• Title/Summary/Keyword: Internal energy response table

Search Result 4, Processing Time 0.029 seconds

A Basic Study of the European Side Impact Characteristics of Electric Vehicle(II) (전기자동차의 유럽 측면 충돌 특성 기초 연구(II))

  • 조용범;신효철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.143-152
    • /
    • 2002
  • European side impact analysis of an electric vehicle was done using the robust design method. In order to minimize VC as well as rib deflection, the injury response table which consists of rib deflection and VC response table has been introduced. The sensitivities and interactions are almost the same when it was compared with those of rib deflection and VC response table. Using internal energy of the factors, the starting time of dummy rib deflection and the contact average velocity, the internal energy and time-velocity response table were introduced. It is shown that the results of the new response tables have the similar characteristics to those of the Injury response table. It is suggested that the internal energy and time-velocity response table should be utilized to minimize injuries.

Shaking table test and horizontal torsional vibration response analysis of column-supported vertical silo group silo structure

  • Li, Xuesen;Ding, Yonggang;Xu, Qikeng
    • Advances in concrete construction
    • /
    • v.12 no.5
    • /
    • pp.377-389
    • /
    • 2021
  • Reinforced concrete vertical silos are universal structures that store large amounts of granular materials. Due to the asymmetric structure, heavy load, uneven storage material distribution, and the difference between the storage volume and the storage material bulk density, the corresponding earthquake is very complicated. Some scholars have proposed the calculation method of horizontal forces on reinforced concrete vertical silos under the action of earthquakes. Without considering the effect of torsional effect, this article aims to reveal the expansion factor of the silo group considering the torsional effect through experiments. Through two-way seismic simulation shaking table tests on reinforced concrete column-supported group silo structures, the basic dynamic characteristics of the structure under earthquake are obtained. Taking into account the torsional response, the structure has three types of storage: empty, half and full. A comprehensive analysis of the internal force conditions under the material conditions shows that: the different positions of the group bin model are different, the side bin displacement produces a displacement difference, and a torsional effect occurs; as the mass of the material increases, the structure's natural vibration frequency decreases and the damping ratio Increase; it shows that the storage material plays a role in reducing energy consumption of the model structure, and the contribution value is related to the stiffness difference in different directions of the model itself, providing data reference for other researchers; analyzing and calculating the model stiffness and calculating the internal force of the earthquake. As the horizontal side shift increases in the later period, the torsional effect of the group silo increases, and the shear force at the bottom of the column increases. It is recommended to consider the effect of the torsional effect, and the increase factor of the torsional effect is about 1.15. It can provide a reference for the structural safety design of column-supported silos.

A Basic Study of the European Offset Characteristics of Electric Vehicle (전기자동차의 유럽 OFFSET 충돌 특성 기초 연구)

  • 조용범;신효철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.111-122
    • /
    • 2002
  • European offset impact analysis of an electric vehicle was done using the robust design method. Section properties of some of the vehicle structure components which influence the european offset impact characteristics were chosen as the main factors fur the design. Eight factors were considered for the analysis: one with two level and seven with three level combinations comprising the L$\_$18/(2$^1$$\times$3$\^$7/) orthogonal array. It is shown that the sensitivities of the factors and the best combination of the factors can be obtained. One of the noteworthy results is that the design with the lower stiffness of the front components of engine room than the rear components can absorb more crash energy. Also it is shown that there exist interactions between some of factors considered.

Seismic Performance Evaluation of Seismic Isolation Device with Double Slip Friction Surface (이중 슬립마찰면을 이용한 면진장치의 면진성능평가)

  • Son, Su-Won;Kwon, Jeong-Ho;Kim, Jung-Gon;Jung, Yong-Gyu;Hwang, Eun-Dong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.712-722
    • /
    • 2020
  • Purpose: The damage from earthquakes with a magnitude of 5.0 or greater Korea has increased in South Korea. When a earthquake occurs, internal facilities and electric equipment besides urban structures will be damaged. Thus, in this paper, an earthquake-induced seismic isolation device with double slip fiction surfaces which can reduce the damage of electric power equipment such as distribution panel and then the seismic performance was evaluated. Method: To evaluate the seismic performance shaking table test was performed, a seismic performance comparison was performed according to the presence or absence of a seismic isolation device. The attenuation effect of the seismic isolation device are analyzed by comparing response acceleration and displacement for different frequencies and acceleration levels. Result: As a result of the test, the acceleration amplification was up to 42% less than when the seismic isolation device was installed in comparison to the other case without the seismic device. This is believed that the amplification energy has reduced because the displacement between the double slip friction surfaces of the seismic device play a role in dissipating the seismic energy. Conclusion: The seismic device with double slip friction surfaces has a greater earthquake attenuation effect in strong earthquakes than in weak ones, so the greater the frequency, the better the earthquake attenuation effect. Therefore, it is judged that earthquake energy can be decreased by applying to electric equipment such as distribution panels.