• Title/Summary/Keyword: Internal cooling

Search Result 437, Processing Time 0.024 seconds

Plan Study of Improvement on Thermal Flow at Computer Main Frame (컴퓨터 본체 구조의 열유동에 관한 개선 방안 검토)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • This study is to analyze the internal flow at the inside of computer case which is commonly used. The inner configuration are modelled and simulation analysis is done by ANSYS-CFX. Dead volume is happened according to the positioning of VGA and HDD. The advanced model is suggested by removing this volume and making the smooth cooling flow. This model is formed with the constraint conditions same as the existing model. As compared with the existing model, flow configuration is different and the average temperature becomes lower through flow analysis about the advanced model.

An Experimental Study on Comparing Solar Heat Shading Performances in Accordance with the Type of Internal Blinds in the Summer (하절기 내측 블라인드의 유형별 일사차폐성능 비교 실측연구)

  • Park, Eun-Mi;Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • The purpose of this study was to compare heat shading performance of various blind types in summer. 4 types of blinds were employed and the results are summarized as follows: 1) There were significant differences in indoor thermal environment and heat shading performance between different heat shading devices, and functional blinds demonstrated relatively superior heat shading performance. 2) Indoor long wave radiation influx measures were lowest for the coating roll blind (Blind B), followed by the coating venetian blind (Blind C), the venetian blind (Blind A), the roll blind, and not having any blinds at all. 3) Such examination results carry implications to reduce cooling load and enhance the indoor environment.

A Study of Noise Improvement of variable displascement swash plate type compressor with internal control valve (내부제어밸브를 가진 가변 사판식 압축기의 소음개선에 관한 연구)

  • Han, Gyu-Suk;Rho, Gyoung-Deok;Kong, Moon-Seong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.165-168
    • /
    • 2006
  • Due to the distinct advantages of comfort, drive ability and fuel economy standard, the variable displacement swash plate type compressor which can control the compressor displacement by increasing of reducing the swash plate angle has developed for automotive air-conditioning system. That can be obtained constant temperature of car room on the variation cooling capacities of engine speeds. In this paper we investigated the improvement of internally controlled variable displacement swash plate compressor on noise.

  • PDF

Experimental study of internal flow field about 90degree elbow for cooling seawater pipe at the main condenser (주복수기 냉각해수배관의 직각 엘보 내부유동특성에 관한 연구)

  • Oh, Seung Jin;Cho, Dae Hwan;Bong, Tae Geun;Kim, Ok Sok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.152-153
    • /
    • 2012
  • While engine room arranging pipe which is used from the vessel, It measured the internal flow of 90 degree elbow which is used from the main condenser. Fluid flow in elbow of 90 degree is measured by PIV and Dewetron system. The Reynolds number adopts 50000 and experimental study of flow field in the elbow.

  • PDF

Simulation Study on the Performance Improvement of a Transcritical Carbon Dioxide Cycle (초월임계 이산화탄소 사이클의 성능향상에 관한 시뮬레이션 연구)

  • 조홍현;김용찬;서국정
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.158-166
    • /
    • 2004
  • The performance of a heat pump using $CO_2$ is predicted and analyzed by using a cycle simulation model developed in this study. Cycle simulations are conducted by varying design parameters and operating conditions with the applications of advanced techniques to improve system performance. The applied systems in the simulations are internal heat exchanger, expander, and 2-stage compression with intercooling. As a result, the applications of advanced techniques improve the heating and cooling performances of the transcritical $CO_2$ cycle by 8∼26% and 20∼30%, respectively, over the basic cycle.

PRELAUNCH THERMAL ANALYSIS OF KSLV-I PAYLOAD FAIRING

  • Choi Sang-Ho;Kim Seong-Lyong;Kim Insun
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.356-359
    • /
    • 2004
  • Prelaunch thermal analysis of the KSLV (Korea Space Launch Vehicle)-I PLF (Payload Fairing) was performed to predict maximum/minimum liftoff temperatures and to evaluate of air conditioning performance. Prelaunch thermal analysis includes internal air conditioning effect, external convective heating/cooling, radiation exchange with the ground and sky, radiation between spacecraft and PLF, and solar radiation incident on PLF. Analysis was performed at two extreme conditions, hot day condition and cold day condition. The results showed that the maximum liftoff temperature was $53^{\circ}C$ and the minimum liftoff temperature was $-3.8^{\circ}C$. It was also found that conditioned air supplying, in $20{\pm}2^{\circ}C\;and\;1200\;m^3/hr$, is sufficient to keep the internal air in required temperature range.

  • PDF

Preparation and Properties of Functional Lubricant based Synthetic Polyolesters (합성 폴리올에스테르류 기능성 윤활유의 제조 및 특성)

  • Lee, Jae-Duck;Jeong, Noh-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.522-530
    • /
    • 2010
  • We developed functional synthetic lubricant for internal combustion engine oil, which would improve engine oil performance for internal combustion engine and extend engine life. We made base oil by synthesizing nonanoic acid, 1.1.1-trimethylol propane (which has good bio-degradability) and pentaerythrytol ester. We synthesized catalyst using p-toluene sulfonic acid 0.15 wt% and coloring-prevention agent hypo-phosphorus acid 0.18 wt% at 180-$190^{\circ}C$. Reaction temperature was increased at the rate of $10^{\circ}C$ for every 1 hour. When acid value reached below 3, reaction was completed. After cooling and deoxidization, we washed it by distilled water two times. After dehydration and filtering, we obtained trimethylol propane tripelargonate (TMTP) and pentaerythrytol tetrapelargonate (PETP) at yields of 96 % and 98 % respectively.

Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings (고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구)

  • Cho, Jin-Kyun;Jeong, Cha-Su;Kim, Byung-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

Reaction of $FeC_5H_5^+$ Ion with Neutral Ferrocene: The Dependence of Reaction Pathways on Its Internal Energy

  • 김병주;소훈영
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.10
    • /
    • pp.1181-1185
    • /
    • 1999
  • The reaction of FeC5H5+ ion with ferrocene molecule is investigated using FT-ICR mass spectrometry. FeC5H5+ ions are generated by dissociative ionization of ferrocenes using an electron beam. The reaction gives rise to the formation of the adduct ion, Fe2(C5H5)3+, in competition with charge transfer reaction leading to the formation of ferrocene molecular ion, Fe(C5H5)2+·. The branching ratio of the adduct ion increases as the internal energy of the reactant ion decreases and correspondingly the branching ratio for the charge transfer reaction product decreases. The observed rate of the addition reaction channel is slower than that of the charge transfer reaction. The observation of the stable adduct ions in the low-pressure ICR cell is attributed to the radiative cooling of the activated ion-molecule complex. The mechanism of the reaction is presented to account for the observed experimental results.

Development of Heat Exchanger for Cooling Bleed Air (Bleed Air 냉각용 열교환기 개발)

  • Yu, Kyoung-Won;Baek, Nak-Gon;Park, Bong-Kyo;Kim, Joon-Tae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.427-430
    • /
    • 2008
  • This study considered the heat exchanger of bleed air from engine. The computional fluid analysis was performed considering the external flow and internal flow on heat exchanger. Using the CFD results, the external configuration and internal flow path of heat exchanger were designed. And also the performance test is conducted and the results of tests were compared with the analysis resutls.

  • PDF