• 제목/요약/키워드: Interference screw

검색결과 60건 처리시간 0.026초

진구성 아킬레스 건 파열에 대한 단일 절개 술식을 통한 건이전술 및 재건술 (Reconstruction of Neglected Achilles Tendon Rupture with Flexor Hallucis Longus Augmentation Using One Incision Technique)

  • 박광환;김범수;이진우
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.23-27
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the clinical outcome of neglected Achilles tendon rupture treated with reconstruction and augmentation with flexor hallucis longus (FHL) tendon using one incision technique. Materials and Methods: Between July 2006 and March 2008, eleven patients with neglected Achilles tendon rupture received surgical treatment. Through one incision technique, augmentation with auto FHL tendon transfer was performed using a Bio-Interference screw (Arthrex, Naples, FL) and followed by V-Y advancement (5 cases) or gastronemius fascial turn-down flap procedure (6 cases). After mean follow up of 20.7 months (range, 11.8-33.3 weeks), clinical outcomes were evaluated with Visual Analogue Scale (VAS), American Orthopedic Foot and Ankle Society (AOFAS) score, 10 repetitive double heel raise test, 10 repetitive single heel raise test and subjective satisfaction. Results: The length of the gap after debridement was $5.4{\pm}2.0$ cm. The VAS improved from $4.1{\pm}0.9$ to $1.5{\pm}0.8$ at last follow up (p<0.05). The AOFAS score increased from $38.9{\pm}12.2$ to $91.5{\pm}8.9$ at last follow up (p<0.05). Eight patients were satisfied with excellent results and three were satisfied with good results. All patients were able to perform 10 repetitive double heel raise and nine out of eleven patients were able to perform 10 repetitive single heel raise at last follow up. There were no complications including deep infection or re-rupture. Conclusion: Augmentation with FHL tendon transfer and reconstruction with V-Y advancement or turn-down flap through one incision technique appeared to be effective and safe. This technique is recommendable for the treatment of neglected Achilles tendon rupture.

  • PDF

Change in Turning Ability According to the Side Fin Angle of a Ship Based on a Mathematical Model

  • Lee, WangGook;Kim, Sang-Hyun;Jung, DooJin;Kwon, Sooyeon
    • 한국해양공학회지
    • /
    • 제36권2호
    • /
    • pp.91-100
    • /
    • 2022
  • In general, the effect of roll motion is not considered in the study on maneuverability in calm water. However, for high-speed twin-screw ships such as the DTMB 5415, the coupling effects of roll and other motions should be considered. Therefore, in this study, the estimation of maneuverability using a 4-degree-of-freedom (DOF; surge, sway, roll, yaw) maneuvering mathematical group (MMG) model was conducted for the DTMB 5415, to improve the estimation accuracy of its maneuverability. Furthermore, a study on the change in turning performance according to the fin angle was conducted. To accurately calculate the lift and drag forces generated by the fins, it is necessary to consider the three-dimensional shape of the wing, submerged depth, and effect of interference with the hull. First, a maneuvering simulation model was developed based on the 4-DOF MMG mathematical model, and the lift force and moment generated by the side fins were considered as external force terms. By employing the CFD model, the lift and drag forces generated from the side fins during ship operation were calculated, and the results were adopted as the external force terms of the 4-DOF MMG mathematical model. A 35° turning simulation was conducted by altering the ship's speed and the angle of the side fins. Accordingly, it was confirmed that the MMG simulation model constructed with the lift force of the fins calculated through CFD can sufficiently estimate maneuverability. It was confirmed that the heel angle changes according to the fin angle during steady turning, and the turning performance changes accordingly. In addition, it was verified that the turning performance could be improved by increasing the heel angle in the outward turning direction using the side fin, and that the sway speed of the ship during turning can affect the turning performance. Hence, it is considered necessary to study the effect of the sway speed on the turning performance of a ship during turning.

Leksell Frame-Based Stereotactic Biopsy for Infratentorial Tumor : Practical Tips and Considerations

  • Tae-Kyu Lee;Sa-Hoe Lim;Jangshik Jeong;Su Jee Park;Yeong Jin Kim;Kyung-Sub Moon;In-Young Kim;Shin Jung;Tae-Young Jung
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권2호
    • /
    • pp.249-256
    • /
    • 2024
  • The Leksell frame-based transcerebellar approach was proposed with the arc support frame attached upside down to the Z coordinate. This study presented practical tips and considerations for obtaining adequate tissue samples for deep-seated cerebellar lesions or lower brainstem lesions specifically those accessible via the cerebellar peduncle. For practical insights, the Leksell coordinate frame G was fixed to prevent the anterior screw implantation within the temporalis muscle, to avoid interference with the magnetic resonance (MR)-adapter, and taking into account the magnetic field of MR in close proximity to the tentorium. After mounting of indicator box, the MR imaging evaluation should cover both the indicator box and the infratentorial region that deviated from it. The coordinates [X, Y, Za, Arc0, Ringa0] obtained from Leksell SurgiPlan® software (Elekta, Stockholm, Sweden) with arc 00 located on the patient's right side were converted to [X, Y, Zb=360-Za, Arc0, Ringb0=Ringa0-1800]. The operation was performed in the prone position under general anesthesia in four patients with deep cerebellar (n=3) and brainstem (n=1) tumors. The biopsy results showed two cases of diffuse large B-cell lymphoma, one metastatic braintumor and one glioblastoma. One patient required frame repositioning as a complication. Drawing upon the methodology outlined in existing literature, we anticipate that imparting supplementary expertise could render the stereotactic biopsy of infratentorial tumors more consistent and manageable for the practitioner, thereby facilitating adequate tissue samples and minimizing patient complications.

전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과 (The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction)

  • 송은규;김종석
    • 대한정형외과스포츠의학회지
    • /
    • 제2권1호
    • /
    • pp.28-36
    • /
    • 2003
  • 목적: 전방십자인대재건술의성공에영향을미치는요인가운데수술후초기단계에는이식건에대한고정력이가장중요한인자로알려져있으며, 지금까지여러가지의고정방법들이사용되고있다. 저자는전방십자인대재건술후대퇴골측의초기안정성을알아보기위하여현재주로쓰이고있는6가지의고정방법들에대하여주기성인장부하검사를시행하기전,후의최대인장력을측정하여그결과를비교하고, 실패양상을관찰하고자하였다. 대상및방법: 돼지(Yorkshire) 슬관절72개를이용하여6가지고정방법(슬괵건-LA나사(R), 슬괵건-생체흡수성간섭나사, 슬괵건-Semifix 나사(R), 슬괵건-Endobutton(R)고정, 슬개건-티타늄간섭나사, 슬개건-생체흡수성간섭나사)으로이식건을고정하고 Instron(R) 인장검사기를이용하여주기성인장부하검사및최대실패인장력검사를시행하였다. 주기성인장부하검사는50 mm/min의속도로 30N에서 150N사이를1000회주기적으로반복하도록하였으며, 동일시편으로최대인장력검사를 시행하여주기성부하 후 최대 인장력의 변화를 비교, 분석하였다. 각 실험군에 따른 인장력 차이의통계적 유의성은ANOVA와Duncan 다중비교분석법을이용하였다. 결과: 주기성인장부하전,후이식건의최대인장력은슬괵건-LA나사(R) 군이평균1003.4$\pm$145N에서601.1$\pm$154N으로, 슬괵건-생체흡수성간섭나사군이평균 595.5$\pm$104N에서평균360.7$\pm$56N으로, 슬괵건-Semifix(R) 군이평균1431.7$\pm$135N에서평균710.7$\pm$114N으로, 슬괵건-Endobutton(R) 고정군이평균603.6$\pm$54N에서평균459.1$\pm$46N으로, 슬개건-티타늄 간섭나사군이평균 1067.4$\pm$145N에서평균 601.8$\pm$134N으로, 슬개건-생체흡수성간섭나사군이평균 987.1$\pm$168N에서588.7$\pm$124N으로각각40$\%$, 39$\%$, 50$\%$, 24$\%$, 44$\%$, 40$\%$가감소하였다. 결론: 수술후초기고정력은슬괵건을LA나사(R) 또는Semifix(R)로고정하는방법과슬개건을티타늄및생체흡수성간섭나사로고정하는방법등이우수하였으며, 슬괵건을생체흡수성간섭나사나Endobutton(R)으로 고정하는 방법 등은고정력이 상대적으로매우약함을 알수있었다. 최대인장력은단순인장검사로는이상의대퇴골측고정방법의고정력이초기부하를견뎌내는데충분하다고생각되었으나주기성부하실험후현저히감소되어충분한초기안정성을제공하지못함을알수있었다.

  • PDF

구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구 (A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY)

  • 김일규;박승훈;장금수;양정은;장재원;사시카라 바라라만
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권6호
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

실패한 임플란트 보철수복물을 가진 환자의 교합평면 재설정 (Re-establishment of occlusal plane in a patient with a failed implant prosthesis)

  • 강현구;고경호;허윤혁;조리라;박찬진
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.141-153
    • /
    • 2018
  • 계속적인 치아의 상실과 마모 및 보철물의 실패로 초래된 생리적이지 못한 교합평면은 비심미성, 저작 효율의 감소 및 교합 간섭와 같은 기능적인 문제을 야기할 수 있다. 따라서, 무치악 환자나 교합 평면이 붕괴된 환자의 보철 치료 시, 저작 기능과 조화로운 교합평면의 설정이 중요하다. 본 증례의 환자는 완전 무치악 상태인 상악을 임플란트 고정성 보철물로 수복하였다. 6년 경과 관찰 시, 기존 임플란트 보철물의 도재 파절, 마모, 나사풀림과 같은 기계적 합병증이 관찰되었고, 대합하는 전치의 마모 및 정출과 일부 구치부 치아의 상실로 인해 교합평면이 붕괴된 상태였다. 진단 과정을 거쳐 무치악 부위의 추가적인 임플란트 식립과 보철물의 재제작 및 모든 잔존 치아의 수복을 통해 전악구강회복을 시행하였다.

A safe, stable, and convenient three-dimensional device for high Le Fort I osteotomy

  • Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.32.1-32.4
    • /
    • 2020
  • Background: Le Fort I osteotomy is a highly effective treatment for skeletal jaw deformities and is commonly performed. High Le Fort I osteotomy is a modified surgical procedure performed for improving the depression of the cheeks by setting the osteotomy higher than the conventional Le Fort I osteotomy. Developments in three-dimensional (3D) technology have popularized the use of 3D printers in various institutions, especially in orthognathic surgeries. In this study, we report a safe and inexpensive method of performing a high Le Fort I osteotomy using a novel 3D device and piezosurgery, which prevent tooth root injury without disturbing the operation field for patients with a short midface and long tooth roots. Results: A 17-year-old woman presented with facial asymmetry, mandibular protrusion, a short midface, and long tooth roots. We planned high Le Fort I osteotomy and bilateral sagittal split ramus osteotomy. Prevention of damage to the roots of the teeth and the infraorbital nerve and accurate determination of the posterior osteotomy line were crucial for clinical success. Le Fort I osteotomy using 3D devices has been reported previously but were particularly large in size for this case. Additionally, setting the fixing screw of the device was difficult, because of the risk of damage to the roots of the teeth. Therefore, a different surgical technique, other than the conventional Le Fort I osteotomy and 3D device, was required. The left and right parts of the 3D device were fabricated separately, to prevent any interference in the surgical field. Further, the 3D device was designed to accurately cover the bone surface from the piriform aperture to the infra-zygomatic crest with two fixation points (the anterior nasal spine and the piriform aperture), which ensured stabilization of the 3D device. The device is thin and does not interfere with the surgical field. Safe and accurate surgical performance is possible using this device and piezosurgery. The roots of the teeth and the infraorbital nerve were unharmed during the surgery. Conclusions: This device is considerably smaller than conventional devices and is a simple, low-cost, and efficient method for performing accurate high Le Fort I osteotomy.

단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교 (A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.1003-1011
    • /
    • 2020
  • 본 연구는 듀얼 에너지 CT를 사용하여 금속인공물을 감소시키는 기법을 적용함에 있어 단일 선원과 이중 선원간의 영상 차이를 비교 평가하고자 한다. 단일 선원 장치로는 Discovery CT 256(GE, USA), 이중 선원 장치로는 Somatom Definition Flash(Siemens Health Care, Forchheim, Germany)를 이용하였다. 자체 제작한 팬텀(의료용 Titanium Screw를 삽입한 돼지다리)을 이중에너지 CT를 이용하여 동일 조건하에 선량을 변화시키며 영상을 얻은 후 정량적, 정성적 평가 하였다. 평가 방법으로는 뼈 주변, 조직 주변으로 나누고 금속삽입물로 인해 발생한 금속인공물(선속경화, 산란, 줄무늬)에 대하여 SNR을 측정하여 비교 분석하였다. 단일 선원 장치와 이중 선원 장치 간 금속 인공물 감소기법에는 영상의 차이가 있었다. 단일 선원 장치에서는 금속삽입물에 의한 선속경화 인공물이 이중 선원 장치에서 얻은 영상보다 많은 감소를 보이며 인공물의 방해 없이 주변 조직부가 잘 관찰 되었다. 이중 선원 장치에서는 금속삽입물에 의한 산란과 줄무늬 인공물이 단일 선원 장치에서 보다 많은 감소를 보이며 금속삽입물을 둘러싼 인접 조직들의 신호가 감소 없이 잘 관찰 되었다. 환자를 검사 시 보고자 하는 부위가 금속삽입물에 인접한 주변 조직이냐, 금속삽입물을 감싸는 전체적 조직이냐에 따라 단일 선원 장치와 이중 선원 장치를 구분하여 검사가 행해진다면 진단적으로 도움이 되는 영상을 획득할 수 있을 것으로 생각된다.

전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기 (New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL)

  • 하철원;어수익
    • 대한관절경학회지
    • /
    • 제6권2호
    • /
    • pp.195-199
    • /
    • 2002
  • 목적 : 전방십자인대 재건술시에 수술 수기가 크게 어려워지지 않으면서 전내측 및 후외측 다발을 각각 재건하고 별도로 긴장시켜 고정할 수 있는 수술 수기를 고안하여 재건슬을 시행한 결과, 해부학적 및 기능적으로 보다 정상에 가까운 전내측 및 후외측 다발의 긴장도를 갖는 전방십자인대 재건이 가능하였기에 그 수술 수기를 보고하고자 한다. 대상 및 방법 : 고식적인 관절 내시경적 전방십자인대 재건술과 동일한 기구를 사용하여 경골 및 대퇴골에 골터널을 만든다. 이때 경골부위의 골 터널이 일반적인 경우보다 약간 타원형이 되면서 약 $5\~7$ mm 정도 앞뒤 족으로 확장되도록 한다. 이식을 위한 동종 아킬레스건을 다듬을 때, 대퇴골 터널 내에 들어갈 골 부위는 고식적인 경우와 같도록 하고, 경골부 터널에 들어갈 건 부위는 가능한 한 두껍게 준비하고, Y자로 두 개의 다발로 만들어 각각 봉합사를 이용하여 마무리, 준비한다. 두 개의 다발을 함께 준비용 수술용 탁자의 터널 내로 통과시켜보면서 두께를 확인하고 대퇴골 터널 내에 동종 아킬레스건의 골 부위를 관절경 시야에 삽입시킨 후 고정한 다음, 경골 터널의 원위부 바깥쪽에서 두 개의 다발을 봉합사와 함께 당기면서 슬관절을 굴곡-신전을 반복하여 신장시킨다. 슬관절을 약 90도 굴곡한 상태에서 전내측 다발을 최대한 긴장시켜 post-tie 방법으로 고정한 후 다시 슬관절을 신전시킨 상태에서 후외측 다발을 최대한 긴장시켜 post-tie 방법으로 고정한다. 이후 2개의 다발사이로 끝이 둥근 유도핀을 삽입하여 관절경 시야에서 경골 터널 근위 입구에서 2개의 다발사이에 위치한 것을 최종 확인한 후, 흡수성 간섭나사를 이 핀을 따라 삽입하여 경골 터널 근위부 입구 직하부까지 전진시켜 좀더 견고한 고정을 얻으면서 전내측 및 후외 측 다발을 더욱 해부학적 위치에 자리잡을 수 있도록 한다. 연골 손상이 발생될 수 있다는 것을 염두에 두어야할 것으로 생각된다.있는 골 미성숙 환자의 전방 십자 인대 재건술은 하지부동이나 슬관절 정열이상이 없는 좋은 치료방법으로 생각된다.측에 발생하여 내측에 비해 많았으며 17례$(89.5\%)$에서 반월상연골 파열이 동반되었고 파열의 형태는 수평 파열이 15례$(79\%)$로 가장 많았다. 때, 이 두 집단 사이의 진단당시의 임상양상의 차이를 보면 고혈압, 단백뇨 및 부종의 빈도가 Group I에서 통계적으로 유의하게 증가되어 있으며, 임상병리검사 소견에서는 혈중 총단백량, 알부민, creatinine 청소율이 Group I에서 통계적으로 유의하게 감소되어 있고, BUN, creatinine은 통계적으로 유의하게 증가되었다. 결 론 : Alport 증후군 환아에서 임상적으로 유의미한 예후와 관련된 위험요인으로는 진단시의 고혈압, 부종, 단백뇨 유무 여부와 혈중 총단백량, 알부민, BUN, creatinine, 사구체 여과율이 중요하며, 이런 가능한 위험요인의 분석과 관찰이 Alport 증후군 환아의 치료와 예후 인지에 많은 도움이 되리라 사료된다. 상승은 주로 간에서 생성의 증가의 발생함을 알 수 있었다. 또한 지단백중 스테로이드를 사용하기전의 HDL cholesterol, apoB, apoB/HDL cholesterol등은 관해 유도기간과 의미 있는 양의 상관관계를 보여서 신증후군 환아의 재발을 예측 할 수 있는 지표로서 임상적인 의미를 부여할 수 있을 것이다. 또는 세포독성물질로도 스테로이드 의존성을 없애거나 재발율을 낮출 수 없었던 스테로이드 의존성 미세변화형 신증후군의 치료에서는 스테로이드 의존성 혹은 재발율의 변화를 나타내지 못하였다. 따라서 장기간의 MP 요법은 스테로이드 및 면역억제제 치료에 저항성을 보이는 1차성 또는 2차성 신증후군의 치료에

  • PDF

전방십자인대 재건술의 대퇴골 터널 굴착시 경경골 접근법과 전내측통로 접근법의 비교 (Comparision of Trans-Tibial and Anteromedial Portal Approach in Femoral Tunneling of Anterior Cruciate Ligament Reconstruction)

  • 손성근;장윤석;정일권;김경택
    • 대한관절경학회지
    • /
    • 제8권2호
    • /
    • pp.75-81
    • /
    • 2004
  • 목적: 전방십자인대 재건술시 대퇴골 터널의 등척점이 10시에서 10시 반 또는 1시 반에서 2시로 개념이 변함에 따라 전내측 통로를 이용한 대퇴골 터널 굴착방법의 유용성이 대두되고 있다. 이에 본 교실에서는 경경골 접근법과전내측 통로 접근법의 술기 및 술 후 방사선학적 계측을 비교하고자 하였다. 대상 및 방법: 2003년 1월부터 2004년 5월까지 본 교실에서 시행한 전방십자인대 재건술 100례 중 경경골 접근법을 이용한 50례(Croup 1) 및 전내측 통로 접근법을 이용한 50fii(Croup 11)를 대상으로 하였으며 수술방법 및 술후 결과를 방사선 촬영으로 비교하였다. 결과: 술기상으로 경경골 접근법을 이용한 경우에 비해 전내측 통로 접근법을 이용한 접근법은 10시에서 10시 반 또는 1시 반에서 2시의 등척점에 굴착하기가 용이하였고 100도의 굴곡으로 굴착하기 때문에 대퇴과간 절흔의 시야확보가 상대적으로 좋았으며 굴착시 후방피질골의 침습 위험도를 감소시킬 수 있었고 골터널과 이식인대 길이의 불일치를 감소시킬 수 있었다. 방사선학적으로 후자의 경우 전자에 비해 이식 인대골-간섭나사 각도의 감소(P<0.05)를 나타내었으나 대퇴터널과 경골터널이 이루는 각은 증가되어 있었다. 결론: 전방십자인대 재건술시 대퇴터널은 그 등척점이 우측의 경우 10시에서 10시 반, 좌측의 경우 1시 반에서 2시로 변화함에 따라 경경골 접근법보다 전내측 통로를 이용한 대퇴터널의 굴착방법이 유용할것으로 사료되며 대퇴터널 이식인대의 마모에 대해서는 술후 장기적인 추시관찰 및 추가적인 연구가 필요할것으로 사료된다.

  • PDF