• Title/Summary/Keyword: Internal filling

Search Result 197, Processing Time 0.023 seconds

A micro-computed tomography evaluation of voids using calcium silicate-based materials in teeth with simulated internal root resorption

  • Tek, Vildan;Turker, Sevinc Aktemur
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.1
    • /
    • pp.5.1-5.8
    • /
    • 2020
  • Objectives: The obturation quality of MTA, Biodentine, Total Fill BC root canal sealer (RCS), and warm gutta-percha (WGP) in teeth with simulated internal root resorption (IRR) was evaluated by using micro-computed tomography. Materials and Methods: Standardized IRR cavities were created using 40 extracted maxillary central incisor teeth and randomly assigned into 4 groups (n = 10). IRR cavities were filled with MTA, Biodentine, Total Fill BC RCS (bulk-fill form) and WGP + Total Fill BC RCS. Percentage of voids between resorptive cavity walls and obturation material (external void), and inside the filling materials (internal voids) were measured. Results: Total Fill BC sealer in the bulk-fill form presented significantly highest values of external and internal void percentages (p < 0.05). Biodentine showed a significantly lowest external void percentage (p < 0.05). WGP + Total Fill BC RCS presented significantly lower values of internal void percentages than all groups (p < 0.05), except Biodentine (p > 0.05). Conclusion: None of the filling materials were created void-free obturation in resorption cavities. Biodentine may favor its application in teeth with IRR over Angelus MTA and bulkfill form of Total Fill BC.

FINITE ELEMENT ANALYSIS OF STRESS TRANSMITTED TO THE PULPOTOMIZED PRIMARY MOLARS TREATED BY VARIOUS TEMPORARY FILLING LOADED AT DIFFERENT CONDITION (하악 제2유구치 치수 절단술시 치아 및 충전재에 미치는 응력에 관한 유한 요소법적 분석)

  • Kim, Dong-Su;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.818-839
    • /
    • 1996
  • The strain gage, holographic and photoelastic analysis etc. have been used for stress analysis of prosthesis, orthodontic or orthopedic appliances and filling materials. But these methods has some limitation in analyzing the internal stress. The Finite Element Analysis has been proved to compensate this defect and widely used in this area. The purpose of this study was to compare the stress distributions of the various temporary filling methods being used in pulpotomy procedure. Three different models were designed according to temporary filling material and method: amalgam filling with ZOE base(Model I), amalgam filling with ZPC sub-base and ZOE(Model II), IRM filling only(Model III). The results of the experiment were as follows: 1. In model I under the load case 6 and 1, the significant stress was shown to be concentrated on the buccal portion of crown. 2. Model II showed the similar pattern of stress distribution to Model I. 3. In model III under load case 2, the stress was mainly distributed on the buccal cusp tip and buccal margin of filling material. In same model under the load case 3, the stress was distributed on the lingual cusp tip. 4. Based on the above data, IRM can be assumed to have advantage over the other tested materials in reducing the incidence of crown fracture by localized the stress within the filling materials.

  • PDF

A Case of Pulmonary Artery Sarcoma Presented as Cavitary Pulmonary Lesions

  • Min, Daniel;Lee, Ji-Hyun;Jeong, Hye-Cheol;Kim, Jung-Hyun;Shin, Suk-Pyo;Kim, Hong-Min;Han, Kyu Hyun;Jeong, Hye Yun;Kim, Eun-Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.3
    • /
    • pp.136-140
    • /
    • 2014
  • Pulmonary artery sarcoma (PAS) is a rare, poorly differentiated malignancy arising from the intimal layer of the pulmonary artery. Contrast-enhanced chest computed tomography (CT) is a good diagnostic modality that shows a low-attenuation filling defect of the pulmonary artery in PAS patients. An 18-year-old man was referred to our hospital for the evaluation and management of cavitary pulmonary lesions that did not respond to treatment. A contrast-enhanced CT of the chest was performed, which showed a filling defect within the right interlobar pulmonary artery. The patient underwent a curative right pneumonectomy after confirmation of PAS. Although lung parenchymal lesions of PAS are generally nonspecific, it can be presented as cavities indicate pulmonary infarcts. Clinicians must consider the possibility of PAS as well as pulmonary thromboembolism in patients with pulmonary infarcts. So, we report the case with PAS that was diagnosed during the evaluation of cavitary pulmonary lesions and reviewed the literatures.

Evaluation of Various Cardiae Indices and ROC Analysis in Coronary Artery Disease Employing Resting ECG Gated Blood Pool Scan (관상동맥질환에서 휴식기 심전도게이트혈액풀스캔을 이용한 각종 심기능 지표들의 평가 및 ROC 분석)

  • Choi, Chang-Woon;Lee, Dong-Soo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.40-48
    • /
    • 1992
  • Gated blood pool scan is frequently used for evaluating the change in cardiac function in various cardiac diseases. But resting gated blood pool scan using only LVEF as a cardiac index has been consitently shown to have a low sensitivity, which is about 50%, in detecting coronary artery disease. So it is recommended to compare exercise gated blood pool scan to resting gated blood pool scan. Exercise tests, however, are not always possible, especially in patients with musculoskeletal diseases, recent myocardial infarction and in elderly persons. We studied the usefulness of resting gated blood pool scan using multiple indices in evaluating the patients with coronary artery disease. Studied cases were 185 patients with coronary artery disease (angina pectoris 31, myocardial infarction 154) and 25 normals with low likelihood of coronary artery disease. We used $^{99m}Tc-labeled$ RBC, 740 MBq labeled by in vivo method. The data were evaluated by Micro DELTA computer program. The results were as following: 1) The ejection rates (PER, AER) and filling rates (PFR, AFR) were different in normls and patients with angina pectoris or myocardial infarction. 2) Mean phase angle, ejection rates and filling rates could separate normals from coronary artery disease patients with normal LVEF. 3) Regional ejection fraction was decreased at the site of the infarct in patients with myocardial infarction. 4) Peak filling rate was the the most detectable index in evaluation of cardiac function in patients with coronary artery disease. 5) The threshold at 1.5 standard deviation of normal range was considered as the most reliable cut-off value from ROC analysis. These data suggest that the resting gated blood pool scan has an important role in the evaluation of cardiac functional changes using various cardiac indices in patients with coronary artery disease.

  • PDF

Comparison of the Internal Pressure Behavior of Liquid Hydrogen Fuel Tanks Depending on the Liquid Hydrogen Filling Ratio (액체수소 충전 비율에 따른 액체수소 연료탱크의 내부 압력 거동 비교)

  • Dongkuk Choi;Sooyong Lee
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.3
    • /
    • pp.8-16
    • /
    • 2024
  • Because hydrogen has very low density, a different storage method is required to store the same amount of energy as fossil fuel. One way to increase the density of hydrogen is through liquefaction. However, since the liquefied temperature of hydrogen is extremely low at -252 ℃, it is easily vaporized by external heat input. When liquid hydrogen is vaporized, a self-pressurizing phenomenon occurs in which the pressure inside the hydrogen tank increases, so when designing the tank, this rising pressure must be carefully predicted. Therefore, in this paper, the internal pressure of a cryogenic liquid fuel tank was predicted according to the liquid hydrogen filling ratio. A one-dimensional thermodynamic model was applied to predict the pressure rise inside the tank. The thermodynamic model considered heat transfer, vaporization of liquid hydrogen, and fuel discharging. Finally, it was confirmed that there was a significant difference in pressure behavior and maximum rise pressure depending on the filling ratio of liquid hydrogen in the fuel tank.

Guideline for Filling Performance of Concrete for Modular LNG Storage Tanks (모듈형 LNG 저장탱크용 콘크리트 충전성능 가이드라인 제시)

  • Lee, Dong Kyu;Lee, Keon Woo;Park, Gi Joon;Kim, Sung Wook;Park, Jung Jun;Kim, Young Jin;Choi, Myoung Sung
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.86-93
    • /
    • 2018
  • Recently, the use of composite steel plate concrete structural modules filled with concrete between steel plates of complex internal structure, in which a large amount of studs are installed, is increasing in order to reduce the weight and to increase workability of structures such as LNG storage tanks. However, in Korea, there is no systematic criterion for evaluating the construction performance of composite steel plate concrete structural modules. Therefore, in this study, we propose a filling guideline of concrete for composite steel plate structural module. For this purpose, high filling performance concrete with general strength range was formulated and tested for filling ability and permeability for each formulation. Rheology analysis was performed to quantitatively evaluate the flow characteristics of concrete. The reliability of $T_{500}$ and plastic viscosity was evaluated to reflect the results of each test, and a guideline for high filling concrete satisfying the reliability of 0.9 or more was derived by reflecting the results of the study on the relationship between the $T_{500}$ and plastic viscosity. Through final fill-box test, filling performance was verified and guidelines were suggested.

A study on Characteristics of Molten Metal Flow in Vacuum DieCasting by Numerical Analysis (수치해석에 의한 진공다이캐스팅에서의 용탕 유동특성 연구)

  • Park, Jin-Young;Lim, Kwan-Woo;Lee, Kwang-Hak;Kim, Sung-Bin;Kim, Eok-Soo;Park, Ik-Min
    • Journal of Korea Foundry Society
    • /
    • v.27 no.4
    • /
    • pp.153-158
    • /
    • 2007
  • Molten metal flow in vacuum die casting was characterized by a numerical analysis. The VOF method was used to simulate the filling behaviors of molten metal during filling process. The various vacuum degrees of no vacuum(760 mmHg), 650, 500, 250 and 60mmHg were artificially applied in cavity. And the filling behaviors of molten metal with the applied vacuum conditions were simulated and compared with those of experiment. The results showed that molten metal was partially filled into cavity when vacuum was applied and the filling length of molten metal in cavity was increased with increasing applied reduced pressure in cavity. Also, the simulated filling behaviors of molten metal were apparently similar to those of experiment, indicating the numerical analysis developed in this study was highly effective. Through the result of fluid flow simulation, both relation equations of filling length and filling velocity with the variation of pressure conditions in cavity were calculated respectively and the internal gas contents of casting was significantly reduced by the modification of vacuum gate system.

Experimental Study on the Performance of an Electric Component Liquid Cooling System with Variation of the Waterblock Internal Shape (워터블록 내부형상에 따른 수냉식 전자부품 냉각장치 성능변화에 관한 실험적 연구)

  • Hahm, Hyung Chang;Park, Chang Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.331-337
    • /
    • 2013
  • An experimental study on the performance of a liquid electric component cooling system was performed. The thermal resistance and pressure drop at a heat sink were measured, for aluminum waterblocks with four different internal shapes, with either smooth surface, porous media filling, or with fins of 5 mm height, or of 7 mm height. The fins had 0.5 mm thickness, and the gap between the fins was 0.5 mm. The waterblock internal dimension was $36.5{\times}36.5{\times}7mm$. Compared with the waterblock with smooth surface, the thermal resistance reduction was 11%, 46%, and 42% for waterblocks with porous media filling, 5 mm, and 7 mm fins, respectively. A new dimensionless parameter was suggested to evaluate the waterblock performance, with the simultaneous consideration of thermal resistance and pressure drop. The performance of the waterblock with fins of 5 mm height was best by parameter.

Analysis of Left Ventricular Functional Parameters in Normal Korean Subjects by ECG Gated Blood Pool Scan (정상 한국인에서 게이트혈액풀스캔을 이용한 좌심실 심기능지표들의 분석)

  • Kang, Jae-Hwang;Park, Une-Sook;Kang, Byeong-Sun;Lim, Hyeon-Ok;Choi, Dong-Soo;Suh, Bong-Kwan;Chung, Soon-Il;Lee, Keun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.52-61
    • /
    • 1994
  • Background : The demand for refinement in noninvasive and quantitative assessment of left ventricular (LV) function is increasing. Purpose : To assess normal values of left ventricular functional parameters during both systole and diastole by scintigraphic method using computerized triple-head gamma camera and to evaluate correlations between these parameters. Methods : ECG gated blood pool scan with $^{99m}Tc$-Human serum albumin was performed in 94 normal Korean subjects. Ejection fraction (EF), systolic parameters [peak emptying rate (PER), average emptying rate (AER), time to peak emptying rate (TPER)], and diastolic parameters [peak filling rate (PFR), average filling rate (AFR), time to peak filling rate (TPFR)] were obtained by analysis of LV time-activity curve, the correlation of these parameters to the age and sex, and the correlation between these parameters were evaluated. Results : 1) Mean value of ejection fraction in study subjects was $59.6{\pm}5.25%$ and showed no significant correlation to age (r=-0.08) and sex but showed most pronounced correlation to PFR (r=0.46, p<0.001), PER (r=0.41, p<0.001), AFR (r=0.34, p<0.001) and AER (r=0.28, p<0.01). 2) Mean values of systolic parameters were as follows: $PER=3.22{\pm}0.50$ end-diastolic volume/sec, $AER=2.22{\pm}0.45$ end-diastolic volume/sec, $TPER=103.5{\pm}29.30$ msec. They showed no significant correlation to age and sex. 3) Mean values of diastolic parameters were as follows: $PFR=2.71{\pm}0.51$ end-diastolic volume/sec, $AFR=1.83{\pm}0.44$ end-diastolic volume/sec, $TPFR=132.1{\pm}33.45$ msec. They showed strong correlation to age (r=0.70, -0.64, 0.37, p<0.001). Conclusions : Left ventricular functional parameters in normal Korean subjects were obtained reliably by computerized scintigraphic method and may be applied to the evaluation of cardiac function in diseased patients.

  • PDF

A Case Study on Deformation Characteristics of Concrete Face Rockfill Dam (콘크리트 표면차수벽형 석괴댐(CFRD)의 거동해석)

  • Kim, Hun;Chung, Kyu-Jung;Lee, Wang-Gon;Jang, Jung-Ryeol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.111-116
    • /
    • 2003
  • Instrumentation system in Concrete Face Rockfill Dam(CFRD) can give special attention to the deformation characteristics of the rockfill and behavior of the concrete membrane during construction, reservoir filling and subsequent phase of operation. It also contains data about vertical and transversal compressibility moduli of the rockfill, deflections in the concrete slab, and draws comparisons with other concrete face rockfill dams of recent construction. In this paper, the internal deformation data from D dam monitored by means of hydrostatic settlements cells are analyzed. Observations cover the construction stage, reservoir filling and up to March 1991. The above method can be concluded D dam was well constructed and maintained.

  • PDF