Air Flow Control in a Wax Spin Coater of Silicon Wafer Polishing Station (실리콘 웨이퍼 연마장비용 왁스 스핀코팅장치의 내부기류 제어에 관한 전산유동해석)

  • Kim, Kyoung-Jin;Kim, Dong-Joo;Park, Joong-Youn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • In this paper, the air flow induced by the rotating flat disk is numerically investigated in a hope to better understand the air flow structures inside the wax spin coater for a silicon wafer polishing station. Due to the complex inner geometry of actual spin coater such as the casing around the rotating ceramic block and servo motor, recirculation of air flow is inevitably found on the coating target if the internal space of spin coater is closed at the bottom and it could be the possible source of contamination on the wax coating. By numerical flow simulation, we found that it is necessary to install the air vent at the bottom and to apply the sufficient air suction in order to control the path of air flow and to eliminate the air recirculation zone above the spinning surface of coating target.