• Title/Summary/Keyword: Internal Diameter

Search Result 804, Processing Time 0.029 seconds

A Study on the Development of Bubble Reduction System through Experimentation and Analysis (실험과 해석을 통한 기포저감 시스템의 개발에 대한 연구)

  • Sim, Woo-Bin;Yoo, Young-Cheol;Park, Sung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.3
    • /
    • pp.197-204
    • /
    • 2021
  • This study relates to a device that increases efficiency by reducing air bubbles in a hydraulic system used in hydraulic machinery. The reverse design and product production of the bubble reduction device, which is a commercial product overseas, was carried out. Overseas commercial products were set as the base model, a rotary rotor and an inclined rotor were added to increase the surface area of the fluid, and an annular equal distribution part with a slot in the lower part was additionally applied to distribute the fluid evenly. In addition, internal flow trends were analyzed and a system that evenly distributes the linear flow of fluid was selected as the first improvement model. Based on the first improvement model, a case where the angle of the inclined rotor is 45° was selected as the second improvement model. Based on this, as a result of setting the exit width of the annular equally distributed part as a variable, the bubble reduction efficiency was highest when the lower slot diameter of the annular part was 10mm. Finally, the system in which the average cross-sectional flow velocity decreased by 147% compared to the Base Model was derived as the final improved model.

Effect of Operating Variables on the Morphology of Precipitated Calcium Carbonate in a Slurry Bubble Reactor (슬러리 기포탑 반응기에서 침강성 탄산칼슘의 모폴로지에 대한 조업변수들의 영향)

  • Hwang, Jung-Woo;Lee, Yoong;Lee, Dong-Hyun
    • Clean Technology
    • /
    • v.16 no.2
    • /
    • pp.124-131
    • /
    • 2010
  • Effects of $Ca(OH)_2$ concentration (0.16~0.64 wt%), surfactant concentration (2~16 wt%), total volumetric flow rate (3~6 L/min) and $CO_2$ volume fraction $(0.3{\sim}0.6)$ on morphology, crystal structure, mean particle diameter, aggregation and specific surface area of the precipitated $CaCO_3$ were investigated in the slurry bubble column reactor. Experiments were carried out in acrylic reactor ($0.11\;m-ID{\times}1.0\;m-high$) with a internal tube ($0.04\;m-ID{\times}1.0\;m-high$h). The reaction time of $CaCO_3$ synthesis decreased with adding Dispex N40 of the anionic surfactant. The reaction rate of $Ca(OH)_2$ increased with increasing the volumetric flow rate of $CO_2$. From SEM images, the single crystal of $CaCO_3$ increased with increasing the reaction rate in the saturated concentration of $Ca(OH)_2$ (0.16 wt %) and the concentration of Dispex N40 (2 wt%). The mean particle size of $CaCO_3$ varied with adding Dispex N40. In addition, the specific surface area of $CaCO_3$ increased with adding of surfactant (2 wt%) from $35m^2/g$ to $44m^2/g$ at the volumetric flow rate of $CO_2$ (0.9 L/min) and the concentration of $Ca(OH)_2$(0.64 wt %).

The cumulative survival rate of dental implants with micro-threads: a long-term retrospective study

  • Dong-Hui Nam;Pil-Jong Kim;Ki-Tae Koo;Yang-Jo Seol;Yong-Moo Lee;Young Ku;In-Chul Rhyu;Sungtae Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.53-62
    • /
    • 2024
  • Purpose: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. Methods: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006-2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan-Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. Results: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between external-and internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. Conclusions: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.

An experimental study of the strength and internal structure of solder joint of fixed partial denture (가공의치(架工義齒) 납착부(蠟着部)의 강도(强度)와 내부구조(內部構造)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Sang-Nam;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.39-59
    • /
    • 1985
  • The purpose of this study was to investigate how gap distances of 0.13mm, 0.15mm, 0.20mm, and 0.30mm affects solder joint strength from gold alloys and nickel-chromium base alloys and to examine the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys. The tensile test specimens were prepared in the split stainless steel mold with a half dumbbell shape 2.5mm in diameter and l2mm in length. 6 pairs of specimens of each gap distance group of gold alloys and nickel-chromium base alloys were made and 48 pairs of all specimens were soldered with solder gold of 666 fineness. All soldered specimens were machined to a uniform diameter and then a tensile load was applied at a cross-head speed of 0.10mm/min using Instron Universal Testing Machine, Model 1115. The fractured specimens at solder gold of solder joint fracture with each gap distance of 0.13mm, 0.15mm, 0.20mm, and 0.30mm were examined under the Scanning Electron Microscope, JSM-35c and the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys was analyzed by Electron Probe Micro Analyzer. The results of this study were obtained as follows: 1. In case of soldering of gold alloys, the tensile strength between gold alloys showed $37.33{\pm}2.52kg/mm^2$ at 0.13, $39.14{\pm}3.35kg/mm^2$ at 0.15mm, $43.76{\pm}2.97kg/mm^2$ at 0.20mm, and $49.18{\pm}4.60kg/mm^2$ at 0.30mm. There was statistically significant difference at each gap distance, and so the greater increase of gap distance showed the greater tensile strength. 2. In case of soldering of nickel-chromium base alloys, the tensile strength between nickel-chromium base alloys showed $34.84{\pm}4.26kg/mm^2$ at 0.13mm, $37.25{\pm}2.49kg/mm^2$ at 0.15mm, $42.91{\pm}4.32kg/mm^2$ at 0.20mm, and $46.93{\pm}4.21kg/mm^2$ at 0.30mm. There was not statistically significant difference only between 0.13mm and 0.15mm and bet ween 0.20 mm and 0.30mm, but generally the greater increase of gap distance showed the greater tensile strength. 3. The greater increase of gap distance shoed less porosities in solder gold at solder joint fracture. 4. In solder gold Au, Cu, Ag, Zn, and Sn were composed and Au and Cu were mostly distributed uniformly. 5. In solder joints of solder gold and gold alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Au, Cu, Ag, Pt, and Pd were composed in gold alloys. Au and Cu of solder gold and gold alloys were mostly distributed uniformly and the diffusion of other elements except Pt and Pd around the solder joint was not almost found. In solder joints of solder gold and nickel-chromium base alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Ni, Cr, and Al were composed in nickel-chromium base alloys. Au and Cu of solder gold and Ni and Cr of nickel-chromium base alloys were mostly distributed uniformly and the diffusion of other elements except Cr around the solder joint was not almost found.

  • PDF

Measurement of thermal expansion characteristic of root canal filling materials : Gutta-percha and Resilon (수 종의 근관충전재의 열팽창 특성 측정 : Gutta-percha와 Resilon)

  • Jeon, Kyung-A;Lee, In-Bog;Bae, Kwang-Shik;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.344-351
    • /
    • 2006
  • The purpose of this study was to evaluate the thermal expansion characteristics of injectable ther-moplasticized gutta-perchas and a Resilon. The materials investigated are Obtura gutta-percha, Diadent gutta-percha, E&Q Gutta-percha Bar and Epiphany (Resilon). The temperature at the heating chamber orifice of an Obtura II syringe and the extruded gutta-percha from the tip of both 23- and 20-gauge needle was determined using a Digital thermometer. A cylindrical ceramic mold was fabricated for thermal expansion test, which was 27 mm long, with an internal bore diameter of 3 mm and an outer diameter of 10 mm. The mold was filled with each experimental material and barrel ends were closed with two ceramic plunger. The samples in ceramic molds were heated in a dilatometer over the temperature range from $25^{\circ}C$ to $75^{\circ}C$. From the change of specimen length as a function of temperature, the coefficients of thermal expansion were deter-mined. There was no statistical difference between four materials in the thermal expansion in the range from $35^{\circ}C$ to $55^{\circ}C$ (p > 0.05). However, Obtura Gutta-percha showed smaller thermal expansion than Diadent and Metadent ones from $35^{\circ}C$ to $75^{\circ}C$ (p < 0.05). The thermal expansion of Epiphany was similar to those of the other gutta-percha groups.

Development of Biocompatible Vascular Graft -Endothelialization of Small Vascular Graft- (생체적합성 인조혈관의 개발 -혈관내피화 인조혈관-)

  • 김형묵;이윤신
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.373-380
    • /
    • 1996
  • Prevention of thromboembolism is the most important task in the development of bioconpatible small caliber artificial vascular graft. In normal vessels, vascular endothelial cells maintain homeosatsis by secreting numerous factors. The aim of this study is to develope a method which Improves biocompatibility of small caliver polyurethane graft using endothelial cell culture technique, and ev luate the efTectiveness of extracelluar matrix for endothelization which was produced by cultured fibroblast. Methods ; Multiporous polyurethane tube of 3 mm diameter, 0.3 mm thickness was manufactured for vascular graft. Three mongrel dogs were intubated and internal jugular veins removed. Extracelluar matrix produced by cultured flbrobast which was obtained from dog's internal jugular vein were coated to the polyurethane graft. Then, endothelial cells extracted from Jugular vein were cultured and fixed on the extracelluar matrix layer of vascular graft. Endothelial cell coated vascular grafts were implanted to the carotid arteries of experimental dogs as interposed autograft. Implanted grafts were removed after 3 and 6 weeks. As a control, PTFE graft was interposed on carotid artery. These experiments demonstrated that extracelluar matrix produced by fibroblast can afford a base for endothelial cell linings of polyurethane graft. Although thrombosis were developed on autografted en othelial cell coated graft, 33% opening was noticed, and showed less adhesion to adjacent tissue layer. These findings suggest that fiboblast produced extracelluar matrix which can be used for edothelial cell lining vascular graft, and by improving the cultured endothelial cell function, there will be a new modality for reducing thrombosis on small vascular graft.

  • PDF

A 3-dimensional finite element analysis of tapered internal connection implant system (Avana SS $III^{(R)}$) on different abutment connections (경사형 내부연결 임플란트 시스템 (SS $III^{(R)}$)에서 지대주 형태에 따른 응력분포의 3차원 유한요소 분석)

  • Lee, Hye-Sung;Kim, Myung-Rae;Park, Ji-Man;Kim, Sun-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.181-188
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the stress distribution characteristics of four different abutment connections on SS-$III^{(R)}$ fixture under occlusal loading, using 3-dimensional finite element method. Materials and methods: The fixture of SS-$III^{(R)}$ (Osstem, Korea) with 4 mm diameter and 11.5 mm length and 4 types of abutments were analyzed; Solid, Com-Octa, ComOcta Gold, and Octa abutment. The models were placed in the area of first molar in the mandible. The 4 loading conditions were; (1) the vertical loading of 100 N on the central fossa, (2) the vertical loading of 100 N on the buccal cusp, (3) the $30^{\circ}$ inclined loading of 100 N to lingual side on the central fossa, and (4) the $30^{\circ}$ inclined loading of 100 N to the lingual side on the buccal cusp. The 3G.Author program was used, the von-Mises stress was calculated and the stress contours were plotted on each part of the implant systems and the surrounding bone structures. Results: Regardless of abutment types and loading conditions, higher stress concentration was observed at the cortical bone. In cancellous bone, the highest stress was observed at apical portion and the maximum stress occurred at the implant neck. The higher internal stress was observed in the fixtures than in the bone. The lowest stress was observed at loading condition 1 and the stress concentration was also lower than any other loading conditions. Conclusion: Within the limitation of the result of this study, it seems that the abutment connection type does not affect much on the stress distribution of bone structure.

The Clinical Value of Intima-media Thickness in Patients with Stable Coronary Artery Disease and C-reactive Protein within Normal Limits (경동맥 내중막 두께가 정상 C-반응성 단백질 농도를 가진 안정형 협심증 환자에서 가지는 임상적 의의)

  • Kwon, Jong-Bum;Park, Kuhn;Choi, Si-Young;Park, Chan-Beom;Kim, Yong-Hwan;Her, Sung-Ho;Park, Mahn-Won;Lee, Jong-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.482-489
    • /
    • 2010
  • Background: The purpose of this study was to determine whether hand-measured carotid intima-media thickness (IMT) was a reliable and simple tool that could be used to evaluate the severity of stable coronary artery disease (CAD) with normal high-sensitivity C-reactive protein (CRP). Material and Method: We examined left carotid IMTs in 688 patients with stable CAD and excluded 121 patients with abnormally elevated hs-CRP ($\geq$0.5 mg/dL). We sought to determine the association between risk factors and the severity of stable CAD and carotid IMT in 567 patients who were divided into lower and higher groups based on the median value. Patients underwent a coronary artery angiogram and had at least significant stenosis (>50% of the original luminal diameter involving one or more major coronary artery). Result: Of the 567 patients, 300 (52.9%) were in the lower IMT group and 267 (47.1%) were in the higher IMT group; the median value was 0.76 mm. By multivariable logistic regression analysis, the following groups were different: older age (~49 vs. 70~ years, respectively; OR=6.552), high FBS (~99 vs. 120~ mg/dL; OR=1.713) and severity of CAD (1 vessel vs. 2 vessel disease; OR=1.711, 1 vessel vs. 3 vessel disease; OR=1.714). Conclusion: We conclude that there are correlations between increased carotid IMT and severity of CAD in stable angina patients with normal CRP levels.

Stress Patterns in the Reconstructed Double Bundles of the Anterior Cruciate Ligament in Response to an Anterior Tibial Load and Rotatory Load: an Analysis using a 3-Dimensional Finite Element Model (삼차원 유한 요소 모델을 이용한 전방십자인대 이중다발 재건술 후 전방 전위 및 회전 부하에 따른 이식건 응력 양상 분석)

  • Seo, Young-Jin;Song, Si Young;Ahn, Jung Tae;Kim, Yoon-Sang;Ko, Jun Ho;Jang, Seong-Wook;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.160-166
    • /
    • 2012
  • Purpose: The aim of this study was to determine the patterns of the stress distribution within the reconstructed anterior cruciate ligament (ACL) double bundles in response to an anterior tibial load and rotatory load at $45^{\circ}$ flexed knee model by use of a 3-dimensional finite element analysis (FEM). Materials and Methods: The $0^{\circ}$ and $45^{\circ}$ flexed 3-D knee model were reconstructed based on the high resolution computed tomography (CT) images from the right knee of a healthy male subject. To simulate double bundle ACL reconstruction, in $0^{\circ}$ analytic model, four 7 mm diameter tunnels were created at the center of each anteromedial (AM) and posterolateral (PL) footprints on the femur and tibia. The grafts were inserted into the corresponding bone tunnels and then reconstructed knee model was flexed to $45^{\circ}$. As a next step, the 5 mm anterior tibial load and internal rotational load of $10^{\circ}$ were applied on the final Computer aided design (CAD) model. And then stress patterns of each bundle were assessed using a finite element analysis. Results: In response to the 5 mm of anterior tibial load, the AM bundle showed increased stresses around the tibial and femoral attachment sites; especially in the anterior aspect of the bundle. In the PL bundle, the highest stress concentration was also noticed on the anterior aspect of the bundle. Under $10^{\circ}$ internal rotational load, the stress concentration was predominant around the anterior aspect of the tibial attachment site within the AM bundle. The PL bundle also showed highest stress concentration on the anterior aspect of the bundle. Conclusion: Although the stress patterns were not identical among the AM and PL bundle, there were common trends in the stress distribution. The stress concentration was predominant on the anterior aspect of both bundles in response to the anterior tibial load and rotatory load.

  • PDF

Characteristics of Phytoplankton Succession Based on the Functional Group in the Enclosed Culture System (대형 배양장치에서 기능그룹에 기초한 식물플랑크톤 천이 특성)

  • Lee, Kyung-Lak;Noh, Seongyu;Lee, Jaeyoon;Yoon, Sungae;Lee, Jaehak;Shin, Yuna;Lee, Su-Woong;Rhew, Doughee;Lee, Jaekwan
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.4
    • /
    • pp.441-451
    • /
    • 2017
  • The present study was conducted from August to December 2016 in a cylindrical water tank with a diameter of 1 m, a height of 4 m and a capacity of 3,000 L. The field water and sediment from the Nakdong River were also sampled for the experimental culture (field water+sediment) and control culture (field water), respectively. In this study, we aimed to investigate phytoplankton succession pattern using the phytoplankton functional group in the enclosed culture system. A total of 50 species in 27 genera including Chlorophyceae (30 species), Bacillariophyceae (11 species), Cyanophyceae (7 species), and Cryptophyceae (2 species) were identified in the experimental and control culture systems. A total of 19 phytoplankton functional groups (PFGs) were identified, and these groups include B, C, D, F, G, H1, J, K, Lo, M, MP, N, P, S1, $T_B$, $W_0$, X1, X2 and Y. In particular, $W_0$, J and M groups exhibited the marked succession in the experimental culture system with higher biovolumes compared to those of the control culture system, which may be related to the internal cycling of nutrients by sediment in the experimental culture system. The principal component analyses demonstrated that succession patterns in PFG were associated with the main environmental factors such as nutrients(N, P), water temperature and light intensity in two culture systems. In conclusion, the present study showed the potential applicability of the functional group for understanding the adaptation strategies and ecological traits of the phytoplankton succession in the water bodies of Korea.