• Title/Summary/Keyword: Internal Power

Search Result 2,251, Processing Time 0.025 seconds

The Effects of Apparel Stores' Internal Marketing and Internal Customer Relationship Management on Employees' Attitude toward Change (의류전문 점포에서 내부마케팅과 내부고객관계관리가 종업원들의 변화에 대한 태도에 미치는 영향)

  • Row, Young;Park, Jae-Ok;Lee, Kyu-Hye
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.3 s.162
    • /
    • pp.387-397
    • /
    • 2007
  • Due to the recent trend of relationship marketing and characteristics of the apparel retail industry that relys heavily on employees' performance, internal marketing toward the employees gives a critical influence on firms' overall performance. This study is aiming at the factors of internal marketing and relationship management that enhance positive attitude toward change. A survey questionnaire was developed and about two hundreds department store sales staffs working for apparel brands participated in the empirical study. Factor analysis ensured the existence of five aspects of internal marketing: educational training, internal communication, power endorsement, management capability and incentive system. Results indicated that age, marital status, years of employment, position rank, and salary types of salespersons had significant influence on internal marketing factors. Incentive system had significant influence on internal customer relationship management. Internal customer relationship management had significant impact on employees' attitude toward change. Educational training had significant influence on employees' perceived importance of change. Educational training, power endorsement and incentive system affected employees' perceived outcome of change.

Finite Element Analysis of Power Steering Hose Subject to Internal Pressure (내압을 받는 파워스티어링 호스의 유한요소해석)

  • Cho, Jin-Rae;Jeon, Do-Hyung;Roh, Gi-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.2
    • /
    • pp.181-188
    • /
    • 2004
  • The objective of this paper is to numerically examine the mechanical behavior of the swaged power steering(PS) hose subject to internal pressure. PS hose experiences a large internal pressure change in operating, so it's material part has to resist a cyclic expansion and compression without causing oil leakage. This cyclic pressure is intimately associated with fatigue failure of PS hose. In this study, we compare two types of PS hose. The numerical investigation is composed of three steps; swaging analysis, low and high pressure analyses. The comparative numerical results provide the basic data for the optimal PS design.

Study on the Quantitative Rod Internal Pressure Design Criterion (정량적인 핵연료봉 내압 설계기준에 관한 연구)

  • Kim, Kyu-Tae;Kim, Oh-Hwan;Han, Hee-Tak
    • Nuclear Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.363-373
    • /
    • 1991
  • The current rod internal pressure criterion permits fuel rods to operate with internal pressures in excess of system pressure only if internal overpressure does not cause the diametral gap enlargement. In this study, the generic allowable internal gas pressure not violating this criterion is estimated as a function of rod power. The results show that the generic allowable internal gas pressure decreases linearly with the increase of rod power. Application of the generic allowable internal gas pressure for the rod internal pressure design criterion will result in the simplication of the current design procedure for checking the diametral gap enlargement caused by internal overpressure because according to the current design procedure the cladding creepout rate should be compared with the fuel swelling rate at each axial node at each time step whenever internal pressure exceeds the system pressure.

  • PDF

PWSCC and System Engineering Development of Internal Inspection and Maintenance Methodology for RCS

  • Abdallah, Khaled Atya Ahmed;Mesquita, Patricia Alves Franca de;Yusoff, Norashila;Nam, GungIhn;Jung, JaeCheon;Lee, YoungKwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.89-103
    • /
    • 2016
  • Due to safety of the plant, it became very clear the importance of study occurrence reactor coolant system (RCS) issues specially the primary water stress corrosion cracking (PWSCC). The Systems Engineering (SE) approach is characterized by the application of a structured engineering methodology for the design of a complex system or component. Robotic devices have been used for internal inspection, maintenance and performing remote welding and inspection in high-radiation areas. In this paper, PWSCC overview and inlay and over lay welding methodology introduced, concept of robotic device that can be inserted into the piping via Steam Generator (SG) main way to access to primary piping of pressurized water reactor (PWR) is developed based on SE methodology. A 3D model of the inspection system was developed along with the APR1400 (Advanced Power Reactor)reactor coolant systems (RCS) and internals with virtual 3D simulation of the operation for visualization to prove the validity of the concept.

Performance and Internal Flow of a Cross-Flow Type Hydro Turbine for Wave Power Generation (파력발전용 횡류형 수력터빈의 성능 및 내부유동)

  • Choi, Young-Do;Cho, Young-Jin;Kim, You-Taek;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.3
    • /
    • pp.22-29
    • /
    • 2008
  • Clean and renewable energy technologies using ocean energy give us non-polluting alternatives to fossil and nuclear-fueled power plants to meet establishment of countermeasures against the global warming and growing demand for electrical energy. Among the ocean energy resources, wave power takes a growing interest because of its enormous amount of potential energy in the world. Therefore, various types of wave power conversion system to capture the energy of ocean waves have been developed. However, suitable turbine type is not normalized yet because of relatively low efficiency of the turbine systems. The purpose of this study is to investigate the internal flow and performance characteristics of a cross-flow type hydro turbine, which will be built in a caisson for wave power generation. Numerical simulation using a commercial CFD code is conducted to clarify the effects of the turbine rotation speed and flow rate variation on the turbine characteristics. The results show that the output power of the cross-flow type hydro turbine with symmetric nozzle shape is obtained mainly from Stage 2. Turbine inlet configuration should be designed to obtain large amount of flow rate because the static pressure and absolute tangential velocity are influenced considerably by inlet flow rate.

Characteristics of Ozonizer with Variation of Vaccum in Internal Electrode (고주파전원형 오존발생기의 방전 캡 변화 특성)

  • 이창호;전병준;이상근;송현직;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.381-385
    • /
    • 2003
  • In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating $\circled1$ discharge characteristics with variation of output voltage power supply, flow rate and gap $\circled2$ ozone generation characteristics with variation of flow rate, gap and discharge power. pure oxygen was used as process gas of the co-axial type ozonizer. In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured. Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.

  • PDF

The Combined Effects of Power Imbalance and Mutual Dependence on the Relationship between IOS Diffusion and a Firm's Performance Improvement

  • Gee-Woo Bock;Sang Cheol Park;Won Jun Lee;Cheng Zhang;Kyu Min Hwang
    • Asia pacific journal of information systems
    • /
    • v.29 no.2
    • /
    • pp.217-247
    • /
    • 2019
  • This paper draws on the interdependence theory to examine the role of power and mutual dependence on the relationship between internal/external diffusion and performance improvement within a supply chain. The results from a survey of 375 respondents show that two patterns of IOS diffusion - internal diffusion and external diffusion - have different impacts on a firm's performance improvement according to differences in power and mutual dependence between two parties in the supply chain.

Characteristics of Vaccum Variation Type Ozonizer of Internal Electrode (내부전극의 전공도 변화형 오존발생기의 특성)

  • 이창호;전병준;김영재;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.387-391
    • /
    • 2003
  • In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.

  • PDF

Differenting Effects of Cerebral Hemispheric Lateralization and Gender by Power Spectral Analysis of Heart Rate Variability in Cerebrovascular disease (뇌졸중(腦卒中) 환자(患者)의 성별(性別)과 부위(部位)에 대한 Heart Rate Variability의 변화(變化))

  • Ji Nam-Gyu;Lee Kyung-Sup;Moon Sang-Kwan;Ko Chang-Nam;Cho Ki-Ho;Kim Young-Suk;Bae Hyung-Sup
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.7-16
    • /
    • 1998
  • Background and Purpose The increasing evidence for neurally mediated cardiac damage and sudden death has focused attention on the central autonomic control of cardiac function. Power spectral analysis of heart rate variability(HRV) can detect autonomic consequences of stroke. We performed power spectral analysis of heart rate variability from 24-hour holter recording to identify cerebral hemispheric lateralization and gender effect in cardiac autonomic control. Methods Data were obtained from 24-hour holter recordings in 30 consecutive patients with hemispheric brain infarction in the subacute phase. We analysed the time domain and frequency domain measures of HRV and ST segment by hemispheric lateralization and Gender. Results ST segment was depressed in women compared with man. There was no statistically significant differences between right and left hemisphere stroke patients in any standard index of HRV and ST segment changes. Conclusions These data are partial consistent with evidence from the recent literature that two cerebral hemispheres and gender have a differential influence on the nature and severity of cardiac dysfunction. We think the prospective and definite study was necessary.

  • PDF

Improvement of internal exposure assessments of the inhalation of fuel-type hot particles during long-term outages

  • Moonhyung Cho;Hyeongjin Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3925-3932
    • /
    • 2024
  • During outages at nuclear power plants, much more care for radiation workers against internal exposure should be ensured given that more hot particles exist relative to the amount during normal operation. If fuel-type hot particles (FTHP) are inhaled, they can cause more severe health risks compared to activation-type hot particles (ATHP), which contain 60Co, due to the alpha-emitting nuclides within FTHPs. The activities of difficult-to-measure nuclides within FTHPs inhaled by workers are inferred by the age-dating technique using a141Ce/144Ce ratio as measured by whole-body counters. However, this method may be limited to outages that last for only a few months due to the short half-life (32.5 days) of 141Ce. We studied the feasibility of utilizing 241Am, a nuclide with a long half-life of 432.6 years, as an alternative to 141Ce. Additionally, we improved the performance of a stand-type whole-body counter for low-energy gamma spectroscopy to meet the criterion (RMSE ≤0.25) specified in ANSI/HPS N13.30-2011 by employing an artificial neural network (ANN). This study can contribute to more rapid and accurate internal dose assessments for workers who have inhaled FTHPs during long-term outages at nuclear power plants.