우드칩 바이오매스를 이용한 열병합발전 운영 사례 분석 (Case Study and Evaluation of Economic Feasibility of Combined Heat and Power System using Woodchip Biomass)

  • 서길영;김성현
    • 신재생에너지
    • /
    • 제8권4호
    • /
    • pp.21-29
    • /
    • 2012
  • The extensible supply of New & Renewable energy resources desperately needs to counter the high dependence on imported energy, recent high oil prices and the Climate Change Conference, and the government has operated the 'Renewable Portfolio Standard' (RPS) as one of the renewable energy policy from 2012. By analyzing the operation case of combined heat and power plant using the woodchip biomass, we drew the price of wood chip fuel, plant capacity factor, electricity selling price, heat selling price and LCOE value. After analyzing the economic feasibility of 3MWe combined heat and power plant based on the operating performance, the minimum of economic feasibility has appeared to be secured according to the internal rate of return (IRR) is 6.34% and the net present value (NPV) is 3.6 billion won as of 20 years life time after installation, and after analyzing the cases of the economic feasibility of the price of wood chip, plant capacity factor, electricity and heat selling price are changed, the economic feasibility is valuable when the price of wood chip is over 64,000 won/ton, NPV is minus, and the capacity factor is above 46.9%, the electricity selling price is 116 won/kWh and the heat selling price is above 75,600 won/Gcal. When going over the new installation hereafter, we need the detailed review of the woodchip storage and woodchip feeding system rather than the steam-turbine and boiler which have been inspected many times, the reason why is it's hard to secure the suitable quality (constant size) of woodchip by the lack of understanding about it as a fuel because of the domestic poor condition and the calorific value of woodchip is seriously volatile compared with other fuels.

Numerical investigation on ballooning and rupture of a Zircaloy tube subjected to high internal pressure and film boiling conditions

  • Van Toan Nguyen;Hyochan Kim;Byoung Jae Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2454-2465
    • /
    • 2023
  • Film boiling may lead to burnout of the heating element. Even though burnout does not occur, the heating element is subject to deformation because it is not sufficiently strong to withstand external loads. In particular, the ballooning and rupture of a tube under film boiling are important phenomena in the field of nuclear reactor safety. If the tube-type cladding of nuclear fuel ruptures owing to high internal pressure and thermal load, radioactive materials inside the cladding are released to the coolant. Therefore, predicting the ballooning and rupture is important. This study presents numerical simulations to predict the ballooning behavior and rupture time of a horizontal tube at high internal pressure under saturated film boiling. To do so, a multi-step coupled simulation of conjugated film boiling heat transfer and ballooning using creep model is adopted. The numerical methods and models are validated against experimental values. Two different nonuniform heat flux distributions and four different internal pressures are considered. The three-step simulation is enough to obtain a convergent result. However, the single-step simulation also successfully predicts the rupture time. This is because the film boiling heat transfer characteristics are slightly affected by the tube geometry related to creep ballooning.

난방운전 조건하에서 $CO_2$ 열펌프용 내부 열교환기의 열전달 특성에 대한 연구 (Study on Heat Transfer Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Heating Operating Condition)

  • 김대훈;이상재;최준영;이재헌;권영철
    • 에너지공학
    • /
    • 제17권2호
    • /
    • pp.116-123
    • /
    • 2008
  • 본 연구에서는 $CO_2$ 열펌프에 사용되는 내부 열교환기를 난방조건에서 운전할 경우, 실험 및 수치적 방법으로 열전달량, 효율, 압력강하 등을 관찰하였다. 4가지 종류의 내부 열교환기를 사용하였다. 수치 해석은 단면분할법과 하디크로스 방법을 이용하여 유량, 길이, 운전조건, 내부 열교환기 종류에 따른 영향을 분석하고 실험을 통해 확인하였다. 유량이 증가함에 따라 열전달량이 약 25% 향상되었다. 마이크로 채널이 동심관에 비해 열전달량이 약 100% 크게 나타났다. 길이가 증가함에 따라 열전달 증가율은 감소하였다. 압력강하는 고압측에 비해 저압측이 크게 나타났으며, 동심관에 비해 마이크로 채널이 약 100% 크게 나타났다. 고온입구조건이 증가할수록, 저온입구조건이 감소할수록 열전달량은 약 3% 증가하였다. $CO_2$의 열전달 계산의 정확성을 위해 $CO_2$의 특성과 관형상을 고려할 수 있는 열전달 상관식의 개발이 필요하다.

동적하중을 받는 궤도차량 고무패드의 정상 열전도 해석 (Analysis of Steady Heat Conduction for Rubber Pads of a Tank Track Subjected to Dynamic Loading)

  • 김형제;김병탁
    • Elastomers and Composites
    • /
    • 제36권3호
    • /
    • pp.153-161
    • /
    • 2001
  • 궤도차량의 고무패드는 상당한 크기의 진폭과 주파수를 가지고 반복되는 동적 변형을 받고 있으므로, 이로 인하여 열발생과 더불어 상당한 내부온도의 상승을 초래한다. 이러한 열발생은 고무 재료의 점탄성 특성에 기인한 것으로, 점성효과에 의하여 변형시의 기계적 에너지의 일부가 히스테리시스 루프의 면적에 해당되는 열에너지로 변환되기 때문이다. 발생한 열은 발산조건이 충분하지 못할 경우 내부온도의 상승을 초래하며, 온도가 과다할 경우에는 고무제품의 성능이나 수명에 중대한 장애요인으로 작용하게 된다. 본 연구에서는 전차 궤도고무에 작용하는 동적 하중에 근거하여 각 부품별 열발생률을 실험을 통하여 측정하고, 이를 입력자료로 하여 궤도패드에 발생하는 온도분포를 유한요소법으로 해석하였다.

  • PDF

1-D Mean Line Flow Model을 이용한 엔진 배기에너지 회수를 위한 터보컴파운드 시스템용 터빈 설계 (Turbine Design for Turbo-compound System to Recover Exhaust Gas Energy Using 1-D Mean Line Flow Model)

  • 장진영;윤정의
    • 한국자동차공학회논문집
    • /
    • 제24권1호
    • /
    • pp.74-81
    • /
    • 2016
  • The aim of this study was to find the initial design value of turbine blade for electrical type turbocompound system generating 10 kW. Turbocompound is one of the waste heat recovery system applying to internal combustion engine to recover exhaust gas energy that was about 30 % of total input energy. To design the turbine blade, 1-D mean line flow model was used. Exhaust gas temperature, pressure, flow rate and turbine rotating speed was fixed as primary boundary conditions. The velocity triangles was defined and used to determine the rotor inlet radius and width, the rotor outlet radius at shroud and radius at hub, the rotor flow angles and the number of blades.

고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구 (Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings)

  • 조진균;정차수;김병선
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

고온냉매 우회방법을 적용한 열펌프의 성능 개선 연구 (A Study on Performance Improvement of Heat Pump Adopting the Hot Gas Bypass Method)

  • 강신형;변주석
    • 에너지공학
    • /
    • 제15권4호
    • /
    • pp.235-242
    • /
    • 2006
  • 본 연구는 공기 열원 열펌프의 성능 향상을 위한 연구로써 제상 방법으로 고온냉매 우회방법을 사용하고 내부열교환기를 장착한 열펌프 시스템의 성능을 ISO5151의 표준제상 조건에서 실험하였다. 실험은 고온냉매 우회방법과 가장 일반적인 제상 방법인 시간주기 제상방법을 비교하였으며 착상 발생 후 압축기 출구의 고온냉매를 실외기 입구로 우회시킬 때 실외기 홴 속도를 정상속도에 대하여 0%, 30%, 60%, 90%로 변화 시키면서 열펌프의 성능변화를 관찰하였다. 연구결과 210분의 열펌프 가동시간 동안 고온냉매 우회방법은 시간주기 제상방법 보다 $2.2{\sim}6%$ 높은 평균 성능계수를 나타냈으며 고온냉매 우회방법에서는 실외기의 홴 속도가 60%일 때 가장 좋은 성능계수와 난방용량을 나타냈다.

구동조건에 따른 전자레인지 내부 온도 분포 (Temperature Distributions of Inner Microwave for Various Working Conditions)

  • 최윤환;김동균
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.792-797
    • /
    • 2010
  • 가정용 조리기구인 전자레인지는 구동시 필요한 고주파의 형성을 위하여 고전압 발생장치와 고 전압 축전지 등의 장치가 사용된다. 이 장치들은 높은 전압에서 구동되기 때문에 다량의 열에너지를 방출한다. 따라서 방출된 열에너지는 전자레인지 본체의 온도를 상승시키는 요인이 된다. 본 연구에서는 쿨링팬 구동조건과 열에너지 발생조건에 따른 전자레인지 내부의 온도 분포를 해석하였다. 해석결과 쿨링팬에서 유출되는 공기의 속도가 증가함에 따라 내부 온도가 감소하는 것을 확인하였으며 감소하는 정도를 정량적으로 분석하였다. 그리고 열에너지 방출량을 조정하여 내부 온도분포를 조사하였다.

온도에 따른 고분자전해질막의 기계적 특성에 관한 연구 (A Study on the Mechanical Properties of Polymer Electrolyte Membrane according to Temperature)

  • 어준우;김승환;서영진;고형종;황철민;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.566-573
    • /
    • 2022
  • In this study, the mechanical properties of the polymer electrolyte membrane according to the temperature were studied. The test specimens of polymer electrolyte membrane were heat treated at 40℃, 60℃, 80℃, 100℃, and 120℃, and then the tensile tests were performed. As results of this study, the residual stress of the polymer electrolyte membrane was removes by the heat treatment and the elastic modulus decreased due to the decrease in internal energy. In addition, in the plastic region, the mechanical properties and crystallization rate of the polymer electrolyte membrane increased in proportion according to increase of the heat treatment temperature.

Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구 (A Study on Heat Transfer Coefficient of a Perfluorocarbon Heat Pipe)

  • 강환국;김철주;김재진
    • 에너지공학
    • /
    • 제7권2호
    • /
    • pp.194-201
    • /
    • 1998
  • 전기 철도 차량의 A.C 모터 속도제어에는 여러 개의 GTO thyristor와 다이오드가 필요하다. 그런데 이러한 반도체 소자들은 약 1~2 kW의 열을 발생하기 때문에 냉각장치가 필요하며 이러한 반도체의 냉각에는 Perfluorocarbon(PFC)을 작동유체로 하는 히트파이프를 많이 사용하고 있다. 본 연구에서는 PFC 히트파이프의 증발 및 응축 열전달 계수에 미치는 관련변수로 주입율, 관의 내부 표면상태, 경사각, 증기압, 열유속 등의 영향을 파악하고, 열전달 계수를 예측할 수 있는 상관식을 제시하고자 하였다. 이를 위해 내부 표면에 그루브가 설치된 동관과 표면이 매끈한 외경 15.88mm인 동관을 이용하여 주입율이 다른 총 길이 520mm의 PFC 히트파이프와 열사이폰을 제작하고 실험을 수행하였다. 증발 열전달 계수는 열유속 15~45 kW/$m^2$의 범위일 때 2 kW/$m^2$K~5.5 kW/$m^2$K 사이의 분포를 보였다. 실험결과는 수정계수 CR=1.3을 적용할 때 Rohsenow의 핵비등 상관식과 실험치가 매우 접근된 결과를 보였으며 이러한 결과는 내부 벽면 그루브의 열전달 촉진효과이다. 응축 열전달 계수의 측정치는 1.5kW/$m^2$K~3.5kW/$m^2$K 사이의 분포를 보였으며 Nusselt 막응축 모델에 수정계수 CN=4를 도입함으로써 매우 접근된 예측이 가능하였다. 증발부 체적에 대한 작동유체 주입율은 40~100%의 범위가 적절하였다. 그리고 30$^{\circ}$이상의 경사각에서는 경사각의 영향이 미소하였다.

  • PDF