• 제목/요약/키워드: Internal Loading

검색결과 620건 처리시간 0.039초

An investigation of torsionally irregular multi-story buildings under earthquake loading

  • Ozmen, G.;Gulay, F.G.
    • Structural Engineering and Mechanics
    • /
    • 제14권2호
    • /
    • pp.237-243
    • /
    • 2002
  • It is well known that torsionally unbalanced buildings are more vulnerable to earthquake hazards than are the regular structural systems. In this paper, a parametric investigation is presented, in order to observe the amplification in the internal forces, when increased eccentricities are used instead of the ones corresponding to the 5% accidental eccentricity. A series of five, ten-story framed and walled structures, with rather high torsional irregularity coefficients, are selected and a numerical test procedure is applied. Numerical results show that the maximum amplification in the internal forces at the most critical beams and columns at the flexible sides of the structures is about 10%. It is concluded that, more serious measures in the codes are needed in the case of this rather dangerous type of irregularity.

국부좌굴을 동반하는 원형강관 부재의 복원력 특성 (The Analysis of Local Buckling Behavior for Steel Circular Tubes)

  • 이상주;이동우;한상을
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2006년도 춘계 학술발표회 논문집 제3권1호(통권3호)
    • /
    • pp.73-80
    • /
    • 2006
  • In this paper, we work with steel circular tubes and propose analysis model which can consider local buckling that it has an effect on failure of steel structures and induce the relation between loading and deformation. First of all, in respect to axial symmetry local buckling, which is simplest case, elasto-plastic behavior acting only axial loads is object. Therefore, it suggests analysis model for axial symmetry local buckling. And that is explainable the process from increasing internal force to decreasing passing maximum internal force. Besides, we induce the relation between the axial force and axial deformation.

  • PDF

내부 환보강 T형 관이음부의 정적강도 (Static Strength of Internally Ring-Stiffened Tubular T-Joints)

  • 조현만;류연선
    • 한국해양공학회지
    • /
    • 제18권6호
    • /
    • pp.70-78
    • /
    • 2004
  • In order to increase the load carrying capacity of tubular structures, the joints of tubular members are usually reinforced with various reinforcement system. A stiffening method with internal ring stiffeners is effectively used for the steel tubular joint with a large diameter. In this study, the behavior of internally ring-stiffened tubular T-joints subjected to axial loading is assessed. For the parametric study, nonlinear finite element analyses are used to compute the static strength on non-stiffened and ring-stiffened T-joints. Based on the numerical results, an internal ring stiffener is found to be efficient in improving the static strength. The influence of geometric parameters has been determined, and the reinforcement effect are evaluated. Based on the FE results, regression analises are performed considering the practical size of ring stiffener. Finally strength estimation formulas for ring-stiffened tubular T-joints are proposed.

Investigation on circular and octagonal concrete-filled double skinned steel tubular short columns under axial compression

  • R, Manigandan;Kumar, Manoj;Shedge, Hrishikesh N.
    • Steel and Composite Structures
    • /
    • 제44권1호
    • /
    • pp.141-154
    • /
    • 2022
  • This paper describes the experimental and numerical investigation on circular and octagonal CFDST short columns under concentric loading to study their responses to various internal circular steel tube sizes by the constant cross-sectional dimensions of the external circular and octagonal steel tube. The non-linear finite element analysis of circular and octagonal CFDST columns was executed using the ABAQUS to forecast and compare the axial behavior influenced by the various sizes of internal circular steel tubes. The study shows that the axial compressive strength and ductility of circular and octagonal CFDST columns were significantly influenced by inner steel tubes with the strengths of constituent materials.

Process of explosive compaction of internally oxidized powders; Cu-0.15%BeO

  • Moon, J.G.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.447-451
    • /
    • 2002
  • The explosive compaction for processing of electrode material was realized based on axisymmetric loading scheme. The compression of internally oxidized fraction of the alloy Cu-0.15%BeO alloy did not provide a considerable strengthening effect; average microhardness varied from 130 to l50Mpa. The tensile strength comes to 30Mpa. However this method can be applicable to obtain a dense briquette for further extrusion of electrode.

  • PDF

강섬유보강 콘크리트의 지압강도에 관한 연구 (A Study on the Bearing Strength of Steel Fiber Reinforced Concrete)

  • 차희석;조환성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.111-114
    • /
    • 1999
  • SFRC(Steel Fiber Reinforced Concrete) has advantage of crack resistance and ductility failure behavior. But the study which investigated about effect of steel fiber under bearing stress is not to be enough, and it does not be sure of criterion of SFRC for allowable bearing stress formula in internal specification. The purpose of this study is to clear the influence of SFRC on the bearing capacity and ductility of material through static loading test. additionally, arrive an allowable bearing stress formula for SFRC and examine mechanical behaviro by the 3-D finite element analysis.

  • PDF

음향방출을 이용한 콘크리트 부재의 미시적 파괴특성의 On-Line Monitoring (On-Line Monitoring of Microscopic Fracture Behavior of Concrete Using Acoustic Emission)

  • 이준현;이진경;장일영;윤동진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.677-682
    • /
    • 1998
  • Concrete is an inhomogeneous material consisting of larger aggregates and sand embedded in a cement paste matrix. In this study, an acoustic emission technique has been used to clarify the microscope failure mechanisms of concrete under three point bending test. AE source location has also been done to monitor the activities of internal damage and the progress of microscopic failure path during the loading. The relationship between AE characteristic and microscopic and microscopic failure mechanism is discussed.

  • PDF

여유구동을 지닌 5절 기구형 손 메카니즘의 성능해석 및 제어 알고리즘 (Analysis and control algorithms for 5-bar finger mechanism with redundant actuators)

  • 이병주;서일홍;오상록
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.48-51
    • /
    • 1996
  • A 5-bar structure with redundant actuators is proposed as a finger mechanism. It is shown that one additional redundant actuator greatly enhances the load handling capacity of the system. The actuator location should be carefully decided to maximize the performance enhancement. Furthermore, we develop stiffness and frequency control algorithms based on the internal loading created by redundant actuation. The effectiveness of these algorithms have been demonstrated by simulations.

  • PDF

원심압축기 내부유동의 점성 3차원 해석 (Computational Analysis of 3-Dimensional Viscous Flow within Centrifugal Compressors)

  • 박무룡;최범석;윤의수
    • 연구논문집
    • /
    • 통권24호
    • /
    • pp.107-117
    • /
    • 1994
  • In aerodynamic design of centrifugal compressors, impellers are designed through preliminary design and blade profile generation. In order to find out faults of the initially designed impellers, the detailed informations about internal flow phenomena such as pressure distribution, flow separation, blade loading, etc are essential. These informations can be acquired with flow measurements or computational flow analyses. In this study, we calculated 3-D viscous flow in 4 back-swept impellers which were designed in our laboratory, and analyzed the flow characteristics which influence the performance of impellers.

  • PDF

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;하수경
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.