Abstract
Blood glucose curves in the management for diabetic patients have several limitations including intermittent assessment of blood glucose concentration, hospitalization, patient restraint, and repeated phlebotomy. The aim of this study was to apply and evaluate a wireless continuous glucose monitoring system (CGMS) in healthy dogs. Subcutaneous interstitial glucose concentrations in 7 dogs were continuously monitored and recorded by wireless CGMS. During induced hyperglycemia, the interstitial glucose concentrations were compared with whole blood glucose concentrations measured by glucometer and serum glucose concentrations measured by automated chemistry analyzer, respectively. There were no significant differences among interstitial, whole blood and serum glucose concentrations. The interstitial glucose concentrations had a good correlation to serum glucose concentrations. The real-time wireless CGMS is a valuable tool for monitoring system of glucose concentrations in dogs. Use of the CGMS for diabetic patients will provide accurate information over traditional blood glucose curves.
Keywords
blood glucose concentration; continuous glucose monitoring system; diabetes mellitus; dog;
Citations & Related Records

Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 Davison LJ, Slater LA, Herrtage ME, Church DB, Judge S, Ristic JM, Catchpole B. Evaluation of a continuous glucose monitoring system in diabetic dogs. J Small Anim Pract 2003; 44: 435-442.   DOI   ScienceOn
2 Rieder J, Seipel J, Vaske B, Rohn K, Simon D, Nolte I. Comparison of wireless and conventional continuous glucose monitoring system (CGMS) in 4 dogs. J Vet Intern Med 2009; 23: 754.
3 Ristic JM, Herrtage ME, Walti-Lauger SM, Slater LA, Church DB, Davison LJ, Catchpole B. Evaluation of a continuous glucose monitoring system in cats with diabetes mellitus. J Feline Med Surg 2005; 7: 153-162.   DOI   ScienceOn
4 Wiedmeyer CE, DeClue AE. Continuous glucose monitoring in dogs and cats. J Vet Intern Med 2008; 22: 2-8.   DOI   ScienceOn
5 Wiedmeyer CE, Johnson PJ, Cohn LA, Meadows RL. Evaluation of a continuous glucose monitoring system for use in dogs, cats, and horses. J Am Vet Med Assoc 2003; 223: 987-992.   DOI   ScienceOn
6 Wiedmeyer CE, Johnson PJ, Cohn LA, Meadows RL, Kerl ME, Tessman RK, Perlis J, DeClue AE. Evaluation of a continuous glucose monitoring system for use in veterinary medicine. Diabetes Technol Ther 2005; 7: 885-895.   DOI   ScienceOn
7 Affenzeller N, Benesch T, Thalhammer JG, Willmann M. A pilot study to evaluate a novel subcutaneous continuous glucose monitoring system in healthy Beagle dogs. Vet J 2010; 184: 105-110.   DOI   ScienceOn
8 Rand JS, Martin GJ. Management of feline diabetes mellitus. Vet Clin North Am Small Anim Pract 2001; 31: 881-913.
9 Bilicki KL, Schermerhorn T, Klocke EE, McMurphy RM, Roush JK. Evaluation of a real-time, continuous monitor of glucose concentration in healthy dogs during anesthesia. Am J Vet Res 2010; 71: 11-16.   DOI   ScienceOn
10 Fleeman LM, Rand JS. Management of canine diabetes. Vet Clin North Am Small Anim Pract 2001; 31: 855-880.