• Title/Summary/Keyword: Interference Range

Search Result 644, Processing Time 0.023 seconds

Measurement of Atmospheric BTX in Seoul Using Differential Optical Absorption Spectroscopy (차등흡수 분광법을 이용한 서울 대기 중 BTX 측정)

  • Lee Chulkyu;Choi Yeo Jin;Lee Jeong Soon;Jung Jin Sang;Kim Young Joon;Kim Ki Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • In this study, a Long Path Differential Optical Absorption Spectroscopy system (K-JIST LP-DOAS) has been used to simultaneously measure atmospheric monoaromatic hydrocarbons and other trace compounds. The validity of the K-JIST LP-DOAS for measuring atmospheric monoaromatic hydrocarbons was tested during a field campaign between 12 February and 14 March 2003 at an urban site in Seoul, Korea through inter-comparative measurements against a collocated on-line Gas Chromatography (GC) system. The concentrations of benzene, toluene, p-xylene, and m-xylene were measured with the K-JIST LP-DOAS system in the UV region (239~302 nm) over a 740 m beam path. For the other trace compounds, a longer spectral range (299~362 nm) was used. In order to remove the interference of atmospheric abundant species (such as oxygen, sulfur dioxide and ozone), two oxygen optical density spectra obtained at two pathlengths, 697 and 1133m, and reference spectra of sulfur dioxide and ozone were incorporated in the fitting procedure. The mean concentrations measured by our LP-DOAS during the measurement period were 0.77 ($\pm$0.38) ppbv for benzene, 3.68 ($\pm$1.90) ppbv for toluene, 0.41 ($\pm$0.19) ppbv for p-xylene, 0.54 ($\pm$0.24) ppbv for m-xylene. The concentration data of benzene, toluene, p-xylene and m-xylene obtained by our LP-DOAS were found to be in relatively good correlations with those of the online GC system. Pearson's coefficients in the observed concentrations between LP-DOAS and on-line GC were 0.84 for benzene, 0.83 for toluene and 0.65 for m,p-xylene. This study suggests that the LP-DOAS system can be used to provide reliable information on both the mixing ratios and temporal distribution characteristics of monoaromatic hydrocarbons in the urban air.

A Study on the Effects of Various Portable Wireless Communication Equipments on the Medical Equipments (각종 휴대용 무선 통신기기가 의료기기에 미치는 영향에 관한 연구)

  • 배한길;김종헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.3
    • /
    • pp.392-400
    • /
    • 1999
  • In this paper, the electromagnetic immunity of electronic medical equipments was tested by employing a standard test method for medical equipments. In addition, the electromagnetic interference to the medical equipments caused by four different types of mobile phones such as portable transceiver, analog, digital, and PCS cellular phones, have been studied. In this study, 16 medical equipments of 11 different types were investigated. There are a patient monitor, an infusion pump, a neonatal incubator and so on. In the case of the EMS test, the interferences were detected for seven medical equipments of four different types(53.3%) such as the patient monitor. For the two portable transceivers, 12 medical equipments of eight different models (75%) were affected. All medical equipments were satisfied with electromagnetic immunity by analog, digital and PCS cellular phones. The experiment results show that the malfunction of the electronic medical equipments is dependent on the frequency range and the electric field strength of the mobile phones.

  • PDF

Development of a Microwave Level Meter Using YIG-VCO for Industrial Process (YIG-VCO를 사용한 산업용 마이크로파 거리계의 개발)

  • 김정목;임종수;전중창;김태수;안광호;이승학
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2000
  • In this paper, we have designed a microwave level meter based on the FM-CW radar theory using a YIG-tuned oscillator (YTO). YTO has an excellent frequency linearity, so a linearizer circuit is not necessary for the level meter. It is shown that interference signals reflected from nearby obstacles can be removed by using a digital band-pass filter. An FIR band-pass filter is designed using the Kaiser window. The distance measurement has been performed in the outdoor test field. The measurement data have been obtained for the range of 1~40m with 1m step, and the results show that the standard deviation of the measured data is 2.33 cm. The level meter manufactured in this study can be applied usefully in the industrial facilities which are not accessible easily, for example, to measure the level of molten metal in the iron and steel company.

  • PDF

Reduction of Radiated Emission of an Infrared Camera Using a Spread Spectrum Clock Generator (확산 스펙트럼 생성기를 이용한 적외선 카메라의 방사노이즈 저감에 관한 연구)

  • Choi, Bongjun;Lee, Yongchun;Yoon, Juhyun;Kim, Eunjun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1097-1104
    • /
    • 2016
  • The infrared camera is difficult to satisfy the RE-102 specification of Mil-Std-461. Especially, in the case of UAV electronics, shielded cable is not used, so it is difficult to meet the electromagnetic compatibility standard. In the RE-102 test of the IR camera for UAV, radiated noise exceeding 30 dBuV/m was observed in the range of 50 MHz to 200 MHz. As a result of pcb em scan, peak noise which caused by the harmonic frequency of the digital control signal clock was observed. Radiated noise was reduced by up to 22.9 dBuV/m by applying the spread spectrum clock generator(SSCG) with 3 % down spreading method to the camera control clock.

Analysis of Noise Sensitivity due to Image Wireless Transmission (링크암호 환경에서 이미지 데이터와 잡음의 영향)

  • Kim, KiHwan;Kim, HyeongRag;Lee, HoonJae;Ryu, Young-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.211-220
    • /
    • 2018
  • The standard data link layer encryption provided by CCSDS has a structure that encodes HDLC frame into it using an AES algorithm. However, CCSDS is standard method has a structure in which the receiving side cannot request a re-activation when noise interference occurs over an unstable channel. SES Alarmed has a structure that enables the receiving side to additionally detect errors and perform re-activation requests in an operational structure similar to that of link encryption in CCSDS. The SES Alarmed related paper was intended to identify the optimum range of thresholds and identify data corruption due to channel noise. In this paper, the focus was on reducing the re-activation process if the HDLC frame, excluding the password Sync code, consistently exceeds any threshold levels. The HDLC frame order was changed and the results of using SES Alarmed were proposed and compared.

An Adaptive Control of Individual Channels' Transmission Power in Femtocells (펨토셀 환경에서 채널별 전송전력의 적응적 제어 기법)

  • Lee, Hoseog;Cho, Ho-Shin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.9
    • /
    • pp.762-771
    • /
    • 2012
  • In this paper, we propose an adaptive power control scheme employing a self-optimization concept in femtocell systems, in order to improve system capacity, thereby reducing call-drop probability. In the proposed scheme, each femto base station(FBS) controls individual channel's transmission power base on two parameters; the neighboring cell's transmission power for each individual channel which is delivered from a femto-gateway and the received power strength from neighboring cells which is periodically measured by means of a spectrum sensing. Adaptive adjustment of individual channel's transmission power in accordance with femto mobile station(FMS) mobility features can also reduce undesirable handovers and evenly distribute traffic load over all femtocells. In addition, the manipulative control of channel's transmission power is able to keep the system coverage and the call-drop probability within an acceptable range, regardless of density of femtocells. Computer simulation shows that the proposed scheme outperforms existing schemes in terms of the system coverage and the call-drop probability.

Absorption Properties of Thin Permalloy-Rubber Absorbers in Mobile Telecommunication Frequency Bands (Permalloy를 이용한 이동통신주파수 대역용 박형 전파흡수체의 제조 및 특성 연구)

  • Kim, Moon-Suk;Min, Eui-Hong;Koh, Jae-Gui
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.3
    • /
    • pp.115-119
    • /
    • 2008
  • The raw materials of permalloy were processed the ball-mill for 30 hours and the shape of permalloy particles was changed from sphere to flake type, which was observed using scanning electron microscope. The complex permittivity and permeability spectra and reflection loss of permalloy-rubber composite was measured using Network Analyzer in order to investigate the relationship between the microwave absorption and the material constants. The flake type permalloy-rubber composite showed high reflection loss, which was due to the high complex permittivity and permeability. Also, the matching frequency shifted toward lower frequency range with microwave absorber thickness, and the maximum reflection loss of -6.1 dB was observed in $1.65\;GHz{\sim}1.86\;GHz$ for a 1.3 mm thickness.

Channel Capacity of BLAST based on the Zero-Forcing criterion (Zero-Forcing 기반의 BLAST 채널 용량)

  • Lee, Heun-Chul;Kim, Hee-Jin;Lee, In-Kyu
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.12
    • /
    • pp.34-41
    • /
    • 2008
  • In this paper, we present an asymptotical analysis of channel capacity of Bell labs layered space-time (BLAST) architectures based on a zero-forcing (ZF) criterion in the sense of signal-to-noise ratio (SNR). We begin by introducing a new relationship related to multi-input multi-output (MIMO) channel capacity. We prove that Diagonal Bell Labs Space-Time (DBLAST) attains the lower bound for MIMO channels when interference nulling is carried out based on the ZF-criterion. An exact closed-form expression for the probability density function of the channel capacity is analyzed. Based on the asymptotic behavior of the channel capacity of each layer, closed-form expressions for the asymptotic ergodic capacity are derived for BLAST. Based on the analysis presented in this paper, we gain an insight on the channel capacity behavior for a MIMO channel. Computer simulation results have verified the validity and accuracy of the proposed analysis for a wide range of antenna array sizes.

Aspheric Lens Measurements by Digital Holographic Microscopy and Liquid (액체와 Digital Holographic Microscopy을 이용한 비구면 렌즈 측정 연구)

  • Kim, Doocheol;Shin, Sanghoon;Yu, Younghun
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.318-323
    • /
    • 2013
  • Digital holographic microscopy allows optical path difference measurement. Optical path difference depends on both the refractive index and the morphology of the sample. When interference fringes are very closely spaced, the phase data contain high frequencies where $2{\pi}$ ambiguities cannot be resolved. The immersion testing method, which is a transmission test while the sample is immersed in liquid, is very effective in reducing high frequency fringes in transmission measurements so that large dynamic range testing is possible for a non-null configuration. We developed a digital holographic microscope using liquid that can measure the high numerical aperture aspheric morphology of a sample. This system provides highly precise three-dimensional information on the sample. By improving the experimental method, choosing liquids which have similar refractive index to the sample, we can measure more accurate three-dimensional information on the samples.

Evaluation of Wind-Induced Vibration for Multiple Stacks Using Numerical Analysis (전산 해석을 이용한 다중연돌의 유체유발진동)

  • Yang, Kwangheok;Park, Chaegwan;Kim, Hyeonjoon;Baek, Songyoul;Park, Soontae
    • Plant Journal
    • /
    • v.12 no.3
    • /
    • pp.24-31
    • /
    • 2016
  • Wind-induced vibration is a phenomenon that a struture is oscillated due to wind force such as buffeting, vortex shedding wake and etc., which is one of important characteristics to be considered for design in case that stack has significant slenderness ratio or low natural frequency. International design standards of stack define several criteria for evaluating the suitability of stack design, which describe the required design considerations for each range of design parameters and provide the instruction to verify the stack design against wind-induced vibration simply. However, there is a limitation that they cannot provide quantitative information in case code requirement cannot be satisfied due to constraints of plant space or economical design. In order to overcome the limiation of code, integrated numerical analysis of computational fluid dynamics, harmonic analysis and finite element analysis were proposed to investigate wind-induced vibration for multiple stacks in actual plant. Simulated results of mutual wake interference effect between adjacent stacks were evaluated and compared to the criteria in international standards.

  • PDF