• 제목/요약/키워드: Internal fixation with plate

검색결과 108건 처리시간 0.023초

쇄골 간부골절의 전하방 부착 재구성 금속판을 이용한 치료 (Anterior inferior reconstruction plate on acute midshaft clavicle fvacture)

  • 강재도;김광열;김형천;임문섭;김성훈;권준형
    • Clinics in Shoulder and Elbow
    • /
    • 제6권1호
    • /
    • pp.44-49
    • /
    • 2003
  • Purpose: Many different operative technique of mid-shaft clavicle fracture have been reported. The aim of this prospective study was to compare the results of anterior or anterior-inferior plating with superior plating on the acute mid-shaft fracture of clavicle Materials and Methods: From February1997 to February 2002, thirty-eight consecutive open reduction and internal fixation with reconstruction plates were performed in thirty-eight patients. from August 1999, anterior or anterior-inferior plating was mainly used, prospectively. The duration of follow-up averaged 17 months (range,23 to 43 months). The mean age was 38 years old (range,21 to 57 years old) on anterior or anterior-inferior plating group and 35 years old (range,24 to 55 years old) on superior plating group. The physician progress note, VAS patient complement score, Roentgenogram and ASES score was evaluated. Results: Four patients were lost to follow-up. There was no statistical difference on mean radiological bone union time (8.7 weeks vs. 8.6 weeks) and ASES score (92 vs 94) at inferior and superior plating groups (P > 0.05). VAS patient complement score was very good or excellent on anterior or anterior-inferior group, average score was 1.1 (ranger,0 to 2) compare with superior plating group (P < 0.05). There were two cases of infection, 1 case of failed fixation on superior plating group and 1 case of delayed union on anterior inferior plating group. Conclusion: Anterior inferior plating on acute clavicle midshaft fracture results in excellent patient complement score compare with conventional superior reconstruction plate.

Subbrow Approach as a Minimally Invasive Reduction Technique in the Management of Frontal Sinus Fractures

  • Lee, Yewon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.679-685
    • /
    • 2014
  • Background Frontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are still controversial. In this article, we suggest a simple reduction method using a subbrow incision as a treatment for isolated anterior sinus fractures. Methods Between March 2011 and March 2014, 13 patients with isolated frontal sinus fractures were treated by open reduction and internal fixation through a subbrow incision. The subbrow incision line was designed to be precisely at the lower margin of the brow in order to obtain an inconspicuous scar. A periosteal incision was made at 3 mm above the superior orbital rim. The fracture site of the frontal bone was reduced, and bone fixation was performed using an absorbable plate and screws. Results Contour deformities were completely restored in all patients, and all patients were satisfied with the results. Scars were barely visible in the long-term follow-up. No complications related to the procedure, such as infection, uncontrolled sinus bleeding, hematoma, paresthesia, mucocele, or posterior wall and brain injury were observed. Conclusions The subbrow approach allowed for an accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by providing a direct visualization of the fracture. Considering the surgical success of the reduction and the rigid fixation, patient satisfaction, and aesthetic problems, this transcutaneous approach through a subbrow incision is concluded to be superior to the other reduction techniques used in the case of an anterior table frontal sinus fracture.

Rib Fixation for a Patient with Severely Displaced and Overlapped Costal Cartilage Fractures

  • Han, Sung Ho;Chon, Soon-Ho;Lee, Jong Hyun;Lee, Min Koo;Kwon, Oh Sang;Kim, Kyoung Hwan;Kim, Jung Suk;Lee, Ho hyoung
    • Journal of Trauma and Injury
    • /
    • 제31권1호
    • /
    • pp.12-15
    • /
    • 2018
  • Rib fixations for flail chest or displaced rib fractures are not a new technique. However, reports on rib fixations involving costal cartilage fractures are very few and surprisingly there are no reports of internal fixations involving only the costal cartilage in the English literature. The diagnosis is difficult and the necessity of the procedure may be quite controversial. Placing plates in screws into the costal cartilage alone may seem unstable and easily dislodged or stripped through the cartilage. We report a 31-year-old male scuba diver instructor who underwent rib fixations over his 7th and 8th costal cartilage ribs for severe pain. The procedure was done with conventional plates and screws. He had the plates and screws removed 2 months later due to lingering pain, but with them removed he is now quite happy with the results without pain. The procedure for fixation of painful overlapped costal cartilage is quite simple and can be done with the usual conventional methods, fixating plate and screws directly over the cartilage alone without fixation over the bony rib.

상완골 경부 이분 골절에서 T형 금속판을 이용한 치료 (Treatment of Two-Part Fracture of Humerus Neck Using T Plate Fixation)

  • 남일현;안길영;윤호현;김재철;문기혁
    • Clinics in Shoulder and Elbow
    • /
    • 제9권1호
    • /
    • pp.34-41
    • /
    • 2006
  • Purpose: This study is to analyze the result and complications of internal fixation with T-plate for two-part fracture of the neck of the humerus. Materials and Methods: The clinical results of fourteen patients who had been performed with this method mentioned above were reviewed. Their average age was 49.6. Postoperative mean follow up period was 24.1 months. Radiological evaluation was done by Kronberg's and shoulder function by Neer's. Results: By Kronberg evaluation, nine cases were good, two cases acceptable and three cases poor. By Neer's, mean score of shoulder function was 77.6 and 4 cases were excellent, one satisfactory, five unsatisfactory and four failure. The complications were the sfiff shoulder, loss of reduction and avascular necrosis of humeral head. Conclusion: In this study, there were differences according to the age. And we obtained an unsatisfactory result in patients over 50 years old. We consider that in patients over 50 years old, the differences were due to the muscle weakness through wide surgical approaches, postoperative implant loosening or the stiffness caused by poor rehabilitation.

Application of Minimally Invasive Plate Osteosynthesis to Tibial Shaft Fractures in Dogs

  • Rahman, Md. Mahbubur;Jeong, In-Seong;Kim, Nam Soo
    • 한국임상수의학회지
    • /
    • 제34권3호
    • /
    • pp.200-203
    • /
    • 2017
  • The objective of this study was to evaluate the effectiveness of the minimally invasive plate osteosynthesis (MIPO) method for treatment of tibial shaft fractures in dogs by comparing MIPO radiographic and fracture healing time results with those from the popular open reduction and internal fixation (ORIF) technique. In this clinical study at the Royal Animal Medical Center, five consecutive dogs with diagnoses of comminuted tibial shaft fractures were treated with the MIPO surgical approach. For comparison, an additional five breed-, age-, and weight-matched dogs with comminuted tibial shaft fractures were treated with the ORIF technique. Mean healing time was $75.6{\pm}12.5$ days in the MIPO group and $131.8{\pm}18.6$ days in the ORIF group (p < 0.01). The mean surgery time in the MIPO group ($36.4{\pm}3.5$ minutes) was significantly shorter (p < 0.01) than that for the ORIF group ($47.0{\pm}2.2$ minutes). Based on the short surgical and healing times, the MIPO approach is clinically superior to the ORIF approach and should be the preferred approach in tibial fracture cases.

Effect of Surgical-Site, Multimodal Drug Injection on Pain and Stress Biomarkers in Patients Undergoing Plate Fixation for Clavicular Fractures

  • Yoo, Jae-Sung;Heo, Kang;Kwon, Soon-Min;Lee, Dong-Ho;Seo, Joong-Bae
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.455-461
    • /
    • 2018
  • Background: Surgical-site, multimodal drug injection has recently evolved to be a safe and useful method for multimodal pain management even in patients with musculoskeletal trauma. Methods: Fifty consecutive patients who underwent plating for mid-shaft and distal clavicular fractures were included in the study. To evaluate whether surgical-site injections (SIs) have pain management benefits, the patients were divided into two groups (SI and no-SI groups). The injection was administered between the deep and superficial tissues prior to wound closure. The mixture of anesthetics consisted of epinephrine hydrochloride (HCL), morphine sulfate, ropivacaine HCL, and normal saline. The visual analogue scale (VAS) pain scores were measured at 6-hour intervals until postoperative hour (POH) 72; stress biomarkers (dehydroepiandrosterone sulfate [DHEA-S], insulin, and fibrinogen) were measured preoperatively and at POH 24, 48, and 72. In patients who wanted further pain control or had a VAS pain score of 7 points until POH 72, 75 mg of intravenous tramadol was administered, and the intravenous tramadol requirements were also recorded. Other medications were not used for pain management. Results: The SI group showed significantly lower VAS pain scores until POH 24, except for POH 18. Tramadol requirement was significantly lower in the SI group until POH 24, except for POH 12 and 18. The mean DHEA-S level significantly decreased in the no-SI group ($74.2{\pm}47.0{\mu}g/dL$) at POH 72 compared to that in the SI group ($110.1{\pm}87.1{\mu}g/dL$; p = 0.046). There was no significant difference in the insulin and fibrinogen levels between the groups. The correlation values between all the biomarkers and VAS pain scores were not significantly different between the two groups (p > 0.05). Conclusions: After internal fixation of the clavicular fracture, the surgical-site, multimodal drug injection effectively relieved pain on the day of the surgery without any complications. Therefore, we believe that SI is a safe and effective method for pain management after internal fixation of a clavicular fracture.

Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates

  • Doh, GyeongHyeon;Bahk, Sujin;Hong, Ki Yong;Lim, SooA;Han, Kang Min;Eo, SuRak
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.143-147
    • /
    • 2018
  • We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The displaced bones were treated by open reduction and internal fixation successfully using bioabsorbable plate system. However, at postoperative 11 months, abrupt painless swelling was noted on the previous operation sites, left lateral eyebrow and lower eyelid. By surgical exploration, pus-like discharge and degraded materials were observed and debrided. The pathologic analysis revealed foreign body reaction with sterile abscess. This complication followed by bioabsorbable device implantation on maxillofacial bone surgery has been rarely reported in which we call attention to the maxillofacial plastic surgeons.

Unrecognized bony Bankart lesion accompanying a dislocated four-part proximal humerus fracture before surgery: a case report

  • Lee, Seungjin;Shin, Daehun;Hyun, Yoonsuk
    • Clinics in Shoulder and Elbow
    • /
    • 제25권1호
    • /
    • pp.68-72
    • /
    • 2022
  • Proximal humerus fractures are the third most common fractures, totaling 4% to 5% of all fractures. Here, we present the case of a 39-year-old man with a dislocated four-part fracture of the proximal humerus with a huge bony Bankart lesion. Preoperatively, the bony Bankart lesion of the glenoid was not visualized on computed tomography scans or magnetic resonance imaging because the fracture of the proximal humerus was comminuted, displaced, and complex. It was planned for only the humerus fracture to be treated by open reduction and internal fixation using a locking plate. However, a fractured fragment remained under the scapula after reduction of the dislocated humeral head. This was mistaken for a dislocated bone fragment of the greater tuberosity and repositioning was attempted. After failure, visual confirmation showed that the bone fragment was a piece of the glenoid. After reduction and fixation of this glenoid part with suture anchors, we acquired a well-reduced fluoroscopic image. Given this case of complex proximal humerus fracture, a glenoid fracture such as a bony Bankart lesion should be considered preoperatively and intraoperatively in such cases.

Evaluation of postoperative complications according to treatment of third molars in mandibular angle fracture

  • Lim, Hye-Youn;Jung, Tae-Young;Park, Sang-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권1호
    • /
    • pp.37-41
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the implication of third molars in postoperative complications of mandibular angle fracture with open reduction and internal fixation (ORIF). Materials and Methods: Data were collected on patients who presented with mandibular angle fracture at our Department of Oral and Maxillofacial Surgery between January 2011 and December 2015. Of the 63 total patients who underwent ORIF and perioperative intermaxillary fixation (IMF) with an arch bar, 49 patients were identified as having third molars in the fracture line and were followed up with until plate removal. The complications of postoperative infection, postoperative nerve injury, bone healing, and changes in occlusion and temporomandibular joint were evaluated and analyzed using statistical methods. Results: In total, 49 patients had third molars in the fracture line and underwent ORIF surgery and perioperative IMF with an arch bar. The third molar in the fracture line was retained during ORIF in 39 patients. Several patients complained of nerve injury, temporomandibular disorder (TMD), change of occlusion, and postoperative infection around the retained third molar. The third molars were removed during ORIF surgery in 10 patients. Some of these patients complained of nerve injury, but no other complications, such as TMD, change in occlusion, or postoperative infection, were observed. There was no delayed union or nonunion in either of the groups. No statistically significant difference was found between the non-extraction group and the retained teeth group regarding complications after ORIF. Conclusion: If the third molar is partially impacted or completely nonfunctional, likely to be involved in pathologic conditions later in life, or possible to remove with the plate simultaneously, extraction of the third molar in the fracture line should be considered during ORIF surgery of the mandible angle fracture.

Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

  • Santos, Zarina Tatia Barbosa Vieira;Goulart, Douglas Rangel;Sigua-Rodriguez, Eder Alberto;Pozzer, Leandro;Olate, Sergio;Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권2호
    • /
    • pp.77-82
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance ($162.72{\pm}42.55N$), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.