• Title/Summary/Keyword: Interior Temperature

Search Result 486, Processing Time 0.023 seconds

A Study of Indoor Thermal and Air Quality in Middle and High School Classrooms during Winter (겨울철 학교교실의 실내열.공기환경 실태와 학생들의 주관적 반응)

  • Choi, Yoon-Jung;Na, Sun-Hee;Jo, Su-Youn
    • Korean Journal of Human Ecology
    • /
    • v.18 no.2
    • /
    • pp.509-522
    • /
    • 2009
  • This is a basic study to improve air quality of school classrooms in winter time. The purposes are to check indoor thermal and air environment in school classrooms during winter and to analyze influencing factors on indoor environment. The measurements of students' physical elements with questionnaire surveys were carried out in a total of 6 classrooms. As a result, this research shows that the temperature of one classroom was below indoor thermal standard level, three classrooms had lack of heat, and two classrooms are heated much, which induce relatively low humidity. All of 6 classrooms had lack of ventilation, being high level of $CO_2$ concentration and 2 classrooms are in condition of high PM10 concentration. The majority of students(76%) answered that the cause of their 'heated space syndrome' is because of the lack of ventilation. Students' opening windows for ventilations is hardly carried out at normal times, except that indoor temperature is over standard. That is, we can suggest one of solutions, which is to enable students to operate heating and ventilating system by themselves according to students' physical condition.

Phase Changes of Pure Ti During High Temperature Gas Nitriding (순 Ti의 고온 가스질화에 따른 미세조직 변화)

  • Lee, H.J.;Kong, J.H.;Bae, J.B.;Seo, J.H.;Kim, Y.H.;Sung, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.2
    • /
    • pp.88-94
    • /
    • 2009
  • The effect of high temperature gas nitrding (HTGN) on the surface microstructure in pure Ti was investigated. Two phases of TiN and $Ti_2N$ appeared at the outmost surface, and the wide ${\alpha}$-Ti layer was formed at the next layer. On the other hand, the interior region, where the nitrogen was not permeated, exhibited ${\alpha}$'phase. The outmost surface of TiN and $Ti_2N$ showed the maximum hardness of 1000Hv, while the interior ${\alpha}$'phase was ${\sim}350$ Hv. The permeation depth of nitrogen increased with increasing the gas nitriding temperature and time. The nitrogen concentration of the surface layer seems to be over 12.7% at $1100^{\circ}C$.

Numerical analysis of temperature and stress distributions in a prestressed concrete slab with pipe cooling (파이프쿨링을 실시한 대형 프리스트레스트 콘크리트 슬래브의 수화열 해석)

  • 주영춘;김은겸;신치범;조규영;박용남
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.275-280
    • /
    • 1999
  • It was analysed the effect of pipe cooling as a measure to avoid thermal cracks due to the heat of hydration during the curing process of a massive prestressed concrete (PSC) slab. PSC slab has a complex three-dimensional shape of which the maximal and minimal thicknesses of cross-section were 2.8 and 0.95m, respectively. Steel pipes of which the diameter was 1 inch were employed for cooling. The horizontal and vertical distances between the contiguous pipes were 0.5 and 0.6m, respectively. One the four layers of cooling pipe were arranged according to the thickness of cross-section. Temperature distribution was calculated by the program developed by the authors, of which the accuracy was verified on a few published papers by the authors. Based on the temperature analysis of the cross-section which had four layers of cooing pipe, the maximum temperature of concrete interior was 54.2$^{\circ}C$ and the maximum differenced between the interior and surface temperatures of concrete was 14.$0^{\circ}C$ and, thereby, the thermal cracking index was 1.1. Upon the stress analysis, the thermal cracking index was 0.92 and the probability of thermal-crack development was 52%. Therefore, it was expected to make it possible to reduce the probability of thermal-crack development in a massive PSC slab by adopting pipe cooling.

  • PDF

Estimation of Strength and Pore Structure of Alkali-Activated Fire Protection Materials at High Temperature (고온에서의 알칼리 활성화 내화성 결합재의 강도 및 공극구조 평가)

  • Song, Hun;Kim, Young-Ho;Kim, Wan-Ki;So, Hyung-Suk
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.4
    • /
    • pp.59-66
    • /
    • 2012
  • This study is interested in identifying the effectiveness of alkali-activated fire protection material compounds including the alkali-activator such as potassium hydroxide, sodium silicate and fly ash as the fire resistant finishing materials. Also, this paper is concerned with change in compressive strength and pore structure of the alkali-activated fire protection material at high temperatures. The testing methods of fire protection materials in high temperature properties are make use of TG-DSC and mercury intrusion porosimetry measurements. This study results show that compressive strength is rapidly degraded depending on a rise of heating temperature. Porosity showed a tendency to increase irrespective of specimen types. This is due to both the outbreak of collapse of gel comprising the cement and a micro crack by heating. However, alkali-activated fire protection material composed of potassium hydroxide, sodium silicate and fly ash has the thermal stability of the slight decrease of compressive strength and porosity at high temperature. These thermal stability is caused by the ceramic binding capacity induced by alkali activation reaction by the reason of the thermal analysis result not showing the decomposition of calcium hydrate.

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

Manufacture of Soluble Micro-fiber and Low Melting Polymer for Interior Synthetic Leather (인테리어용 인조가죽을 위한 용출형 극세사와 저온 융착사의 제조)

  • Ahn, Young-Moo
    • Korean Journal of Human Ecology
    • /
    • v.12 no.4
    • /
    • pp.529-537
    • /
    • 2003
  • This study was conducted to manufacture the soluble micro-fiber and to synthesize low melting polymer for the interior fabric not to use the polyurethane resin causing some problems. Low melting polyester for weft yarn was introduced by adding 30-40 mol% ratio of isophthalic acid to a main chain of polyethylene terephthalate to decrease the melting temperature up to heat setting temperature. Micro-fiber for warp yarn consisted of both soluble and insoluble components with multi-layered structure. When the soluble micro-fiber was treated by alkaline hydrolysis with 3-5% concentration of NaOH, it showed the turning point at 28% weight loss since soluble polyester was hydrolyzed approximate five times faster than regular polyester.

  • PDF

A Study on the Actual Conditionis and Improvement Plan of Interior Landscape in the Subway Stations (지하철역내의 실내조경현황과 개선방안에 관한 연구)

  • 방광자;주진희;박혜경;박성은
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.3
    • /
    • pp.258-266
    • /
    • 1998
  • The purpose of this study is to investigate the actual conditions, to find problems, and to present an improvement plan of interior landscape in the subway stationis. Moreoiver, it will presume the possibilties to develop the subway and ways to utilie underground space effectively. The results are summarized as follows A light intensity was recorded 0-100 Lux as the lowest light and 500 Lux below as the highest in 61 subway stations. An average temperature of 12 $^{\circ}C$and an air humidity of 38% were recorded over a 4 month period from January to April, but includes a drastic variaton between -8.5$^{\circ}C$ and 21.5$^{\circ}C$. Soil acidity of pH 7 below and soil moisture of 1-2 wet degree were apeared in subway stations mostly. Plant forms consisted of artificial flower & flower. Plant species were recorded at a total of 54 species and appeared in the order of Araucaria heteropylla, Ophiophogon jaburan, Aspidistra elatior cv. 'Asahi' and Hedera helix. Plant height was, for the most part, below 0.5m. Plant species that was fined of conditions were Palm, Camellia japonica, Araucaria heterophylla as a high plant, dracaena fragrans, dracaena deremensis cv. Wakneckii as a middle plant, and Ophiopogon jaburan, Hedra helix, ytomium falcatum, Aspidistra elatior cv. Asahi as a low plant. It used to water materials such as small pool, small cascade, water cycles and natural materials such as natural rock, small rock, sand, bark and animal materials such as squirrels, birds, goldfish as an object for plants in the subway stations. From these actual conditions, First of all, It must make up physical environments such as light, temperature humidity, soil for plant growth, and is important to chooce suitable indoor plants and draw up systematic management in the subway environments. Also, it change plants frequently and uses variable objects for subway stationi individuatism, Moreover, indoor plants with strong environmental adaptation abities such as shade tolerance, drought tolerance and cold tolerance need to develope variable species possibly. If these improvements occur, utilization and amenity of subway stationis will increase, according to the use of interior landscape.

  • PDF

Analysis of Back EMF and Torque in Interior Permanent Magnet BLDC Motors (INTERIOR 영구자석 BLDC MOTOR의 역기전압과 토오크에 관한 분석)

  • Sung, Bu-Hyun;Ku, Ja-Nam;Kim, Chang-Jun;Lee, Jin-Won;Kim, Sung-Min;Bae, Gun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.877-879
    • /
    • 1995
  • In this study, we developed the efficient brushless DC motor for a compressor of air conditioner. The characteristics of motor are under the control of the material of some parts and the shape of magnet. Especially we compared the interior shape to the surface shape of the magnet. And we optimized the parameters like the temperature and the materials of magnet and core by tool for more efficient motor.

  • PDF

A Study on Hybrid Living Space in Digital Architecture (디지털건축에서 추구하는 하이브리드한 주거공간에 관한 연구)

  • 이철재
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.289-296
    • /
    • 2001
  • Changing demographics, changing lifestyles. An international group of architects designs the homes of the future in places diverse as USA, Japan, South America and Europe. These architecture are also challenging the traditional structure of the private house, as we know it. Many of these architects are reinterpreting the private house, challenging traditional notions of what makes house. Here, the interior and exterior surfaces are transformed into 'smart skins', which blur the distinction between the digital and the real and become a part of the daily life of the occupants. The smart house will make possible amazing things we though existed only in science fiction, guarding or welfare, guessing our moods and catering to our demands in music, movies, temperature and ambience. And new materials will further transform our living areas.

  • PDF

A study on color planning appropriate for residential space (주거공간의 색채 계획에 대한 공간별 비교분석에 관한 연구)

  • Ha, Mi-Kyeong;Shin, Sun-Joo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.11a
    • /
    • pp.79-83
    • /
    • 2007
  • The demand for residential space is encompassing diverse ranges to keep pace with the times. Due to the Increase in wealth, people today want more functional and physical well being as well as giving more weight to the emotional aspect in spatial planning. This study paid special attention on the psychological effect of color--especially difference of warm/cold temperature--and the individual variation on favorable colors. 1. For a communal space (e.g. living rooms), subjects showed high preference of YR range of colors and warm colors. 2. For an individual space (e.g. bedrooms), subjects showed high preference of GY range of colors and neutral colors. 3. For a sanitary space (e.g. bathrooms), subjects showed high preference of PB and B ranges of colors, and cold colors. 4. For all of the above spaces, subjects showed high preference of warm colors.

  • PDF