• Title/Summary/Keyword: Interference Range

Search Result 644, Processing Time 0.028 seconds

Effect of low frequency motion on the performance of a dynamic manual tracking task

  • Burton, Melissa D.;Kwok, Kenny C.S.;Hitchcock, Peter A.
    • Wind and Structures
    • /
    • v.14 no.6
    • /
    • pp.517-536
    • /
    • 2011
  • The assessment of wind-induced motion plays an important role in the development and design of the majority of today's structures that push the limits of engineering knowledge. A vital part of the design is the prediction of wind-induced tall building motion and the assessment of its effects on occupant comfort. Little of the research that has led to the development of the various international standards for occupant comfort criteria have considered the effects of the low-frequency motion on task performance and interference with building occupants' daily activities. It has only recently become more widely recognized that it is no longer reasonable to assume that the level of motion that a tall building undergoes in a windstorm will fall below an occupants' level of perception and little is known about how this motion perception could also impact on task performance. Experimental research was conducted to evaluate the performance of individuals engaged in a manual tracking task while subjected to low level vibration in the frequency range of 0.125 Hz-0.50 Hz. The investigations were carried out under narrow-band random vibration with accelerations ranging from 2 milli-g to 30 milli-g (where 1 milli-g = 0.0098 $m/s^2$) and included a control condition. The frequencies and accelerations simulated are representative of the level of motion expected to occur in a tall building (heights in the range of 100 m -350 m) once every few months to once every few years. Performance of the test subjects with and without vibration was determined for 15 separate test conditions and evaluated in terms of time taken to complete a task and accuracy per trial. Overall, the performance under the vibration conditions did not vary significantly from that of the control condition, nor was there a statistically significant degradation or improvement trend in performance ability as a function of increasing frequency or acceleration.

Study on the Removal of the Cable Braid Inside the Missile (유도탄 탄내케이블 브레이드 제거에 따른 고찰)

  • Eun, Hee-hyun;Kim, Ji-min;Lee, Min-hyoung;Jung, Jae-won
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.105-110
    • /
    • 2018
  • The North Korea nuclear issue is now posing a serious security threat to the Korea and Northeast Asia. Accordingly, the South Korean military is pushing for the introduction of long-range air-to-surface flights and the development of domestic nuclear facilities that can precisely hit North Korea headquarters building and nuclear facility even hundreds of kilometers above the border. In this paper, we removed the cable braid for securing the weight of the missile among several design elements for long-range air-to-surface missile development and estimated and analyzed the resulting performance. The possibility of braid removal was analyzed in terms of crosstalk inside the cable and CS114, RE101 of MIL-STD-461F.

Position Estimation Technique of High Speed Vehicle Using TLM Timing Synchronization Signal (TLM 시각 동기 신호를 이용한 고속 이동체의 위치 추정)

  • Jin, Mi-Hyun;Koo, Ddeo-Ol-Ra;Kim, Bok-Ki
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.5
    • /
    • pp.319-324
    • /
    • 2022
  • If radio interference occurs or there is no navigation device, radio navigation of high-speed moving object becomes impossible. Nevertheless, if there are multiple ground stations and precise range measurement between the high-speed moving object and the ground station can be secured, it is possible to estimate the position of moving object. This paper proposes a position estimation method using high-precision TDOA measurement generated using TLM signal. In the proposed method, a common error of moving object is removed using the TDOA measurements. The measurements is generated based on TLM signal including SOQPSK PN symbol capable of precise timing synchronization. Therefore, since precise timing synchronization of the system has been performed, the timing error between ground stations has a very small value. This improved the position estimation performance by increasing the accuracy of the measured values. The proposed method is verified through software-based simulation, and the performance of estimated position satisfies the target performance.

Measurement of the Shape in the Radioactive Area by Ultrasonic Wave Sensor

  • Park, Koon-Nam;Sim, Chuel-Muu;Park, Chang-Oong;Lee, Chang-Hee;Park, Jong-Hark
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2002
  • The HANARO ( High-flux Advanced Neutron Application Reactor) has been operated since 1995. The Cold Neutron (CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure exactly the size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersed ultrasonic technique is considered as the best way to measure the thickness and the diameter of the CN hole. The 4-Axis manipulator was designed and fabricated for locating the ultrasonic sensors. The transducer of an ultrasonic sensor having 10 MHz frequency leads to high resolution as much as 0.03mm. The inside diameter and thickness of 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results show that the thickness and inside diameter of the CN hole is in the range of 3.3∼6.7mm and 156∼ 165mm, respectively. This data will be a good reference for the design of the cold neutron source facility.

Nonmagnetic Impurity Effect in $CuF_{2}.2H_{2}O$ ($CuF_{2}.2H_{2}O$에서의 비자성 불순물 효과)

  • Chang Hoon Lee;Cheol Eui Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.2
    • /
    • pp.119-122
    • /
    • 1995
  • We have measured the magnetic susceptibilities of a CuF/sub 2/ .center dot. 2H/sub 2/O sample by means of the SQUID(superconducting quantum interference device) at the magnetic fields of 0.5 T and 1 mT, in the temperature range 5-300 K. The sample was found to contain some nonmagnetic calcium and magnesium impurities by the elemental analysis. Our measurements differ from known results for pure Cu F/sub 2/ .center dot. 2H/sub 2/O and are well explained by the effect of the nonmagnetic impurities in our sample. The purity of our sample derived from the temperature dependence of the susceptibilities was compared with that from the elemental analysis.

  • PDF

Electrospun Magnetic Nanofiber as Multifunctional Flexible EMI-Shielding Layer and its Optimization on the Effectiveness

  • Yu, Jiwoo;Nam, Dae-Hyun;Lee, Young-Joo;Joo, Young-Chang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.2
    • /
    • pp.57-63
    • /
    • 2016
  • We developed a flexible and micro-thick electromagnetic interference (EMI) shielding nanofabric layer that also functions as a water resisting and heat sinking material. Electrospinning followed by a simple heat treatment process was carried on to produce the EMI-shielding Ni/C hybrid nanofibers. The ambient oxygen partial pressure ($pO_2$ = 0.1, 0.7, 1.3 Torr) applied during the heat treatment was varied in order to optimize the effectiveness of EMI-shielding by modifying the size and crystallinity of the magnetic Ni nanoparticles distributed throughout the C nanofibers. Permittivity and permeability of the nanofibers under the electromagnetic (EM) wave frequency range of 300 MHz~1 GHz were measured, which implied the EMI-shielding effectiveness (SE) optimization at $pO_2$ = 0.7 Torr during the heat treatment. The materials' heat diffusivity for both in-plane direction and vertical direction was measured to confirm the anisotropic thermal diffusivity that can effectively deliver and sink the local heat produced during device operations. Also, the nanofibers were aged at room temperature in oxygen ambient for water resisting function.

Primary user localization using Bayesian compressive sensing and path-loss exponent estimation for cognitive radio networks

  • Anh, Hoang;Koo, Insoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.10
    • /
    • pp.2338-2356
    • /
    • 2013
  • In cognitive radio networks, acquiring the position information of the primary user is critical to the communication of the secondary user. Localization of primary users can help improve the efficiency with which the spectrum is reused, because the information can be used to avoid harmful interference to the network while simultaneity is exploited to improve the spectrum utilization. Despite its inherent inaccuracy, received signal strength based on range has been used as the standard tool for distance measurements in the location detection process. Most previous works have employed the path-loss propagation model with a fixed value of the path loss exponent. However, in actual environments, the path loss exponent for each channel is different. Moreover, due to the complexity of the radio channel, when the number of channel increases, a larger number of RSS measurements are needed, and this results in additional energy consumption. In this paper, to overcome this problem, we propose using the Bayesian compressive sensing method with a calibrated path loss exponent to improve the performance of the PU localization method.

Design of a Compact Laparoscopic Assistant Robot;KaLAR

  • Lee, Yun-Ju;Kim, Jona-Than;Ko, Seong-Young;Lee, Woo-Jung;Kwon, Dong-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2648-2653
    • /
    • 2003
  • This paper describes the development of a 3-DOF laparoscopic assistant robot system with motor-controlled bending and zooming mechanisms using the voice command motion control and auto-tracking control. The system is designed with two major criteria: safety and adaptability. To satisfy the safety criteria we designed the robot with optimized range of motion. For adaptability, the robot is designed with compact size to minimize interference with the staffs in the operating room. The required external motions were replaced by the bending mechanism within the abdomen using flexible laparoscope. The zooming of the robot is achieved through in and out motion at the port where the laparoscope is inserted. The robot is attachable to the bedside using a conventional laparoscope holder with multiple DOF joints and is compact enough for hand-carry. The voice-controlled command input and auto-tracking control is expected to enhance the overall performance of the system while reducing the control load imposed on the surgeon during a laparoscopic surgery. The proposed system is expected to have sufficient safety features and an easy-to-use interface to enhance the overall performance of current laparoscopy.

  • PDF

Selective Monitoring of Rutin and Quercetin based on a Novel Multi-wall Carbon Nanotube-coated Glassy Carbon Electrode Modified with Microbial Carbohydrates α-Cyclosophorohexadecaose and Succinoglycan Monomer M3

  • Jin, Joon-Hyung;Cho, Eun-Ae;Kwon, Chan-Ho;Jung, Seun-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1897-1901
    • /
    • 2010
  • Multi-wall carbon nanotube (MWNT)-modified glassy carbon electrodes (GCE) were prepared for simultaneous determination of rutin and quercetin. Microbial carbohydrates, $\alpha$-cyclosophorohexadecaose ($\alpha$-C16) and succinoglycan monomer M3 (M3) were doped into MWNTs to prepare a $\alpha$-C16-doped MWNT-modified GCE (($\alpha$-C16 + MWNTs)/GCE) and a M3-doped MWNT-modified GCE ((M3 + MWNTs)/GCE), respectively. The sensitivities of the ($\alpha$-C16 + MWNTs)/GCE to rutin and quercetin were 34.7 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ and 18.3 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$, respectively, in a linear range of $2\sim8{\mu}M$ at pH 7.2. The sensitivities of the (M3 + MWNTs)/GCE was 2.44 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ for rutin and 7.19 ${\mu}A\cdot{\mu}M^{-1}{\cdot}cm^{-2}$ for quercetin without interference.

RF Front-End Module Design of UWB Radars for Vehicle (차량용 UWB 레이더의 RF front-end 모듈 설계)

  • Park, Chi-Ho;Kim, Tae-Gyu
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.11
    • /
    • pp.61-68
    • /
    • 2008
  • In this paper, we propose a RF front-end developments for vehicle UWB radar systems. UWB systems have a very narrow pulse width that is below 1ns. Therefore, UWB is designed to have broadband quality of low power several GHz and must coexist with the radio communication system. UWB's advantages include high channel capacity and data rate, because precise resolution for multi-path can easily position estimate and Rake receiver. Also, UWB has low interference because it displays broadband quality of low power. Positioning is made possible by short range accuracy, which can reduce the expense of system design. An RF front-end module is designed using the DCR(Direct ConveRsion) method and is composed in RF for vehicles at a low-cost.