• Title/Summary/Keyword: Internal Loss Analysis

Search Result 358, Processing Time 0.021 seconds

Study on Flow Deflection of Duct and Raw Coal Separation Screen (덕트 및 원탄 선별망 유동 편향에 관한 연구)

  • Semyeong Lim;Hyunbum Park
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.4
    • /
    • pp.28-33
    • /
    • 2023
  • In this study, computational fluid dynamics was used to analyze the flow bias generated as air supplied by a fan passes through ducts, piping, and a coal separation screen. The flow bias of the air flow is mostly caused by the spatial characteristics of the fan volute and duct, and the internal baffle and the coal separation screen at the outlet cause strong pressure losses that dampen the flow bias. ANSYS CFX was used for computational fluid dynamics, and since the baffle and the coal separation screen are shaped like perforated plates with many small holes uniformly distributed, actual modeling for analysis was not possible. Therefore, the Porous Loss Model was applied. The evaluation of the flow bias was analyzed based on the velocity distribution of the Porous Loss Model at the outlet surface of the coal separation screen obtained from the computational fluid dynamics results.

A Equivalent Finite Element Model of Lamination for Design of Electromagnetic Engine Valve Actuator

  • Kim, Jin-Ho
    • Journal of Magnetics
    • /
    • v.11 no.4
    • /
    • pp.151-155
    • /
    • 2006
  • The electromagnetic engine valve actuator is a key technology to achieve variable valve timing in internal combustion engine and the steel core and clapper of the electromagnetic engine valve actuator are laminated to reduce the eddy current loss. To design and characterize the performance of the electromagnetic engine valve actuator, FE (finite element) analysis is the most effective way, but FE (finite element) 3-D modeling of real lamination needs very fine meshes resulting in countless meshes for modeling and numerous computations. In this paper, the equivalent FE 2-D model of electromagnetic engine valve actuator is introduced and FE analysis is performed using the equivalent FE 2-D model.

Analysis and Design of Wideband Rotman Lens with Exponential Taper Using Contour Integral and Segmentation Method (경계적분법과 세그멘테이션 기법을 이용한 광대역 지수함수 테이퍼 로트만렌즈의 해석 및 설계)

  • 이광일;이일규;오승엽
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.629-632
    • /
    • 2003
  • This paper has been studied analysis and design of microstrip Rotman lens operating over wide band and wide steering angle by the contour integral method along with the segmentation method. All mutual coupling, internal reflections between ports with exponential taper are taken into account. Equally spaced ports are designed and realized which gives less amplitude ripple at array ports. The measured results of 12 input and 12 output lens show $\pm$1.8 dB insertion loss deviation over 6~18GHz wide frequency range and beam steering accuracy less than 1$^{\circ}$ over $\pm$53$^{\circ}$ angle and agrees well with the analysis results.

  • PDF

Vibration Power Flow Analysis of Coupled Co-planar Orthotropic Plates (동일 평면상에서 연성된 직교이방성 평판의 진동파워흐름해석)

  • Song, Jee-Hun;Park, Do-Hyun;Hong, Suk-Yoon;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.856-862
    • /
    • 2010
  • In this paper, the power flow analysis(PFA) method was developed to predict the vibrational responses of coupled co-planar orthotropic plates in frequencies ranging from medium to high. To cover the power transmission and reflection at the joint of the orthotropic plates, the wave transmission approach is applied with the assumption that all the incident waves are normal to the joint. Through numerical analyses, the power flow energy density and intensity fields of coupled co-planar orthotropic plates were compared with those of classical modal solutions by changing the frequency and internal loss factor, and they show good agreement in terms of the global decay and the attenuation patterns of the energy density.

Review Criteria for Reliability from Analysis of LOOP frequency in NPPs (소외전원상실사고 빈도수 분석을 통한 원전 신뢰도 검토기준)

  • Moon, Su-Cheol;Kim, Kern-Joong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.300-305
    • /
    • 2013
  • LOOP(Loss of Offsite Power) and SBO(Station Blackout) events have been occurring in nuclear power plants should be reviewed and be controlled on important electrical equipments by professional engineer to prevent and to safety improvement from safety assessment and reliability analysis report. LOOP and SBO occasionally happened by internal or external causes. This paper contained that LOOP frequency in the United States NPPs and in the domestic NPPs have compared and analyzed data by the past lessons and probabilistic statistics. Additionally will be installed MG(Mobile Generator) according to the lessons of Fukushima nuclear accident in Japan, which CDF(Core Damage Frequency) and LOOP frequency have reconsidered. And this paper proposed to reduce reliability criteria using PSA(Probabilistic Safety Analysis).

Cecocolic Intussusception Caused by Ancylostoma caninum Infection in a Dog

  • Ko, Hui-Yeon;Kim, Joonyoung;Geum, Migyeong;Suh, Guk-Hyun;Shin, SungShik;Kim, Ha-Jung
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.106-108
    • /
    • 2020
  • An eight-month-old, outdoor, intact male English Pointer dog weighing 23.5 kg presented to the hospital with signs of hematochezia, soft stools, and weight-loss. There were no remarkable findings on physical examination, complete blood count, serum biochemistry, electrolyte and gas analysis, and radiography. The serologic and Polymerase Chain Reaction (PCR) tests for canine parvovirus were negative. A fecal smear examination showed rod-shaped, sporeforming bacteria. Additionally, a fecal flotation test showed ova of Ancylostoma spp. The size of ova was 60 × 40 ㎛, and it was identified as Ancylostoma caninum using light microscopy. The PCR test indicated a Clostridial perfringens infection and the presence of C. perfringens alpha toxin. The diagnosis given was C. perfringens enterotoxicosis with ancylostomiasis. Treatment included antibiotics (metronidazole, trimethoprim-sulfamethoxazole) and anthelmintics (afoxolaner, milbemycin oxime). After two weeks, the clostridial infection resolved, but ancylostomiasis persisted for six weeks. The anthelmintic was changed to Drontalâ plus (praziquantel/pyrantel pamoate/febantel). After four weeks, there were no remarkable findings in the fecal samples, but the patient still presented with watery stools and hematochezia. Survey of abdominal ultrasound had performed, and a target-like sign with multiple rings was seen in the cecocolic region. The patient was diagnosed with A. caninum-induced cecocolic intussusception from the history and clinical signs. After a surgery, he recovered fully. This is the first clinical case report of Ancylostoma caninum parasitizing from the small intestine and causing an intussusception in the large intestine.

A Study on the Repairs of School Uniforms according to Adolescents' Expressive Desires (청소년들의 표현 욕구에 따른 교복수선 행태조사)

  • Choe, Ok-Hui;Jung, Ok-Im
    • Journal of the Korean Home Economics Association
    • /
    • v.47 no.9
    • /
    • pp.15-26
    • /
    • 2009
  • The main purpose of this study was to speculate how psychological state of adolescent students has changed their school uniform style. For the study, the distinctive characteristics during adolescence stage were theoretically examined. Through the examination, this study found four interests in fashions and school uniforms. For the purpose, this study conducted interviews with grade 2 students in a total of six coeducation secondary schools in Seoul, Gyeongki and Gwangju using a questionnaire. The survey period ranged from December 15 2008 to December 24 2008 and a total of 1196 were used for a final analysis. This study extracted factors as Principal Components Analysis and used Varimax for orthogonal rotation analysis. To measure confidence, it used Cronbach's a test to item internal consistency. For data analysis, it used SPSS WIN 12.0 and for hypothesis analysis, frequency analysis, cross analysis, independent t-test, and one-way ANOVA were conducted. For posterior analysis, it used Sheffe test. The results are as follows: First, the interests in fashion and school uniforms differed depending on their own tastes, but these interests were more influenced by environment around school. Secondly, the boy subjects were more aggressive towards repairs their uniforms than the girls, which suggested that boys had stronger desire to show themselves to others and more satisfaction from repairs their uniforms than the girls. Based on the results, this study concluded as follows: We should pay attention to preventing deformation in original design of school uniforms while expanding options to have variable designs or to change detailed part of design. So, there will be no additional uniform mending expense and financial loss to parents, and students will be more satisfied with their school uniforms.

Spinal Epidural Lipomatosis Secondary to Hypothyroidism in a Siberian Husky Dog

  • Jeong, Ju-Young;Hwang, Tae-Sung;Song, Kun-Ho;Song, Joong-Hyun
    • Journal of Veterinary Clinics
    • /
    • v.39 no.5
    • /
    • pp.235-239
    • /
    • 2022
  • A 10-year-old neutered male Siberian Husky presented with paraparesis and severe lethargy. On physical examination, the patient was unable to weight-bear and walk and exhibited significant muscle mass loss in both hindlimbs and generalized truncal alopecia with a dull coat of hair. On neurological examination, cranial lumbar vertebral pain, hind limb cross-extensor reflex, delayed hindlimb postural reaction, upper motor neuron bladder dysfunction, and total absence of cutaneous trunci reflex were identified. Computed tomography revealed diffuse idiopathic skeletal hyperostosis and spondylosis deformans of the cervical and thoracolumbar vertebrae. In addition, a generalized decrease in bone mineral density of the vertebrae was identified. Magnetic resonance imaging showed hyperplasia of the epidural fat compressing the spinal cord in the thoracolumbar region and concurrent mild multiple intervertebral disc herniations. No specific findings were observed in cerebrospinal fluid analysis. Blood analysis of thyroid function revealed decreased total T4 and free T4 levels, and increased TSH levels. The patient was tentatively diagnosed with spinal epidural lipomatosis (SEL) secondary to hypothyroidism. The patient was treated with levothyroxine, firocoxib, and gabapentin. Clinical signs gradually improved, and the patient showed normal ambulation 40 days after treatment initiation. SEL is extremely rare in dogs. To the best of our knowledge, this is the first case report of SEL secondary to hypothyroidism that was treated conservatively. Secondary SEL can be sufficiently managed by treating the underlying cause, if possible.

Complication incidence of two implant systems up to six years: a comparison between internal and external connection implants

  • Chae, Sung-Wook;Kim, Young-Sung;Lee, Yong-Moo;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Su-Hwan
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). Methods: The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. Results: A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Conclusions: Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.

A Study on Steady State Characteristics of LLC Resonant Half Bridge Converter Considering Internal Losses (내부 손실이 고려된 LLC 공진형 하프브릿지 컨버터의 정상상태 특성에 관한 연구)

  • Ahn, Tae-Young
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.985-991
    • /
    • 2018
  • In this paper, an equivalent circuit reflecting the internal loss of the LLC resonant half bridge converter was proposed and a steady state characteristic equation including the loss factors was derived. Using the results, the frequency characteristics of I/O voltage gain and input impedance were compared with the lossless model In order to verify the proposed model and the derived equation, the main components of the 1kW class LLC resonant half bridge converter were selected under the same conditions and the steady state characteristics such as voltage gain and input impedance were compared. In particular, to compare more closely the steady state error of the two models, we observed the change in switching frequency with respect to the load current, which is considered to be the most important in the actual circuit design stage. As a result, it is confirmed that the error of the operating frequency is significantly improved from the proposed model and the analysis result.