• Title/Summary/Keyword: Interior-Exterior Control

Search Result 66, Processing Time 0.026 seconds

A Study on Characteristics of Liquid-Crystal Based Cell for Smart Window (액정 기반 스마트 윈도우용 셀의 특성 연구)

  • Park, Byung-Gyu;Kim, Sun-Keum;Lee, Seung-Woo;So, Soon-Yeol;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.271-275
    • /
    • 2020
  • Smart windows are used as windows and doors to determine the cooling and heating efficiency of a building. They have characteristics that can increase the energy efficiency of a building, which leads to energy savings. In addition, smart windows can control the amount of light transmitted from the external environment of a building to the interior of a building according to the needs of the user. In this study, a 297×210 ㎟ liquid crystal cell capable of controlling light transmittance was fabricated using a liquid crystal device as an optical shutter. The effect of driving voltage on the transmittance and the effect of the thermal environment on the driving stability were analyzed. We confirmed the applicability of using smart windows as exterior building materials.

Investigating Applicability of Unmanned Aerial Vehicle to the Tidal Flat Zone (조간대 갯벌에서 무인항공기 활용 가능성에 관한 연구 - 수치표고모델을 중심으로 -)

  • Kim, Bum-Jun;Lee, Yoon-Kyung;Choi, Jong-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.5
    • /
    • pp.461-471
    • /
    • 2015
  • In this study, we generated orthoimages and Digital Elevation Model (DEM) from Unmanned Aerial Vehicle (UAV) to confirm the accuracy of possibility of geospatial information system generation, then compared the DEM with the topographic height values measured from Real Time Kinematic-GPS (RTK-GPS). The DEMs were generated from aerial triangulation method using fixed-wing UAV and rotary-wing UAV, and DEM based on the waterline method also generated. For the accurate generation of mosaic images and DEM, the distorted images occurred by interior and exterior orientation were corrected using camera calibration. In addition, we set up the 30 Ground Control Points (GPCs) in order to correct of the UAVs position error. Therefore, the mosaic images and DEM were obtained with geometric error less than 30 cm. The height of generated DEMs by UAVs were compared with the levelled elevation by RTK-GPS. The value of R-square is closely 1. From this study, we could confirm that accurate DEM of the tidal flat can be generated using UAVs and these detailed spatial information about tidal flat will be widely used for tidal flat management.

Case Studies on Space Zoning and Passive Façade Strategies for Green Laboratories

  • Kim, Jinho
    • Architectural research
    • /
    • v.22 no.2
    • /
    • pp.41-52
    • /
    • 2020
  • Laboratory buildings with specialized equipment and ventilation systems pose challenges in terms of efficient energy use and initial construction costs. Additionally, lab spaces should have flexible and efficient layouts and provide a comfortable indoor research environment. Therefore, this study aims to identify the correlation between the facade of a building and its interior layout from case studies of energy-efficient research labs and to propose passive energy design strategies for the establishment of an optimal research environment. The case studies in this paper were selected from the American Institute of Architects Committee on the Environment Top Ten Projects and Leadership in Energy and Environmental Design (LEED) certified research lab projects. In this paper, the passive design strategies of space zoning, façade design devices to control heating and cooling loads were analyzed. Additionally, the relationships between these strategies and the interior lab layouts, lab support spaces, offices, and circulation areas were examined. The following four conclusions were drawn from the analysis of various cases: 1) space zoning for grouping areas with similar energy requirements is performed to concentrate similar heating and cooling demands to simplify the HVAC loads. 2) Public areas such as corridor, atrium, or courtyard can serve as buffer zones that employ passive solar design to minimize the mechanical energy load. 3) A balanced window-to-wall ratio (WWR), exterior shading devices, and natural ventilation systems are applied according to the space programming energy requirements to minimize the dependence on mechanical service. 4) Lastly, typical laboratory space zoning categories can be revised, reversed, and even reconfigured to minimize the energy load and adjust to the site context. This study can provide deep insights into various design strategies employed for construction of green laboratories along with intuitive arrangement of various building components such as laboratory spaces, lab support spaces, office spaces, and common public areas. The key findings of this study can contribute towards creating improved designs of laboratory facilities with reduced carbon footprint and greenhouse emissions.

Studies on Wood-based Composite Panel with Waste Tire - Properties of Composite Boards in Relation to Hot Pressing Conditions - (폐타이어를 이용한 목질계 복합판넬의 연구 - 열압조건에 의한 재질특성 -)

  • Lee, Weon-Hee;Park, Sang-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.29-38
    • /
    • 1997
  • The effect and control of wood property of reconstituted composite panels for improved board properties by wood-waste materials and development of combination method for heterogeneous materials have been of interest to the wood science researchers. The purpose of this study is to consider the properties in relation to hot pressing conditions and to develope the optimum hot pressing condition with waste wood and waste tire for the manufacturing of composite boards. The study of composite boards for recycling of wood and waste tire is nothing up to the present. Physical and mechanical properties such as specific gravity, moisture content, swelling coefficient, modulus of rupture and modulus of elasticity in bending test were studied. The condition of 3-stage press time for the lowest moisture content of composite board was $4{\rightarrow}3{\rightarrow}3$ minutes. Specific gravity of composite panels was affected mainly by the amount of rubber chip. Because of the low rigidity and high elasticity in rubber chip, it is considered the composite panel was adequate material in the place of compression load, but not bending load. Therefore, it was concluded that a use of rubber-based wood composite panel is proper to the interior materials such as floor a room than exterior materials. From the test results, the most optimum hot pressing conditions were $4{\rightarrow}3{\rightarrow}3$ minutes for 3-stage press time and $45{\rightarrow}20{\rightarrow}5kg/cm^2$ for 3-stage press pressure. The rubber-based wood composite panel was very excellent in elasticity by combination of rubber chip in comparison with existing other wood-based materials. Therefore, it was considered that rubber-based wood composites can be applicable to every interior materials such as floor a room and will be expected to effective reuse and recycle of waste tires and wood-waste materials, and will be contribute to protection of environment pollution in earth.

  • PDF

Analysis of Temperature and Total Heat of Heated Glass through Experimental Measurement and Three-Dimensional Steady-State Heat Transfer Analysis (실측실험과 3차원 정상상태 열전달 해석을 통한 발열유리의 온도 및 전열량 분석)

  • Lee, Do-Hyung;Yoon, Jong-Ho;Oh, Myeong-Hwan
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.111-116
    • /
    • 2015
  • Heat loss from windows and condensation occuring on its surface due to its lower insulation value causes much discomfort to occupants. In this study, Heated glass was used to make a basic study on prevention of condensation on glass surface for its heating functionality through experimental measurement and simulation analysis of total heat flux on the interior and exterior surface of glass. Error between experimental results and three dimensional steady-state heat transfer analysis were caused firstly, beacuse in the experimental chambers, cold chamber and steady temperature and humidity chamber, air temperature setting was not constant but rather ON/OFF control, and secondly, due to error rate in heat flux meter due to heat flux direction even in stable conditions.

Simulation of displacement history using contact element in traditional wooden frame (접촉요소를 적용한 전통목조 도리방향 프레임의 변위이력 시뮬레이션에 관한 연구)

  • Hwang Jong-Kuk;Hong Sung-Gul;Jung Sung-Jin;Lee Young-Wook;Kim Nam-Hee;Bae Byoung-Sun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.421-426
    • /
    • 2006
  • To examine the behaviors of traditional wooden structural frame in Korea in direction of beam, an experimental study was performed. The interior frame of Daewoongjeon of Bongjeongsa was selected as a model, which has two short exterior columns and one high inside column. The experimental frame has 1/2 scale and lateral forces are applied at high inside column by using drift control. The vertical gravity loads are applied on the frame. From the results of experiment it was shown that the stiffness and lateral capacity of the frame was increased when vertical loads are applied and the force-drift relationship in positive load direction was not same as in negative load direction. And push-over analysis are performed by using macro model in which the rotational and shear springs which were derived from the another experiments of subassemblies were used. The numerical analysis with macro model showed a good correspondence with the experiment within 2% story drift.

  • PDF

A study on application of an E/V shaft cooling system to reduce the stack effect in high-rise building (연돌효과 저감을 위한 E/V샤프트 냉각장치의 적용에 대한 연구)

  • Lim, Hyun-Woo;Lee, June-Ho;Seo, Jung-Min;Lee, Jung-Hun;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.284-292
    • /
    • 2009
  • The stack-effect in high-rise buildings in winter causes many problems such as difficulties in opening or closing doors, infiltration, energy loss, noise and fire protection. Stack effect is influenced by temperature difference between the interior and exterior of building and the height of building. As an attenuation method for stack effect, the architectural methods are generally used. However, as though architectural methods were fully adopted, the problems are reported as ever in tall building. In this study, a new method to reduce stack effect will be suggested. As an active control method against the stack effect, E/V shaft natural cooling method is suggested. In this paper, the concept of E/V shaft natural cooling system and its reduction performance of stack effect by simulation and field measurement will be reported.

  • PDF

Studies on Physical Properties of Wood-based Composite Panel with Recycled Tire Chip - Change of Properties on Composite Panel by Mixing Ratio of Combined Materials - (폐타이어를 이용한 목질고무 복합패널의 물성에 관한 연구 - 원료혼합비율에 따른 복합패널의 재질변화 -)

  • Lee, Weon-Hee;Byeon, Hee-Seop;Bae, Hyun-Mi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 1998
  • In this paper, the relationships between volumetric mixing ratio of rubber chip and physical and mechanical properties of wood/rubber composite panel was examined in order to investigate the mixture characteristics of wood and rubber chip. Because of the specific gravity of rubber differed from wood chip, physical properties of wood/rubber composite panel was shown very different values by mixing rate of chip element. Specific gravity in air-dry of composite panel was increased rapidly as volumetric percent of rubber chip was increased. Moisture content of composite panel was decreased as volumetric percent of rubber chip element was increased. This results was considered that wood weight is light and porosity material for moisture absorption. Compressive strength and modulus of rupture in bending test were decreased as volumetric percent of rubber chip increased. By mixing ratio control of chip elements, various wood/rubber composite panel can be applicable to every interior materials such as subfloor, playground, and exterior materials such as road blocks for recreational facilities in garden and forest and city parks.

  • PDF

Development of Heat Pump System for High Efficiency Engine Vehicle (고효율엔진 차량 히트펌프 시스템 개발)

  • Park, Byung-Duck;Won, Jong-Phil;Lee, Won-Suk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • As DDI or GDI engine discharges very low heat due to its high thermal efficiency, the heat source is not enough for heating the passenger compartment in cold climate condition. To remedy the heating problem, the conventional HFC-134a automotive air-conditioning system has been attempted to run as a heat pump mode. Futhermore, an auxiliary electric heater of new type was equipped to the heat pump air-conditioning loop as a new approach. Hence, a proto-type heat pump air conditioner has been made and tested to investigate the feasibility of the HFC-134a automobile air-conditioning system that could be worked as a heat pump. The experiment results showed that the sufficient heating capacity could be obtained by adding a heat pump with an new electric type auxiliary heater into the conventional heat core in low temperature condition.

  • PDF

Influence of Psychological Well-being on Highschool Student's Emotional intelligence and Interior-Exterior Control (고등학생의 심리적 안녕감이 정서지능과 내외통제성에 미치는 영향)

  • Lee, Kyung-Mee;Park, Jung-Hwan;Kim, Young-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.74-77
    • /
    • 2011
  • 본 연구는 고등학생의 심리적 안녕감이 일상생활을 함에 있어서 대표적인 적응 지표로서 기능하는 정서지능과 어떠한 관련성이 있는지 알아보고, 또한 심리적 안녕감이 고등학생들의 내외통제성에는 어떠한 관련성이 있는지 살펴보는데 목적이 있다. 본 연구는 제주시 고등학교 학생 402명을 대상으로 하였다. 연구 결과는 다음과 같다. 첫째, 심리적 안녕감과 정서지능과는 상관관계를 나타냈다. 둘째, 심리적 안녕감과 내외통제성과는 상관관계를 나타냈다. 셋째, 심리적 안녕감이 정서지능에 긍정적 영향을 미치고 있는 것으로 나타났다. 넷째, 심리적 안녕감이 내외통제성에 긍정적 영향을 미치고 있는 것으로 나타났다. 이러한 연구결과로 볼 때, 심리적 안녕감과 정서지능과는 높은 관련성이 있다. 또한 심리적 안녕감이 높을수록 자신의 선택한 결과를 외부의 환경에 두는 것이 아니라 자신의 능력, 노력 등으로 귀인하는 내외통제성과도 관련이 있다. 따라서 고등학생의 정서지능을 함양시키는 프로그램들이 개발되어져야 한다고 사료된다.

  • PDF