• Title/Summary/Keyword: Internal Monitoring

Search Result 846, Processing Time 0.029 seconds

Development of a Monitoring System Based on the Cooperation of Image and Sensor Information (영상 정보와 센서 정보의 협업에 의한 모니터링시스템 개발)

  • Kwon, Cha-Uk;Cha, Kyung-Ae;Kim, Joo-Sung
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.2
    • /
    • pp.46-56
    • /
    • 2010
  • This study proposes a monitoring system by cooperating the image information and the sensor information in a sensor network system. The monitoring system proposed in this study is divided into internal spaces, such as offices and laboratories, and external spaces including other various spaces. In the internal spaces, motions in objects are detected through cameras while some peripherals like lights are controlled by analyzing some temperature, humidity, and illuminance data detected by sensor nodes. In the external spaces, it is to watch certain intruders to the internal spaces through the interested region for exceptional time by installing cameras, motion detectors, and body detectors in such interested regions. In the results of the test that was applied to a practically limited environment by implementing some interfaces for the proposed system, it was considered that it is possible to watch surroundings effectively using the image information obtained from cameras and sensor information acquisited from sensor nodes.

Selected ion monitoring analysis of conjugated metabolites of methadone using biosynthetic internal standards for the study of methadone-diazepam interaction

  • Kang, Gun-Il
    • Archives of Pharmacal Research
    • /
    • v.6 no.1
    • /
    • pp.7-16
    • /
    • 1983
  • A methadone-diazepam interaction study in rats was performed in which conjugated metabolites of methadone were analyzed using deuterated biosynthetic internal standards. Diazepam (5mg/kg) was given to rats through a cannulate djugular vein and a subcutaneous dose of methadone (10mg/kg) was given. Bile was collecte through the cannulate dbile duct over a period of 24 hours. The deuterium label of the internal standards was found to be stable under conditions of the prolonged incubation. There was no significant difference in the excretion of the metabolites between the control and the diazepam treated rats. Feasibility of using biosynthetic internal standards with selected ion monitoring was established for the drug metabolism and kinetic studies.

  • PDF

Tuberculosis Surveillance and Monitoring under the National Public-Private Mix Tuberculosis Control Project in South Korea 2016-2017

  • Min, Jinsoo;Kim, Hyung Woo;Ko, Yousang;Oh, Jee Youn;Kang, Ji Young;Lee, Joosun;Park, Young Joon;Lee, Sung-Soon;Park, Jae Seuk;Kim, Ju Sang
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.3
    • /
    • pp.218-227
    • /
    • 2020
  • Background: The national Public-Private Mix (PPM) tuberculosis (TB) control project provides for the comprehensive management of TB patients at private hospitals in South Korea. Surveillance and monitoring of TB under the PPM project are essential toward achieving TB elimination goals. Methods: TB is a nationally notifiable disease in South Korea and is monitored using the surveillance system. The Korea Centers for Disease Control and Prevention quarterly generates monitoring indicators for TB management, used to evaluate activities of the PPM hospitals by the central steering committee of the national PPM TB control project. Based on the notification date, TB patients at PPM hospitals were enrolled in each quarter, forming a cohort, and followed up for at least 12 months to identify treatment outcomes. This report analyzed the dataset of cohorts the first quarter of 2016 through the fourth quarter of 2017. Results: The coverage of sputum, smear, and culture tests among the pulmonary TB cases were 92.8% and 91.5%, respectively. The percentage of positive sputum smear and culture test results were 30.7% and 61.5%, respectively. The coverage of drug susceptibility tests among the culture-confirmed cases was 92.8%. The treatment success rate among the smear-positive drug-susceptible cases was 83.2%. The coverage of latent TB infection treatment among the childhood TB contacts was significantly higher than that among the adult contacts (85.6% vs. 56.0%, p=0.001). Conclusion: This is the first official report to analyze monitoring indicators, describing the current status of the national PPM TB control project. To sustain its effect, strengthening the monitoring and evaluation systems is essential.

Study on Outbound Traffic Monitoring with Bloom Filter (블룸필터를 이용한 아웃바운드 트래픽 모니터링 방안 연구)

  • Kang, Seong-Jung;Kim, Hyoung-Joong
    • Journal of Digital Contents Society
    • /
    • v.19 no.2
    • /
    • pp.327-334
    • /
    • 2018
  • When a PC is infected with a malicious code, it communicates with the control and command (C&C) server and, by the attacker's instructions, spreads to the internal network and acquires information. The company focuses on preventing attacks from the outside in advance, but malicious codes aiming at APT attacks are infiltrated into the inside somehow. In order to prevent the spread of the damage, it is necessary to perform internal monitoring to detect a PC that is infected with malicious code and attempts to communicate with the C&C server. In this paper, a destination IP monitoring method is proposed in this paper using Bloom filter to quickly and effectively check whether the destination IP of many packets is in the blacklist.

Experimental Study on Flow Noise in a T-Junction Pipe at Different Flow Velocity (유동속도에 따른 T-접합관의 유동소음에 관한 실험적 연구)

  • Jian-bin Hu;Hou-lin Liu;Kai Wang;Guang-xin Ding;Yu-bo Jin;He-ming Liu;Hyoung-bum Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.2
    • /
    • pp.55-62
    • /
    • 2024
  • Using an internal flow noise test bench, this study investigates the variation in internal flow noise at the inlet and outlet monitoring points of a DN100 T-junction pipe under different flow velocities. Results indicate that with increasing flow velocity, both the sound pressure level and total sound pressure level at the inlet and outlet monitoring points increase. The highest total sound pressure level is observed at the vertical outlet monitoring point B, followed by the horizontal inlet monitoring point A, with the lowest at the horizontal outlet monitoring point C. At a constant flow velocity, the sound pressure level at the inlet and outlet points initially increases and then decreases as frequency increases.

Study on the Real-Time Leak Monitoring Technique for Power Plant Valves (발전용 밸브누설 실시간 감시기술 연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Review on the Relationship of Dissolved Gas Analysis and Internal Inspection of Transformer (변압기 절연재료 분석과 내부점검 결과와의 상관성 연구)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Jung, Nyun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1869-1873
    • /
    • 2010
  • For reliable operation of oil-filled electrical equipment, monitoring and maintenance of insulating oil is essential. Dissolved gas analysis(DGA) is widely used for monitoring faults in high voltage electrical equipment in service. Therefore, oil analysis should be monitored regularly during its service life. KEPCO has investigated thousands of dissolved gas analysis data since 1985, and conducted studies on the relationship of gas in oil analysis and internal inspection results of transformer. As the results, KEPCO revised criteria for transformer diagnosis and has applied it since 2008. Almost of 100 cases of internal inspection results since 2001 have been investigated. This paper presents the correlation of the fault-identifying gases with faults found in actual transformers and how should we approach to internal inspection of transformer by dissolved gas analysis.

A Case Report of Integrative Treatment in a Type 2 Diabetes Patient with Multiple Symptoms and Evaluation Using Continuous Glucose Monitoring (소갈 증상을 호소하는 제2형 당뇨 환자에서의 한양방 병행치료 치험 1례와 연속 혈당 측정기를 이용한 평가)

  • Woo-nyoung Jung;Mee-ryoung Song;Yeon-joo Yoo;Min-seong Lee;Young-min Ahn;Se-young Ahn;Byung-cheol Lee
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.2
    • /
    • pp.303-313
    • /
    • 2024
  • Introduction: We describe the effects of Sosiho-tang decoction and insulin combination therapy, as well as the effect of integrated traditional Korean medicine therapy, using continuous glucose monitoring (CGM) in a diabetic patient complaining of a range of diabetic symptoms. Case report: A 24-year-old female presented with symptoms of diabetes, including weight loss, thirst, and polyuria, and was diagnosed with type 2 diabetes through blood tests, endocrine tests, and autoantibody tests. During hospitalization, the patient received insulin therapy and Sosiho-tang decoction concurrently, achieving normal blood glucose levels. After discharge, adhering to the Sosiho-tang decoction and CGM enabled the insulin dosage to be gradually reduced while maintaining normal blood glucose levels. Conclusion: Combination therapy with insulin and Sosiho-tang rapidly reduced hyperglycemia in the short term. CGM post-discharge allowed for observation of the patient's blood glucose levels. Ultimately, Sosiho-tang medication lowered blood glucose levels, reduced insulin requirements, and facilitated a reduction in the insulin dosage.

Evaluation of Glucose Concentration by Wireless Continuous Glucose Monitoring System in Healthy Dogs (무선 연속 당측정기에 의한 정상 개의 당 농도 평가)

  • Kang, Ji-Houn;Kim, Sung-Soo;Yang, Mhan-Pyo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.392-396
    • /
    • 2010
  • Blood glucose curves in the management for diabetic patients have several limitations including intermittent assessment of blood glucose concentration, hospitalization, patient restraint, and repeated phlebotomy. The aim of this study was to apply and evaluate a wireless continuous glucose monitoring system (CGMS) in healthy dogs. Subcutaneous interstitial glucose concentrations in 7 dogs were continuously monitored and recorded by wireless CGMS. During induced hyperglycemia, the interstitial glucose concentrations were compared with whole blood glucose concentrations measured by glucometer and serum glucose concentrations measured by automated chemistry analyzer, respectively. There were no significant differences among interstitial, whole blood and serum glucose concentrations. The interstitial glucose concentrations had a good correlation to serum glucose concentrations. The real-time wireless CGMS is a valuable tool for monitoring system of glucose concentrations in dogs. Use of the CGMS for diabetic patients will provide accurate information over traditional blood glucose curves.