• Title/Summary/Keyword: Interface stability

Search Result 760, Processing Time 0.028 seconds

A Comparison of Various Governing Parameters on Hydrodynamic Stability in Interface on Small Solar Pond (소형태양수구내(小型太陽水構內) 중간경계면(中間境界面)에서 수력학적(水力學的) 안정(安定)에 관(關)한 각종(各種) 지배변수(支配變數)의 비교(比較))

  • Park, Ee-Dong
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.11-19
    • /
    • 1985
  • In this paper, the interface stability not to occur mixing and entrainment between the adjacent layers has been studied in the case of the selective withdrawal of a stratum and the injection in stratified fluid formed by the density difference in a small solar pond. There are stability parameter, Richardson number, Rayleigh number and Froude number as the parameters governing stability in order to measure the interface stability on the stratified fluid. The model which could measure the interface stability on the stratified fluid was the small solar pond composed by 1 meters wide, 2 meters high, and 5 meters long. In order to measure the interface stability on the stratified fluid at the inlet port, the middle section and the outlet port, Richardson number, Rayleigh number, and Froude number involved in the parameters governing the stability were calculated by means of the data resulted from the test of the study on hydrodynamic stability between the convective and nonconvective layers in that solar pond. Richardson number written by the ratio of inertia force to buoyancy force can be used in order to measure the stability on the stratified fluid related to the buoyancy force generated from the injection of fluid. Rayleigh number written by the product of Grashof number by Prandtl number can be used in order to measure the stability of the fluid related to the heat flux and diffusivity of viscosity. Froude number written by the ratio of gravity force to inertia force can be used in order to measure the stability of the nonhomogeneous fluid related to the density difference. As the result of calculating the parameters governing stability, the interface stability on the stratified fluid couldn't be identified below the 70cm height from the bottom of the solar pond, but it could be identified above the 70cm height from it at the inlet port, the middle section and the outlet port. When compared with such the three parameters as Richardson number, Rayleigh number, Froude number, the calculated result was in accord with them at inlet port, the middle section and the outlet port. Henceforth, it is learned that even though any of the three parameters is used for the purpose of measuring the interface stability on the stratified fluid, the result will be the same with them. It is concluded that all the use of Richardson number, Rayleigh number, and Froude number, is desirable and infallible to measure the interface stability on the stratified fluid in the case of considering the exist of the fluid flow and the heat flux like the model of the solar pond.

  • PDF

Finite element analyses of the stability of a soil block reinforced by shear pins

  • Ouch, Rithy;Ukritchon, Boonchai;Pipatpongsa, Thirapong;Khosravi, Mohammad Hossein
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.1021-1046
    • /
    • 2017
  • The assessment of slope stability is an essential task in geotechnical engineering. In this paper, a three-dimensional (3D) finite element analysis (FEA) was employed to investigate the performance of different shear pin arrangements to increase the stability of a soil block resting on an inclined plane with a low-interface friction plane. In the numerical models, the soil block was modeled by volume elements with linear elastic perfectly plastic material in a drained condition, while the shear pins were modeled by volume elements with linear elastic material. Interface elements were used along the bedding plane (bedding interface element) and around the shear pins (shear pin interface element) to simulate the soil-structure interaction. Bedding interface elements were used to capture the shear sliding of the soil on the low-interface friction plane while shear pin interface elements were used to model the shear bonding of the soil around the pins. A failure analysis was performed by means of the gravity loading method. The results of the 3D FEA with the numerical models were compared to those with the physical models for all cases. The effects of the number of shear pins, the shear pin locations, the different shear pin arrangements, the thickness and the width of the soil block and the associated failure mechanisms were discussed.

Synthesis of Antioxidant and Evaluation of Its Oxidation Stability for Biodiesel

  • Park, Soo-Youl;Shin, Seung-Rim;Shin, Joung-II;An, Kyoung-Lyong;Jun, Kun
    • Tribology and Lubricants
    • /
    • v.29 no.6
    • /
    • pp.392-396
    • /
    • 2013
  • Biodiesel fuels contain unsaturated fatty acid ester, which can easily oxidize, especially when exposed to ultraviolet light. The products formed by this oxidation give rise to sediment or gum formation. As a result, the fuel can contribute to the corrosion and plugging of the filter pump. Antioxidants have been used in an effort to stabilize biodiesels, but there is still a need for a biodiesel composition with improved oxidation stability. In general, good fuel compositions should provide synergistic combinations of a biodiesel and antioxidants. Our work involved the synthesis of antioxidants to improve the oxidative stability of biodiesel fuel.

Reactive Reserve Based Contingency Constrained Optimal Power Flow for Enhancement of Voltage Stability Margins (전압안정도 여유 향상을 위한 무효예비력 기반 상정사고 제약 최적조류계산)

  • Song, Hwa-Chang;Lee, Byong-Jun;Kwon, Sae-Hyuk;Ajjarapu, Venkataramana
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.19-23
    • /
    • 2003
  • This paper presents a new concept of reactive reserve based contingency constrained optimal power flow (RCCOPF) for voltage stability enhancement. This concept is based on the fact that increase in reactive reserves is effective for enhancement of voltage stability margins of post-contingent states, in this paper, the proposed algorithm is applied to voltage stability margin of interface flow. Interface flow limit, in the open access environment, can be a main drawback. RCCOPF for enhancement of interface flow margin is composed of two modules, modified continuation power flow (MCPF) and optimal power flow (OPF). These modules art recursively perform ed until satisfying the required margin of interface flow in the given voltage stability criteria.

  • PDF

Enhancement of Interface Flow Limit using Static Synchronous Series Compensators

  • Kim Seul-Ki;Song Hwa-Chang;Lee Byoung-Jun;Kwon Sae-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.313-319
    • /
    • 2006
  • This paper addresses improving the voltage stability limit of interface flow between two different regions in an electric power system using the Static Synchronous Series Compensator (SSSC). The paper presents a power flow analysis model of a SSSC, which is obtained from the injection model of a series voltage source inverter by adding the condition that the SSSC injection voltage is in quadrature with the current of the SSSC-installed transmission line. This model is implemented into the modified continuation power flow (MCPF) to investigate the effect of SSSCs on the interface flow. A methodology for determining the interface flow margin is simply briefed. As a case study, a 771-bus actual system is used to verify that SSSCs enhance the voltage stability limit of interface flow.

A Method of Determining the Maximum Interface Flow Limit Using Continuation Algorithm (연속알고리듬을 이용한 연계선로의 송전운용한계 결정)

  • Kim, Seul-Gi;Song, Hwa-Chang;Lee, Byeong-Jun;Gwon, Se-Hyeok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.2
    • /
    • pp.78-84
    • /
    • 2000
  • This paper introduces a method of determining the maximum real power transfer limit of interface lines, which connect two areas of a power system, using locally parameterized continuation algorithm. This method traces the path of power flow solutions as interface flow is gradually increased under a certain load demand condition and finds the steady state voltage stability limit, the interface flow limit. Voltage stability index is used to indicate how close the maximum limit is reached. Also, this study presents a procedure to determine the security-constrained interface flow limit using the above method. Contingency ranking index is proposed to identify the severity of contingencies. The case study is performed according to the suggested procedure.

  • PDF

A Study on the Interactive Grain Stability Calculation (대화형 Grain Stability Calculation에 관한 연구)

  • Lee, S.S.;Lee, K.O.;Kang, W.S.;Yoon, M.T.;Sung, D.K.;Lee, J.C.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.1
    • /
    • pp.102-110
    • /
    • 1997
  • In a shipyard, computer calculation is not frequently used for the grain stability calculation because of large difference between calculation values and real values. Therefore, the necessary calculation process for grain stability is done manually. GUI(Graphical User Interface) is adopted for the convenience of users and interactive data I/O. The hold shape (girder, hold, etc.)needed for calculation are visualized using GLBAX which is a 3 dimensional graphic library. The interface with the ship basic calculation package is also implemented. The aim of this paper is to develop a reliable interactive grain stability calculation program which reduces computational time, and is to computerize the grain stability calculation procedure.

  • PDF

A Study on Effects of SSSC Controllers on Interface Flow Limit (SSSC 투입에 따른 연계선로조류의 윤용한계 증대)

  • Song, Hwa-Chang;Lee, Byong-Jun;Kwon, Sae-Hyuk;Kim, Seul-Ki
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.2
    • /
    • pp.83-89
    • /
    • 2001
  • This paper introduces a power flow model of SSSC for voltage stability analysis of power system installed with Static Synchronous Compensators. The SSSC model is obtained from the injection model of voltage source inverter by adding the condition that SSSC injection voltage is in quadrature with current of SSSC-installed branch. This model is incorporated into modified CPF algorithm to study effects of SSSC on the security-constrained interface flow limit. Determination of interface flow limit is simply briefed. In case study a 771-bus real system is used to show that interface flow limit can be improved by appropriate control of SSSC in terms of voltage stability.

  • PDF

Structure and Properties of Rapidly-Solidified Al-Pb Monotectic Alloys.;I. Characteristics of Rapidly-Solidified Microstructure (급속 응고한 Al-Pb 편정 합금의 조직과 성질;I. 급속 응고 조직 특성)

  • Kim, Myung-Ho;Bae, Cha-Hurn;Lee, Ho-In
    • Journal of Korea Foundry Society
    • /
    • v.9 no.1
    • /
    • pp.73-79
    • /
    • 1989
  • Microstructural characteristics of Al-3.63wt.%Pb hyper-monotectic alloy rapidly-solidified by melt spinning were examined. Possibility of forming a planar liquid -solid interface during rapid solidification of this alloy was also considered with a morphological stability theory, and a mechanism of forming banded structure observed at the bottom parts of melt-spinned specimens was considered as well. Application of the absolute stability criterion predicts the liquid-solid interface of the primary aluminium phase to be able to maintain a planar interface during the early stage of rapid solidification. Formation of banded structure was supposed to be resulted from the release of latent heat during solidification, which affect the stability of a planar liquid-solid interface.

  • PDF

1-DOF Haptic Interface Controller Design considering Transparency and Robust Stability (투명성과 강인 안정성을 고려한 1자유도 햅틱 인터페이스 제어기 설계)

  • Eom, Gwang-Sik;Seo, Il-Hong
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.4
    • /
    • pp.213-219
    • /
    • 2000
  • In this paper, a controller design method is proposed for haptic interface considering transparency and robust stability. For this, a performance index for the transparency as performance measure is defined in the points of impedance matching and the optimal solution which is minimizing the performance index is obtained by solving H2 optimal problem. In haptic interface, the modeling uncertainties can be restricted to that of haptic device. To implement the robust stabilizing haptic controller to the uncertainties of haptic device, a robust stable condition using H$\infty$ norm from small gain theorem is proposed. To verify the effectiveness of the proposed haptic controller design scheme, numerical examples and experimental results are illustrated for virtual wall consisting of stiffness and damping factor.

  • PDF