• Title/Summary/Keyword: Internal Defects

Search Result 509, Processing Time 0.052 seconds

Defects control in SiC single crystals (SiC 단결정내의 결함 억제)

  • 김화목;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 1998
  • Substrates, SiC raw materials and graphite crucibles were purified for growing the high quality 6H-SiC single crystal ingot. Especially, XRD data of raw materials were analyzed before and after purification. We have grown 6H-SiC single crystal ingot up to 33 mm in diameter and 11 mm in length and SiC wafer for using the substrate and observing the internal defects was about 33 mm in diameter and 0.5 mm in thickness. Utilizing optical microscpe and Raman spectroscopy, internal defects density and crystallinity of the SiC wafer obtained by purification processes before crystal growth were measured. As a result, micropipe density and planar defect density were 100/$\textrm{cm}^2$ and 30/$\textrm{cm}^2$ respectively. Therefore, high quality 6H-SiC single crystal could be grown because internal defects density of 6H-SiC single crystal ingot was decreased by the purification processes before crystal growth.

  • PDF

A Case Report on Treating Post-stroke Visual Impairment with Gami-banhabakchulchunma-tang and Acupuncture (가미반하백출천마탕과 침치료를 통한 한의치료로 호전된 뇌경색 후 시야장애 환자 치험 1례)

  • Kim, Jeong-hui;Kim, Hae-yoong;Won, Seo-young;Ryu, Ju-young;Jung, Eun-sun;Yoo, Ho-ryong;Seol, In-chan;Kim, Yoon-sik
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.5
    • /
    • pp.1045-1053
    • /
    • 2021
  • Objectives: This study investigated the effectiveness of acupuncture and herbal medicine (Gami-banhabakchulchunma-tang) for post-stroke visual impairment. Methods: A 79-year-old male with headache, dizziness, visual field defects, and blurred vision caused by a posterior cerebral infarction was treated with acupuncture and Gami-banhabakchulchunma-tang for three months. We used the Numerical Rating Scale (NRS) for each symptom and measured the patient's eye-movement range. Results: Following treatment, the NRS score for headache decreased from 5 to 0, and for dizziness and blurred vision, it decreased from 5 to 1. The NRS score for visual field defects decreased from 5 to 2. The range of the patient's left and right eye movements both improved, and no adverse side effects were observed during the admission period. Conclusions: Korean medical treatment with acupuncture and herbal medicine (Gami-banhabakchulchunma-tang) could effectively treat post-stoke visual impairment.

The Characteristics of Fatigue Cracks Emanating from Small Hole Defects Located Opposite Position of the Shaft Cross Section (축단면 내 대칭위치에 존재하는 원공결함에서 발생하는 피로균열 거동)

  • Song, Sam-Hong;An, Il-Hyeok;Lee, Jeong-Mu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.84-91
    • /
    • 2002
  • The shaft with the circular cross section have symmetric structural combination parts to keep the rotating balance. Hence the crack usually emanate from symmetric combination parts due to the stress concentration of these parts. In this study to estimate the fatigue behavior of symmetric cracks, the fatigue test was performed by using rotary bending tester and the specimen with symmetric defects in circular cross section. From the facts the characteristics of crack initiation and propagation on the symmetric surface cracks in circular cross section was examined. Also we observed the internal crack using oxidation coloring and investigated the fatigue behavior using the relationship between surface crack and internal crack. As a result of fatigue lift of symmetric cracks was reduced to 35% compared to single crack’s. We examined the characteristics of fatigue behavior in element with symmetric cracks using internal crack propagation rate and maximum stress intensity factor range obtained from approximation method.

Reconstruction of Combined Oral Mucosa-Mandibular Defects Using the Vascularized Myoosseous Iliac Crest Free Flap

  • Jung, Hwi-Dong;Nam, Woong;Cha, In-Ho;Kim, Hyung Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.4137-4140
    • /
    • 2012
  • The authors present five cases of combined oral mucosa-mandible defects reconstructed with the vascularized internal oblique-iliac crest myoosseous free flap. This technique has many advantages compared to other conventional methods such as the radial flap, scapula flap, and fibula flap. Vascularized iliac crest flaps provide sufficient high-quality bone suitable for reconstructing segmental madibular defects. Although fibular flaps allow longer donor bone tissue to be harvested, the iliac crest can provide an esthetic shape for mandibular body reconstruction and also provides sufficient bone height for dental implants. Conventional vascularized iliac crest myoosseous flaps have excessive soft tissue bulk for reconstruction of intraoral soft tissue defects. The modification discussed in the present article can reduce soft tissue volume, resulting in better functional reconstruction of the oral mucosa. Another advantage is that complete replacement of the oral mucosa is observed in as early as one month post-operation. The final mucosal texture is much better than that obtained with other skin paddle flaps, which is especially beneficial for the placement of dental implant prostheses. Donor site morbidity looks to be similar to, if not less than that observed for other modalities in terms of function and esthetics. For combined oral mucosa-mandible defects, the vascularized internal oblique-iliac crest myoosseous free flap shows good results with respect to hard and soft tissue reconstruction.

Development of New Low Frequency ECT Sensor to Detect Inner Defects(II) - Application to Welding Specimens Included Defects - (내부결함 검출 가능한 저주파 ECT 센서개발(II) - 결함을 가진 소형 용접시험편에 적용 -)

  • Park, Jeong-Ung;Jang, Mun-Seok;Gim, Guk-Ju;Kim, Beom-Ki
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.63-67
    • /
    • 2015
  • Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing(ECT) is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. The New ECT sensor which can detect inner defects was developed regardless the condition of surface. This sensor is verified to do experiment which measure the loss of induced electromotive force. The loss of induced electromotive force was measured in 5.4% and this low frequency ECT device can detect internal defects at depth 20 mm.

Crystallinity and Internal Defect Observation of the ZnTe Thin Film Used by Opto-Electronic Sensor Material (광소자로 사용되는 ZnTe박박의 결정성에 따른 결함 관찰)

  • Kim, B.J.
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.5
    • /
    • pp.289-294
    • /
    • 2002
  • ZnTe films have been grown on (100) GaAs substrate with two representative problems. The one is lattice mismatch, the other is thermal expansion coefficients mismatch of ZnTe /GaAs. It claims here, the relationship of film thickness and defects distribution with (100) ZnTe/GaAs using hot wall epitaxy (HWE) growth was investigated by transmission electron microscopy (TEM). It analyzed on the two-sort side using TEM with cross-sectional transmission electron microscopy (XTEM) and high-resolution electron microscopy (HREM). Investigation into the nature and behavior of dislocations with dependence-thickness in (100) ZnTe/ (100) GaAs hetero-structures grown by transmission electron microscopy (TEM). This defects range from interface to 0.7 $\mu\textrm{m}$ was high density, due to the large lattice mismatch and thermal expansion coefficients. The defects of low density was range 0.7$\mu\textrm{m}$~1.8$\mu\textrm{m}$. In the thicker range than 1.8$\mu\textrm{m}$ was measured hardly defects.

Assessment of Forming Defects in Hot Backward Extruded Ti-6Al-4V Tubes using Dynamic Materials Model (동적재료모델을 활용한 열간 후방압출된 Ti-6Al-4V튜브의 성형결함 해석)

  • 염종택;심인규;박노광;홍성석;심인옥
    • Transactions of Materials Processing
    • /
    • v.12 no.6
    • /
    • pp.566-571
    • /
    • 2003
  • The metal forming behavior and defect formation in Ti-6Al-4V tube during hot backward extrusion were investigated. Dynamic material model(DMM) including Ziegler's instability criterion was employed to predict the forming defects such as shear band, inner and/or surface cracks. This approach was coupled to the internal variables generated from FE analysis. The simulation results fur the backward extrusion were compared with the experimental observation. The chilling effect and friction indicated a great influence on the deformation mode of the tube and the formation of surface cracks. The formation of forming defects in the extruded tube was attributed to non-uniform distribution of strain, strain rate and temperatures in the extruded tubes for the given test conditions.

Reconstruction of Large Defects in the Perineal Area Using Multiple Perforator Flaps

  • Sung, Ki Wook;Lee, Won Jai;Yun, In Sik;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.446-450
    • /
    • 2016
  • Background Perineal defects are commonly encountered during the treatment of conditions such as malignancy, infectious disease, and trauma. Covering large defects in the perineal area is challenging due to its complicated anatomy and the need for functional preservation. Methods Fourteen patients who underwent reconstructive surgery with multiple perforator flaps for defects >$100cm^2$ in the perineal area were included in this retrospective cohort study. Characteristics of the perforator flap operation and postoperative outcomes were reviewed. Results Reconstruction was performed using 2 perforator flaps for 13 patients and 3 perforator flaps for 1 patient. Internal pudendal artery perforator flaps were mainly used for covering the defects. The average defect size was $176.3{\pm}61.8cm^2$ and the average size of each flap was $95.7{\pm}31.9cm^2$. Six patients had minor complications, such as wound dehiscence and partial necrosis of the flap margin, which were corrected with simple revision procedures. Conclusions Multiple perforator flaps can be used to achieve successful reconstructions of large perineal defects that are difficult to reconstruct with other coverage methods.