State Evaluation of Nutrient Removal in an Intermittent Aeration Process by Monitoring ORP & pH

ORP와 pH 측정에 의한 간헐폭기 고도처리 공정 제어의 평가

  • Ko, Kwang Baik (Division of Civil & Urban Engineering, College of Engineering, Yansei University) ;
  • Suh, Jun Suk (Department of Urban Engineering, The Graduate School, Yansei University)
  • 고광백 (연세대학교 공과대학 사회환경시스템공학부) ;
  • 서준석 (연세대학교 대학원 도시공학과)
  • Published : 2002.12.31

Abstract

In this study, to evaluate the applicability of ORP and pH as process control parameters for an intermittent aeration process, a 200L/d bench-scale plant was installed and operated for 90 days. It was fed with synthetic wastewater which contained $COD_{Cr}$ : 400mg/L, TN : 40mg/L and TP : 7mg/L. ORP & pH were measured on-line and compared with the variation of nutrient concentrations. As the results, both of the ORP and pH were able to monitor successfully nitrification and denitrification. Bending-points on the ORP curve and peak points on the pH curve corresponded to the termination of nitrification and denitrification. For P uptake and release, pH was the best indicator for performance evaluation. The aerobic pH apex was appeared when P uptake was accomplished and there was a relationship between the P release and pH variation. But the pH curve needed filtering because there were many noises on it. In this study, the shape of the ORP & pH curves were varied as the operating conditions such as aeration rates and organic loads were changed. It allowed the operating states of biological systems to be effectively evaluated. If it is properly managed to show the bending points and peak points clearly, the on-line monitoring of ORP & pH will be a reliable and effective technique for process control of intermittent aeration processes.

Keywords