• Title/Summary/Keyword: Interference field strength

Search Result 45, Processing Time 0.032 seconds

A study on the electric field strength of the insulation cover using 22.9 kV-y distribution line (22.9 KV-y 배전선로용 전선보호관 전계강도 비교실험 연구)

  • Chon, Y.K.;Seo, K.S.;Cha, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1871-1873
    • /
    • 2000
  • There are many electrical accidents between bare wire and line post insulator which is degraded by long time using, causing leakage current on the surface of insulator. In this paper it is presented that the 22.9 Kv-y distribution lines are protected by binding cover which is needed from fog or rainy moisture, surges occurring by switching or lightening pulse. It is analyzed to investigate the unbalanced transfer characteristics and reflection coefficient by using binding cover and non-cover. It was tested the radio interference voltage in the test room and electric field strength by calculation between binding cover and non-cover. In the factory the leakage current causing on the surface of insulator was tested in the state of light load and heavy load.

  • PDF

Interference Analysis of Wireless Systems with Arbitrary Antenna Patterns and Geographic Information in the VHF/UHF Bands (VHF/UHF 대역에서 지리정보와 임의 안테나 패턴을 갖는 무선시스템의 간섭분석 연구)

  • Suh, Kyoung-Whoan
    • Journal of Broadcast Engineering
    • /
    • v.18 no.3
    • /
    • pp.445-454
    • /
    • 2013
  • By using the radio propagation prediction of Rec. ITU-R P.1546, geographic information system, and S-I plane, we presented the methodology of interference analysis based on the minimum coupling loss, and also suggested the local coordinate system for calculating azimuth and elevation angles between the victim receiver and the interferer for an arbitrary antenna pattern. To check the presented algorithm, the map with the land-sea mixed area was taken for the given area of $80{\times}60[km^2]$ as real geography information. Field strength, path profile, and protection ratio with maximum allowable interference level have been illustrated for radar and fixed wireless system for the assumed frequency. In addition interference power of the victim receiver was calculated asa function of azimuth and elevation angles of the interferer. The developed methodology of interference analysis in the VHF and UHF bands can be actually applied to assess interoperability as well as compatibility in the civil or military applications.

A Study on the Prediction of Electric Field Strength for Terrestrial TV Broadcasting by Digital Adoption (지상파 TV 방송의 디지털 전환에 따른 전계 강도 예측에 대한 연구)

  • Suh, Kyoung-Whoan;Jung, Hyuk;Jang, Jeong-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.38-46
    • /
    • 2011
  • In this paper, we propose a calculation methodology of the service distance to assure the satisfactory quality of service for analogue and digital TV receivers. Using the field strength formulation for TV receiver based upon Rec. ITU-R P.1546, computational results are presented and discussed for both systems, and some important factors are reviewed in terms of the equivalent level of service, which must be kept due to ATV to DTV conversion. The presented method provides the predicted values of field strength at receiver areas to check whether transmission quality can be satisfied or not, and it can be also used for obtaining the protection ratio or separated distance from co-channel or adjacent interference signal.

Electromagnetic interference caused by an electric-line current in a cable tray in nuclear power plants

  • Lee, Hoon-Keun;Kim, Yong-Hwa;Choo, Jaeyul
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3314-3318
    • /
    • 2021
  • This paper presents a mode-matching analysis of the electromagnetic coupling between open cable trays in an indoor structure when an electric-line current is generated as an electromagnetic source. We validated the mode-matching method by comparing the mode-matching results with those computed from a commercial electromagnetic simulator and then investigated the strength of the electric-field coupled in a victim cable tray while varying the distances between cable trays and architectural surfaces. The results of this study provide geometrical information on the placement of open cable trays to avoid electromagnetic interference problems.

Frequency Compatibility of FH Spread spectrum Communications in TV Channels (FH대역확산통신과 TV채널의 주파수 양립성에 관한 연구)

  • 박창일;조형래;이명수;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.14 no.1
    • /
    • pp.84-92
    • /
    • 1989
  • The purpose of this paper is to demonstrate the effect of a FH spread spectrum communication interference in TV channels and frequency compatibility in 30-88 MHz frequency band. To calculate this interferece, the strength of electric field of TV signals is derived as a function of distance between TV transmitter and receiver. An interference model is established based upon thefield strength by using the relation between the transmitted power of FH spread spectrum communications and the distance between the TV image signals, which makes TV screen a cceptble, Simultaneous transmission of FH sprea spectrum signals and TV signals is shown to be feasible, as far as the interference level is lower than the TV image signal level by 23.5dBm. As a result of frequency analysis and experiment, the FH spread spectrum communication can be used together with TV channels.

  • PDF

The Characteristics of Electric Field Distributions in a Reverberation Chamber using Cylindrical Diffuser (원통형 확산기를 사용한 전자파 잔향실내의 전기장 분포특성)

  • Lee, Yong;Rhee, Joong-Geun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.121-127
    • /
    • 2008
  • This paper presents an electric field distribution in a reverberation chamber using cylindrical diffuser. The characteristics of electric field distributions are compared with QRD(Quadratic Residue Diffuser) and cylindrical diffuser for $1{\sim}3$ GHz frequency band. The FDTD(Finite-Difference Time-Domain) method is used to analyze the field characteristics, and the field uniformity. At 2 GHz, the standard deviation and the tolerance of test volume in the reverberation chamber are improved by 0.11 dB, 0.43 dB for the case of cylindrical diffuser. The field strength is increased by 43.2 dBmV/m vs QRD's of 36.6 dBmV/m. Comparing with QRD's, the characteristic of polarization is also improved. These results show that reverberation chamber using cylindrical diffuser can be used alternative facility for measurement of electromagnetic interference and immunity.

A Study on the Prediction of Teeth Deformation of the Automobile Transmission Part(Shaft/Gear) in Warm Shrink Fitting Process (온간압입공정에서 자동차 변속기 단품(축/기어) 치형 변화 예측에 관한 연구)

  • Kim, Ho-Yoon;Choi, Chang-Jin;Bae, Won-Byong;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.54-60
    • /
    • 2006
  • Fitting process carried out in automobile transmission assembly line is classified into three classes; heat fitting, press fitting, and their combined fitting. Heat fitting is a method that heats gear to a suitable range under the tempering temperature and squeezes it toward the outer diameter of shaft. Its stress depends on the yield strength of gear. Press fitting is a method that generally squeezes gear toward that of shaft at room temperature by press. Another method heats warmly gear and safely squeezes it toward that of shaft. Warm shrink fitting process for automobile transmission part is now gradually increased, but the parts (shaft/gear) assembled by this process produced dimensional changes of gear profile in both radial and circumferential directions. So that it may cause noise and vibration between gears. In order to solve these problems, we need an analysis of warm shrink fitting process, in which design parameters are involved; contact pressure according to fitting interference between outer diameter of shaft and inner diameter of gear, fitting temperature, and profile tolerance of gear. In this study, an closed form equation to predict contact pressure and fitting load was proposed in order to develop optimization technique of warm shrink fitting process and verified its reliability through the experimental results measured in the field and FEM, that is, thermal-structural coupled field analysis. Actual loads measured in the field have a good agreement with the results obtained by theoretical and finite element analysis and also the expanded amounts of the gear profile in both radial and circumferential directions are within the limit tolerances used in the field.

A Study on the Radiated Noise from Power Line during EFT Immunity Test (EFT(Electrical Fast Transient)내성 시험시 발생되는 전원선 복사 잡음에 관한 연구)

  • 정삼영;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.234-241
    • /
    • 2000
  • During the EFT immunity test, the fast transient voltage is injected to the power or signal line. The radiated noise from these lines influences the near-by EUT, and consequently, the reliability of the test result can be jeopardized. The measured data of the field strength and wave shape of the noise were compared with the result of the mathematical analysis using transmission line model. When the tests were performed by the conditions the same as stated in IEC 61000-4-4, the results showed that the magnitude of the radiated electric field strength was about 2.4KV/m, and it can cause severe interference to the intended operation of EUT.

  • PDF

The Insulation Design of Enclosure for Diagnostic Device in Extra High Voltage Line (초고압 선로 진단장치용 외함 절연설계)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.3
    • /
    • pp.201-207
    • /
    • 2015
  • In this paper, in order to avoid equipment malfunction due to electromagnetic waves, which can occur when high-voltage live line diagnostic device fabrication, the enclosure structure of the diagnostic device with power lines that can minimize the EMI (electromagnetic interference) was modeled using the FEM (finite element method). Simulation examined the strength of the electric field in the required thickness, material and regions where there is a control board while changing the curvature radius of the corner making the enclosure, and By applying a mechanical design and simulation results that occur during the actual production has been designed for the final design. Most of the simulation results for the electric field is concentrated in the final model, the inner edge of the enclosure could be confirmed that the stable structure.

Quiet Zone Generation by Absorption Materials (흡음재 배치를 이용한 정숙 공간 형성 방법)

  • Park, Joo-Bae;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.403-408
    • /
    • 2000
  • An acoustic field in a 3 dimensional enclosure is caused from interference between sound sources and the complex reflections from wall. Therefore, changing an acoustic property of wall such as admittance means generating another acoustic field. The purpose of this paper is utilizing the characteristic to make a quiet zone. First, this paper shows that the control material is essentially on the same road as active noise control(ANC). That is, we can consider the control material as the control source of ANC. However we cannot control the reflection strength of it. Second, through a numerical simulation, this paper shows that the position of the control material is an important variable of the control.

  • PDF