• Title/Summary/Keyword: Internal Diffusion

Search Result 307, Processing Time 0.025 seconds

Comparison of Harboring the Resistance Gene and Disc Diffusion Susceptibility Test Result in Staphylococcus pseudintermedius from the Bacterial Dermatitis (세균성 피부염 개에서 분리된 Staphylococcus pseudintermedius에서 항생제 감수성 검사와 내성 유전자 획득의 비교)

  • Jang, Hye-Jin;Son, Hyoung-Won;Kang, Hyo-Min;Han, Jae-Ik;Na, Ki-Jeong
    • Journal of Veterinary Clinics
    • /
    • v.32 no.2
    • /
    • pp.158-161
    • /
    • 2015
  • Bacterial dermatitis is common disease that is necessary to treat with antibiotics. In recent, antibiotic-resistant bacteria is being increased in worldwide. The purpose of the present study was to evaluate the prevalence of resistant genes in Staphylococcus (S.) pseudintermedius isolated from dogs, and to compare the resistant gene profile with the result of antibiotic disc diffusion test. A total of seven S. pseudintermedius was included in the study. Bacterial identification was performed by 16S ribosomal RNA gene sequence analysis. S. pseudintermedius isolates had more than one antibiotic resistant gene (mecA, blaZ and aac(6')/aph(2"). While all isolates were PCR positive to blaZ gene, only two isolates were resistant to amoxicillin/clavulanate. Among five isolates harboring gentamicin resistance, one isolate was negative to aac(6')/aph(2")-targeted PCR. Taken together, the results suggest that resistant gene-targeted PCR and disc diffusion test are complementary to detect antibiotic resistance.

Chain Length Effect on the Configurational Properties of an n-Alkane Chain in Solution

  • Jeon, Seung-Ho;Ree, Tai-Kyue;Oh, In-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.5
    • /
    • pp.367-371
    • /
    • 1986
  • Dynamic and equilibrium properties of n-alkane chains immersed in solvent molecules have been investigated by a molecular dynamics method. The n-alkane chain is assumed to be a chain of elements (CH$_2$) interconnected by bonds having a fixed bond length and bond angle, but each bond of the chain is allowed to execute hindered internal rotation. We studied the effect of the number of the chain elements (N$_c$ = 10, 15 and 20) on the equilibrium properties of the system, e.g., the pair correlation functions between a chain element and solvent molecules, g$_{cs}$(r), and between the chain elements, g$_{cc}$(r), and the configurational properties such as the mean-square end-to-end distance < R$^2$ >, the mean-square radius of gyration < S$^2$ >, and the eigenvalues of the moment-of-inertia tensor < S$_i^2$ > / < S$^2$ > (i = 1, 2 and 3). We also studied the dynamic properties of the system, e.g., the autocorrelation function C(A;t) where A = R$^2$(t), = S$^2$(t), or = ${\vec{V}}(t)({\vec{V}}$ = velocity of the center of mass), and the diffusion coefficient D. The g$_{cs}$(r)'s are almost equal irrespective of the change of Nc while g$_{cc}$(r) becomes larger as N$_c$ increases; The MD computed configurational properties < R$^2$2 > and < S$^2$ > were found to be a little different from the values calculated from the statistical equations of < R$^2$ > and < S$^2$ >, it may be due to the fact that our model for the MD simulations includes a long-range volume effect. From the < S$_i^2$ > / < S$^2$ >, it is found that the chain molecule has a nearly spherical shape irrespective of the variation of N$_c$. For the dynamic properties we found that the C(R$^2$;t) and C(S$^2$;t) of lower N$_c$ decay faster than those of higher N$_c$, while the C($\vec V$;t) of the center of mass in the chain is weakly dependent on the N$_c$. The center of mass diffusion coefficient D$_c$ decreases as N$_c$ increases while the end point diffusion coefficient D$_e$ is nearly equal irrespective of the change of N$_c$.

Analysis of Cause of Fire and Explosion in Internal Floating Roof Tank: Focusing on Fire and Explosion Accidents at the OO Oil Pipeline Corporation (내부 부상형 저장탱크(IFRT) 화재·폭발사고 원인 분석: OO송유관공사 저유소 화재·폭발사건을 중심으로)

  • Koo, Chae-Chil;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.86-93
    • /
    • 2020
  • This study aims to maintain the safety of an outdoor storage tank through the fundamental case analysis of explosion and fire accidents in the storage tank. We consider an accident caused by the explosion of fire inside the tank, as a result of the gradual spreading of the residual fire generated by wind lamps flying off a workplace in the storage tank yard. To determine the cause of the accident, atmospheric diffusion conditions were derived through CCTV image analysis, and the wind direction was analyzed using computational fluid dynamics. Additionally, the amount of oil vapor inside the tank when the floating roof was at the lowest position, and the behavior of the vapor inside the tank when the floating roof was at the highest position were investigated. If the cause of the explosion in the storage tank is identified and the level of the storage tank is maintained below the internal floating roof, dangerous liquid fills the storage tank, and the vapor in the space may stagnate on the internal floating roof. We intend to improve the operation procedure such that the level of the storage tank is not under the Pontoon support, as well as provide measures to prevent flames from entering the storage tank by installing a flame arrester in the open vent of the tank.

Optimization of the growth of $CaF_2$ crystals by model experiments and numerical simulation

  • Molchanov, A.;Graebner, O.;Wehrhan, G.;Friedrich, J.;Mueller, G.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.1
    • /
    • pp.15-18
    • /
    • 2003
  • High purity single crystalline calcium fluoride ($CaF_2$) has excellent optical transmission characteristics down to deep UV and is therefore selected as the main optical material for the next generation of lithography apparatus operating at wavelength of 157 nm. The growth of large sized $CaF_2$ single crystals with the required properties for this optical application can be achieved only by optimizing the crystal growth process by the aid of numerical simulation. This needs especially a precise calculation of the heat transport and temperature distribution in the solid and liquid $CaF_2$ under crystal growth conditions. As $CaF_2$ is considered to be semitransparent, the internal radiative heat transfer in $CaF_2$ plays an decisive role in the simulation of the heat transport. On the other hand it is very difficult to obtain quantitative experimental data for evaluating numerical models as $CaF_2$ is extremely corrosive at high temperatures. In this work we present a newly developed experimental technique to perform temperature measurements in $CaF_2$-crystal as well as in the melt under conditions of crystal growth process. These experimental results are compared to calculated temperature data, which were obtained by using different numerical models concerning the internal heat transfer in semitransparent $CaF_2$. It will be shown, that an advanced model, which was developed by the authors, gives a much better agreement with experimental data as a standard model, which was taken from the literature.

Yersinia enterocolitica isolation from three adult enteritis patients (성인 장염 환자에서의 Yersinia enterocolitica 분리 3예)

  • Chong, Yun-Sop;Lee, Hee-Joo;Lee, Sam-Uel Y.;Kang, Jin-Kyung;Moon, Young-Myuong
    • The Journal of the Korean Society for Microbiology
    • /
    • v.15 no.1
    • /
    • pp.3-8
    • /
    • 1980
  • Yersinia enterocolitica has been known to be an important enteric pathogen especially in Scandinavian countries and Canada. In Korea, the authors reported the first case of Y. pseudotuberculosis septicemia in 1979. In 1980, three isolates of Y enterocolitica were obtained from 3 adult patients with enteritis, besides the already reported one in a 5-month-old child, during March to June 1980. Difficulty in the isolation was experienced; ie., the organism was isolated only from the SS primary isolation plate in one case and in the other two cases only from the SS plates inoculated with overnight culture of selenite broth. The isolates showed typical cultural and biochemical characteristics except for the nonmotility even at room temperature. Two isolates were indole negative possibly belonging to Wauter's biotype 3 and the other one was indole positive belonging to biotype 2. One patient was tested for the serum agglutinin titer on the 8th hospital day and it was found to be 1:128. All of the isolates were susceptible to chloramphenicol, colistin, gentamicin, kanamycin, tetracyclne, and tobramycin by the Kirby-Bauer disc diffusion method. All of the infections were controled by ampicillin, amoxicillin, amikacin, or gentamicin treatment. It is considered urgent to broaden our knowledge on yersiniosis in Korea not only by isolating, serotyping and biotyping of the organism, but also by surveying serum agglutinin titer of enteritis patients and normal individuals.

  • PDF

An Analysis of Light Induced Degradation with Optical Source Properties in Boron-Doped P-Type Cz-Si Solar Cells (광원의 특성에 따른 Boron-doped p-type Cz-Si 태양전지의 광열화 현상 분석)

  • Kim, Soo Min;Bae, Soohyun;Kim, Young Do;Park, Sungeun;Kang, Yoonmook;Lee, Haeseok;Kim, Donghwan
    • Korean Journal of Materials Research
    • /
    • v.24 no.6
    • /
    • pp.305-309
    • /
    • 2014
  • When sunlight irradiates a boron-doped p-type solar cell, the formation of BsO2i decreases the power-conversion efficiency in a phenomenon named light-induced degradation (LID). In this study, we used boron-doped p-type Cz-Si solar cells to monitor this degradation process in relation to irradiation wavelength, intensity and duration of the light source, and investigated the reliability of the LID effects, as well. When halogen light irradiated a substrate, the LID rate increased more rapidly than for irradiation with xenon light. For different intensities of halogen light (e.g., 1 SUN and 0.1 SUN), a lower-limit value of LID showed a similar trend in each case; however, the rate reached at the intensity of 0.1 SUN was three times slower than that at 1 SUN. Open-circuit voltage increased with increasing duration of irradiation because the defect-formation rate of LID was slow. Therefore, we suppose that sufficient time is needed to increase LID defects. After a recovery process to restore the initial value, the lower-limit open-circuit voltage exhibited during the re-degradation process showed a trend similar to that in the first degradation process. We suggest that the proportion of the LID in boron-doped p-type Cz-Si solar cells has high correlation with the normalized defect concentrations (NDC) of BsO2i. This can be calculated using the extracted minority-carrier diffusion-length with internal quantum efficiency (IQE) analysis.

High-Temperature Oxidation of Ti Containing Stainless Steel in O2-N2 Atmosphere

  • Onishi, Hidenori;Saeki, Isao;Furuichi, Ryusaburo;Okayama, Toru;Hanamatsu, Kenko;Shibayama, Tamaki;Takahashi, Heishichiro;Kikkawa, Shinichi
    • Corrosion Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.140-147
    • /
    • 2004
  • High temperature oxidation of Fe-19Cr and Fe-19Cr-0.2Ti alloys is studied at 1173-1373 K in 16.5 kPa $O_2$ - balances $N_2$ atmosphere aimed at clarifying the effect of titanium addition. Oxidation rate of Fe-19Cr alloy was accelerated with titanium. For both alloys chromium rich $(Fe,\;Cr)_2O_3$ was formed as a major oxidation product. On Fe-19Cr-0.2Ti alloy, a thin layer composed of spinel type oxide and titanium oxide was also formed and an internal oxidation of titanium was observed. Titanium was concentrated at the oxide surface and internal oxidation zone but a small amount of titanium was also found in the intermediate corundum type $(Fe,\;Cr)_2O_3$ layer. Crystals of corundum type $(Fe,\;Cr)_2O_3$ formed on Fe-19Cr alloy are coarse but that formed on Fe-19Cr -0.2Ti alloys were fine and columnar. Reason for the difference in oxidation kinetics and crystal structure will be discussed relating to the distribution of aliovalent titanium in corundum type $(Fe,\;Cr)_2O_3$ oxide layer.

Effects of Remanent Polarization State and Internal Field in Ferroelctric Film on the Hydrogen-induced Degradation Characteristics in Pt/Pb(Zr, Ti)O3/Pt Capacitor (강유전막의 잔류 분극 상태와 내부 전계가 Pt/Pb(Zr,Ti)O3/Pt 커패시터의 수소 열화 특성에 미치는 영향)

  • Kim, Dong-Cheon;Lee, Gang-Un;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.12 no.1
    • /
    • pp.75-81
    • /
    • 2002
  • The ferroelectric properties of Pb(Zr,Ti)O$_3$[PZT] films degrade when the films with Pt top electrodes are annealed in hydrogen containing environment. This is due to the reduction activity of atomic hydrogen that is generated by the catalytic activity of the Pt top electrode. At the initial stage of hydrogen annealing, oxygen vacancies are formed by the reduction activity of hydrogen mainly at the vicinity of top Pt/PZT interface, resulting in a shift of P-E (polarization-electric field) hysteresis curve toward the negative electric field direction. As the hydrogen annealing time increases, oxygen vacancies are formed inside the PZT film by the inward diffusion of hydrogen ions, as a result, the polarization degrades significantly and the degree of P-E curve shift decreases gradually. The direction and the magnitude of the remnant polarization in the PZT film affect the motion of hydrogen ions which determines the degradation of polarization characteristics and the shift in the P-E hysteresis curve of the PZT capacitor during hydrogen annealing. When the remnant polarization is formed in the PZT film by applying a pre-poling voltage prior to hydrogen annealing, the direction of the P-E curve shift induced by hydrogen annealing is opposite to the polarity of the pre-poling voltage. The hydrogen-induced degradation behavior of the PZT capacitor is also affected by the internal field that has been generated in the PZT film by the charges located at the top interface prior to hydrogen annealing.

Study on the Internal Temperature of Flame Resistant Treated Wood Exposed to a Standard Fire (표준화재에 노출된 방염처리 목재의 내부온도에 관한 연구)

  • Kim, Hwang-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.14-18
    • /
    • 2018
  • The earlier studies on the fire resistance performance of woods used as building materials have focused on confirming combustion characteristics of fire retardant or flame resistant treated wood. In this paper, to confirm internal temperature changes closely related to pyrolysis of woods exposed to the flame, heating experiments were conducted in a heating furnace according to the standard heating temperature curves after Douglas-fir, which is widely used as structural materials, was treated with a flame resistant solution and flame retardant paint. As a result of the experiment, it was confirmed that the thermal diffusion inside the wood has decreased when the wood was treated with the flame resistant solution. However, in high temperature, the flame resistant effect could not be expected due to the peeling of the coating in the case of the flame resistant paint treated wood. Therefore, it can be considered that it is more effective to use the flame resistant solution which penetrates in to the inside of the wood than flame resistant paint which forms the coating on the surface of the wood in order to enhance the flame resistance effect on the thick wood.

The Measurement of Spatial Dose Rate by Gravity Ventilation after Technegas Scanning (Technegas 스캐닝 후 중력환기에 의한 공간선량율 측정)

  • Kim, Sung-Bin;Won, Do-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.667-674
    • /
    • 2019
  • Because examination with technegas produces images through simple diffusion accumulation, the examination room can become contaminated after scan. Therefore, radiation workers and patients awaiting examination will be affected by internal exposure from technegas inhalation. Before and after gravity ventilation, I am trying to find a way to reduce the exposure dose of waiting patients according to a comparative analysis of horizontal spatial dose rates over time. Spatial dose ratio were measured for 10 minutes from various distances and angles around ventilator's location before and after gravity ventilation. Then, mean values, standard deviation and reduction ratio were calculated. The highest reduction rate of gravity ventilation was 95.31% and the highest reduction ratio was 1 to 3 minutes. Therefore, the gravity ventilation could reduce the exposure dose of radiologic technologists, waiting patients, patient guardians and nurses. In conclusion, the reduction of the exposure dose during the technegas ventilation study through gravity ventilation will play a role in optimiging the protection and it is in accordance with the recommended reduction of the medical exposure by ICRP 103.