• 제목/요약/키워드: Interface strength

검색결과 1,710건 처리시간 0.024초

Bond behaviour at concrete-concrete interface with quantitative roughness tooth

  • Ayinde, Olawale O.;Wu, Erjun;Zhou, Guangdong
    • Advances in concrete construction
    • /
    • 제13권3호
    • /
    • pp.265-279
    • /
    • 2022
  • The roughness of substrate concrete interfaces before new concrete placement has a major effect on the interface bond behaviour. However, there are challenges associated with the consistency of the final roughness interface prepared using conventional roughness preparation methods which influences the interface bond performance. In this study, five quantitative interface roughness textures with different roughness tooth angles, depths, and tooth distribution were created to ensure consistency of interface roughness and to evaluate the bond behaviour at a precast and new concrete interface using the splitting tensile test, slant shear test, and double-shear test. In addition, smooth interface specimens and two separate the pitting interface roughness were also utilized. Obtained results indicate that the quantitative roughness has a very limited effect on the interface tensile bond strength if no extra micro-roughness or bonding agent is added at the interface. The roughness method however causes enhanced shear bond strength at the interface. Increased tooth depth improved both the tensile and shear bond strength of the interfaces, while the tooth distribution mainly influenced the shear bond strength. Major failure modes of the test specimens include interface failure, splitting cracks, and sliding failure, and are influenced by the tooth depth and tooth distribution. Furthermore, the interface properties were obtained and presented while a comparison between the different testing methods, in terms of bond strength, was performed.

신구콘크리트 계면의 전단강도 측정을 위한 정하중 및 피로하중 보실험 (Beam Tests for Static and Fatigue Interface Shear Strength between Old and Njew Concretes)

  • 최동욱
    • 콘크리트학회지
    • /
    • 제9권3호
    • /
    • pp.137-147
    • /
    • 1997
  • 신구콘크리트 계면(접합부)의 전단강도 측정을 목적으로 보시험체를 사용한 정하중 및 피로하중의 재하실험이 수행되었다. 총 13개의 시험체중에서 정적재하실험을 통하여 5개 시험체의 전단강도를 측정하였고, 8개의 시험체는 2,000,000회 또는 3,000,000회의 반복하중을 가력한 후 전단강도를 측정하였다. 실험변수는 접합부거칠기, 전단보강철근 및 시구콘크리트간 부착력의 유무이었다. 정적재하실험에서, 접합부가 거칠면서 콘크리트간 부착력이 존재한 시험체의 경우, 평균전단강도는 $61kgf/cm^2$이었다. 유사한 조건의 시험체의 3,000,000회의 전단하중을 가력한 피로하중실험에서 접착부의 열화현상은 나타나지 않았다. 이 때 반복가력된 최대전단응력은 $20kgf/cm^2$으로 전단강도의 약 1/3수준이었다. 접합부가 거칠게 처리되지 않은 시험체와 접합부는 거칠지만 콘크리트간 부착력이 인위적으로 제거된 시험체의 경우에는 전단보강철근을 사용하여도 피로하중에 의한 접합부의 열화현상이 나타났다.

하프 PC판과 후타설콘크리트 접합면의 면내전단강도에 관한 실험적 연구 (An Experimental Study on In-Plane Shear Strength of the Interface between Half PC Plate and Cast-in-Place Concrete Plate)

  • 신동원;고만영;이동우;김용부
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.513-518
    • /
    • 1998
  • In Half Precast Concrete Method, such as composite slab and composite wall, Interface between half PC plate and cast-in-place concrete is occurred. And this interface endure lastly in-plane shear which is occurred by external force. Therefore, test was executed to study in-plane shear strength of interface between half PC plate and cast-in-place concrete. In this test, Experimental parameters are finishing condition of the interface, cohesion of concrete, existence and nonexistence of re-bar truss, and angle and direction of lattice of re-bar truss. Comparing and analyzing experimental results, conclusions are obtained as follows. (1) In-plane shear strength of wide interface in composite plate is more affected by the roughness of interface than re-bar truss. And cohesion of concrete contribute to increasing in-plane shear strength. Therefore it seems that the interface should be roughen and kept clean to improve in-plane shear strength. (2) It seems that shear friction equation in ACI code can be sagely available for design of in-plane shear of composite plate.

  • PDF

Shear strength behavior of crude oil contaminated sand-concrete interface

  • Mohammadi, Amirhossein;Ebadi, Taghi;Eslami, Abolfazl
    • Geomechanics and Engineering
    • /
    • 제12권2호
    • /
    • pp.211-221
    • /
    • 2017
  • A laboratory investigation into crude oil contaminated sand-concrete interface behavior is performed. The interface tests were carried out through a direct shear apparatus. Pure sand and sand-bentonite mixture with different crude oil contents and three concrete surfaces of different textures (smooth, semi-rough, and rough) were examined. The experimental results showed that the concrete surface texture is an effective factor in soil-concrete interface shear strength. The interface shear strength of the rough concrete surface was found higher than smooth and semi-rough concrete surfaces. In addition to the texture, the normal stress and the crude oil content also play important roles in interface shear strength. Moreover, the friction angle decreases with increasing crude oil content due to increase of oil concentration in soil and it increases with increasing interface roughness.

계면조건에 따른 에폭시와 고무 거시계면의 절연내력 (Dielectric Strength of Macro Interface between Epoxy and Rubber According to the Interface Condition)

  • 오용철;배덕권;김진사;김충혁
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.581-585
    • /
    • 2006
  • Macro interfaces between two different bulk materials which affect the stability of insulation system exist inevitably in the complex insulation system using in extra high voltage (EHV) electric devices. In this paper, Interface between epoxy and ethylene propylene diene terpolymer (EPDM) was selected as an interface in electrical insulation system and the AC dielectric strength of the interface was investigated. Air compress system was used to give pressure to the interface. Specimens were prepared in various ways to generate different surface conditions for each type of interface. Increasing interfacial pressure, decreasing surface roughness and spreading oil over surfaces improve the AC interfacial dielectric strength. Especially, the dielectric strength was saturated at certain interfacial pressure.

A comparative experimental study on the mechanical properties of cast-in-place and precast concrete-frozen soil interfaces

  • Guo Zheng;Ke Xue;Jian Hu;Mingli Zhang;Desheng Li;Ping Yang;Jun Xie
    • Geomechanics and Engineering
    • /
    • 제36권2호
    • /
    • pp.145-156
    • /
    • 2024
  • The mechanical properties of the concrete-frozen soil interface play a significant role in the stability and service performance of construction projects in cold regions. Current research mainly focuses on the precast concrete-frozen soil interface, with limited consideration for the more realistic cast-in-place concrete-frozen soil interface. The two construction methods result in completely different contact surface morphologies and exhibit significant differences in mechanical properties. Therefore, this study selects silty clay as the research object and conducts direct shear tests on the concrete-frozen soil interface under conditions of initial water content ranging from 12% to 24%, normal stress from 50 kPa to 300 kPa, and freezing temperature of -3℃. The results indicate that (1) both interface shear stress-displacement curves can be divided into three stages: rapid growth of shear stress, softening of shear stress after peak, and residual stability; (2) the peak strength of both interfaces increases initially and then decreases with an increase in water content, while residual strength is relatively less affected by water content; (3) peak strength and residual strength are linearly positively correlated with normal stress, and the strength of ice bonding is less affected by normal stress; (4) the mechanical properties of the cast-in-place concrete-frozen soil interface are significantly better than those of the precast concrete-frozen soil interface. However, when the water content is high, the former's mechanical performance deteriorates much more than the latter, leading to severe strength loss. Therefore, in practical engineering, cast-in-place concrete construction is preferred in cases of higher negative temperatures and lower water content, while precast concrete construction is considered in cases of lower negative temperatures and higher water content. This study provides reference for the construction of frozen soil-structure interface in cold regions and basic data support for improving the stability and service performance of cold region engineering.

Experimental study on rock-concrete joints under cyclically diametrical compression

  • Chang, Xu;Guo, Tengfei;Lu, Jianyou;Wang, Hui
    • Geomechanics and Engineering
    • /
    • 제17권6호
    • /
    • pp.553-564
    • /
    • 2019
  • This paper presents experimental results of rock-concrete bi-material discs under cyclically diametrical compression. It was found that both specimens under cyclical and static loading failed in three typical modes: shear crack, tensile crack and a combined mode of shear and wing crack. The failure modes transited gradually from the shear crack to the tensile one by increasing the interface angle between the interface and the loading direction. The cycle number and peak load increased by increasing the interface angle. The number of cycles and peak load increased with the interface groove depth and groove width, however, decreased with increase in interface groove spacing. The concrete strength can contribute more to the cycle number and peak load for specimens with a higher interface angle. Compared with the discs under static loading, the cyclically loaded discs had a lower peak load but a larger deformation. Finally, the effects of interface angle, interface asperity and concrete strength on the fatigue strength were also discussed.

표면 거칠기 정도가 접촉면 전단력에 미치는 영향 (The Influence of Surface Roughness on Interface Strength)

  • 이석원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.255-262
    • /
    • 1999
  • This paper summarizes the results of a study which uses the recently developed Optical Profile Microscopy technique (Dove and Frost, 1996) as the basis for investigating the role of geomembrane surface roughness on the shear strength of goomembrane/geotextile interfaces. The results show that interface friction can be quantitatively related to the surface roughness of the geomembrane. The peak and residual interface strengths increase dramatically through the use of textured geomembranes as opposed to smooth geomembranes. For the smooth geomembranes, the sliding of the geotextile is the main shear mechanism. For the textured geomembranes, the peak interface strength is mainly mobilized through the micro-texture of the geomembrane, however, the residual interface strength is primarily attributed to macro scale surface roughness which pulls out and breaks the filaments from the geotextile. The results of this study can be extended to the other interfaces such as joints in rock mass, and also can be used to provide a quantitative framework that can lead to a significantly improved basis for the selection and design of geotextiles and geomembranes in direct contact.

  • PDF

HDPE 표면처리 지오멤브레인의 경계면 전단강도에 관한 연구 (A Study on the Interface Shear Strength of HDPE Textured Geomembrane)

  • 김세진;윤희정
    • 한국지반환경공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.41-49
    • /
    • 2016
  • 본 논문에서는 HDPE 표면처리(textured) 지오멤브레인의 경계면 전단거동을 파악하고자 하였다. 표면처리 지오멤브레인과 marl, 그리고 직포(woven geotextile)와의 경계면에서 발생하는 경계면 전단강도를 측정하였으며, 표면처리의 영향을 파악하기 위해 매끈한(smooth) 지오멤브레인과 직포와의 경계면 전단강도를 측정하여 비교 분석하였다. 경계면 전단강도는 대형직접전단 시험기를 이용하여 측정하였으며, 다양한 조건에 대해 거동 변화를 알아보기 위해 수침조건과 수직응력을 변화시켰다. 시험에 사용된 수직응력은 총 6단계로 저압(12, 24, 45kPa)과 고압(100, 500, 1,000kPa)으로 구분하여 적용하였다. 시험결과 수침에 의한 경계면 전단강도의 감소는 유의미한 수준으로 나타났으며, 수직응력의 영향은 불확실했다. 표면처리 여부에 따라 경계면 전단강도는 큰 차이를 보여주었는데 매끈한 지오멤브레인의 경계면 전단강도는 표면처리 지오멤브레인에 비해 절반까지 감소하는 것으로 나타났다.

$ZrO_2/NiTi$ 접합부 반응조직에 따른 꺽임강도 및 파괴거동 변화 (The Variation of Fracture Strength and Modes in $ZrO_2/NiTi$ Bond by Changing Reaction Layer)

  • 김영정
    • 한국세라믹학회지
    • /
    • 제31권10호
    • /
    • pp.1197-1201
    • /
    • 1994
  • The fracture strength and fracture modes were studied in 3Y-TZP/NiNi bonding which change their interfacial structure with bonding condition. Average 4-point bending strength of 200 MPa to 400 MPa were achieved. The formation of Ti-oxide phase at the interface critically influenced the bonding strength and fracture mode. The fracture surface of Ti-oxide free interface contained multiphase in some case including ZrO2. From the result it was confirmed that in order to maximize the bonding strength crack deflection from interface to ceramic was required.

  • PDF