• Title/Summary/Keyword: Interior air quality

Search Result 114, Processing Time 0.032 seconds

Actual Use Pattern of Environment-friendly Finish Materials in Recently-Constructed and Remodeled Apartment Houses (공동주택 유형별 친환경 마감재 사용 실태분석 연구)

  • Lee, Ji-Soon
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 2011
  • The concepts of interior design work have set forward an aesthetic and functional proposition to be answered by those who design spaces. The available range of suitable materials for interior use appears to be almost inexhaustible in this day and age. Now a day, relatively new fields of study on environmental-friendly interior examine humans'innate affinity for health and explore its implications for architecture and the built environment. A growing field of research suggests that spaces' relationship to aesthetics and environment can either help or hinder their occupants' health and wellness, productivity, and even their creativity. This paper presents several examples of already built apartment houses in practice, and discusses the demand of users of the spaces for health and sustainable environment, deepening the relationship between newly-constructed spaces and the remodeled ones. The considerations to some new and contemporary materials from the aspect of healthy indoor architecture design are presented in this paper. Designers need to rethink the conventional and high-tech interior environment in apartment houses with respect to perceived air quality, material emissions, and odors. The future of interior design is oriented on light shapeable materials which are able to create a unique memorable atmosphere. The primary assignment in accepting recent materials and proceedings is our responsibility to creating proposals, that are mainly safe, hygienic and environmentally proper.

A Study on the Calculation of Ventilation Rate in Apartment House according to VOCs and HCHO Substances of Building Material and Furniture (건축 마감재와 가구재의 VOCs, HCHO 유해물질에 따른 공동주택 적정 환기량 산정에 관한 연구)

  • Choi Jeong-Min;Park Jin-Seok;Son Young-Hwan;Park Chang-Sub;Park Min-Yong;Lee Kyung-Hee
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.101-108
    • /
    • 2005
  • Because of the airtightness of building, misuse of building materials and abuse of furniture, indoor air pollution problems have been increasingly concerned especially with apartment buildings. To improve the IAQ(Indoor Air Quality) in apartment building, this study was aimed at analyzing the factor of interior building material and furniture and calculating the ventilation rate of living room and bed room according to the surface area of interior building material and furniture in terms of VOCs(Volatile Organic Compounds) and HCHO(Formaldehyde). The results of this study are as follows; 1) In the concerned rooms, the living room has less pollution emission rate L(surface area/volume) than that of the bed room but, the living room needs more ventilation rate than that of the bed room because of built-in furniture in terms of VOCs and HCHO. 2) Built-in interior furniture is very important factor in IAQ problems of apartment building, but until now there is no provision about the built-in furniture, so that the provision must be regulated to control the IAQ. 3) To control the IAQ problem, the effective ventilation plans must be established according to the required ventilation rate by means of natural or mechanical ventilation method.

Carbon dioxide (CO2) concentrations and activated carbon fiber filters in passenger vehicles in urban areas of Jeonju, Korea

  • Kim, Hong Gun;Yu, Yunhua;Yang, Xiaoping;Ryu, Seung Kon
    • Carbon letters
    • /
    • v.26
    • /
    • pp.74-80
    • /
    • 2018
  • The South Korean Ministry of the Environment has revised the laws relating to the management of interior air quality for multiple use facilities, and recommends maintaining carbon dioxide ($CO_2$) concentration in passenger vehicles below 1000 ppm during operation in urban areas of large cities. However, the interior $CO_2$ concentration of passenger vehicles can rapidly increase and exceed 5000 ppm within 30 min, as observed when two passengers are traveling in urban areas of the South Korean city of Jeonju with the air conditioner blower turned off and the actuator mode set to internal circulation mode. With four passengers, $CO_2$ concentration can reach up to 6000 ppm within 10 min. To counter this, when the actuator is set to external mode, $CO_2$ concentration can be maintained below 1000 ppm, even after a long period of running time. As part of the air conditioning system, alkali-treated activated carbon fiber filters are considered to be far superior to the commercial non-woven filters or combination filters currently commonly in use.

A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum (박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구)

  • Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.

A study on the finishing materials for Reduction of Indoor pollution (실내 환경오염 감소를 위한 건축마감 재료에 관한 연구)

  • Kim, Ja-Kyung;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.303-313
    • /
    • 2007
  • Nowadays, according to many studies, indoor space's pollution level is two to ten times higher than outdoor space's. This result arouses our attention. The major causes of deterioration of indoor air quality are the lack of ventilation caused by draught-proofing and insulation construction, and harmful chemical substances emitted from building materials, office machine and furniture. Therefore, we are continuing research to find the method for healthful house and production of many forms of well-being goods. However, because of exaggerated advertisements and the lack of accurate information, consumers choose the products whose performance is not verified. Therefore, this study investigates the actual conditions of pollution by building materials and the extent of the health damage by this pollution, and suggests the method for minimizing indoor pollution in aspect of indoor environment control and the use of environment friendly materials. But the building materials presented in this study are limited to the environment friendly construction materials that are in circulation In domestic market because this research is primarily aimed to give domestic consumers the standard for selecting this materials.

Study to improvement of the interior comfort in the Tilting train (틸팅열차 실내 쾌적성 향상 연구)

  • Kim, Hyun-Shik;Jang, Chang-Yun;Jang, Jae-Seung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1243-1248
    • /
    • 2009
  • This paper introduces the methode to improve the indoor air quality for Korea Tilting train express(TTX). TTX operates more than 80,000km in commercial line and in the near future service is expected. To improve air quality effective heat and cooling system is proposed. Also according to the ministry of environment guide line, major factor component are selected to Co2(carbon dioxide) and Pm10(particle matter). The database of the vital factor was accumulated by the various case of operation environment. Finally, optimal air condition controling device is developed and installed.

  • PDF

Formaldehyde Deodorization Effect and Far-Infrared Emission Characteristics of Ceramics Prepared with Sawdust, Risk Husk, and Charcoal: Effect of Material Mixing Ratio

  • HWANG, Jung-Woo;OH, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.2
    • /
    • pp.104-112
    • /
    • 2022
  • Indoor air quality is a very important environmental factor in modern society. However, air pollutants generated from various interior construction materials significantly affect the human body, including formaldehyde (HCHO) and volatile organic compounds that threaten public health by deteriorating indoor air quality. Effective in removing these harmful substances are porous materials, such as woodceramics. In this study, charcoal, a porous material, was added to rice husk, an agricultural by-product, and sawdust generated during the sawing process to prepare boards and ceramics at different mixing ratios, and the HCHO deodorization performance and far-infrared emission characteristics were measured. As the mixing ratio of charcoal increased, the deodorization rate of the boards and ceramics tended to increase. Overall, the deodorization rate was measured to be 80% to 90%, indicating that the boards and ceramics prepared with charcoal are suitable to be used for the purpose of deodorization. The effect of the material mixing ratio on far-infrared emissivity and emission power was insignificant.

A Study on Indoor Environment Quality in Office Building (오피스 빌딩 실내환경의 질에 관한 연구)

  • Lee, Kyeong-Hee;Ha, Mi-Kyoung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.259-263
    • /
    • 2006
  • The purpose of this study is to assess the characteristics of self-reported symptoms of workers in office building with HVAC system, and also to provide better workplaces in terms of comfort and health. The methods employed in this study include literature review, field observations, and survey. The self-reported symptoms of workers such as headache, fatigue, itching and dryness regarded as SBS symptoms commonly occur after around 3:00 pm and are relieved after leaving their office buildings. according to results in previous studies, above are possibly related to CO2 concentrations. It is also found work environment factors and the satisfaction on indoor environment are all associated with worker's health. Hopefully, this overview of current work environments concerning the level of satisfaction and health problems of workers would help create healthier indoor environment.

  • PDF

A Study on the Awareness and Needs of Employees in Office Work Environment -Focused on Pusan and Kyoungnam Area- (업무환경에 대한 이용자의 의식 및 요구에 관한 연구 -부산 및 경남지역 중심으로-)

  • 손광호
    • Korean Institute of Interior Design Journal
    • /
    • no.13
    • /
    • pp.96-101
    • /
    • 1997
  • The purpose of this study was to examine the current office work environment and suggest the needs for improvement the quality and efficiency of work. To fulfill this task, information describing various environmental conditions was gathered from generally large offices in Pusan and Major cities in Kyoungnam. Data were collected on questionnaire's general information, lighting, air quality, temperature, health problems, noise and equipment arrangements, and the size fo workspace. The extent to which the attitudes and behaviors of workers were related to these environmental conditions was then examined and scrutinized. According to the development of office automation, the interest in improvement of office environment become increased. Workstation size, individual environmental control, health care, adequate storage space and noise control should be recognized as critical to the worker's environmental satisfactiov. Finally, based on the results of this study, a number ofrecommendations can be made for alleviating some of the problems that have been identified. Designers should be interested in knowing if their environments actually function in the manner in which they were intended.

  • PDF

Evaluation of volatile organic compounds emitted from door-trim armrest using micro chamber and 20 L static chamber (마이크로 챔버와 20 L static chamber를 이용한 도어트림 암레스트로부터 방출되는 휘발성 유기화합물 평가)

  • Lee, Ik-Hee;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.290-297
    • /
    • 2011
  • In present, evaluation method for car cabin air quality has been developed in ISO, China, Japan. Also The management standard for new produced car has been applied since 1, July, 2010. To manage car cabin air quality, It is important to evaluate VOC emitted from interior material. In this study, complete component of door trim armrest was evaluated in accordance with ISO 12219-5, cut component was evaluated in accordance with ISO 12219-3. The vapour gas was collected with stainless tube packed with Tenax TA and analyzed with TD-GC/MS. It was confirmed that emission rate of each compounds was difficult in each evaluation method. As a result, to evaluating each components composing door trim armrest, main sources of emitting VOCs in door trim armrest were PP substrate and adhesive.