• Title/Summary/Keyword: Interference Range

Search Result 644, Processing Time 0.029 seconds

Development of the Railway Abrasion Measurement System using Camera Model and Perspective Transformation (카메라 모델과 투시 변환에 의한 레일 마모도 측정 시스템 개발)

  • Ahn, Sung-Hyuk;Kang, Dong-Eun;Moon, Hyoung-Deuk;Park, So-Yeon;Kim, Man-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1069-1077
    • /
    • 2008
  • The railway abrasion measurement system have to satisfy two conditions to increase the measurement accuracy as follows. The laser region which is projected on the rail have to be extracted without the geometrical distortion. The mapping of the acquired laser region data on the rail profile have to be processed exactly. But, the conventional railway abrasion measurement system is deeply effected by the foreign substance( dust, rainwater, and so on ) on the railway or the sensitive response characteristic of the laser to the external measurement circumstance, and then the measurement errors arise from above factors. When the laser region is projected on the rail extracts from the acquired image, the interference of the light with the same frequency as the laser system occurs the serious problems. In the process of the mapping between the railway profile and the extracted laser region, the measurement accuracy is very highly effected by the geometrical distortion and the abnormal variation. In this Paper, we propose the novel method to increase the accuracy of the railway abrasion measurement dramatically. we designed and manufactured the high precision and fast image processing board with DSP Core and FPGA to measure the railway abrasion. The image processing board has the capability that the image of 1024X1280 from camera can be processed with the speed of 480 frame/sec. And, we apply the image processing algorithm base on the wavelet to extract the laser region is projected on the rail exactly. Finally, we developed high precision railway abrasion measurement system with the error range less than +/-0.5mm by which 2D image data is covered 3D data and mapped on the rail profile using the camera model and the perspective transform.

  • PDF

Variation of Amylose Content Using dsRNAi Vector by Targeting 3'-UTR Region of GBSSI Gene in Rice (GBSSI 유전자 3'UTR 영역의 발현 억제 dsRNAi 벡터를 이용한 아밀로스함량 조절 벼 개발)

  • Park, Hyang-Mi;Choi, Man-Soo;Chun, Areum;Lee, Jeung-Heui;Kim, Myeong-Ki;Kim, Yeon-Gyu;Shin, Dong-Bum;Lee, Jang-Yong;Kim, Yul-Ho
    • Korean Journal of Breeding Science
    • /
    • v.42 no.5
    • /
    • pp.515-524
    • /
    • 2010
  • The amylose content of starch is a major factor in the texture of cooked cereal grains. Therefore, down-regulation of amylose synthesis is one of the alternative method to improve eating quality of rice. We developed transgenic rice plants designed to suppress granule-bound starch synthase I(GBSSI) gene using RNA interference(RNAi) technology. Transgenic plants with RNAi vector containing the 3'-UTR region of GBSSI showed a lower amylose content in rice endosperm than that of wild-type. The range of amylose content was 5.9~9.0% in the transgenic plants, whereas that of wild-type was 17.7~18.0%. Transgenic rices showed the decrease of short chain and the increase of long chain by analyzing chain length distribution of amylopectin in the endosperm. In the SEM micrographs, we found that compound starch granules in whole grains of the wild-type rice were readily split during fracturing, while the starch granules in RNAi-transgenic lines showed small voluminous, non-angular rounded bodies.

Development of Compact and Lightweight Broadband Power Amplifier with HMIC Technology (HMIC 기술을 적용한 소형화 경량화 광대역 전력증폭기 개발)

  • Byun, Kisik;Choi, Jin-Young;Park, Jae Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.695-700
    • /
    • 2018
  • This paper presents the development of compact and lightweight broadband power amplifier module using HMIC (Hybrid Microwave Integrated Circuit) technology that could be high-density integration for many non-packaged microwave components into the small area of a high dielectric constant printed circuit board, such as a ceramic substrate, also using the special design and fabrication schemes for the structure of minimized electromagnetic interference to obtain the homogeneous electrical performance at the wideband frequency. The results confirmed that the small signal gain has a gain flatness of ${\pm}1.5dB$ within the range of 32 to 36 dB. In addition, the output power satisfied more than 30 dBm. The noise figure was measured within 7 dB, and OIP3 (Output Third Order Intercept Point) was more than 39 dBm. The fabricated broadband power amplifier satisfied the target specification required to electrically drive the high power amplifiers of jamming generators for electronic warfare, so the actual applicability to the system was verified. Future studies will be aimed at designing other similar microwave power amplifiers in the future.

A Technique for Interpreting and Adjusting Depth Information of each Plane by Applying an Object Detection Algorithm to Multi-plane Light-field Image Converted from Hologram Image (Light-field 이미지로 변환된 다중 평면 홀로그램 영상에 대해 객체 검출 알고리즘을 적용한 평면별 객체의 깊이 정보 해석 및 조절 기법)

  • Young-Gyu Bae;Dong-Ha Shin;Seung-Yeol Lee
    • Journal of Broadcast Engineering
    • /
    • v.28 no.1
    • /
    • pp.31-41
    • /
    • 2023
  • Directly converting the focal depth and image size of computer-generated-hologram (CGH), which is obtained by calculating the interference pattern of light from the 3D image, is known to be quite difficult because of the less similarity between the CGH and the original image. This paper proposes a method for separately converting the each of focal length of the given CGH, which is composed of multi-depth images. Firstly, the proposed technique converts the 3D image reproduced from the CGH into a Light-Field (LF) image composed of a set of 2D images observed from various angles, and the positions of the moving objects for each observed views are checked using an object detection algorithm YOLOv5 (You-Only-Look-Once-version-5). After that, by adjusting the positions of objects, the depth-transformed LF image and CGH are generated. Numerical simulations and experimental results show that the proposed technique can change the focal length within a range of about 3 cm without significant loss of the image quality when applied to the image which have original depth of 10 cm, with a spatial light modulator which has a pixel size of 3.6 ㎛ and a resolution of 3840⨯2160.

The review on standard method of microplastics in soil and groundwater (토양, 지하수 중 미세플라스틱 분석법에 관한 고찰)

  • JongBeom Kwon;Hyeonhee Choi;Sunhwa Park
    • Analytical Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.174-188
    • /
    • 2024
  • This review summarized research trends regarding sample collection methods, pretreatment method, and types of analysis devices for microplastics (MPs) in soil and groundwater matrices. Soil sampling considers the selection of sampling location, depth, and volume. The typically sampling depth is within 15 cm (topsoil), and about 1 kg of mixed each sample. Among spot sampling and continuous flow sampling, groundwater sampling mainly used a continuous flow sampling, with collection rates 2 to 6 L/min in the range of 300~1,000 L, and followed by immediate on-situ filtration. Pretreatment method, applied to soil and groundwater, consist of organic digestion and density separation. In the organic digestion method, H2O2 is recommended among H2O2, acidic, alkaline, and enzymatic method. NaCl is primarily used as a reagent in density separation. However, depending on the density of MPs, other regents can be selectively used like ZnCl2, ZnBr2, and etc. Representative analysis device includes Fourier Transform Infrared (FTIR) and Raman spectroscopy for non-destructive analysis and Pyrolysis Gas Chromatography Mass Spectrometry (Py-GC/MS) for destructive analysis. µ-FTIR and Raman can count MPs of larger than 10 and 1 ㎛, and analyze MPs materials. However, it is need to sufficiently remove interference, like organic matter, in spectroscopic analysis using essential pretreatment method. Py-GC/MS is being continuously researched because it doesn't require complex pretreatment method and allows quantitative analysis of specific materials.

Improvement of analytical methods for arsenic in soil using ICP-AES (ICP-AES를 이용한 토양 시료 중 비소 분석 방법 개선)

  • Lee, Hong-gil;Kim, Ji In;Kim, Rog-young;Ko, Hyungwook;Kim, Tae Seung;Yoon, Jeong Ki
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.409-416
    • /
    • 2015
  • ICP-AES has been used in many laboratories due to the advantages of wide calibration range and multi-element analysis, but it may give erroneous results and suffer from spectral interference due to the large number of emission lines associated with each element. In this study, certified reference materials (CRMs) and field samples were analyzed by ICP-AES and HG-AAS according to the official Korean testing method for soil pollution to investigate analytical problems. The applicability of HG-ICP-AES was also tested as an alternative method. HG-AAS showed good accuracies (90.8~106.3%) in all CRMs, while ICP-AES deviated from the desired range in CRMs with low arsenic and high Fe/Al. The accuracy in CRM030 was estimated as below 39% at the wavelength of 193.696 nm by ICP-AES. Significant partial overlaps and sloping background interferences were observed near to 193.696 nm with the presence of 50 mg/L Fe and Al. Most CRMs were quantified with few or no interferences of Fe and Al at 188.980 nm. ICP-AES properly assessed low and high level arsenic for field samples, at 188.980 nm and 193.696 nm, respectively. The importance of the choice of measurement wavelengths corresponding to relative arsenic level should be noted. Because interferences were affected by the sample matrix, operation conditions and instrument figures, the analysts were required to consider spectral interferences and compare the analytical performance of the recommended wavelengths. HG-ICP-AES was evaluated as a suitable alternative method for ICP-AES due to improvement of the detection limit, wide calibration ranges, and reduced spectral interferences by HG.

Correlation of Serum Thyroglobulin and Thyroglobulin in the Wash out of the Needle in Thyroid Cancer (갑상선암에서의 혈중 Thyroglobulin 농도와 침생검 검체 Washout Solution의 Thyroglobulin 농도와의 상관관계)

  • An, Jae-Seok;Kim, Ji-Na;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.152-155
    • /
    • 2009
  • Purpose: The most widely accepted tool for follow up management of thyroid cancer patients is serum thyroglobulin (Tg) measurement, but its value is limited by the interference of anti-thyroglobulin antibodies (anti-Tg Ab). Recently thyroglobulin measurement in the wash out of fine-needle aspiration biopsy specimens (Tg-FNAB) is frequently used for differential diagnosis of recurrences/metastases. The aim of this study was the investigation of the diagnostic utility of Tg-FNAB compared with serum Tg. Materials and Methods: We enrolled 41 consecutive patients with thyroid cancer who were evaluated for Tg-FNAB between January 2007 and February 2008 retrospectively. We ruled out 6 patients who anti-Tg Ab positive (${\geq}$100 U/mL) in the RIA (BRAHMS anti-Tgn RIA 100Det; BRAHMS Aktiengesell schaft, Berlin, Germany). Serum Tg and Tg-FNAB were measured by immunoradiometric assay (BRAHMS Tg pluS RIA 100 Det; BRAHMS Aktienge sellschaft, Berlin, Germany). We evaluated for Tg-FNAB compared with serum Tg and corresponding cytological smear. To compare the values of the two the t-test was used. Results: Tg-FNAB values were significantly higher (median 1,060 ng/mL, range 0.2~434,000 ng/mL) than serum Tg (median 2.5 ng/mL, range 0.9~131 ng/mL) (p=0.0394). The rate of correspondence with Tg-FNAB between cytological result was 87.9% and 65.9% in the case of serum Tg. Tg-FNAB was positive in 28 (24 with positive and 4 with suspicious cytology). Of the remaining 13 patients with negative Tg-FNAB, 1 had suspicious and 12 had unsuspicious cytology. serum Tg was positive in 26 (17 with positive and 3 with suspicious and 6 with unsuspicious cytology), Of the remaining 15 patients with negative serum Tg, 8 was positive in cytological result and 1 had suspicious and 6 had unsuspicious cytology. Conclusions: Tg-FNAB measurement is more accurate with high sensitivity (87.9%) than serum Tg (65.9%). The Tg-FNAB was a useful predictor for detecting recurrences/metastases with serum Tg.

  • PDF

Study on the screening method for determination of heavy metals in cellular phone for the restrictions on the use of certain hazardous substances (RoHS) (유해물질 규제법(RoHS)에 따른 휴대폰 내의 중금속 함유량 측정을 위한 스크리닝법 연구)

  • Kim, Y.H.;Lee, J.S.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-14
    • /
    • 2010
  • It is of importance that all countries in worldwide, including EU and China, have adopted the Restrictions on the use of certain Hazardous Substances (RoHS) for all electronics. IEC62321 document, which was published by the International Electronics Committee (IEC) can have conflicts with the standards in the market. On the contrary Publicly Accessible Specification (PAS) for sampling published by IEC TC111 can be adopted for complementary application. In this work, we tried to find a route to disassemble and disjoint cellular phone sample, based on PAS and compare the screening methods available in the market. For this work, the cellular phone produced in 2001, before the regulation was born, was chosen for better detection. Although X-ray Fluorescence (XRF) showed excellent performance for screening, fast and easy handling, it can give information on the surface, not the bulk, and have some limitations due to significant matrix interference and lack of variety of standards for quantification. It means that screening with XRF sometimes requires supplementary tool. There are several techniques available in the market of analytical instruments. Laser ablation (LA) ICP-MS, energy dispersive (ED) XRF and scanning electron microscope (SEM)-energy dispersive X-ray (EDX) were demonstrated for screening a cellular phone. For quantitative determination, graphite furnace atomic absorption spectrometry (GF-AAS) was employed. Experimental results for Pb in a battery showed large difference in analytical results in between XRF and GF-AAS, i.e., 0.92% and 5.67%, respectively. In addition, the standard deviation of XRF was extremely large in the range of 23-168%, compared with that in the range of 1.9-92.3% for LA-ICP-MS. In conclusion, GF-AAS was required for quantitative analysis although EDX was used for screening. In this work, it was proved that LA-ICP-MS can be used as a screening method for fast analysis to determine hazardous elements in electrical products.

Magnetic and Electric Transport Properties of MnTe Thin Film Grown by Molecular Beam Epitaxy (분자선 증착법에 의해 성장한 MnTe 박막의 자기적 및 전기수송 특성)

  • Kim, Woo-Chul;Bae, Sung-Whan;Kim, Sam-Jin;Kim, Chul-Sung;Kim, Kwang-Joo;Yoon, Jung-Bum;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • MnTe layers of high crystalline quality were successfully grown on Si(100) : B and Si(111) substrates by molecular beam epitaxy (MBE). Under tellurium-rich condition and the substrate temperature around $400^{\circ}C$, a layer thickness of $700{\AA}$ could be easily obtained with the growth rate of $1.1 {\AA}/s$. We investigated the structural, magnetic and transport properties of MnTe layers by using x-ray diffraction (XRD), superconducting quantum interference device (SQUID) magnetometry, and physical properties measurement system (PPMS). Characterization of MnTe layers on Si(100) : B and Si(111) substrates by XRD revealed a hexagonal structure of polycrystals with lattice parameters, ${\alpha}=4.143{\pm}0.001{\AA}\;and\;c=6.707{\pm}0.001{\AA}$. Investigation of magnetic and transport properties of MnTe films showed anomalies unlike antiferromagnetic powder MnTe. The temperature dependence of the magnetization data taken in zero-field-tooling (ZFC) and field-cooling (FC) conditions indicates three magnetic transitions at around 21, 49, and 210 K as well as the great irreversibility between ZFC and FC magnetization in the films. These anomalies are attributable to a magnetic-elastic coupling in the films. Magnetization measurements indicate ferromagnetic behaviour with hysteresis loops at 5 and 300 K for MnTe polycrystalline film. The coercivity ($H_c$) values at 5 and 300 K are 55 and 44 Oe, respectively. In electro-transport measurements, the temperature dependence of resistivity revealed a noticeable semiconducting behaviours and showed conduction via Mott variable range hopping at low temperatures.

Comparison of Movement Distance and Home Range Size of Gold-spotted Pond Frog (Pelophylax chosenicus) between Rice Paddy and Ecological park - Focus on the Planning Alternative Habitat - (논과 생태공원에서 금개구리 이동 거리 및 서식영역 크기 비교 - 대체서식지 조성 중심으로 -)

  • Park, Su-Gon;Ra, Nam-Yong;Jang, Young-Soo;Woo, Seung Hyun;Koo, Kyo Soung;Chang, Min-Ho
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.4
    • /
    • pp.200-207
    • /
    • 2019
  • The movement distance and home range size of Pelophylax chosenicus were identified in the rice paddy and ecological park as alternative habitats from July to November 2017. A total of 39 frogs were tracked by radio tracking method. As a result, the average move distance in the population of rice paddy was 11.7 ± 1.9 m (n = 64) and the population of ecological park was 24.7 ± 4.3 m (n = 39). The move distance between the two populations was significantly different. The mean MCP of the population of rice paddy was 181.2 ± 110.8 m2 (n = 11) and the population of ecological park was 416.1 ± 276.2 m2 (n = 10), but there was no significant difference. The population area of rice paddy was 4,160 m2 (Kernel density 95%) and the core area was 1,080 m2 (Kernel density 50%). The population area (Kernel density 95%) of ecological park was 5,391 m2 and the core area (Kernel density 50%) was 736 m2. This study shows that it is appropriate to construct the area of alternative habitat for P. chosenicus at least 1.33 ha, and it is more advantageous for the ecological park to be constructed than the paddy field with high development pressure and human interference. If the rice paddies were to be abandoned for several years, or to be used traditional farming methods, such as refraining from using agricultural machinery and chemicals, they could be used as alternative habitat for P. chosenicus.