• Title/Summary/Keyword: Interface treatment

Search Result 902, Processing Time 0.032 seconds

Conservative and esthetic closure of maxillary midline diastema without creating "black triangle" using direct resin composite (Black triangle이 존재하지 않는 보존적이고 심미적인 상악 정중이개의 치료)

  • Jung, Kyoung-Hwa;Kwon, Eun-Young;Choi, Youn-Kyung;Kim, So-Yeun;Jeon, Hye-Mi;Park, Jeong-Kil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.163-168
    • /
    • 2017
  • Anterior diastemas are common esthetic problems. One of the challenges in clinical esthetic dentistry is closing anterior diastemas without creating "black triangles" between the teeth. The success of a restorative treatment in anterior teeth depends on the esthetic integration between soft tissues and hard tissues. This report describes the successfully accomplished diastema closure case by producing the emergence profile with natural contours at the gingival-tooth interface and then generating of gingival recontouring process.

A Study on the Effect of CNT on Crystallization Kinetics and Hydrolytic Degradation of PKA/CNT Composite (PLA/CNT 복합재료의 결정화 특성 및 가수분해에 미치는 CNT 영향에 대한 연구)

  • Li, Mei-Xian;Kim, Sung-Ha;Kim, Si-Hwan;Park, Jong-Kyoo;Lee, Woo-Il
    • Composites Research
    • /
    • v.24 no.4
    • /
    • pp.5-10
    • /
    • 2011
  • As environmental pollution getting worse, biodegradable materials have been drawn more attention than ever. In this study, polylactic acid (PLA)/carbon nanotubc (CNT) nanocomposites were manufactured via extrusion molding and injection molding, In order to change the crystallinity, annealing treatment was done for different time span, Crystallization kinetics of PLA was analyzed by differential scanning calorimeter (DSC), and it was confirmed that a proper amount of CNT can increase the crystallization rate of PLA. In addition, the presence of CNT significantly accelerates the hydrolytic degradation rate of PLA, however, it decreases with the increase of crystallinity. The reason is that degradation may occur in the PLA/CNT interface easily, and the molecular structure of the composite becomes dense with the increase of crystallinity.

Development of Continuous SiC Fiber Reinforced Magnesium Composites Using Liquid Pressing Process (액상가압성형 공정을 이용한 SiC 연속섬유 강화 마그네슘 복합재료 개발)

  • Cho, Seungchan;Lee, Donghyun;Lee, Young-Hwan;Shin, Sangmin;Ko, Sungmin;Kim, Junghwan;Kim, Yangdo;Lee, Sang-Kwan;Lee, Sang-Bok
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.247-250
    • /
    • 2020
  • In this study, the possibility of manufacturing a magnesium (Mg) composites reinforced with continuous silicon carbide (SiC) fibers was examined using a liquid pressing process. We fabricated uniformly dispersed SiC fiberAZ91 composites using a liquid phase pressing process. Furthermore, the precipitates were controlled through heat treatment. As a continuous Mg2Si phase was formed at the interface between the SiC fiber and the AZ91 matrix alloy, the interfacial bonding strength was improved. The tensile strength at room temperature of the prepared composite was 479 MPa, showing excellent mechanical properties.

Disinfection of E. coli from Wastewater using a Non-contact type UV Photoreactor and Log Inactivation Index (비접촉식 자외선 광반응조를 이용한 하수 대장균의 살균과 Log 불활성화율 지표)

  • Kim, Sunghong;Kim, Kyungmyun;Kim, Gwangil;Choe, Jaewan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.139-145
    • /
    • 2016
  • Disinfection of microorganisms using UV light is widely used in the field of water supply and wastewater treatment plant, In spite of high germicidal effect and relatively clean by-product, UV disinfection has fundamental defeat that is accumulation of fouling materials at the interface of water and lamp sleeve. Non-contact type of UV photoreactor which can avoid this fouling generation was developed and the experimental performance evaluation of the system was carried out in this study. Log inactivation rate of E. coli was selected as a disinfection index. The concentration of E. coli of second clarifier effluent was $8.2{\times}10^1-8.2{\times}10^3$ colony per mL and was well inactivated by the non-contact type of UV photoreactor. Under the UV intensity condition of $2.1-2.5mW/cm^2$, E. coli removal rate was observed in the range of 54 - 95% when the HRT was increased from 10 to 52 seconds. Experimental results showed that log inactivation of E. coli was proportional to UV dosage and $200mJ/cm^2$ of UV dose is expected for the 2.0 log inactivation of E. coli from the second clarifier effluent. Between the two parameters of UV intensity and contact time which are consist of UV dose, UV intensity was 4 times more effective than contact time.

Effects of $WSi_x$, thickness and F concentration on gate oxide characteristics in tungsten polycide gate structure (Tungsten polycide gate 구조에서 $WSi_x$ 두께와 fluorine 농도가 gate oxide 특성에 미치는 영향)

  • 김종철
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.327-332
    • /
    • 1996
  • In this study, the effects of $WSi_x$, thickness and fluorine concentration in tungsten polycide gate structure on gate oxide were investigated. As $WSi_x$, thickness increases, gate oxide thickness increases with fluorine incorporation in gate oxide, and time-to-breakdown($T_{BD,50%}$) of oxide decreases. The stress change with $WSi_x$ thickness was also examined. But it is understood that the dominant factor to degrade gate oxide properties is not the stress but the fluorine, incorporated during $WSi_x$ deposition, diffused into $WSiO_2$ after heat treatment. In order to understand the effect of fluorine diffusion into oxidem fluorine ion implanted gates were compared. The thickness variation and $T_{BD,50%}$ of gate oxide is saturated over 600 $\AA$ thickness of $WSi_x$. The TEM and SIMS studies show the microstructure less than 600 $\AA$ thickness is dense and flat in surface. However, over 600$\AA$, the microstructure of $WSi_x$ is divided into two parts: upper porous phase with rugged surface and lower dense phase with smmoth interface. And this upper phase is transformed into oxygen rich crystalline phase after annealing, and the fluorine is captured in this layer. Therefore, the fluorine diffusion into the gate oxide is saturated.

  • PDF

Effect of W Substitution on the Precipitation Behavior of χ and σ Phase in Super Duplex Stainless Steels (슈퍼 2상 스테인리스강에서 χ와 σ상의 석출거동에 미치는 W치환의 영향)

  • Han, Huyn-Sung;Kim, Seong-Hwi;Kang, Chang-Yong
    • Korean Journal of Materials Research
    • /
    • v.26 no.4
    • /
    • pp.200-206
    • /
    • 2016
  • This study was carried out to investigate the effect of W substitution on the precipitation behavior of ${\chi}$ and ${\sigma}$ phases in super duplex stainless steel. The ${\chi}$ phase was precipitated at the interface of ferrite / austenite phases and inside the ferrite phase at the initial stage of aging. With an increase in the aging time, the volume fraction of the ${\chi}$ phase increased, and then decreased with the transformation from the ${\chi}$ phase to the ${\sigma}$ phase. The ${\sigma}$ phase was precipitated later than the ${\chi}$ phase, and the volume fraction of x phase increased with the increase in the aging time. The ferrite phase was decomposed into the new austenite (${\gamma}2$) and ${\sigma}$ phases by aging treatment. The decomposition of the ferrite phase into the ${\gamma}2$ and ${\sigma}$ phases was retarded by W substitution for Mo. The volume fraction of the ${\chi}$ phase increased and that of the ${\sigma}$ phase decreased due to W substitution. The ${\chi}$ and ${\sigma}$ phases were intermetallic compounds, which had lower nickel concentration, and higher chromium, molybdenum, and tungsten concentrations. The ${\chi}$ phase has higher molybdenum and tungsten concentrations than those of the ${\sigma}$ phase. The amounts of chromium and nickel in the ${\chi}$ and ${\sigma}$ phases did not change, but these phases have higher concentrations of molybdenum and tungsten due to W substitution for Mo.

The 3-Dimensional Finite Element Analysis of Minimum Implant Structure for Edentulous Jaw (무치악에 대한 최소 임플란트의 구조물의 3차원 유한요소 해석)

  • Jang, In-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.2
    • /
    • pp.148-155
    • /
    • 2008
  • The aim of the study is to interpret the distribution of occlusal force by 3-dimensional finite element analysis of ISP(Implant Supported Prosthesis) supported by minimum number of implant to restore the edentulous patients. For this study, the Astra Tech implant system is used. Geometric modeling for 6 and 4 fixture ISP group is performed with respect to the bone, implant and one piece superstructure, respectively. Implants are arbitrarily placed according to the anatomical limit of lower jaw and for the favorable distribution of occlusal force, which is applied at the end of cantilever extension of ISP with 30mm. Element type is tetrahedral for finite element model and the typical mechanical properties, Young's modulus and Poisson's ratio of each material, cortical, cancellous bone and implant material are utilized for the finite element analysis. From this study, we can see the distribution of equivalent stress equal to real situation and speculate the difference in the stress distribution in the whole model and at each implant fixture, From the analysis, the area of maximum stress is distributed on distal contact area between bone and fixture in the crestal bone. The maximum stress is 53MPa at the 0.2mm area from the bone-implant interface in the maximum side for 300N load condition for 4 fixture case, which is slightly less than the stress calculated from allowable strain. This stress has not been deduced to directly cause the loss of crestal bone around implant fixture, but the stress can be much reduced as the old peoples may have lower chewing force. Thus, clinical trial may be performed with this treatment protocol to use 4 fixtured ISP for old patients.

Embodiment of living body measure system modeling for Rehalibitation treatment of positive simulation for HRV algorithm analysis interface of Mobile base (모바일 기반의 HRV 알고리즘 분석 인터페이스에 대한 실증적 시뮬레이션의 재활치료용 생체계측 시스템 모델링의 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.4
    • /
    • pp.437-446
    • /
    • 2006
  • Mobilecomputer offers more fundamental role than role assistance enemy of modern technology equipment and new Information <중략> These main weakness puts in structural relation between elements that compose system. Therefore, dynamics research that time urea of systematic adjustment has selected method code Tuesday nerve dynamics enemy who groping of approach that become analysis point is proper and do with recycling bioelectricity signal. Nature model of do living body signal digital analysis chapter as research result could be developed and scientific foundation groping could apply HSS (Hardware-software system) by rehalibitation purpose. Special quality that is done radish form Tuesday of bioelectricity signal formation furthermore studied, and by the result, fundamental process of bodysignal in do structure circuit form of analog - digital water supply height modelling do can.

  • PDF

The Simulator Design for the Analysis of Aircraft Longitudinal Dynamic Characteristics (항공기 세로 동특성 해석을 위한 시뮬레이터 설계)

  • Yoon, Sun-Ju
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.4
    • /
    • pp.427-436
    • /
    • 2006
  • State-space method for the analysis of the dynamic characteristics of a body motion is set up as mathematical tool for the solution of differential equation by computer. Representation of a system is described as a simple form of matrix calculation and unique form of model is available for the linear or nonlinear, time variant or time invariant, mono variable or multi variable system etc. For the analysis of state-space method a complicated vector calculation is required, but this analysis can be simplified with the specific functions of a software package. Recently as the Graphical User Interface softwares are well-developed, then it is very simplified to execute the simulation of the dynamic characteristics for the state-space model with the interactive graphics treatment. The purpose of this study is to developed the simulator for the educational analysis of the dynamic characteristics of body motion, and for the analysis of the longitudinal dynamic characteristics of an aircraft that is primarily to design the simulator for the analysis of the transient response of an aircraft longitudinal stability.

  • PDF

Development of Portable Gamma Probe and Its Basic Performance Test (이동형 감마프로브 개발과 기본성능 평가)

  • Kim, H.J.;Kwark, C.;Choi, Y.;Yang, M.K.;Bong, J.K.;Lee, S.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.216-219
    • /
    • 1997
  • We are developing a portable multipurpose gamma counting and imaging probe that will be useful for many applications in nuclear medicine including radioimmunoguided surgery in the detection and treatment of malignant tumors. Any diagnostic information provided by CT, MRI, PET, SPECT or gamma camera imaging prior to surgery obviously is very important, but current techniques are limited in many instances. To overcome some of these limitations, the portable multipurpose gamma probe is being developed. The gamma probe consists of NaI(Tl) crystal with 1" dia $\times$ 0.5" thick and singlechannel photomultiplier tube (SC-PMT) for counting, and 3" dia $\times$ 0.375" and multichannel photomultiplier tube (MC-PMT) for imaging, nuclear instrument module (NIM), position circuits, interface, and PC. The energy resolution using Tc-99m was measured as 14% and the spatial resolution using 3mm dia green LED was measured as 2.9mm. These priliminary results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine.

  • PDF