• Title/Summary/Keyword: Interference Measurement

Search Result 611, Processing Time 0.028 seconds

A Novel Nicotinamide Adenine Dinucleotide Correction Method for Mitochondrial Ca2+ Measurement with FURA-2-FF in Single Permeabilized Ventricular Myocytes of Rat

  • Lee, Jeong Hoon;Ha, Jeong Mi;Leem, Chae Hun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.19 no.4
    • /
    • pp.373-382
    • /
    • 2015
  • Fura-2 analogs are ratiometric fluoroprobes that are widely used for the quantitative measurement of [$Ca^{2+}$]. However, the dye usage is intrinsically limited, as the dyes require ultraviolet (UV) excitation, which can also generate great interference, mainly from nicotinamide adenine dinucleotide (NADH) autofluorescence. Specifically, this limitation causes serious problems for the quantitative measurement of mitochondrial [$Ca^{2+}$], as no available ratiometric dyes are excited in the visible range. Thus, NADH interference cannot be avoided during quantitative measurement of [$Ca^{2+}$] because the majority of NADH is located in the mitochondria. The emission intensity ratio of two different excitation wavelengths must be constant when the fluorescent dye concentration is the same. In accordance with this principle, we developed a novel online method that corrected NADH and Fura-2-FF interference. We simultaneously measured multiple parameters, including NADH, [$Ca^{2+}$], and pH/mitochondrial membrane potential; Fura-2-FF for mitochondrial [$Ca^{2+}$] and TMRE for ${\Psi}_m$ or carboxy-SNARF-1 for pH were used. With this novel method, we found that the resting mitochondrial [$Ca^{2+}$] concentration was $1.03{\mu}M$. This $1{\mu}M$ cytosolic $Ca^{2+}$ could theoretically increase to more than 100 mM in mitochondria. However, the mitochondrial [$Ca^{2+}$] increase was limited to ${\sim}30{\mu}M$ in the presence of $1{\mu}M$ cytosolic $Ca^{2+}$. Our method solved the problem of NADH signal contamination during the use of Fura-2 analogs, and therefore the method may be useful when NADH interference is expected.

A study on the performance test and acoustic design of interference type noise reduction device for railway noise (철도소음 저감을 위한 간섭형 방음장치 음향 설계 및 성능시험에 관한 연구)

  • Cho, Jun-Ho;Koh, Hyo-In
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.787-795
    • /
    • 2011
  • Noise barrier is generally used with welding of joint rail for railway noise reduction in our country. But the noise barrier for high speed railway has weak point in low frequencies about 315Hz band. In this study, For developing of Interference-type Noise Reduction Device(INRD), acoustic analysis were performed using commercial software. For verifying the improvement in the noise reduction, noise measurement before and after installing of INRD were performed in Anechoic Chamber. From these acoustic analysis and noise measurement, it was known that developed INRD has a good noise reduction performance and can be used efficiently with conventional noise barrier.

Dynamic Synchronous Phasor Measurement Algorithm Based on Compressed Sensing

  • Yu, Huanan;Li, Yongxin;Du, Yao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.1
    • /
    • pp.53-76
    • /
    • 2020
  • The synchronous phasor measurement algorithm is the core content of the phasor measurement unit. This manuscript proposes a dynamic synchronous phasor measurement algorithm based on compressed sensing theory. First, a dynamic signal model based on the Taylor series was established. The dynamic power signal was preprocessed using a least mean square error adaptive filter to eliminate interference from noise and harmonic components. A Chirplet overcomplete dictionary was then designed to realize a sparse representation. A reduction of the signal dimension was next achieved using a Gaussian observation matrix. Finally, the improved orthogonal matching pursuit algorithm was used to realize the sparse decomposition of the signal to be detected, the amplitude and phase of the original power signal were estimated according to the best matching atomic parameters, and the total vector error index was used for an error evaluation. Chroma 61511 was used for the output of various signals, the simulation results of which show that the proposed algorithm cannot only effectively filter out interference signals, it also achieves a better dynamic response performance and stability compared with a traditional DFT algorithm and the improved DFT synchronous phasor measurement algorithm, and the phasor measurement accuracy of the signal is greatly improved. In practical applications, the hardware costs of the system can be further reduced.

The Development of In-Plane Displacement Measurement System on Laser Speckle Interferometry (레이저 스페클 간섭법을 이용한 면내변위 측정시스템 개발)

  • Yoon H.S.;Kim K.S.;Park C.J.;Choi T.H.;Choi J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.556-560
    • /
    • 2005
  • The measurement method by Laser Speckle Interferometry which uses the interference law which will grow precedes and with it explains a resolution measurement ability and together the change of place arrowhead and general measurement, at real-time measurement sensitivity it has application boat song from candle precise measurement field it is increasing. But, currently the domestic application technique to sleeps and optical science military merit by optical science interferometer and directness it composes purchases to the level which it applies the expensive commercial business equipment the outside and in spite of the technical ripple effect is deficient even in many strong point. The hazard which complements like this problem point form technical development it leads from the research which it sees and an application degree and to sleep as the measurement equipment which tries to develop the small-sized optical science interference sensor and an interpretation program it raises it does.

  • PDF

Fabrication and statistical characterization of Nb SQUID sensors for multichannel SQUID system

  • Kim, B.K.;Yu, K.K.;Kim, J.M.;Kwon, H.;Lee, S.K.;Lee, Y.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.62-66
    • /
    • 2020
  • We fabricated superconducting quantum interference devices (SQUIDs) based on Nb Josephson junctions, and characterized the key parameters of the SQUIDs. The SQUIDs are double relaxation oscillation SQUIDs (DROSs) having larger flux-to-voltage transfer coefficient than the standard DC-SQUIDs. SQUID sensors were fabricated by using Nb junction technology consisted of a DC magnetron sputtering and a conventional photolithography process. In multichannel SQUID systems for whole-head magnetoencephalography measurement with a helmet-type SQUID array, we need about 336 SQUID sensors for each system. In this paper, we fabricated a few hundred SQUID sensors, measured the critical current, flux modulation voltage and decided if each tested SQUID can be used for the multichannel systems. As the criterion for the acceptance of the sensors, we chose the critical current and amplitude of the modulation voltage to be 8 ㎂ and 80 ㎶, respectively. The average critical current of the SQUIDs was 10.58 ㎂. The typical flux noise of the SQUIDs with input coil shorted was 2 μΦ0/√Hz at white region.

Development of microscopic surface profile estimation algorithm through reflected laser beam analysis (레이저 반사광 분석을 통한 미세 표면 프로파일 추정 알고리즘의 개발)

  • Seo Young-Ho;Ahn Jung-Hwan;Kim Hwa-Young;Kim Sun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.64-71
    • /
    • 2005
  • In order to measure surface roughness profile, stylus type equipments are commonly used, but the stylus keeps contact with surface and damages specimens by its tip pressure. Therefore, optics based measurement systems are developed, and light phase interferometer, which is based on light interference phenomenon, is the most noticeable research. However, light interference based measurements require translation mechanisms of nano-meter order in order to generate phase differences or multiple focusing, thus the systems cannot satisfy the industrial need of on-the-machine and in-process measurement to achieve factory automation and productive enhancement. In this research, we focused light reflectance phenomenon rather than the light interference, because reflectance based method do not need translation mechanisms. However, the method cannot direct]y measure surface roughness profile, because reflected light consists of several components and thus it cannot supply surface height information with its original form. In order to overcome the demerit, we newly proposed an image processing based algorithm, which can separate reflected light components and conduct parameterization and reconstruction process with respect to surface height information, and then confirmed the reliability of proposed algorithm by experiment.

Design and Implementation of a Blood-Glucose Meter to Reduce Hematocrit Interference (적혈구 용적률 간섭 보정을 위한 혈당 측정 기기의 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.4
    • /
    • pp.167-175
    • /
    • 2020
  • A blood-glucose meter is one of the in vitro diagnostic devices to measure and control the glucose concentration of diabetics. In order to measure the glucose level in the blood, the common method is to measure the amount of electrons, that is, the output current generated by glucose oxidation after a blood sample is inserted into the test strip containing an enzyme. The hematocrit is an obstacle in measuring accurate blood glucose concentration. This paper deals with the design and implementation of a blood-glucose meter to correct the hematocrit interference. We propose a sequential method which measures impedance using the alternating current and then measures glucose in the blood using the direct current. In addition, this paper introduces how to use commercial glucose strips based on the proposed system. Finally, we conducted the performance evaluation of the proposed system by comparing the measured current and impedance with those of the references. As a result, the standard deviation of the current measurement is approximately 0.6nA and the impedance measurement error for measuring the hematocrit is approximately within 1%. The proposed system will improve the accuracy of the conventional blood-glucose meter by reducing the hematocrit interference.

A Study on Prediction and Optimization of Radio Interference through Radar Operation Scenario Analysis (레이다 운용시나리오 분석을 통한 전파간섭예측과 최적화 연구)

  • Yoo, Woo-Sung;Kim, Sung-Gyun;Kwon, Yong-Wook;Lim, Ji-Hoon
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.53-63
    • /
    • 2021
  • As the types of radio equipment becomes more complex and diversified in various fields, radio interference occurs frequently. In the domestic situation where the territory is narrow, many systems are deployed in a specific highland with a good radio wave environment. Radar systems that transmit high power signals of the same band are sometimes deployed and operating at close distance. In this paper, the type of interference was classified for the actual radio wave interference phenomenon and appropriate signal interference parameters were derived. The power density of the interference signal was predicted using the analysis method and the effectiveness was verified through measurement. And, we propose a method to minimize interference by analyzing operating scenarios of interferer radar and victim radar.

Fused Navigation of Unmanned Surface Vehicle and Detection of GPS Abnormality (무인 수상정의 융합 항법 및 GPS 이상 검출)

  • Ko, Nak Yong;Jeong, Seokki
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.9
    • /
    • pp.723-732
    • /
    • 2016
  • This paper proposes an approach to fused navigation of an unmanned surface vehicle(USV) and to detection of the outlier or interference of global positioning system(GPS). The method fuses available sensor measurements through extended Kalman filter(EKF) to find the location and attitude of the USV. The method uses error covariance of EKF for detection of GPS outlier or interference. When outlier or interference of the GPS is detected, the method excludes GPS data from navigation process. The measurements to be fused for the navigation are GPS, acceleration, angular rate, magnetic field, linear velocity, range and bearing to acoustic beacons. The method is tested through simulated data and measurement data produced through ground navigation. The results show that the method detects GPS outlier or interference as well as the GPS recovery, which frees navigation from the problem of GPS abnormality.

Implementation and analysis of biometric information measurement method based on image processing (영상처리 기반 생체 정보 측정 방법 구현 및 분석)

  • Park, Tae-young;Bang, Seungcheol;Zhang, Junjun;Noh, Giseop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.37-39
    • /
    • 2022
  • As the COVID-19 pandemic hits the world, the Tokyo Olympics in 2021 will be held behind closed doors. Some broadcasters showed the heart rate of the players in real time using image processing-based non-contact measurement to convey the vividness of the scene on TV. However, since the non-contact model uses changes in the skin color of the players' faces according to blood circulation as a parameter, there is a possibility that errors may occur due to interference factors such as natural light or glasses. Therefore, in this paper, the non-contact heart rate measurement model and the contact heart rate measurement model are tested in an environment free from interference and their accuracy is analyzed.

  • PDF