• 제목/요약/키워드: Internal dose measurement

검색결과 56건 처리시간 0.032초

Verification of Harmonization of Dose Assessment Results According to Internal Exposure Scenarios

  • Kim, Bong-Gi;Ha, Wi-Ho;Kwon, Tae-Eun;Lee, Jun-Ho;Jung, Kyu-Hwan
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.143-153
    • /
    • 2018
  • Background: The determination of the amount of radionuclides and internal dose for the worker who may have intake of radionuclides results in a variation due to uncertainty of measurement data and ingestion information. As a result of this, it is possible that for the same internal exposure scenario assessors could make considerably different estimation of internal dose. In order to reduce this difference, internal exposure scenarios for nuclear facilities were developed, and intercomparison were made to determine the harmonization of dose assessment results among the assessors. Materials and Methods: Seven cases on internal exposures incidents that have occurred or may occur were prepared by referring to the intercomparison excercise scenario that NRC and IAEA have carried out. Based on this, 16 nuclear facilities concerned with internal exposure in Korea were asked to evaluate the scenarios. Each result was statistically determined according to the harmonization discrimination criteria developed by IDEAS/IAEA. Results and Discussion: The results were evaluated as having no outliers in all 7 cases. However, the distribution of the results was spread by various causes. They can be divided into two wide categories. The first one is the distribution of the results according to the assumption of the intake factors and the evaluation factors. The second one is distribution due to misapplication of calculation method and factors related to internal exposure. Conclusion: In order to satisfy the harmonization criteria and accuracy of the internal exposure dose evaluation, it is necessary that exact guidelines should be set on low dose, and various intercomparison cases also be needed including high dose exposure as well as the specialized education. The aim of the blind test is to make harmonization evaluation, but it will also contribute to securing the expertise and high quality of dose evaluation data through the discussion among the participants.

≪상한론≫ 탕제(湯劑)에서 반하(半夏)의 일일 복용량 수정 (Revisoin of the Daily Dose of Pinelliae Tuber in Treatise on Cold Damage Diseases)

  • 김인락
    • 대한본초학회지
    • /
    • 제35권1호
    • /
    • pp.19-25
    • /
    • 2020
  • Objects : The daily dose of Pinelliae Tuber in ≪Treatise on Cold Damage Diseases≫ is half seung in volume, two and half ryang in weight, and fifteen in total number. But the daily dose should be a whole number. So I found out the background of this setting and correct solution. Methods : I searched Classics of Traditional Medicine, found out the background of the daily dose setting, solution. Results : The daily dose of Pinelliae tuber in ≪Hangdi's Internal Classic Miraculous Pivot≫, ≪Bohenggyuljangbuyongyakbeobyo≫ is half seung. ≪Treatise on Cold Dameage Diseases≫ followed the same daily dose of that because it referred to these books. In ≪Synopsis of Prescription of the Golden Chamber≫, the daily dose of that is half seung, one or two seung. The half seung of the Pinelliae Tuber is thirty three mL, but the diameter is 1~1.5 cm that accurate measurement by volume is difficult. The daily dose by weight is correct considering the unity of marking of the daily dose, accuracy of measurement, the fact that Pinelliae Tuber is currently distributed by cutting. So, two ryang is correct which is thirteen gram. Conclusions : Considering the traditionality, the convenience of measurement, the daily dose of Pinelliae Tuber in the ≪Treatise on Cold Damage Diseases≫ is half seung, but considering the unity, accuracy, current state of distribution, it is correct that the daily dose of it is two ryang. It corresponds to thirteen gram.

몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석 (The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation)

  • 정주영;윤도군;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.253-258
    • /
    • 2013
  • 본 연구의 목적은 electronic portal imaging device (EPID)를 통하여 방사선 치료를 받는 환자로부터 투과해 나오는 선량으로 외부적인 선량 재구성과 몬테카를로 전산모사로부터 도출되는 내부 선량 계측과의 관계를 도출하고 이를 분석하기 위한 연구로 진행되었다. 본 연구는 전산모사 연구로써 두 가지의 경우를 비교 분석하고 이와 비슷한 연구에 대한 기본적인 지표를 제공하고자 시행되었다. 실험에 관한 기하학적 정보와 방사선 소스에 대한 정보를 몬테카를로 전산모사 툴인 Monte Carlo n-particle (MCNPX)에 입력하였고 EPID 이미지 도출을 위하여 MCNPX 내에 tally카드를 이용하여 선량정보를 도출하고 이를 영상화 할 수 있도록 하였다. 또한 내부적인 계측을 위하여 물 팬텀을 소스와 표면의 거리(source to surface distance, SSD)가 100 cm이 되도록 설정하였으며, 그보다 10 cm 아래에 EPID를 위치시켰다. 내부 계측은 물팬텀 자체에서 흡수되는 흡수 선량을 mesh tally로 수집하였고, 4문 조사를 통하여 중첩된 선량에 대한 데이터를 획득하였다. 그와 동시에 EPID에서 물을 투과해 나오는 선량을 획득 한 뒤 역 투사 방법을 사용하여 선량 재구성을 하였다. 이둘의 경우를 비교하기 위해 자체적인 교정(calibration)을 통하여 투과해 나온 선량과 흡수된 선량과의 관계를 비교하고 4문 조사를 통하여 물 팬텀 내의 특정 부분에 대한 중첩된 선량 데이터와 EPID를 통해 재구성한 선량 데이터를 분석하였다. 물 팬텀과 EPID에서 획득한 누적 선량의 합은 각각 평균 3.4580 MeV/g과 3.4354 MeV/g이었다. 이는 앞서 계측된 물 팬텀 내부의 누적 선량과 0.6536% 선량 오차를 보였다.

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.

갑상선 내부피폭선량 측정치 보정을 위한 몬테카를로 모의실험 코드 (CALEFF) 개발 및 검출효율 계산 (Development of a Monte Carlo Simulation Code (CALEFF) for Calibrating Thyroid Internal Dose Measurement and Detection Efficiency Calculation)

  • 안기수;조효성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권2호
    • /
    • pp.117-122
    • /
    • 2005
  • 1999년 개정된 국내 원자력법 시행령 제2조 5항에 의하면 2003년부터 원전 작업종사자들에 대해 외부 피폭 선량뿐만 아니라 내부피폭 선량도 합산하여 평가하도록 하였으며 또한 각 선량평가에 대한 오차도 50% 이내로 유지되어야 한다고 규정한 바 있어 전신이나 갑상선 계측기와 같은 내부피폭선량 측정 장비의 정밀한 계측이 요구되고 있다. 이러한 국내 원자력법의 개정에 부합하여 본 연구에서는 내부피폭 선량측정 결과치의 정확도를 향상시키기 위해서 현재 개발 중인 갑상선 내부피폭선량 측정 시스템의 검출효율을 계산하기 위한 몬테카를로 모의실험 코드(CALEFF)를 개발하였으며, 이 코드를 사용하여 다양한 실험조건에서 검출효율을 계산하였다. 향후 갑상선 내부피폭선량 측정 시스템의 보정인자로 사용하고자 한다.

  • PDF

호흡에 의한 내부 움직임의 영향이 있는 간에서의 실험적 선량 측정 (Dose perturbation measurements during the liver treatment with internal organ motion: Mathematical modeling and Experimental simulation)

  • 정진범;김연래;정원균;서태석
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.115-118
    • /
    • 2004
  • 우리의 연구는 호흡에 의해 움직임의 영향을 받는 장기 및 종양에 대해서 조사된 선량분포를 측정하는 것이다. 이 연구를 수행하기 위해, 사전연구로 이전에 발표된 논문을 토대로 호흡에 의해 장기 및 종양의 움직임 변위를 조사하였다. 그리고 조사된 데이터를 활용하여 호흡에 따른 움직임을 구동 시스템을 적용하여 구현하였다. 내부 움직임에 의한 선량분포의 변화를 측정하기 위해서 이 구동 팬톰 시스템을 사용하였다. 이 결과로부터 호흡에 환자의 조사되는 선량분포의 부정확 정도를 평가할 수 있었다.

  • PDF

Dosimetric Analysis on the Effect of Target Motion in the Delivery of Conventional IMRT, RapidArc and Tomotherapy

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.164-170
    • /
    • 2017
  • One of the methods to consider the effect of respiratory motion of a tumor target in radiotherapy is to establish a treatment plan with the internal target volume (ITV) created based on an accurate analysis of the target motion displacement. When this method is applied to intensity modulated radiotherapy (IMRT), it is expected to yield a different treatment dose distribution under the motion condition according to the IMRT method. In this study, we prepared ITV-based IMRT plans with conventional IMRT using fixed gantry angle beams, RapidArc using volumetric modulated arc therapy, and tomotherapy using helical therapy. Then, the variation in dose distribution caused by the target motion was analyzed by the dose measurement in the actual motion condition. A delivery quality assurance plan was prepared for the established IMRT plan and the dose distribution in the actual motion condition was measured and analyzed using a two-dimensional diode detector placed on a moving phantom capable of simulating breathing movements. The dose measurement was performed considering only a uniform target shape and motion in the superior-inferior (SI) direction. In this condition, it was confirmed that the error of the dose distribution due to the target motion is minimum in tomotherapy. This is thought to be due to the characteristic of tomotherapy that treats the target sequentially by dividing it into several slices. When the target shape is uniform and the main target motion direction is SI, it is considered that tomotherapy for the ITV-based IMRT method has a characteristic which can reduce the dose difference compared with the plan dose under the target motion condition.

Technegas 스캐닝 후 중력환기에 의한 공간선량율 측정 (The Measurement of Spatial Dose Rate by Gravity Ventilation after Technegas Scanning)

  • 김성빈;원도연
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.667-674
    • /
    • 2019
  • Technegas를 사용한 검사는 단순 확산 누적을 통해 폐 영상을 이미지화하기 때문에 검사를 마친 후에 검사실이 오염될 수 있다. 따라서 방사선 작업 종사자와 검사를 기다리는 환자는 technegas 흡입으로 인한 내부 피폭의 영향을 받게 된다. 이에 중력환기 전후의 시간경과에 따른 공간선량율 분포를 비교, 분석함에 따라 방사선사, 의료진, 대기 환자의 피폭선량 저감화 방법을 모색하고자 한다. 중력환기 전후 환자의 호흡기 위치에서 거리별, 각도별로 공간선량율을 10분 동안 측정하고 평균값, 표준 편차 및 감소율을 계산하였다. 실험 결과, 중력 환기 전후 감소율은 최고 95.31%였고 가장 높은 감소율은 1 ~ 3분 사이에서 나타났다. 중력환기를 통해서 방사선 작업종사자, 대기환자, 환자 보호자 및 간호사의 피폭선량을 감소시킬 수 있다. 결론적으로 중력환기를 통한 피폭선량 감소 결과는 방호 최적화를 이루는 역할을 할 것이며 ICRP 103에서 권고한 의료 피폭 저감화에 부합된다.

전신계측기를 이용한 원전종사자 방사성오염 위치확인과 내부방사능 측정개선에 관한 연구 (A Study on the Verification and Improvement to Locate and Determine the Radioactive Contamination Using a Whole Body Counter)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.37-42
    • /
    • 2009
  • 국내 원전에서는 원전종사자의 내부피폭 방사능을 측정하기위해 전신계측기를 이용하고 있다. 이 전신계측기는 Sodium Iodide를 이용한 섬광검출기로서 짧은 시간에 종사자가 보유한 방사성핵종과 방사능을 측정하는 기능을 가지고 있다. 그런데 종사자의 신체표면에 부착된 오염과 내부에 침적된 오염을 구분하지 못하기 때문에 방사선계측 과정에서 종종 오류를 범할 가능성이 있으며, 이 경우 내부피폭선량은 매우 보수적으로 과대평가된다. 이러한 문제점을 개선하고자 종사자의 인체 내부와 외부 표면오염을 구분하고, 보다 체계적으로 오염부위를 확인할 수 있도록 전신계측기와 인체모형 팬텀을 이용한 방사능 계측실험을 수행하였다. 또한 원전에서 발생하는 주요 핵종의 신체내 침적위치를 고려하여 전신계측기의 최적 방사능 측정모드를 결정하는 실험을 수행하였다. 이러한 방사능 측정 실험결과를 근거로 원전종사자의 내부방사능 측정과 선량평가 절차를 개선하였다. 이에따라 보다 정확한 전신계측프로그램의 적용으로 내부피폭선량의 보수적 평가를 방지할 수 있을 것으로 기대된다.

한국성인 남성을 대상으로 한 방사성옥소의 갑상선 섭취율에 따른 각 장기별 흡수선량 평가 (Assessment of Absorbed Dose of by Organ according to Thyroidal Uptake of Radioactive Iodine for Adult Korean Males)

  • 김정훈;임창선;황주호
    • 한국의학물리학회지:의학물리
    • /
    • 제18권4호
    • /
    • pp.187-193
    • /
    • 2007
  • 한국인의 생리적 특성에 맞는 방사성핵종의 체내 흡수선량 평가를 위한 일환으로 한국 성인 남성 28명을 대상으로 $^{131}|$을 경구투여 후 갑상선섭취율 및 소변 일일배설률을 산정하고 각 장기별 흘수선량을 평가하였다 그 결과, 첫째, 투여 24시간 후 갑상선이 평균 19.70%의 섭취율과 71.12%의 소변 일일배설률을 나타냈다. 둘째 본 연구에서 산출한 갑상선섭취율과 기존 ICRP에서 제시하는 갑상선섭취율 30%에 따른 전신유효선량은 각각 1.464E-08 Sv, 2.189E-08 Sv로 약 1.5배의 차이를 나타났다. 정량적인 방사성 옥소의 흡수선량 평가를 위해서는 기존 ICRP에서 제시하는 자료에 의존하기 보다는 인종별 새로운 측정을 통해 각 핵종별 자료의 확보만이 체내피폭평가시 오류를 최소화 할 수 있다.

  • PDF