• Title/Summary/Keyword: Internal finish

Search Result 39, Processing Time 0.025 seconds

An Experimental Study on the Development of Fire-retardant Treated Wood for Construction (건축용 난연 목재 개발에 대한 실험 연구)

  • Seo, Hyun Jeong;Kim, Nam Kyun;Jo, Jeong Min;Lee, Min Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.149-156
    • /
    • 2017
  • This study investigates fire-retardant performances and combustion/thermal characteristics of fire-retardant treated wood by comparing them with those of fire-retardant untreated wood from the expreimental resutls of cone calorimeter and thermo-gravimetric(TG) analyzer. Hazardousness of combustion product gases for fire-retardant treated wood and untreasted wood were also observed from the results of internal finish material incombustibility test according to the Korea standard code of KS F 2271. In this study, we also tried to improve the fire retardant performance of wood by applying fire-retardant chemical composites, and to secure the fire safety performance in buildings. Red pine (Pinus densiflora) was selected as a test specimen because it is mostly used as a building material in Korea. Fire retardant chemical composites (FRCs) were prepared by mixing boron, phosphorous, and nitrogen species and treated by press-impregnation method. Water-based FRCs were composed of 3% boric acid($H_3BO_3$), 3% borax decahydrate($Na_2B_4O_7$), 8% ammonium carbonate($(NH_4)_2CO_3$), diammonium phosphate ($(NH_4)_2HPO_4$) varied from 10-30% and potassium carbonate($K_2CO_3$) varied from 10-30%. From the test results of cone calorimeter, TG analysis and gas hazard assessments, newly proposed were the optimal composition and production methods of FRCs which can sufficiently meet fire-retardant level 3 based on Korea law of construction. Thus, the FRCs, developed in this study, are anticipated to contribute to the improvement of fire safety and widespread of usage in wood as building materials.

Research on Increasing the Production Yield Rate by Six Sigma Method : A Case of SMT Process of Main Board

  • Lin, Ching-Kun;Chen, Hsien-Ching;Li, Rong-Kwei;Chen, Ching-Piao;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • v.10 no.1
    • /
    • pp.1-23
    • /
    • 2009
  • Face the process yield rate improvements of motherboard, although general enterprises finish deployment goal of each functions by overall quality managements, through quality improvement methods, industry engineering methods, plan-do-check-act (PDCA) methods and other improvement solutions, but it is only can be improved partially and unable to enhance the yield rate of product to the target. It only can takes one step ahead to enhance the process yield rate of motherboard with six sigma ($6{\sigma}$) overall DMAIC process and tactics. This research aimed to use six sigma quality improvement tactics by DMAIC systematic procedure and tactics, and find the key factors that effect to the process yield rate of surface mount technology. It also identified the keys input and process and output index to satisfy customer requirements and internal process index. The results showed that the major effective factors by fishbone and process failure modes and effects analysis (PFMEA). If the index of input and output that can be quantified, the optimum parameter can be found through design of experiment to ensure that the process is stable. If the factor of input and output that cannot be quantified, we found out the effective countermeasure by Mind_Mapping, make sure whole processes can be controlled stably, to reach the high product quality and enhance the customer satisfaction.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS (내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구)

  • Kim Yu-Lee;Cho Hye-Won;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

Experimental Study on the Development of Void Precast Concrete Slab using Rubber Tube Mold for Inner Core (고무튜브 몰드 프리캐스트 콘크리트 유공 슬래브 개발에 관한 실험적 연구)

  • Bae, Kyu-Woong;Hong, Sung-Yub
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.293-303
    • /
    • 2021
  • The void PC slab has a structurally reasonable cross-section by forming the hollow section of the neutral axis that is unnecessary for bending behavior. Domestic PC factories have introduced automation equipment to produce hollow PC slabs, and are achieving hollow sections through inserts. However, since the excessive initial investment cost of the PC factory is the main factor in the increase in production cost, other alternatives are needed. Therefore, in this study, when producing hollow PC slab members, by using a rubber tube as a formwork to form an internal hollow space, it is intended to contribute to securing productivity through molding various hollow shapes, making it larger, lightweight, and enabling rapid production. To implement a hollow PC slab using a rubber tube mold, the shape of a hollow cross-section in which the tube is combined was implemented by considering the shape of the rubber tube first. In addition, to secure the concrete quality of the hollow part, the finish properties of the rubber tube mold and concrete were evaluated, and the hollow PC production process was established.

Performance of Korean State-owned Enterprises Following Executive Turnover and Executive Resignation During the Term of Office (공기업의 임원교체와 중도퇴임이 경영성과에 미치는 영향)

  • Yu, Seungwon;Kim, Suhee
    • KDI Journal of Economic Policy
    • /
    • v.34 no.3
    • /
    • pp.95-131
    • /
    • 2012
  • This study examines whether the executive turnover and the executive resignation during the term of office affect the performance of Korean state-owned enterprises. The executive turnover in the paper means the comprehensive change of the executives which includes the change after the term of office, the change after consecutive terms and the change during the term of office. The 'resignation' was named for the executive change during the term of office to distinguish from the executive turnover. The study scope of the paper is restrained to the comprehensive executive change itself irrespective of the term of office and the resignation during the term of office. Therefore the natural change of the executive after the term of office or the change after consecutive terms is not included in the study. Spontaneous resignation and forced resignation are not distinguished in the paper as the distinction between the two is not easy. The paper uses both the margin of return on asset and the margin of return on asset adjusted by industry as proxies of the performance of state-owned enterprises. The business nature of state-owned enterprise is considered in the study, the public nature not in it. The paper uses the five year (2004 to 2008) samples of 24 firms designated as public enterprises by Korean government. The analysis results are as follows. First, 45.1% of CEOs were changed a year during the sample period on the average. The average tenure period of CEOs was 2 years and 3 months and 49.9% among the changed CEOs resigned during the term of office. 41.6% of internal auditors were changed a year on the average. The average tenure period of internal auditors was 2 years and 2 months and 51.0% among the changed internal auditors resigned during the term of office. In case of outside directors, on average, 38.2% were changed a year. The average tenure period was 2 years and 7 months and 25.4% among the changed internal directors resigned during the term of office. These statistics show that numerous CEOs resigned before the finish of the three year term in office. Also, considering the tenure of an internal auditor and an outside director which diminished from 3 years to 2 years by an Act on the Management of Public Institutions (applied to the executives appointed since April 2007), it seems most internal auditors resigned during the term of office but most outside directors resigned after the end of the term. Secondly, There was no evidence that the executives were changed during the term of office because of the bad performance of prior year. On the other hand, contrary to the normal expectation, the performance of prior year of the state-owned enterprise where an outside director resigned during the term of office was significantly higher than that of other state-owned enterprises. It means that the clauses in related laws on the executive dismissal on grounds of bad performance did not work normally. Instead it can be said that the executive change was made by non-economic reasons such as a political motivation. Thirdly, the results from a fixed effect model show there were evidences that performance turned negatively when CEOs or outside directors resigned during the term of office. CEO's resignation during the term of office gave a significantly negative effect on the margin of return on asset. Outside director's resignation during the term of office lowered significantly the margin of return on asset adjusted by industry. These results suggest that the executive's change in Korean state-owned enterprises was not made by objective or economic standards such as management performance assessment and the negative effect on performance of the enterprises was had by the unfaithful obeyance of the legal executive term.

  • PDF

A Study on the Types and Detail Structures of the Stylobate(補階) used in Royal Court Ceremonies of the Late Joseon Dynasty (조선후기 궁중의례에 사용된 보계(補階)의 유형과 세부 구조에 관한 연구)

  • Seok, Jin-Young;Han, Dong-Soo
    • Journal of architectural history
    • /
    • v.27 no.2
    • /
    • pp.89-100
    • /
    • 2018
  • The stylobate for expanding the external stage area was the most frequently installed installment out of the installments installed for royal court ceremonies. The stylobate was installed for various ceremonies such as funeral rites, ancestral rites, customary formalities, state examination, feasts for celebrating a honored guest of the court, queen's silkworm cultivating ceremony, heir appointment, the presentation of honorary titles for the king or queen in honor of their merits, and entertainment of foreign dignitaries. The exact period stylobates came to be used for the play stage. The stylobate consists of the 紅座板, 屯太木, 竹欄間, 足木, and the 層橋. Depending on the 足木, the substructure of the stylobate, the stylobate could be divided into the 長足木, 中足木, 短足木, 平足木 type. The detail structure of the stylobate changed in form from the jokmok and duntaemok that appeared until the time of King Seonjo, into the 長屯太木, 短屯太木, and the 短短屯太木 during the time of King Heonjong. With the introduction of the 中足木, materials began to become more segmented and the structure stronger. According to existing records, while the height of the stylobate was not significantly high prior to King Seonjo's reign, the 十四層雲橋 and the 十三層層橋 introduced during the time of Emperor Gojong was designed to reflect his rank in external ceremonies while the eight story step bridge was exhibited in internal ceremonies to reflect the rank of Queen Mother Sinjeong. From here, we can deduce that the fourteen and thirteen story cloud bridges representing the king was of a higher grade than the eight story step bridge which represented the queen mother. Finishing by adding boards to the lower part of the stylobates began to appear in the time of King Seonjo. During King Heonjong's reign, the lower finish became gentrified with a thin board called 修粧板, and yeomupan 廉隅板 for decorating the edges of the stylobates were installed. Such style of finishing the lower part of the stylobate with boards mostly appeared in elaborate feasts 進饌 and celebrations 進宴 within the royal court 內宴. The stylobates appeared to have served not only practical purposes such as expanding the stage area, but also as installments which realize the authority and prestige of the royal crown. They were installed according to the purpose of the ceremony and the rank of the participant. In short, stylobates became established during King Seonjo's reign, became segmented and gentrified during King Heonjong's reign, and began to take height variations during Emperor Gojong's reign to reflect the rank and authority of the king and queen mother. As such, it can be considered another characteristic of Joseon Dynasty architecture.

Childhood Tuberculosis Contact Investigation and Treatment of Latent Tuberculosis Infection: a Single Center Study, 2014-2017 (소아청소년 결핵 접촉자 검진 및 잠복결핵감염의 치료 현황: 2014-2017 단일 기관 연구)

  • Hwang, Woo Jin;Lee, Go Un;Kim, So Hyun;Cho, Eun Young
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.1
    • /
    • pp.32-41
    • /
    • 2019
  • Purpose: In order to prevent tuberculosis transmission early, it is important to diagnose and treat tuberculosis infection by investigating people who have contact with patients with active tuberculosis. Methods: From July 2014 to June 2017, the intrafamilial childhood contacts of the patients who were diagnosed with active tuberculosis at Chungnam National University Hospital were investigated for the presence of tuberculosis infection. We also retrospectively analyzed the treatment status of children treated with latent tuberculosis infection (LTBI) during the same period. Results: Among the 269 children who had intrafamilial contact with active tuberculosis patient, 20 (7.4%) did not receive any screening. At the first screening, one (0.4%) was diagnosed with pulmonary tuberculosis, seven (2.8%) had a previous history of tuberculosis infection, and 42 patients (16.9%) were diagnosed with LTBI. At the second screening, 29 patients (11.6%) were diagnosed with LTBI, and 61 patients did not finish the investigation. Only 188 (69.9%) out of 269 patients completed the investigation. Ninety patients received treatment for LTBI and 83 patients (92.2%) completed the treatment, of which 18 patients had side effects such as rash, fatigue, and gastrointestinal symptoms. However, there were no serious side effects requiring treatment discontinuation. Conclusions: The completion rate of childhood tuberculosis contact investigation was low, but the completion rate of LTBI treatment was high in children without serious side effects. In order to prevent and manage the spread of tuberculosis, active private-public partnership efforts and education of the patient and guardian are needed.

Histological Observation of Bone Reaction with Relation to Surface Treatment of Titanium (생체합금 Titanium의 표면처리에 따른 골반응의 변화에 대한 조직학적 관찰)

  • Ahn, Myun-Whan;Choi, Yong-Sug;Ahn, Jong-Chul;Seo, Jae-Sung;Lee, Dong-Chul;Jang, Jae-Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.116-133
    • /
    • 1996
  • The biocompatibility of the titanium has been estabilished through various experimental studies such as cell culture toxicity test, pyrogen test, mutagen test and others. In order to confirm biocompatibility after fabrication of titanium and to clarify the difference between the bone reaction after insertion of the lathed titanium rods and the bone reaction after insertion of the finished and polished rods, both rods were implanted into the proximal femur of a rabbit. Histologic reactions in the bone were observed according to the ASTM standards at the intervals of 6 weeks, 12 weeks and 26 weeks after implantation. The result were as follows : In 6 weeks after implantation of lathed titanium rods, inflammatory reactions, such as minimal degree infiltration of polymorphonuclear leukocytes and lymphocytes were observed in all cases. This was thought to he caused by surgical trauma. However, inflammatory cell infiltration was not seen after implantation of polished and finished rods in all cases. The cellular infiltration and the histologic reaction of the hone after implantation of lathed group were significantly more pronounced than those after implantation of the finished group. In 12 weeks after implantation of lathed rods, two of four cases revealed a minimal degree of cellular infiltration. No inflammatory cell infiltration was demonstrated after implantation of the finished group. The cellular infiltration and histologic reaction seemed to be more pronounced in the lathed group, but they were not significant statistically. At 26 weeks after implantation of the lathed and finished group, there was no cellular infiltration in both groups. New bone formation was observed up 26 weeks, and no difference between lathed titanium rods and finished titanium rods were apparent. Mild bone necrosis was observed in 1 case out of 11 cases in which lathed titanium rods were implanted. Bone necrosis was not observed in the finished titanium rod group. Fibrosis was observed in both groups, but differences were not significant between the experimental groups. In the lathed titanium rods group and the shorter interval group, inflammatory cell infiltration was significantly higher. Finished titanium rods and longer interval groups had markedly decreased tendences in histologic reaction ratings. As a conclusion, although certificated titanium might be safe to use, difference of biocompatibility were observed depending on the method of surface finish. By identifying biocompatibility as a long-term standardized animal study, we can develop progressed internal fixation device that is safe for human beings.

  • PDF