• Title/Summary/Keyword: Internal Matching

Search Result 185, Processing Time 0.027 seconds

The Design of a Code-String Matching Processor using an EWLD Algorithm (EWLD 알고리듬을 이용한 코드열 정합 프로세서의 설계)

  • 조원경;홍성민;국일호
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.4
    • /
    • pp.127-135
    • /
    • 1994
  • In this paper we propose an EWLD(Enhanced Weighted Levenshtein Distance) algorithm to organize code-string pattern matching linear array processor based on the mappting to an one-dimensional array from a two-dimensional matching matrix, and design a processing element(PE) of the processor, N PEs are required instead of NS02T in the processor because of the mapping. Data input and output between PEs and all internal operations of each PE are performed in bit-serial fashion. The bit-serial operation consists of the computing of word distance (WD) by comparison and the selection of optimal code transformation path, and takes 22 clocks as a cycle. The layout of a PE is designed based on the double metal $1.5\mu$m CMOS rule. About 1,800 transistors consistute a processing element and 2 PEs are integrated on a 3mm$\times$3mm sized chip.

  • PDF

Ratcheting boundary of pressurized pipe under reversed bending

  • Chen, Xiaohui;Chen, Xu;Li, Zifeng
    • Steel and Composite Structures
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2019
  • Ratcheting boundary is firstly determined by experiment, elastic-plastic finite element analysis combined with C-TDF and linear matching method, which is compared with ASME/KTA and RCC-MR. Moreover, based on elastic modulus adjustment procedure, a novel method is proposed to predict the ratcheting boundary for a pressurized pipe subjected to constant internal pressure and cyclic bending loading. Comparison of ratcheting boundary of elbow pipe determined by the proposed method, elastic-plastic finite element analysis combined with C-TDF and linear matching method, which indicates that the predicted results of the proposed method are in well agreement with those of linear matching method.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

The Beauty of Line on Men′s Costume in the Chosun Period (조선시대 남자복식에 표현된 선(線)의 미(美))

  • 도주연;권영숙
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.4
    • /
    • pp.517-536
    • /
    • 2000
  • The purpose of this study is to investigate the internal and external line beauty of men's dress of the Chosun period from the views of dress design and dress aesthetics. 1) External Line Beauty of Men's Dress of the Chosun Period ① Functional Beauty : Having the beauty of functional line in terms of convenience, action, effectiveness, practivce and sanitation. ② Structural Beauty : Having the beauty harmonizing between lines of internal and external structures. ③ Ornamental Beauty : Having the beauty of simple line by matching accessories (gat, fan, sejodae, shoes) with a simple dress. ④ Wearing Beauty : Making tall-looking or expressing a mature masculine beauty by a visual mistake caused by a combination of internal and external structural beauty lines. 2) Internal Line Beauty of Men's Dress of the Chosun Period Including a simple but natural beauty based on natural philosophy, the beauty of courtesy emphasizing official hat and dress and the beauty of dress having aesthetic consciousness with which people enjoy an idyllic life.

  • PDF

Hand-effect compensation circuit design using the low-voltage MEMS switch in the handset (저전압 MEMS 스위치를 적용한 휴대단말기의 인체효과 보상회로 설계)

  • Kim, Wang-Jin;Lee, Kook-Joo;Park, Yong-Hee;Kim, Moon-Il
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • In this paper, the external matching circuits were designed in order to compensate the efficiency which decreases by human body effect in the internal antenna phone. Comparing the two types of matching circuit, we selected the structure to minimize the switch stress. RF MEMS switch using low voltage was compared with FET switch and measured the performance in the handset. Here, the detection circuit which can couple th reflection power from antenna was added in the handset and we set up the demonstration system that can compensate the loss of hand effect automatically. In this system, when hand effect occurred, the radiation power increased 2.5dB by operation the matching circuit.

  • PDF

An Improved Signature Hashing-based Pattern Matching for High Performance IPS (고성능 침입방지 시스템을 위해 개선한 시그니처 해싱 기반 패턴 매칭 기법)

  • Lee, Young-Sil;Kim, Nack-Hyun;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.434-437
    • /
    • 2010
  • NIPS(Network Intrusion Prevention System) is in line at the end of the external and internal networks which performed two kinds of action: Signature-based filtering and anomaly detection and prevention-based on self-learning. Among them, a signature-based filtering is well known to defend against attacks. By using signature-based filtering, intrusion prevention system passing a payload of packets is compared with attack patterns which are signature. If match, the packet is discard. However, when there is packet delay, it will increase the required pattern matching time as the number of signature is increasing whenever there is delay occur. Therefore, to ensure the performance of IPS, we needed more efficient pattern matching algorithm for high-performance ISP. To improve the performance of pattern matching the most important part is to reduce the number of comparisons signature rules and the packet whenever the packets arrive. In this paper, we propose an improve signature hashing-based pattern matching method. We use tuple pruning algorithm with Bloom filters, which effectively remove unnecessary tuples. Unlike other existing signature hashing-based IPS, our proposed method to improve the performance of IPS.

  • PDF

Fabrication of Multilayer Piezoelectric Actuator with AgPd Internal Electrode (AgPd 내부전극을 이용한 적층형 압전 액츄에이터의 제조)

  • 임인호;윤현상;박종주;백동수;박창엽
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2000
  • In this study, multilayer piezoelectric actuators were fabricated with 75 layers by a conventional multi-layer capacitor (MLC) techniques, using 70Ag/30Pd paste as an internal electrode which can be sintered at low temperature and have cost down effect in mass productions. The multilayer piezoelectric actua-tors had no defects such as diffusions of internal electrode to ceramic bodies and shortages of internal electrodes. The multilayer piezoelectric actuators did not show the crack in the ceramics parts and the gapping phenomena in the external eletrodes when Ag paste was used as external electrodes. The multilayer piezoelectric actuators showed a maximum displacement of 4${\mu}{\textrm}{m}$ at 100V dc voltage and kept the maximum displacement constant for 300 seconds. The multilayer piezoelectric actuators showed good matching properties between ceramic bodies and AgPd internal electrodes. We confirmed the possibility of large-scaled production of the multilayer piezoelectric actuators with superior electrical properties and cost down effect using 70Ag/30Pd paste as an internal electrodes.

  • PDF

A 2.65 GHz Doherty Power Amplifier Using Internally-Matched GaN-HEMT (내부정합된 GaN-HEMT를 이용한 2.65 GHz Doherty 전력증폭기)

  • Kang, Hyunuk;Lee, Hwiseob;Lim, Wonseob;Kim, Minseok;Lee, Hyoungjun;Yoon, Jeongsang;Lee, Dongwoo;Yang, Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.269-276
    • /
    • 2016
  • This paper presents a 2.65 GHz Doherty power amplifier with internally-matched GaN HEMT. Internal matching circuits were adopted to match its harmonic impedances inside the package. Simultaneously, due to the partially matched fundamental impedance, input and output matching networks become simpler. Bond wires and parasitic elements of transistor package were predicted by EM simulation. For the LTE signal with 6.5 dB PAPR, the implemented Doherty power amplifier shows a power gain of 13.0 dB, a saturated output power of 55.4 dBm, an efficiency of 49.1 %, and ACLR of -26.3 dBc at 2.65 GHz with an operating voltage of 48 V.

Comparison and Analysis of Several Main Components between Hot Water Extract and Alcohol Extract of Gamichungsangbohatang (가미청상보하탕(加味淸上補下湯) 열수추출물(熱水抽出物)과 알코올추출물(抽出物)의 지표물질(指標物質) 및 패턴의 비교분석(比較分析))

  • Min, Jung-Ki;Jung, Hee-Jae;Rhee, Hyung-Koo;Jung, Sung-Ki
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.1
    • /
    • pp.55-71
    • /
    • 2006
  • Objectives : To find out more pharmacologically efficient way of extraction of herbal dicoction, Gamichungsangbohatang (GMCSBHT). Methods : Several main components of GMCSBHT was compared and analysed between hot water extract of GMCSBHT and Alcohol(70% ethanol) extract of GMCSBHT via HPLC method. Results : Hot water extract of GMCSBHT showed relatively more component content than ethanol extract of GMCSBHT. Also weighted mean of main components of hot water extraction of GMCSBHT was higher than that of alcohol extract of GMCSBHT. But from chromatographic pattern analysis of matching ratio and similarity ratio showed that these two forms of extracts might have different chemical composition, and 3D PDA plot of alcohol extract of GMCSBHT showed high peaks near UV $190{\sim}220nm$ which was invisible in hot water extract of GMCSBHT. Conclusion : Alcohol extract of GMCSBHT may have some special components which do not exist in hot water extract of GMCSBHT.

  • PDF

Concurrent Validity and Clinical Usefulness of Universal Plastic Goniometer for Hip Internal and External Rotation Range Measurement (고관절 내외회전 가동범위 검사에 대한 범용플라스틱 측각기의 동시타당도와 임상적 유용성)

  • Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.1
    • /
    • pp.99-105
    • /
    • 2018
  • PURPOSE: The aim of this study was to evaluate the concurrent validity and clinical usefulness of the universal plastic goniometer to measure the range of motion of the internal and external rotation of the hip joint using the three dimensional motion analysis which can analyze the joints and segment movements in the most objective and quantitative method. METHODS: Clinical and kinematic data were collected from thirty individuals using a universal plastic goniometer and a ten camera motion analysis system. Passive hip rotation range was obtained three trials for left and right hip joints using two measure methods simultaneously. RESULTS: There were significant differences between all matching measures of the two measures of internal and external rotation of the hip joint (p<.05). The relationship between the two tests for all measurements of the internal and external rotation of the hip was statistically significant with correlation coefficient form r=.87 to .96. (p<.01). CONCLUSION: Clinical measurement of the internal and external rotation of the hip using a universal plastic goniometer is effective to assess the hip condition. However, application of universal plastic goniometer requires careful attention in more accurate evaluation and research verification of the internal and external rotation of hip joint.