• 제목/요약/키워드: Internal Diffusion

검색결과 307건 처리시간 0.03초

Diffusion-Weighted Imaging for Detecting Glufosinate Ammonium Intoxication: A Case Report (글루포시네이트 암모늄 중독 환자의 확산자기공명영상 소견: 증례 보고)

  • Hyoung Yeob Kim;Noh Hyuk Park
    • Journal of the Korean Society of Radiology
    • /
    • 제83권6호
    • /
    • pp.1354-1359
    • /
    • 2022
  • Glufosinate ammonium-containing herbicides are non-selective herbicides, used worldwide. With the increasing use of glufosinate ammonium-containing herbicides, cases of acute intoxication in suicide attempts have also increased. Herein, we report a case of a patient presenting cytotoxic edema in the posterior limbs of the bilateral internal capsules, bilateral middle cerebellar peduncles, and splenium of the corpus callosum on the brain diffusion-weighted MRI after glufosinate ammonium intoxication.

High Temperature Corrosion in Carbon-Rich Gases

  • Young, D.J.
    • Corrosion Science and Technology
    • /
    • 제7권2호
    • /
    • pp.69-76
    • /
    • 2008
  • Common methods for large scale hydrogen production, such as steam reforming and coal gasification, also involve production of carbonaceous gases. It is therefore necessary to handle process gas streams involving various mixtures of hydrocarbons, $H_2$, $H_2O$, CO and $CO_2$ at moderate to high temperatures. These gases pose a variety of corrosion threats to the alloys used in plant construction. Carbon is a particularly aggressive corrodent, leading to carburisation and, at high carbon activities, to metal dusting. The behaviour of commercial heat resisting alloys 602CA and 800, together with that of 304 stainless steel, was studied during thermal cycling in $CO/CO_2$ at $650-750^{\circ}C$, and also in $CO/H_2/H_2O$ at $680^{\circ}C$. Thermal cycling caused repeated scale separation, which accelerated chromium depletion from the alloy subsurface regions. The $CO/H_2/H_2O$ gas, with $a_C=2.9$ and $p(O_2)=5\times10^{-23}$ atm, caused relatively rapid metal dusting, accompanied by some internal carburisation. In contrast, the $CO/CO_2$ gas, with $a_C=7$ and $p(O_2)=10^{-23}-10^{-24}$ atm caused internal precipitation in all three alloys, but no dusting. Inward diffusion of oxygen led to in situ oxidation of internal carbides. The very different reaction morphologies produced by the two gas mixtures are discussed in terms of competing gas-alloy reaction steps.

An NMR Study on Internal Rotation of $CH_3$ Group in 1,1,1-Trichloroethane

  • Hyung Namgoong;Kim, Joa-Jin;Lee, Jo-Woong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • 제4권1호
    • /
    • pp.29-40
    • /
    • 2000
  • Coupled carbon-13 relaxation study of 1,1,1-trichloroethane dissolved in DMSO has been performed to gain some crucial insight into the dynamics of methyl group in this compound. For this purpose the relaxation behaviors of several observable magnetization modes for CH3 spin system generated by various perturbing pulse sequences have been carefully investigated and various dipolar spectral densities were estimated by nonlinear numerical fittings of the observed data with the relaxation curves, which were then employed to determine the three principal values for the diffusion tensor for end-over-end molecular rotation as well as internal rotational parameters of methyl group. In this process we could uniquely determine two correlation times $\tau$int(1) and $\tau$int(2) which give valuable information on internal rotor dynamics and thus obtained data were interpreted on the basis of various proposed models for internal rotation. compound undergoes three-fold jumps at 25$^{\circ}$. The fact that the ratio $\tau$int(1) / $\tau$int(2) is close to 1.0 may be interpreted as indicating that methyl group in this C.

  • PDF

Improvement in LED structure for enhanced light-emission

  • Park, Seong-Ju
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 한국재료학회 2003년도 추계학술발표강연 및 논문개요집
    • /
    • pp.21-21
    • /
    • 2003
  • To increase the light-emission efficiency of LED, we increased the internal and external quantum efficiency by suppressing the defect formation in the quantum well and by increasing the light extraction efficiency in LED, respectively. First, the internal quantum efficiency was improved by investigating the effect of a low temperature (LT) grown p-GaN layer on the In$\sub$0.25/GaN/GaN MQW in green LED. The properties of p-GaN was optimized at a low growth temperature of 900oC. A green LED using the optimized LT p-type GaN clearly showed the elimination of blue-shift which is originated by the MQW damage due to the high temperature growth process. This result was attributed to the suppression of indium inter-diffusion in MQW layer as evidenced by XRD and HR-TEM analysis. Secondly, we improved the light-extraction efficiency of LED. In spite of high internal quantum efficiency of GaN-based LED, the external quantum efficiency is still low due to the total internal reflection of the light at the semiconductor-air interface. To improve the probability of escaping the photons outside from the LED structure, we fabricated nano-sized cavities on a p-GaN surface utilizing Pt self-assembled metal clusters as an etch mask. Electroluminescence measurement showed that the relative optical output power was increased up to 80% compared to that of LED without nano-sized cavities. I-V measurement also showed that the electrical performance was improved. The enhanced LED performance was attributed to the enhancement of light escaping probability and the decrease of resistance due to the increase in contact area.

  • PDF

Influence of Ge addition on phase formation and electromagnetic properties in internal tin processed $Nb_3$Sn wires (내부 확산법에 의한 $Nb_3$Sn초전도선에 Ge 첨가에 따른 임계전류 및 미세조직 변화)

  • 하동우;오상수;이남진;하홍수;권영길;류강식;백홍구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.496-499
    • /
    • 2000
  • In order to investigate the effect of Ge addition to the Cu Matrix on the microstructure and the critical current density, four kinds of internal tin processed Nb$_3$Sn strands with pure Cu and Cu 0.2, 0.4, 0.6 wt% Ge alloy were drawn to 0.8 mm diameter. The microstructure and critical current of internal tin processed Nb$_3$Sn wires that were heat treated at temperatures ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$ for 240 h were investigated. The Ge addition to the matrix did not make workability worse. A Ge rich layer in the Cu-Ge matrix suppressed the growth of the Nb$_3$Sn layer and promoted grain coarsening. The greater the Ge content in the matrix, the lower the net Jc result after Nb$_3$Sn reaction heat treatment. There was no significant variation in Jc observed with heat treatment temperature ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$.

  • PDF

Influences of Electrodeposition Variables on the Internal Stess of Nanocrystalline Ni-W Films (나노결정질 Ni-W 합금전착의 내부응력에 미치는 공정조건 변수의 영향)

  • Kim, Kyung-Tae;Lee, Jung-Ja;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • 제11권6호
    • /
    • pp.275-279
    • /
    • 2012
  • Ni-W alloy deposits have lately attracted the interest as an alternative surface treatment method for hard chromium electrodeposits because of higher wear resistance, hardness at high temperature, and corrosion resistance. This study deals with influences of process variables, such as electodeposition current density, plating temperature and pH, on the internal stress of Ni-W nanocrystalline deposits. The internal stress was increased with increasing the applied current density. With increasing applied current density, the grain size of the deposit decreases and concentration of hydrogen in the deposit increases. The subsequent release of the hydrogen results in shrinkage of the deposit and the introduction of tensile stress in the deposit. Consequently, for layers deposited at high current density, cracking occurs readily owing to high tensile stress value. By increasing the temperature of the electrodeposition from $60^{\circ}C$ to $80^{\circ}C$, the internal stress was decreased. It seems that an increase in the number of active ions overcoming the activation energy at elevated temperature caused a decline in the concentration polarization and surface diffusion. It decreased the level of hydrogen absorption due to the lessened hydrogen evolution reaction. Therefore, the lower level of hydrogen absorption degenerated the hydride on the surface of the electrode, resulting in the reduction of the internal stress of the deposits. By increasing the pH of the electrodeposition from 5.6 to 6.8, the internal stress in the deposits were slightly decreased. It is considered that the decrease in internal stess of deposits was due to supply of W complex compound in cathode surface, and hydrogen ion resulted from decrease of activity.

Development and Validation of a Model Using Radiomics Features from an Apparent Diffusion Coefficient Map to Diagnose Local Tumor Recurrence in Patients Treated for Head and Neck Squamous Cell Carcinoma

  • Minjae Kim;Jeong Hyun Lee;Leehi Joo;Boryeong Jeong;Seonok Kim;Sungwon Ham;Jihye Yun;NamKug Kim;Sae Rom Chung;Young Jun Choi;Jung Hwan Baek;Ji Ye Lee;Ji-hoon Kim
    • Korean Journal of Radiology
    • /
    • 제23권11호
    • /
    • pp.1078-1088
    • /
    • 2022
  • Objective: To develop and validate a model using radiomics features from apparent diffusion coefficient (ADC) map to diagnose local tumor recurrence in head and neck squamous cell carcinoma (HNSCC). Materials and Methods: This retrospective study included 285 patients (mean age ± standard deviation, 62 ± 12 years; 220 male, 77.2%), including 215 for training (n = 161) and internal validation (n = 54) and 70 others for external validation, with newly developed contrast-enhancing lesions at the primary cancer site on the surveillance MRI following definitive treatment of HNSCC between January 2014 and October 2019. Of the 215 and 70 patients, 127 and 34, respectively, had local tumor recurrence. Radiomics models using radiomics scores were created separately for T2-weighted imaging (T2WI), contrast-enhanced T1-weighted imaging (CE-T1WI), and ADC maps using non-zero coefficients from the least absolute shrinkage and selection operator in the training set. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of each radiomics score and known clinical parameter (age, sex, and clinical stage) in the internal and external validation sets. Results: Five radiomics features from T2WI, six from CE-T1WI, and nine from ADC maps were selected and used to develop the respective radiomics models. The area under ROC curve (AUROC) of ADC radiomics score was 0.76 (95% confidence interval [CI], 0.62-0.89) and 0.77 (95% CI, 0.65-0.88) in the internal and external validation sets, respectively. These were significantly higher than the AUROC values of T2WI (0.53 [95% CI, 0.40-0.67], p = 0.006), CE-T1WI (0.53 [95% CI, 0.40-0.67], p = 0.012), and clinical parameters (0.53 [95% CI, 0.39-0.67], p = 0.021) in the external validation set. Conclusion: The radiomics model using ADC maps exhibited higher diagnostic performance than those of the radiomics models using T2WI or CE-T1WI and clinical parameters in the diagnosis of local tumor recurrence in HNSCC following definitive treatment.

A Study on Technological Forecasting of Next-Generation Display Technology (차세대 디스플레이 기술의 예측에 관한 연구)

  • Nam, Ki-Woong;Park, Sang-Sung;Shin, Young-Geun;Jung, Won-Gyo;Jang, Dong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제10권10호
    • /
    • pp.2923-2934
    • /
    • 2009
  • This paper presents study on technological forecasting of Next-Generation Display technology. Next-Generation Display technology is one of the emerging technologies lately. So databases on patent documents of this technology were analyzed first. And patent analysis was performed for finding out present technology trend. And the forecast for this technology was made by growth curves which were obtained from forecast models using patent documents. In previous study, Gompertz, Logistic, Bass were used for forecasting diffusion of demand in market. Gompertz, Logistic models which were often used for technological forecasting, too. So, two models were applied in this study. But Gompertz, Logistic models only consider internal effect of diffusion. And it is difficult to estimate maximum value of growth in two models. So, Bass model which considers both internal effect and external effect of diffusion was also applied. And maximum value of growth in Gompertz, Logistic models was estimated by Bass model.

Measurement of Apparent Diffusion Coefficient Values from Diffusion-Weighted MRI: A Comparison of Manual and Semiautomatic Segmentation Methods

  • Kim, Seong Ho;Choi, Seung Hong;Yoon, Tae Jin;Kim, Tae Min;Lee, Se-Hoon;Park, Chul-Kee;Kim, Ji-Hoon;Sohn, Chul-Ho;Park, Sung-Hye;Kim, Il Han
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.88-98
    • /
    • 2015
  • Purpose: To compare the interobserver and intraobserver reliability of mean apparent diffusion coefficient (ADC) values using contrast-enhanced (CE) T1 weighted image (WI) and T2WI as structural images between manual and semiautomatic segmentation methods. Materials and Methods: Between January 2011 and May 2013, 28 patients who underwent brain MR with diffusion weighted image (DWI) and were pathologically confirmed as having glioblastoma participated in our study. The ADC values were measured twice in manual and semiautomatic segmentation methods using CE-T1WI and T2WI as structural images to obtain interobserver and intraobserver reliability. Moreover, intraobserver reliabilities of the different segmentation methods were assessed after subgrouping of the patients based on the MR findings. Results: Interobserver and intraobserver reliabilities were high in both manual and semiautomatic segmentation methods on CE-T1WI-based evaluation, while interobserver reliability on T2WI-based evaluation was not high enough to be used in a clinical context. The intraobserver reliability was particularly lower with the T2WI-based semiautomatic segmentation method in the subgroups with involved $lobes{\leq}2$, with partially demarcated tumor borders, poorly demarcated inner margins of the necrotic portion, and with perilesional edema. Conclusion: Both the manual and semiautomatic segmentation methods on CE-T1WI-based evaluation were clinically acceptable in the measurement of mean ADC values with high interobserver and intraobserver reliabilities.

Testicular Epidermoid Cyst on Diffusion-Weighted MR Imaging and ADC Map : A Case Report (확산강조영상과 현상확산계수(ADC) 영상을 통한 고환 표피 낭종의 진단: 증례 보고)

  • Kim, Mi-Sun;Kim, Kyung-Ah;Chang, Sun-Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권2호
    • /
    • pp.154-159
    • /
    • 2011
  • Testicular epidermoid cyst is a rare benign tumor, accounting for 1-2% of all testicular tumors. It can be cured by organ preserving surgery, so accurate preoperative diagnosis is very important for preventing unneccessary and extensive orchiectomy. We experienced a case of an 18-year-old man who presented with a painless lump in his right testis. The testicular mass showed an onion ring sign on ultrasonography. Computed tomography images showed the mass as a low attenuating lesion with curvilinear calcification. On Magnetic resonance imaging (MRI), the mass appeared as high signal intensity with internal alternating low signal intensity patterns on T2-weighted images. The mass was displayed as having homogeneous high signal intensity on diffusion magnetic resonance imaging and showed lower apparent diffusion coefficient values than normal testis parenchyma, similar to intracranial epidermoid cysts. Testicular MRI with DWI and ADC map can help to more accurately diagnose testicular epidermoid cyst.