• 제목/요약/키워드: Internal Diameter

검색결과 804건 처리시간 0.028초

Effects of alfaxalone on echocardiographic examination in healthy dogs

  • Kim, Ye-Won;Kim, Tae-Jun;Hyun, Changbaig
    • 대한수의학회지
    • /
    • 제55권4호
    • /
    • pp.221-225
    • /
    • 2015
  • This study evaluated the effects of alfaxalone (3 mg/kg, intravenously) on echocardiographic examination in healthy dogs using echocardiography. Six adult Beagle dogs were used for this study. Left ventricular dimensions with systolic indexes, trans-blood flow at all cardiac valvular annulus and trans-mitral tissue Doppler values were measured from routine transthoracic echocardiography. Although the changes were not statistically significant, heart rate, left ventricular end-systolic diameter, left ventricular end-diastolic diameter, peak velocities of tricuspid A-wave and transpulmonic flow were increased after alfaxalone induction, while systolic blood pressure, fractional shortening, left ventricular ejection fraction, peak velocities of mitral E-wave, mitral A wave, tricuspid E-wave, transaortic flow and medial e'-, a'- and s'-peaks decreased after alfaxalone induction. No dogs showed hypoxemia during sedation, regardless of intubation and oxygen supply. Although alfaxalone showed mild cardiovascular depression, this protocol could be a good alternative sedative protocol for echocardiographic examination in healthy dogs because the cardiovascular depression was statistically and clinically insignificant. However, further studies in dogs with heart diseases should be conducted to confirm these findings after alfaxalone induction.

평관형 및 나선 그루브형 열사이폰 내부 작동유체의 포화온도와 단열부의 표면온도에 관한 연구 (A Comparison between the Internal Saturation Temperature of Working Fluid and the Surface Temperature of Adiabatic Zone of Two-Phase Closed Thermosyphons with Various Helical Grooves)

  • 한규일;조동현;박종운;이상진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1243-1249
    • /
    • 2004
  • This study is focused on the comparison between the internal saturation temperature of the working fluid and the surface temperature of adiabatic zone of two-phase closed thermosyphons with various helical grooves. Distilled water, methanol and ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The results show that the numbers of grooves and the type of working fluids are very important factors for the operation of thermosyphons. A good agreement between the internal saturation temperature of working fluid and the surface temperature of adiabatic zone of two-phase closed thermosyphons with various helical grooves is obtained.

  • PDF

이중층 자가조립 공정을 활용한 롤형태의 생체의료용 마이크로섬유 구조체 제작 (Fabrication of Microfibrous Structures with Rolled-Up Forms using a Bilayer Self-Assembly Process)

  • 김영서;박석희
    • 한국기계가공학회지
    • /
    • 제21권2호
    • /
    • pp.79-86
    • /
    • 2022
  • Numerous fabrication techniques have been used to mimic cylindrical natural tissues, such as blood vessels, tendons, ligaments, and skeletal muscles. However, most processes have limitations in achieving the biomimetic properties of multilayered and porous architectures. In this study, to embrace both features, a novel self-assembly method was proposed using electrospun microfibrous sheets. A bilayer microfibrous structure, comprising two sheets with different internal stresses, was fabricated by electrospinning a polycaprolactone (PCL) sheet on a uniaxially stretched thermoplastic polyurethane (TPU) sheet. Then, by removing the stretching tension, the sheet was rolled into a hollow cylindrical structure with a specific internal diameter. The internal diameter could be quantitatively controlled by adjusting the thickness of the PCL sheet against that of the TPU sheet. Through this self-assembly method, biomimetic cylindrical structures with multilayer and porous features can be manufactured in a stable and controllable manner. Therefore, the resulting structures may be applied to various tissue engineering scaffolds, especially vascular and connective tissues.

임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향 (Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants)

  • 윤보혁;신현모;윤미정;허중보;정창모;강은숙
    • 대한치과의사협회지
    • /
    • 제53권9호
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

한우에서의 초음파화상진단에 관한 연구 (Fundamental Studies on the Ultrasonographic Diagnosis in Korean Native Cattle)

  • 김명철;박관호
    • 한국임상수의학회지
    • /
    • 제12권1호
    • /
    • pp.861-876
    • /
    • 1995
  • This study was carried out to get fundamental information about the normal ultrasonogram of the liver and heart in Korean native cattle and calves. The interventricular septum, left ventricular internal diameter, left ventricular free wall thickness, aortic diameter, left atrial diameter, and right ventricular internal diameter of hear in 10 Korean native calves were determined at 4-5 right intercostal spare by use of ultrasonography. The caudal vena cava, portal vein, gallbladder, liver of 9 Korean native cattle and 10 calves were determined at 12, 11 and 10th intercostal spares by use of ultrasonography. Cursor-directed M-mode and gray-scale, B-mode ultrasonograms were obtained with electronic scanning ultrasound equipment with a 3.5 or 5.0-MHz convex transducer. The results obtained through the experiments were summarized as follows: 1. The result of ultrasonographic examination of the korean native calves' heart 1) Interventricular septum in systole and diastole was 1.23 and 0.81 cm, respectively(vc=28.84, 17.4). 2) Ventricular internal diameter in systole and diastole was 2.50 and 4.91 cm, respectively(vc=17.44, 12.73). 3) Left ventricular free was thickness in systole and diastole was 1.44 and 0.92 cm, respectively(vc=26.85, 23.54). 4) Aortic diameter was 2.69.m, .rspectevely(vc=11.29). 5) Left atrial diameter was 1.82 cm(vc=15.31). 6) Right ventricular internal diameter in systole and diastole was 1.12 and 1.9 cm, respectively(vc=33.71, 24.43). 3. Ultrasonographic measurments of caudal vena cava, portal vein, gallbladder of Korean native calves 1) Dorsal margin of caudal vena cava at the 12, 11 and 10th intercostal space was 13.5, 15.3 and 18.1 cm, respectively(p<0.01). 3) Depth of caudal vena cava at the 12, 11 and 10th intercostal space was 4.4, 4.5 and 4.6 cm, respectively. 3) Diameter of caudal vena cava at the 12, 11 and 10th intercostal space was 11.6, 1.7 and 1.6 cm, respectively. 4) Dorsal margin of portal vein at the 12, 11 and 10th intercostal space was 16.2, 18.6 and 21.4 cm, respectively(p<0.01) 5) Depth of portal vein at the 12, 11 and 10th intercostal spare was 4.5, 4.4 and 3.9 cm respectively. 6) Diameter of portal vein at the 13, 11 and 10th intercostal space was 2.1, 2.2 and 1.9 cm respectively. 7) Dorsal margin of gallbladder at the 11 and 10th intercostal space was 23.6 and 23.9 cm, respectively(p<0.01), 8) Longitudinal diameter of gallbladder at the 11 and 10th intercostal space was 7.1 and 5.9 cm, respectively(p<0.05). 9) Transverse diameter of gallbladder at the 11 and 10th intercostal space was 2.4 and 2.1 cm respectively(p<0.01). 3. Ultrasonographic measurments of caudal vena cava, portal vein, gallbladder of Korean native cattle 1) Dorsal margin of caudal vena cava at the 12 and 11th intercostal space was 22.2, and 25.4 cm, respectively(p<0.01). 2) Depth of caudal vena cava at the 12 and 11th intercostal space was 103 and 11.1 cm, respectively(p<0.01). 3) Diameter of caudal vena cava at the 12 and 11th intercostal space was 3.1 and 3.0 cm, respectively. 4) Dorsal margin of portal vein at the 12 and 11th intercostal space was 29.3 and 32.9 cm, respectively(p<0.01). 5) Depth of portal vein at the 12 and 11th intercostal space was 9.6, and 9.2 cm, respectively. 6) Diameter of portal vein at the 12 and lith intercostal space was 3.4 and 3.3 cm, respectively. 7) Dorsal margin of gallbladder at the 11 and 10th intercostal space was 43.1 and 45.5 cm, respectively(p<0.01). 8) Longitudinal diameter of gallbladder at the 11 and 10th intercostal space was 10.1 and 9.4 cm, respectively. 9) Transverse diameter of gallbladder at the 11 and 10th intercostal space was 4.0 and 3.7 cm, respectively. 4, Ultrasonogaphic measurments of dorsal margin, ventral margin, size and angles of the Korean native calves' liver. 1) Dorsal margin of liver at the 12, 11 and 10th intercostal space was 11.0, 9.6, and 12.4 cm, respectively(p<0.01). 2) Ventral margin of liver at the 12, 11 and 10th intercostal spate was 20, 24 and 26.1 cm, respectively(p<0.01). 3) Size of the liver at the 12, 11 and 10th intercostal space was 9.0, 14.6 and 13.8 cm, respectively(p<0.01). 4) Angle of liver at the 12, 11 and 10th intercostal space was 40, 46 and 37, respectively(p<0.01). 5. Ultrasonographic measurmants of dorsal margin, ventral margin, size and anglses of the korean native cattle's liver 1) Dorsal margin of the liver at the 12, 11 and 10th intercostal space was 14.4, 18.2 and 26, 3 cm, respectively. 2) Ventral margin of liver at the 12, 11 and 10th intercostal space was 41.1, 46.4 and 49.3 cm, respectively(p<0.01). 3) Size of the liver at the 12, 11 and 10th intercostal space was 26.8, 28.2 and 23.2 cm, respectively(p<0.01). 4) Angel of liverat the 15, 11 and 10 intercostal space was 41, 40.6 and 35.7, respectively(p<0.05). It was concluded that the ultrasonographic values oletermined in this study can be used as references for the diagnosis of morphologic changes in the hear and liver in korean native calves, and in the liver in korean native rattle.

  • PDF

횡복직근 유리피판을 이용한 지연유방재건에서 수용부 혈관의 선택 (Selection of Recipient Vessels in Delayed Breast Reconstruction with Free TRAM Flap)

  • 안희창;이한얼;김정태;최승석
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.569-573
    • /
    • 2007
  • Purpose: The selection of the recipient vessels in breast reconstruction has a great influence on the surgical result and the shape of the reconstructed breast. We would like to introduce the criteria for the selection of recipient vessels in delayed reconstruction of the breast. Methods: We studied 56 patients with delayed breast reconstruction using free TRAM flaps from April 1994 to December 2006. The thoracodorsal and the ipsilateral internal mammary vessels were used as recipients in 25 patients each, the opposite internal mammary vessels in 3 patients, the thoracoacromial vessels in 2 patients, and the transverse cervical artery with the cephalic vein in 1 patient. The survival rate of the flaps, the vessel diameter, the length of the pedicles, and the convenience of vessel dissection were studied. Results: The diameter of the recipient vessel did not influence the anastomosis. The operation time, the survival rate of flap, the postoperative complications showed no significant difference according to the recipient vessel. Dissection of the thoracodorsal vessels was tedious due to scar formation from the prior operation. Dissection of the internal mammary vessels proved to be relatively easy, and the required length of the pedicle was shorter than any other site, but the need for removal of rib cartilage makes this procedure inconvenient. Conclusion: The first choice of the recipient vessel in immediate breast reconstruction is the thoracodorsal vessels, but in cases of delayed reconstruction the internal mammary vessels are favored as the first choice, because the thoracodorsal vessels have a high unusability rate. If the ipsilateral internal mammary vessels prove to be useless, the contralateral vessels can be used. The thoracoacromial vessels are useful, when the mastectomy scar is located in the upper portion. The transverse cervical artery and the cephalic vein can serve as the last resort, if all other vessels are unreliable.

Atomization Characteristics in Pneumatic Counterflowing Internal Mixing Nozzle

  • Lee, Sam-Goo;Rho, Byung-Joon
    • Journal of Mechanical Science and Technology
    • /
    • 제14권10호
    • /
    • pp.1131-1142
    • /
    • 2000
  • In an effort to illustrate the global variation of SMD (Sauter mean diameter, or $D_{32}$) and AMD (Arithmetic mean diameter, or $D_{10}$) at five axial downstream locations (i. e., at Z=30, 50, 80, 120, and 170 mm) under the different experimental conditions, the radial coordinate is normalized by the spray half-width. Experimental data to analyze the atomization characteristics concerning with an internal mixing type have been obtained using a PDPA(Phase Doppler Particle Analyzer). The air injection pressure was varied from 40 kPa to 120 kPa. In this study, counterflowing internal mixing nozzles manufactured at an angle of $15^{\circ}$with axi-symmetric tangential-drilled four holes have been considered. By comparing the results, it is clearly possible to discern the effects of increasing air pressure, suggesting that the disintegration process is enhanced and finer spray droplets can be obtained under higher air assist. The variations in $D_{32}$ are attributed to the characteristic feature of internal mixing nozzle in which the droplets are preferentially ejected downward with strong axial momentum, and dispersed with the larger droplets which are detected in the spray centerline at the near stations and smaller ones are generated due to further subsequent breakup by higher shear stresses at farther axial locations. The poor atomization around the centre close to the nozzle exit is attributed to the fact that the relatively lower rates of spherical particles are detected and these drops are not subject to instantaneous breakup in spite of the strong axial momentum. However, substantial increases in SMD from the central part toward the edge of the spray as they go farther downstream are mainly due to the fact that the relative velocity of droplet is too low to cause any subsequent disintegration.

  • PDF

Comparison of the second and third intercostal spaces regarding the use of internal mammary vessels as recipient vessels in DIEP flap breast reconstruction: An anatomical and clinical study

  • Seong, Ik Hyun;Woo, Kyong-Je
    • Archives of Plastic Surgery
    • /
    • 제47권4호
    • /
    • pp.333-339
    • /
    • 2020
  • Background The purpose of this study was to compare the anatomical features of the internal mammary vessels (IMVs) at the second and third intercostal spaces (ICSs) with regard to their use as recipient vessels in deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. Methods A total of 38 consecutive DIEP breast reconstructions in 36 patients were performed using IMVs as recipient vessels between March 2017 and August 2018. The intraoperative findings and postoperative complications were analyzed. Anatomical analyses were performed using intraoperative measurements and computed tomography (CT) angiographic images. Results CT angiographic analysis revealed the mean diameter of the deep inferior epigastric artery to be 2.42±0.27 mm, while that of the deep inferior epigastric vein was 2.91±0.30 mm. A larger mean vessel diameter was observed at the second than at the third ICS for both the internal mammary artery (2.26±0.32 mm vs. 1.99±0.33 mm, respectively; P=0.001) and the internal mammary vein (IMv) (2.52±0.46 mm vs. 2.05±0.42 mm, respectively; P<0.001). Similarly, the second ICS was wider than the third (18.08±3.72 mm vs. 12.32±2.96 mm, respectively; P<0.001) and the distance from the medial sternal border to the medial IMv was greater (9.49±2.28 mm vs. 7.18±2.13 mm, respectively; P<0.001). Bifurcations of the IMv were found in 18.4% of cases at the second ICS and in 63.2% of cases at the third ICS. Conclusions The IMVs at the second ICS had more favorable anatomic features for use as recipient vessels in DIEP flap breast reconstruction than those at the third ICS.

$^{99m}Tc-RBC$ SPECT를 이용한 간혈관종의 진단 (Diagnosis of Hepatic Hemangioma with $^{99m}Tc-Labeled$ Red Cells and Single Photon Emission Computed Tomography (SPECT))

  • 문대혁;조시만;이명혜;양석균;정영화;이영상;신성해;홍기석
    • 대한핵의학회지
    • /
    • 제25권1호
    • /
    • pp.68-75
    • /
    • 1991
  • The value of $^{99}Tc-RBC$ scintigraphy and SPECT in the diagnosis of hepatic hemangioma was evaluated in 27 patients with 38 hemangiomas and 13 patients with 15 nonhemangiomas. Twenty four (63.2%) of 38 hemangiomas were detected by planar delayed RBC imaging, whereas 30 (78.9%) hemangiomas were detected by the delayed RBC SPECT. Increase in sensitivity was noted in nodules less than 2 cm in diameter. The smallest hemangioma shown by delayed RBC SPECT was 0.9 cm in diameter. All of nonhemangiomatous lesions show normal or decreased activity in delayed blood pool images. We concluded that $^{99m}Tc-RBC$ SPECT is an accurate method for the detection of hepatic hemangioma and is more sensitive than planar imaging in depicting small lesions.

  • PDF