• Title/Summary/Keyword: Internal Waves

Search Result 282, Processing Time 0.027 seconds

Development of Smart Active Layer Sensor (I) : Theory and Concept Study (스마트 능동 레이어 센서 개발 (I): 이론 및 개념 연구)

  • Yoon, Dong-Jin;Lee, Young-Sup;Kwon, Jae-Hwa;Lee, Sang-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.465-475
    • /
    • 2004
  • This paper is the first part of the study on the development of a smart active layer (SAL) sensor, which consists of two parts. In this first part, the theory and concept of the SAL sensor is investigated, which is designed for the detection of elastic waves caused by internal cracks and damages in structures. For the development SAL sensor, (i) the basic theory of elastic waves was studied, (ii) the feasible study of the SAL as an elastic waves detection sensor using the finite element analysis (FEA) with respect to a piezoceramic disc was performed. (iii) the comparison of performances between some piezoceramic sensors and a commercial acoustic emission (AE) sensor was accomplished to ensure the applicability by the experimental means, such as a pencil lead break test. Also, the conceptional study for the SAL sensor, which can be utilized for the effective detection and locating of defects by the arrangement of regularly distributed sensors, was discussed.

A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables (동파방지열선 화재 흔적분석과 발화원인 연구)

  • Lee, Jung Il;Ha, Kag Cheon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.

Correlation of Reflection Coefficient and Extracted Efficiency of an Oscillating Water Column Device in Front of a Seawall (안벽 앞에 설치된 진동수주형 파력발전장치의 반사율과 추출효율과의 상관관계)

  • Cho, Il Hyoung;Kim, Jeongrok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.4
    • /
    • pp.242-251
    • /
    • 2020
  • In this study, the extraction efficiency and reflection coefficient by a two-dimensional OWC (Oscillating Water Column) WEC (wave energy converter) installed in front of a seawall was investigated for regular/irregular waves. The matched eigenfunction expansion method (MEEM) based on the linear potential theory was applied as an analytical tool. The diffraction problem by the incident wave in the open-chamber and the radiation problem by the oscillating pressure in the closed-chamber were solved to obtain the volume fluxes at the internal free-surface. Applying the volume fluxes into the continuity equation for the airflow in a chamber, we got the oscillating air pressure. The maximum extracted power and corresponding reflection coefficient were determined at the optimal turbine coefficient that maximizes the extracted power. OWC device designed for a high extracted efficiency simultaneously contributes to reduce reflected waves.

Antiarrhythmic Effect of Artemisinin in an Ex-vivo Model of Brugada Syndrome Induced by NS5806

  • Hyung Ki Jeong;Seo Na Hong;Namsik Yoon;Ki Hong Lee;Hyung Wook Park;Jeong Gwan Cho
    • Korean Circulation Journal
    • /
    • v.53 no.4
    • /
    • pp.239-250
    • /
    • 2023
  • Background and Objectives: Brugada syndrome (BrS) is an inherited arrhythmia syndrome that presents as sudden cardiac death (SCD) without structural heart disease. One of the mechanisms of SCD has been suggested to be related to the uneven dispersion of transient outward potassium current (Ito) channels between the epicardium and endocardium, thus inducing ventricular tachyarrhythmia. Artemisinin is widely used as an antimalarial drug. Its antiarrhythmic effect, which includes suppression of Ito channels, has been previously reported. We investigated the effect of artemisinin on the suppression of electrocardiographic manifestations in a canine experimental model of BrS. Methods: Transmural pseudo-electrocardiograms and epicardial/endocardial transmembrane action potentials (APs) were recorded from coronary-perfused canine right ventricular wedge preparations (n=8). To mimic the BrS phenotypes, acetylcholine (3 μM), calcium channel blocker verapamil (1 μM), and Ito agonist NS5806 (6-10 μM) were used. Artemisinin (100-150 μM) was then perfused to ameliorate the ventricular tachyarrhythmia in the BrS models. Results: The provocation agents induced prominent J waves in all the models on the pseudo-electrocardiograms. The epicardial AP dome was attenuated. Ventricular tachyarrhythmia was induced in six out of 8 preparations. Artemisinin suppressed ventricular tachyarrhythmia in all 6 of these preparations and recovered the AP dome of the right ventricular epicardium in all preparations (n=8). J wave areas and epicardial notch indexes were also significantly decreased after artemisinin perfusion. Conclusions: Our findings suggest that artemisinin has an antiarrhythmic effect on wedge preparation models of BrS. It might work by inhibition of potassium channels including Ito channels, subsequently suppressing ventricular tachycardia/ventricular fibrillation.

Numerical Computations on the Hydrodynamic Forces by Internal Waves in a Sediment Pocket (퇴적 침전구에서 발생하는 내면파 유동에 의한 유체력 해석)

  • Kyoung Jo-Hyun;Kim Jang-Whan;Bai Kwang-June
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.4
    • /
    • pp.192-198
    • /
    • 2004
  • A numerical method is developed to solve a two-dimensional diffraction problem for a body located in a sediment pocket where a heavier muddy water is trapped. In the present study, the wave exciting forces acting on a submerged body in the water-sediment interface by an incident wave is investigate. It is assumed that the heavier mud is trapped locally in a sediment pocket. A mathematical formulation is made in the scope of the potential theory. The fluid is assumed to be inviscid, incompressible and its motion irrotational. The boundary conditions on the unknown free surface and interface are linearized. As a method of solution, the localized finite-element method is adopted. In the method, the computation domain is reduced by utilizing the complete set of analytic solutions known in the infinite subdomain to be truncated by introduction of an appropriate juncture conditions. The main advantage of this method is that any complex geometry of the boundaries can be easily accommodated. Computations are carried out for mono-chromatic plane progressive surface waves normally incident on the domain. Numerical results are compared with those obtained by Lassiter based on Schwingers variational method. Good Agreements are obtained in general. Another numerical computations are made for the cases with and without a body in the sediment pocket.

  • PDF

Preliminary Study on the Development of a Performance Based Design Platform of Vertical Breakwater against Seismic Activity - Centering on the Weakened Shear Modulus of Soil as Shear Waves Go On (직립식 방파제 성능기반 내진 설계 Platform 개발을 위한 기초연구 - 전단파 횟수 누적에 따른 지반 강도 감소를 중심으로)

  • Choi, Jin Gyu;Cho, Yong Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.6
    • /
    • pp.306-318
    • /
    • 2018
  • In order to evaluate the seismic capacity of massive vertical type breakwaters which have intensively been deployed along the coast of South Korea over the last two decades, we carry out the preliminary numerical simulation against the PoHang, GyeongJu, Hachinohe 1, Hachinohe 2, Ofunato, and artificial seismic waves based on the measured time series of ground acceleration. Numerical result shows that significant sliding can be resulted in once non-negligible portion of seismic energy is shifted toward the longer period during its propagation process toward the ground surface in a form of shear wave. It is well known that during these propagation process, shear waves due to the seismic activity would be amplified, and non-negligible portion of seismic energy be shifted toward the longer period. Among these, the shift of seismic energy toward the longer period is induced by the viscosity and internal friction intrinsic in the soil. On the other hand, the amplification of shear waves can be attributed to the fact that the shear modulus is getting smaller toward the ground surface following the descending effective stress toward the ground surface. And the weakened intensity of soil as the number of attacking shear waves are accumulated can also contribute these phenomenon (Das, 1993). In this rationale, we constitute the numerical model using the model by Hardin and Drnevich (1972) for the weakened shear modulus as shear waves go on, and shear wave equation, in the numerical integration of which $Newmark-{\beta}$ method and Modified Newton-Raphson method are evoked to take nonlinear stress-strain relationship into account. It is shown that the numerical model proposed in this study could duplicate the well known features of seismic shear waves such as that a great deal of probability mass is shifted toward the larger amplitude and longer period when shear waves propagate toward the ground surface.

Study of Ryodoraku Parameters for Diagnosing Gastric Dysmotility in Functional Dyspepsia (기능성 소화불량증에서 위운동성 장애 진단을 위한 양도락 지표 연구)

  • Kim, So-Yeon;Yoon, Sang-Hyup;Kim, Yoon-Bum;Jung, Sung-Ki
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.2
    • /
    • pp.401-412
    • /
    • 2008
  • Objectives : The aim of this study was to investigate the characteristics of Ryodoraku and association of Ryodoraku with gastric dysmotility in functional dyspepsia(FD). Methods : Subjects were 154 patients with FD and 18 patients with asthma. We calculated the average Ryodoraku score(RS, ${\mu}A$) and each variation from physiologic range of 12 Ryodoraku points, and investigated the incidence when left and right points were simultaneously below(bilateral deficiency) or above(bilateral excess) physiologic range. Postprandial regularity of normal slow waves, power ratio, and postprandial % of bowel sound were obtained by electrogastrography and enterotachography, and were used as gastric dysmotility index. Results : 1. Bilateral excess of H4, H5, F1, and F4 and bilateral deficiency of H4, H5, and H6 were characteristic in FD compared with asthma patients. 2. Incidence of gastric dysmotility in bilateral deficiency of H4, H5, and H6 was 100%, and was higher than in total FD patients(88.3%). 3. There was a positive correlation between the variation of H6 and % postprandial bowel sound. 4. Deficient tendency of H4, H5, and H6 was more evident when RS was above $40{\mu}A$ in FD. Conclusions : These findings suggest that gastric dysmotility in FD can be diagnosed when a pattern of H4, H5, H6 bilateral deficiency and F1, F4 bilateral excess is shown at the same time. We think this phenomenon is related to low activity of the vagus nerve rather than meridian pathway with result based on positive correlation between variation of H6 and postprandial % of bowel sound.

  • PDF

Effect of Jichul-hwan on Gastric Motility in Conscious and Gastric Wall Injured Rats (지출환(枳朮丸)의 흰쥐 위(胃) 운동성(運動性)에서 정상 상태 및 위벽 국소손상 후에 대한 효능)

  • Lee, Seung-Woo;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.1
    • /
    • pp.189-199
    • /
    • 2008
  • Background & Objective : Jichul-hwan(JCH) has been used for the treatment of functional dyspepsia, regarded as a gastric dysmotility disease. We investigated the effects of JCH on gastric motility and its mechanisms of action in rats. Methods : The gastric wall was injured by tracting a part of stomach body in rats. Gastric emptying was measured after administration of normal saline(NS) or JCH in normal rats and gastric wall injured rats. To evaluate the mechanism of JCH under delayed gastric emptying conditions, normal rats were treated with atropine sulfate(1mg/kg, s.c.), quinpirole HCl(0.3mg/kgg, i.p.), $NAME(N^{G}-nitro-L-arginine$ methyl ester, 75mg/kg s.c.) and cisplatin(10mg/kg, i.p.). The gastric slow waves were measured for 30 minutes before and after administration of each solution(NS, JCH). Results : JCH 110.1mg/kg improved gastric emptying for 2 hrs(p=0.014). JCH 110.1mg/kg improved gastric emptying in the gastric wall injured rats(p=0.001). Under the delayed gastric emptying, JCH 110.1mg/kg improved gastric emptying in the group treated with atropine $sulfate(1.83{\pm}0.96$ vs $8.43{\pm}8.46$, p=0.003), but aggravated it with quinpirole $HCl(4.7{\pm}2.9$ vs $1.61{\pm}2.09$, p=0.021). Administration JCH 110.1mg/kg increased EGG power in rats. Conclusions : JCH stimulates gastric motility through the cholinergic pathway, so we expect that it would be effective in the treatment of dysmotility-like functional dyspepsia with low activity of vagus nerve.

  • PDF

Origin and Characteristics of Sand Ridges in the western Continental Shelf of Korean Peninsula (한반도 서부대륙붕에 발달한 사퇴의 발생기원과 특성)

  • 방효기;이차원
    • 한국해양학회지
    • /
    • v.29 no.3
    • /
    • pp.217-227
    • /
    • 1994
  • From northeast to southwest, discontinuous sand ridges distribute on the western continental shelf of Korean Peninsular. The dimension of sand ridges is 3 to 21 m high, 3.1 to 6.8 km wavelength and 9-64 km long with 0.5 steep slope. they are probably originated and reformed by the intensity of tidal current according to the sea level rise. The characteristics of sand ridges revealed in study area are summarized as follows: (1) The sand ridges line up with the long axes of the tidal current ellipses, indicating a tidal control. (2) these are composed of two sedimentary sequences on the 3.5 kHz seismic profiles and core sediments. The upper sequence characterized by prolonged type is covered with thin veneer of massive fine sand(Mz, 2-3$\phi$) with Olive Gray(5Y 5/2). The lower sequence is characterized by internal reflector type with parallel and discontinuous. It consists of sandy mud or muddy sand(Mz, 5-7$\phi$) with laminar structures. the parallel internal reflectors are truncated on the slope of sand ridges. (3) Asymmetrical sand waves are superimposed on the sand ridges, and facing to the crest. However, symmetrical sand waves lie on the crest. Sand ridges having characteristics above is originated by scouring of tidal current, covered with coarase relict sediments, and modified by sadware.

  • PDF

Behavior of Walls of Open-cell Caissons Using Filler under Abnormally High Waves (고파랑 대비 채움재를 이용한 오픈 셀 케이슨의 전단 벽체 거동 분석)

  • Seo, Jihye;Won, Deokhee;Park, Woo-Sun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.29 no.2
    • /
    • pp.83-91
    • /
    • 2017
  • In order to cope with the abnormally high waves during the storm surge due to climate change, various methods have been proposed for interlocking adjacent caissons to enhance stability of harbor structures. Among the methods, it was studied the method based on an open-cell caisson having reduction effect increasing the cohesion with adjunction caissons by filling materials such as crushed rocks in an inter-cell formed by two facing open-cells which consist of transverse walls. It is necessary to investigate the shear behaviors of an inter-cell to secure the stability using calculating shear forces on inter-cell under oblique wave loadings. It was analyzed the shear force share ratio with the length of internal and external wall and the number of internal walls. Numerical results show that 60~70% of the shear load is transmitted to adjacent caisson through the internal walls, more than 30% is through the external wall. It was applicable in the assumption that filling materials was uniformly distributed in inter-cells, and further studies were worth consideration on other conditions under construction.