• Title/Summary/Keyword: Internal filling

Search Result 197, Processing Time 0.032 seconds

"Misery Collaterals" as Poor Angiographic Findings - Definition, Classification, and Practical Application -

  • Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.3
    • /
    • pp.159-163
    • /
    • 2006
  • Objective : Unique Internal carotid artery angiographic findings have been found especially in very poor grade aneurysmal subarachnoid hemorrhage[SAH] patients before and during the endovascular coiling. The author investigates their patterns and classifies them into lour subtypes. Methods : Among Hunt&Hess grade IV, V SAH patients, the author could gather eight patients who showed abnormal intracranial circulation in cerebral catheter-based angiography. Results : The author introduces new term 'misery collaterals' first and has classified them into four types with the case illustrations. Type 1 is the worst condition defined as almost no intracranial circulation. Type 2 is the condition of little intracranial circulation with contrast filling just only at vessels of brain base, type 3 is of no or little cortical circulation with contrast filling at bilateral large vessels of brain base through circle of Willis channel and type 4 is of visible bilateral cortical circulation but delayed intracranial circulation time. The prognosis of these eight patients showed misery collaterals were disappointed. Conclusion : These finding can be used as the supportive information in deciding a management plan in poor grade SAH patients.

A Study on the Characteristics of Condensation Heat Transfer of Two-Phase Loop Thermosyphons (루우프형 2상 유동 열사이폰의 응축열전달 특성에 관한 연구)

  • Park, Jong-Un;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.4
    • /
    • pp.894-901
    • /
    • 2014
  • This study concerns the performance of condensation heat transfer in two-phase loop thermosyphons. In the present work, R134a has been used as the working fluid. Liquid fill charge ratio defined by the ratio of working fluid volume to total internal volume of thermosyphon, heat flux and wind speed of condensation have been used as the experimental parameters. The results show that the filling rate of working fluid and heat flux are very important factors for the operation of two-phase loop thermosyphons. The optimum liquid fill charge ratio for the best condensation heat transfer rate was 80%.

Hydroforming Characteristics of Double Layered Tube (이중튜브의 액압 성형특성 연구)

  • Kwon, S.O.;Yi, H.K.;Chung, G.S.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.16 no.8
    • /
    • pp.567-574
    • /
    • 2007
  • Double layered tube is assembled with an inner tube and an outer tube, similar in material or not, contacting closely and deforming simultaneously when subjected to external force. For the manufacturing of double layered tube, the hydroforming assembly technology has several advantages. Therefore in this study, hydroforming characteristics of double layered tube was investigated. The free bulge test was performed to produce formability diagrams of double layered tubes at various forming pressure and feeding amounts. The hexagonal shape hydroforming test was also performed to estimate the dimensional accuracies of double layered tube through the corner filling ratio and the gap between inner and outer tube. Besides experimental analyses, the analytical model that can predict internal pressure for the hydroforming of double-layered tube was proposed and experimentally validated.

Derivation of design charts based on the two-dimensional structural analysis of geotextile tubes

  • Kim, Hyeong-Joo;Won, Myoung-Soo;Park, Tae-Woong;Choi, Min-Jun;Jamin, Jay C.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.2
    • /
    • pp.349-364
    • /
    • 2015
  • Analytical solutions for modeling geotextile tubes during the filling process and approximation method to determine the densified tube shape are reviewed. The geotextile tube filling analysis is based on Plaut & Suherman's two-dimensional solution for geotextile tubes having a weightless and frictionless inextensible membrane resting on a rigid horizontal foundation subjected to internal and external hydrostatic pressures. The approximation for the densified tube shape developed by Leshchinsky et al. was adopted. A modified method for approximating the densified tube shape based on an areal-strain deformation analysis is introduced. Design diagrams useful for approximating geotextile tube measurements in the design process are provided.

Mechanical Properties and Water Absorption of Rice Starch-Filled Linear Low Density Polyethylene

  • Wahab, Mohammad A.;Mottaleb, Mohammad A.
    • Macromolecular Research
    • /
    • v.9 no.6
    • /
    • pp.297-302
    • /
    • 2001
  • Rice starch was incorporated into linear low density polyethylene (LLDPE) using a Brabender Plastic-Corder internal mixer at a temperature of 140$\^{C}$ and 40 rpm. The starch loading was varied from 0 to 30% with 5 intervals. Studies on brabender torque development, mechanical properties and water absorption were investigated. The starch loading did not influence the brabender torque significantly. With respect to mechanical properties; the tensile strength and elongation at break decrease with increasing starch loading. The Young's modulus also increases with the starch filling. Mechanical properties were deteriorated as the starch absorbed moisture. The rate of water absorption was dependent on the starch filling in the composites. The scanning electron microscope (SEM) analysis was performed for the tensile fracture surfaces and it revealed the starch agglomeration and a poor dispersion of starch in the LLDPE matrix.

  • PDF

Selection and Conservation for the Filler of Three-storied Stone Pagoda at the West of Gameunsaji Site in Gyeongju (경주 감은사지서삼층석탑 충전제 선정과 보존처리)

  • Lee, Tae-Jong;Kim, Sa-Dug;Gal, Seo-Yeon
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.361-370
    • /
    • 2010
  • The open pore of stone cultural heritage is not expected to have an effect only by consolidation, and it has a drawback that only the internal wall adheres and gets consolidated due to the incrase of liquidity caused by the low viscosity and difference of materials in the case of filling with high molecules synthetic resins. Therefore, this research selected the effective filler for Three-storied Stone Pagoda at the West of Gameunsaji Site through the verification of filling effects of materials using the information about various fillers based on minerals. As the result of filler experiment, got filled with the combination of KSE 500 STE + KSE Filler A${\cdot}$KSE Filler B that is the same as the Member or has very similar properties. The total surface area of the west stone is $252.6m^2$ and the area where the internal opening has been developed is $17.77m^2$(7.03%) requiring a task that fills the internal($24,885m{\ell}$).

Development of a new injection mold structure for internal gears (새로운 내측기어 성형용 사출성형 금형구조의 개발)

  • Kwon, Youn Suk;Je, Deok Keun;Jeong, Yeong Deug
    • Design & Manufacturing
    • /
    • v.8 no.1
    • /
    • pp.40-44
    • /
    • 2014
  • As a rotating machine element, plastic gears are more and more widely used in such as industrial machine element, since plastic gear is lighter, higher wear-resistance, and higher vibration absorbing ability than metal gears. When operating plastic parts, tooth breakage and fatigue life shortened due to increasing number of applying load and tooth flank temperature rising, such that accuracy of plastic gears is divided from allowable range to cause vibration and noise. On this study, a internal plastic gears are developed which improved the filling balance molding process by a new injection mold structure. The new mold structure called HR3P(hot runner type 3plate mold). As the result from this studies, we obtained a very accurate roundness internal gears by using design of experiment.

  • PDF

Development of the injection mold structure for internal gears (내측기어 성형용 사출성형 금형구조의 개발)

  • Kwon, Y.S.;Jeong, Y.D.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.78-82
    • /
    • 2008
  • Plastic gears are more and more widely used in many industrial machine elements. Plastic gear has higher properties such as light weight, wear resistance, and vibration absorbing ability than metallic gears. But, in case of using an inaccurate plastic gear, its tooth breakage happen and fatigue life is shortened due to increase of applying load and temperature rising on the tooth flank. Inaccuracy of plastic gears such as pitch circle roundness and tooth profile generates vibration and noise. In this study, an internal plastic gears which is molded by a new injection mold structure are developed. The new mold structure is called the HR3P(hot runner type 3plate mold) that has an improved runner system in order to have good filling balance. As a result from this study, an internal gear with very accurate roundness was developed by using design of experiment.

  • PDF

Development of a new injection mold structure for internal gears (새로운 내측기어 성형용 사출성형 금형구조의 개발)

  • Kwon, Youn-Suk;Je, Deok-Keun;Jeong, Yeong-Deug
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.129-133
    • /
    • 2008
  • As a rotating machine element, plastic gears are more and more widely used in such as industrial machine element, since plastic gear is lighter, higher wear-resistance, and higher vibration absorbing ability than metal gears. When operating plastic parts, tooth breakage and fatigue life shortened due to increasing number of applying load and tooth flank temperature rising, such that accuracy of plastic gears is divided from allowable range to cause vibration and noise. On this study, a internal plastic gears are developed which improved the filling balance molding process by a new injection mold structure. The new mold structure called HR3P(hot runner type 3plate mold). As the result from this studies, we obtained a very accurate roundness internal gears by using design of experiment.

  • PDF

THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION (응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF