• Title/Summary/Keyword: Internal Resonance

Search Result 666, Processing Time 0.023 seconds

Granulomatous Meningoencephalitis in an Old Dog ; magnetic resonance imaging and immunohistopathologic findings (노령견에서 병발한 육아종성 뇌수막염 증례 보고: 자기 공명 영상 및 면역조직병리학 소견)

  • Jung, Dong-In;Yoo, Jong-Hyun;Kang, Byeong-Teck;Park, Chul;Gu, Su-Hyun;Kim, Ju-Won;Jeon, Hyo-Won;Lee, So-Young;Woo, Eung-Je;Sur, Jung-Hyang;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.406-409
    • /
    • 2007
  • A 12-year-old female mixed Chihuahua dog was referred because of acute blindness and progressive tetraparesis. Mutifocal lesions in the cerebrum were noted on brain magnetic resonance images and cerebrospinal fluid analysis showed monocytic pleocytosis. Based on these results, granulomatous meningoencephalitis (GME) was strongly suspected. Cerebral lesions were definitely diagnosed as GME based on histopathological findings and positive results of immunohistological stains of brain with T-cell marker (CD3). This report describes the clinical findings, diagnostic imaging characteristics, and immunohistopathologic features of GME in an old dog. In addition, this case demonstrates that clinical signs of GME were mediated by perivascular infiltration of T lymphocytes and identification of causes in T cell-mediated inflammation should be further studied.

Development of NMR Based Prototype Sensor for Non-destructive Sugar Content Measurement in Fruits. (수소 핵자기공명을 이용한 과실의 비괴적 당도측정 시작기의 개발)

  • 조성인;정창호
    • Journal of Biosystems Engineering
    • /
    • v.21 no.3
    • /
    • pp.336-342
    • /
    • 1996
  • A 4.1MHz$1^H$ Nuclear Magnetic Resonance(NMR) sensor was designed and manufactured to evaluate the internal quality of fruits. The magnet console having 963gauss magnetic field induction was used for the NMR sensor. To optimize and evaluate the NMR sensor, glycerol and sugar-water solutions were used. $^1$H(proton) resonance signals were used to estimate the sugar contents in fruits. Artificial neural network models were developed to predict sugar contents in fruits from the proton resonance signals. The standard errors of prediction(SEP) were 0.565(apple), 0.394(pear) and 0.415(kiwi), respectively. The result implied that it was possible to evaluate apple, pear and kiwi into 3 grades using the NMR sensor.

  • PDF

Resonance Frequency of the Natural Convection in the Closure Cavity for the Variable Aspect Ratio (종횡비가 변하는 공동 내 자연대류의 공진주파수)

  • Chun, Kun-Ho;Joo, Kwang-Sup;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.609-614
    • /
    • 2000
  • This numerical study investigate resonance frequency of natural convection for steady state, periodic flow and chaotic flow in two-dimensional direct numerical simulations, differentially heated, vertical cavities having aspect ratios near unity. The enclosure cavity has isothermal and time dependent temperature side walls and adiabatic top/bottom walls. The aspect ratio is 1/3, 1/2, 1, 2, and 3 for the varying Rayleigh number. Resonance frequency for AR=1 has decrease as the aspect ratio and the Rayleigh number are increasing.

  • PDF

Resonance frequency shifts of Helmholtz resonator array panel brought by change in resonator arrangements (공명기 분포에 따른 공명기 배열형 패널의 공명주파수 변화)

  • Kim, Sang-Ryul;Kim, Yang-Han
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.97-100
    • /
    • 2005
  • Precise prediction of resonance frequency has been the subject of numerous papers related to Helmholtz resonator design because of its high performance at the frequency. The resonance frequency is dependent upon not only the internal dimensions of resonator but also the external boundary conditions such as the existence of other resonators in Helmholtz resonator array panel. However, the latter effect, which changes the external end correction of resonator, has not been well studied. We propose a formula to calculate the radiation impedance (or external end correction) of Helmhoitz resonator array panel. Any distance between adjacent resonators and any angle of Incidence can be allowed in the method. Numerical examples show how and how much the distance affects the resonance frequency of the panel. It is also found that the maximum absorption of the panel varies with the resonator arrangement.

  • PDF

Prototype of NMR Based Sensor For Non-Destructive Sugar Content Measurement in Fruits

  • Cho, Seoung-In;Chung, Chang-Ho
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.305-312
    • /
    • 1996
  • A 4.1MHz 1H Nuclear Magnetic Resonance (NMR) sensor was designed and manufactured to evaluate the internal quality of fruit. The magnet console having 963 gauss magnetic field induction was used for the NMR sensor. To optimize evaluate the NMR sensor, glycerol and sugar-water solutions were used. 1H(proton) resonance signals were use of to estimate the sugar contents in fruits the proton resonance signals and were validated . The standard errors of predictions(SEP) were 0.565(apple) , 0.394(pear) and 0.415(kiwi) respectively. The result implied that is possible to evaluate apple , pear and kiwi into 3 grades using the NMR sensor.

  • PDF

A Boundary Protection for Power Distribution Line Based on Equivalent Boundary Effect

  • Zhang, Xin;Mu, Long-Hua
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.262-270
    • /
    • 2013
  • A boundary protection method for power distribution line based on equivalent boundary effect is presented in this paper. In the proposed scheme, the equivalent resonance component with a certain central frequency is sleeve-mounted at the beginning of protected zone. The 'Line Boundary' is built by using boundary effect, which is created by introducing impedance in the primary-side of line. The 'Line Boundary' is significantly different from line wave impedance. Therefore, the boundary protection principle can be applied to power distribution line without line traps. To analyze the frequency characteristic corresponding to traveling-waves of introducing impedance in the primary-side of line, distributed parameters model of equivalent resonance component is established. The results of PSCAD/EMTDC simulation prove the obvious difference of voltage high frequency component between internal faults and external faults due to equivalent resonance component, and validate the scheme.

Detailed Study on Insulation Coordination of a 25kV Power System Connected with a VCB and Transformer

  • Baek, Byung-San;Kim, Yong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1245-1249
    • /
    • 2017
  • Recently, unusual transformer failures have been reported in 25kV power systems connected with a VCB and transformer. In this study, performance of the protection system, dielectric strength of the transformers, characteristics of switching surges and resonance phenomena were analysed and assessed. All investigations regarding the insulation breakdown of the transformers were carried out by simulations, laboratory tests, factory tests and on-site measurements in order to thoroughly investigate the root causes. Furthermore, experimental methods for investigating the resonance phenomenon were derived and tests were conducted applying the derived method to recreate the phenomenon in the transformer. It is found that resonance between the transformer and switching surge generated by closing a VCB can initiate the breakdown of internal windings of a transformer.

Positional and morphologic changes of the temporomandibular joint disc using magnetic resonance imaging

  • Ahn Hyoun-Suk;Cho Su-Beom;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.235-240
    • /
    • 2001
  • Purpose: To evaluate displacement and morphologic changes of the temporomandibular joint (TMJ) disc in patient with internal derangement using magnetic resonance imaging (MRI). Materials and Methods: One hundred and forty five MR images of TMJs in 73 patients were evaluated. Positional and morphologic changes of the TMJ discs were assessed. Lateral or medial disc displacement was also evaluated on coronal images. Results: Among 63 discs with anterior disc displacement, 37 discs were assessed as a biconcave disc and 21 as a deformed disc. Rotational disc displacement was observed in 35 discs. Anteromedial disc displacement was observed in 29 discs, and anterolateral direction in 6 discs. Among 35 rotational displacement, 5 biconcave discs and 21 deformed discs were observed. Conclusion : Rotational and sideways displacement of TMJ discs were found to be common and an important aspect of internal derangement. This study also suggests that sagittal and coronal images of the TMJ have complementary abilities for an assessment of joint abnormality.

  • PDF

Nonlinear Analysis of a Forced Beam with Internal Resonances (내부공진을 가진 보의 비선형 강제진동해석)

  • 이원경;소강영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1897-1907
    • /
    • 1991
  • An analysis is presented for the primary resonance of a clamped-hinged beam, which occurs when the frequency of excitation is near one of the natural frequencies, .omega.$_{n}$. Three mode interactions, .omega.$_{2}$=3.omega.$_{1}$, and .omega.$_{3}$=.omega.$_{1}$+2.omega.$_{2}$, are considered and their influence on the response is studied. The case of two mode interaction, .omega.$_{2}$=3.omega.$_{1}$, is also considered in order to compare it with the case of three mode interactions. The straight beam experiencing mid-plane stretching is governed by a nonlinear partial differential equation. By using Galerkin's method the governing equation is reduced to a system of nonautonomous nonlinear ordinary differential equations. The method of multiple scales is applied to obtain steady-state responses of the system. Results of numerical investions show that there exists no significant difference between both modal interactions.

Development of Vibrator for Magnetic Resonance Elastography (자기공명 탄성계수 영상법을 위한 진동기의 개발 및 기초실험)

  • Lee, Tae-Hwi;Suh, Yong-Seon;Kim, Young-Tea;Lee, Byung-Il;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.75-83
    • /
    • 2007
  • Elasticity is an important physical property of biological tissues. Differences in elasticity can help facilitate the diagnosis of tumors and their extent. Magnetic Resonance Elastography (MRE) tries to visualize images of tissue elasticity by externally applying shear stress on the surface of an imaging object. Applied shear stress induces internal displacements that can be measured from MR phase images. In order to conduct MRE imaging experiments, we need to first develop a vibrator. We found that there does not exist enough technical information to design the MRE vibrator. In this paper, we describe the theory, design and construction of an MRE vibrator. We report the performance of the developed vibrator using two different test methods. We found that the vibrator successfully induces enough internal displacements that can be imaged using an MRI scanner. We suggest future studies of numerous MRE imaging experiments using the vibrator.