• 제목/요약/키워드: Intermittent Aeration

검색결과 78건 처리시간 0.044초

생물학적 질소.인 제거를 위한 SMMIAR(Submerged Moving Media Intermittent Aeration Reactor) 공정의 운전 특성 (The Operating Characteristics of SMMIAR process for Biological Nitrogen.phosphorus Removal)

  • 김홍태;김학석;김규창
    • 한국환경과학회지
    • /
    • 제12권1호
    • /
    • pp.55-61
    • /
    • 2003
  • This study was carried out to obtain the operating characteristics of SMMIAR process for biological nitrogenㆍphosphorus removal. SMMIAR was operated at HLR(Hydraulic loading rate) of 39.6, 52.8, 63.4 and 79.2 $\ell$/$m^2$/d respectively and the operating parameters such as intermittent aeration time ratio of aerobic/anoxic, DO and microorganism concentration were changed to confirm the optimum operating condition. The concentrations of the wastewater BOD, TN(Total nitrogen) and TP(Total phosphorus) were 150, 30 and 7.5mg/$\ell$ respectively. Achieving better removal efficiencies of BOD, TN and TP up to 90, 85.4 and 95.4% respectively, we must keep in operation condition of SMMIAR by 0.75 of time ratio of aerobic/anoxic and by minimum 45 minutes of oxic period simultaneously.

ORP와 pH 측정에 의한 간헐폭기 고도처리 공정 제어의 평가 (State Evaluation of Nutrient Removal in an Intermittent Aeration Process by Monitoring ORP & pH)

  • 고광백;서준석
    • 한국물환경학회지
    • /
    • 제18권4호
    • /
    • pp.401-409
    • /
    • 2002
  • In this study, to evaluate the applicability of ORP and pH as process control parameters for an intermittent aeration process, a 200L/d bench-scale plant was installed and operated for 90 days. It was fed with synthetic wastewater which contained $COD_{Cr}$ : 400mg/L, TN : 40mg/L and TP : 7mg/L. ORP & pH were measured on-line and compared with the variation of nutrient concentrations. As the results, both of the ORP and pH were able to monitor successfully nitrification and denitrification. Bending-points on the ORP curve and peak points on the pH curve corresponded to the termination of nitrification and denitrification. For P uptake and release, pH was the best indicator for performance evaluation. The aerobic pH apex was appeared when P uptake was accomplished and there was a relationship between the P release and pH variation. But the pH curve needed filtering because there were many noises on it. In this study, the shape of the ORP & pH curves were varied as the operating conditions such as aeration rates and organic loads were changed. It allowed the operating states of biological systems to be effectively evaluated. If it is properly managed to show the bending points and peak points clearly, the on-line monitoring of ORP & pH will be a reliable and effective technique for process control of intermittent aeration processes.

Bioaugmentation이 간헐폭기 오수처리장치의 운전효율에 미치는 영향 (Effect of Bioaugmentation on Performance of Intermittently Aerated Sewage Treatment Plant)

  • 정병곤
    • 한국환경보건학회지
    • /
    • 제34권3호
    • /
    • pp.233-239
    • /
    • 2008
  • In order to improve reactor performance of existing sewage treatment plants, the feasibility of enhancing reactor performance by bioaugmentation using EM as bioaugmentation agent and the effects of anoxic: oxic time ratio on reactor performance were investigated. Continuous and intermittent aeration modes were compared under the 6 hr of HRT. Three different types of intermittent aeration modes, that is, 15 min, of anoxic:45 min of oxic, 30 min of anoxic: 30 min of oxic, and 45 min of anoxic: 15 min oxic respectively were chosen as test modes to study the effects of anoxic : oxic time ratios on reactor performance. The optimum anoxic: oxic time ratio was 30 min:30 min when considering simultaneous removal of organic, nitrogen and phosphorus. When applying EM into a continuously aerated reactor under the varying dosing rates of 50-200 ppm, reactor performance in terms of organic and nitrogen removal efficiencies was not improved at all. Nitrogen removal efficiency was increase when the EM dosing rate was increased. However the degree of improvement was slight when the EM was injected above 100 ppm. However optimum phosphorus removal was found at the EM dosing of 200 ppm. Thus it was found that optimum injection concentration of EM is 200 ppm. It is apparent that putting EM into a sewage treatment plant significantly affects the T-N removal efficiency of the reactor by enhancing denitrification efficiency especially in operational conditions of relatively long anoxic periods. To achieve reciprocal condition in a reactor with intermittent aeration it is necessary to enhance the reactor performance by EM injection. In the case of modifying existing continuously aerated reactors into intermittent aerated reactors, it is obvious that operating costs of aeration would be reduced by reducing aeration time when compared with existing conventional sewage treatment plants.

연속회분식반응조를 이용한 슬러지 소화에서 고형물과 질소의 제거 (Solids and Nitrogen Removal in the Sludge Digestion using a Sequencing Batch Reactor)

  • 김성홍;이윤희
    • 대한토목학회논문집
    • /
    • 제26권6B호
    • /
    • pp.669-675
    • /
    • 2006
  • SBR반응조를 이용하여 간헐폭기의 슬러지소화 실험을 실시하였다. 폭기비율은 고형물과 질소 제거의 가장 중요한 운전인자 중의 하나였다. 슬러지의 소화에 따라 용출된 유기성질소는 질산성질소로 산화되었고, 생물학적 질소제거율도 높게 나타났는데, 질소제거율은 폭기비율에 따라 달라졌다. 폭기비율 0.25-0.75의 범위에서, 암모니아성 질소의 축적은 보이지 않았으며, pH는 중성에서 유지되었다. 폭기비율을 증가시킴에 따라 고형물 제거율은 증가하지만 용존 질소의 제거율은 감소하는 경향을 보였다. 본 실험에서 SBR 반응조를 이용하고, 평균고형물체류시간 8-32일 정도의 설계조건과 폭기비율 0.25-0.75의 운전 조건에서 VSS 제거율은 17-42% 정도, 용존질소 제거율은 80% 이상이 가능하였다.

간헐포기소화의 비용 평가 (Cost Estimation of Intermittent Aerobic Digestion)

  • 김운중;김성홍;김희준
    • 대한토목학회논문집
    • /
    • 제26권1B호
    • /
    • pp.113-118
    • /
    • 2006
  • 간헐포기방식의 슬러지 소화 기술에 대한 비용을 분석하였다. 포기비율은 간헐포기소화의 가장 중요한 설계인자이며, 포기 비율에 따라 시설비와 동력비가 달라진다. 목표 SS 제거율을 35%로 설정하고, 철근콘크리트형식의 SBR 간헐포기소화조를 설계하였으며, 이로부터 시설비와 동력비를 산출하였다. 비용 평가는 할인율과 경제성장율을 고려하는 현재가치로 환산하는 방법을 사용하였다. 포기비율이 낮은 경우는 시설비가 높지만 동력비는 적게 소요되며, 포기비율이 높으면 반대로 시설비는 낮지만 동력비는 증가한다. 초기시설비는 호기성 소화가 간헐포기소화보다 더 저렴하다. 그러나, 총비용면에서 내용연수 약 10년 이상의 운전에서는 간헐포기소화가 호기성 소화보다 더 유리하다. 특히, 내용연수가 길수록 최적 포기비율은 낮아지며, 내용연수가 45년 정도일 때 최적포기비율은 0.3 정도이고, 이 경우 총비용은 호기성소화의 64% 수준이다.

回分式 발효조에서 牛糞과 왕겨 混合物의 間歇 通氣 堆肥化 (Intermittent Aeration Composting of Cattle Manure with Rice Hulls in a Batch Composter)

  • 홍지형;박금주;순보균
    • 한국축산시설환경학회지
    • /
    • 제2권2호
    • /
    • pp.123-133
    • /
    • 1996
  • Recently, a greater interest has been placed on the methods of acration control for management of maloders during composting. This study was performed to evaluate the influence of the intermittent aeration method on the composting temperature and chemical components. Combinatoins of cattle manure and rice hulls were placed on a batch composter(3,150-L size) practically designed. The chemical properties of the produced compost were suitable for plant growth, when composting temperature was maintained in the range from 45 to $66^{\circ}C$ for 42 days. It should be noted that cooling effect of intake air was not significant because air temperature was as high as $30^{\circ}C$. Heat and aeration loss from the composter did not affect biomass decomposition by microbes during composting. Mixtures of materials with C/N ratios higher than 30 required longer composting period.

  • PDF

실규모 연속유입간헐폭기 공정(ICEAS)에서 최적운전조건이 경제성에 미치는 영향 (Economic implications of optimal operating conditions in a full-scale continuous intermittent cycle extended aeration system (ICEAS))

  • 정용재;최윤성;이승환
    • 상하수도학회지
    • /
    • 제38권1호
    • /
    • pp.29-38
    • /
    • 2024
  • Wastewater management is increasingly emphasizing economic and environmental sustainability. Traditional methods in sewage treatment plants have significant implications for the environment and the economy due to power and chemical consumption, and sludge generation. To address these challenges, a study was conducted to develop the Intermittent Cycle Extended Aeration System (ICEAS). This approach was implemented as the primary technique in a full-scale wastewater treatment facility, utilizing key operational factors within the standard Sequencing Batch Reactor (SBR) process. The optimal operational approach, identified in this study, was put into practice at the research facility from January 2020 to December 2022. By implementing management strategies within the biological reactor, it was shown that maintaining and reducing chemical quantities, sludge generation, power consumption, and related costs could yield economic benefits. Moreover, adapting operations to influent characteristics and seasonal conditions allowed for efficient blower operation, reducing unnecessary electricity consumption and ensuring proper dissolved oxygen levels. Despite annual increases in influent flow rate and concentration, this study demonstrated the ability to maintain and reduce sludge production, electricity consumption, and chemical usage. Additionally, systematic responses to emergencies and abnormal situations significantly contributed to economic, technical, and environmental benefits.

공기 주입량 및 주입모드가 바이오벤팅의 처리효율에 미치는 영향

  • 박준석;안병구;류두현;신헌균;최민주;김영석;박종은
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.315-318
    • /
    • 2002
  • This study was performed to evaluate the effects of air flow rate and aeration mode on the treatment of bioventing for diesel-contaminated soil. Initial concentrations of diesel-contaminated soils were about 2,500 and 9,000mg/kg. Air flow rates were 30, 60, and 100mL/min, and air was injected in the continuous and the intermittent modes. TPH removal efficiency of intermittent aeration mode was higher than that of continuous aeration mode. Greater air flow rate than the value of guidance book was needed for bioventing.

  • PDF

저수지의 수질 관리를 위한 간헐식 양수통형 인공 순환 장치의 설계 방법 개발 (Design Methods of Intermittent Deep Draw Aeration System for Reservoir Water Quality Management)

  • 서동일;송무석;황현동;이은형
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.445-452
    • /
    • 2004
  • Intermittent deep draw artificial circulation system is one of the most widely used destratification systems to control algal bloom in reservoirs in Korea. However, there have been neither theoretical background of design criteria nor operation guide line for efficient application of the system available for such systems. A design method was developed to calculate required compressor capacity and number of circulation units considering physical interactions between stratified water layers and plumes induced by the intermittent deep draw artificial circulation system. The program was tested with data observed in Yeoncho Lake. The results indicated that the developed method can applied in the fields successfully. Further validation processes would improve design and operation methods.

암모니아 센서를 이용한 간헐폭기 Membrane bioreactor공정에서의 전력비 저감과 관형막을 이용한 슬러지 농축에 관한 연구 (A study on an intermittent aeration membrane bioreactor system using ammonia sensor to decrease energy consumption and sludge concentration by tubular membrane)

  • 강희석;이의종;김형수;장암
    • 상하수도학회지
    • /
    • 제28권2호
    • /
    • pp.161-170
    • /
    • 2014
  • It is essential to decrease energy consumption and excess sludge to economically operate sewage treatment plant. This becomes more important along with a ban on sea dumping and exhaustion of resource. Therefore, many researchers have been study on energy consumption reduction and strategies for minimization of excess sludge production from the activated sludge process. The aeration cost account for a high proportion of maintenance cost because sufficient air is necessary to keep nitrifying bacteria activity of which the oxygen affinity is inferior to that of heterotrophic bacteria. Also, additional costs are incurred to stabilize excess sludge and decrease the volume of sludge. There were anoxic, aerobic, membrane, deairation and concentration zone in this MBR process. Continuous aeration was provided to prevent membrane fouling in membrane zone and intermittent aeration was provided in aerobic zone through ammonia sensor. So, there was the minimum oxygen to remove $NH_4-N$ below limited quantity that could be eliminated in membrane zone. As the result of this control, energy consumption of aeration system declined by between 10.4 % and 19.1 %. Besides, we could maintain high MLSS concentration in concentration zone and this induced the microorganisms to be in starved condition. Consequentially, the amount of excess sludge decrease by about 15 %.