• 제목/요약/키워드: Interface shear strength

검색결과 494건 처리시간 0.023초

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

Finite Elerllent Analysis of the Pull-out Test

  • Yi, Chang-Tok
    • 한국지반공학회지:지반
    • /
    • 제12권3호
    • /
    • pp.49-62
    • /
    • 1996
  • 인발시험은 보강토 구조물의 설계에 있어 보강재와 흙사이의 강도 정수를 결정하는데 사용된다. 그러나 이 시험의 해석시 보강재를 따라 발생하는 전단강도가 일정한 것으로 가정하는데 이는 인발시험중 흙과 보강재 사이의 점진성 전단으로 인해 흙과 보강재의 전단-변위 관계 계산시 오류가 발생하게 된다. 구과 보강재 사이의 shear stiffness계산시 점진성전단의 영향을 평가하기 위하여 유한요소법으로 인발시헙을 해석하였다. 흙과 보강재는 선형과 비선형거동으로 채석하였고 shear stiffnss는 일반적인 방법으로 계산하였는데 수정된 shear stiffness와는 많은 차이가 있었으며 그 차이로 인해 유한요소해석의 결과가 달라지게 된다. 본 논문에서는 유한요소해석결과와 시험치를 비교 분석하였으며 개선된 인발시험 해극방법에 대하여 논하였다.

  • PDF

PFC를 이용한 입자와 비파쇄 평면과의 접촉면에서의 전단 거동 (Shear behavior at the interface between particle and non-crushing surface by using PFC)

  • 김은경;이정학;이석원
    • 한국터널지하공간학회 논문집
    • /
    • 제14권4호
    • /
    • pp.293-308
    • /
    • 2012
  • 암반 절리면과 같이 입자와 연속체 평면의 접촉면에서의 전단거동은 전체 구조물의 거동을 지배할 수 있다. 암반설계의 효율을 높이기 위해서는 입자와 연속체 평면의 접촉면 전단거동 메커니즘에 대한 기초적인 이해와 접촉면 전단강도를 정확하게 산정하는 것이 필수적이다. 본 연구에서는 연속체 평면의 표면 거칠기의 영향을 알아보기 위하여 개별요소법 수치해석 프로그램인 $PFC^{2D}$를 사용하였다. 이 때 표면 거칠기는 매끄러운 평면, 중간 거칠기 평면, 거친 평면의 세 가지로 구분하였다. 접촉면 전단시험에서 입자 형상 및 입자 파쇄의 영향을 연구하기 위하여 one ball 모델과 clump 및 cluster 모델을 형성하여 상대적으로 비교 분석하였다. 이 때 입자의 형상은 원형, 삼각형, 직사각형, 정사각형으로 모델링하였다. 수치해석 결과, 표면 거칠기가 클수록 접촉면 전단강도 및 마찰각이 크게 나타났으며, 또한 간극률이 크게 증가하였다. 표면이 매끄러운 one ball 모델보다 작은 입자들의 결합으로 이루어져 표면이 굴곡진 모델, 즉 clump 모델의 접촉면 전단강도 및 마찰각이 크게 나타났다. 입자의 결합이 파괴되는 모델, 즉 cluster 모델의 접촉면 전단 강도 및 마찰각이 같은 형상의 clump 모델보다 작게 나타났으며, 파괴포락선은 비선형으로 나타났다. 이러한 결과로부터 연속체 평면의 거칠기 및 입자의 형상이 입자와 평면의 접촉면 전단거동 특성에 미치는 영향을 확인하였다.

고신뢰성 광모듈을 위한 솔더 범프의 전단강도와 시효 특성 (Shear Strength and Aging Characteristics in Solder Bumps for High Reliability Optical Module)

  • 유정희
    • Journal of Welding and Joining
    • /
    • 제21권2호
    • /
    • pp.97-101
    • /
    • 2003
  • The change of microstructures in the base metal during transient liquid phase bonding process of directionally Ni base superalloy, GID-111 was investigated. Bonds were fabricated using a series of holding times(0~7.2ks) at three different temperatures. The flip chip bonding utilizing self-aligning characteristic of solder becomes mandatory to meet tolerances for the optical device. In this paper, a parametric study of aging condition and pad size of samples was evaluated. A TiW/Cu/electroplated Cu UBM structure was selected and the samples were aging treated to analyze the effect of intermetallic compounds with the time variations. An FIB technique was applied to the preparation of samples for TEM observations. An FIB technique is very useful to prepare TEM thin foil specimens from the solder joint interface. After aging treatment, the tendency to decrease in shear strength was measured and the structure of the solder and the UBM was observed by using SEM, TEM and EDS. As a result, the shear strength was decreased of about 21% in the 100${\mu}{\textrm}{m}$ sample at 17$0^{\circ}C$ aging compared with the maximum shear strength of the sample with the same pad size. In the case of the 12$0^{\circ}C$ aging treatment, 18% of decrease in shear strength was measured at the 100${\mu}{\textrm}{m}$ pad size sample. An intermetallic compound of Cu6Sn5 and Cu3Sn were also observed through the TEM measurement by using.

토목섬유 접촉면의 역학적 특성에 관한 연구 (A study on the mechanical properties of geosynthetic interface)

  • 남용;김광호;임종철;주인곤;권정근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1540-1549
    • /
    • 2009
  • Shear properties of geosynthetic/geosynthetic and geosynthetic/soil were evaluated from direct shear tests. The type of geosynthetic is Velcro which is effective for geosynthetic interface and make up for the weakness of sandbag. In this study, the cohesion and the angle of internal friction of each interface was estimated. The test results showed that the cohesion and the angle of internal friction of the geosynthetics depended on the amount of normal stress, the type of the geosynthetics used, and combinations of the geosynthetics and soils. Finally, by comparing the apparent cohesion and the friction angle of the geosynthetics, the applicability to design was identified.

  • PDF

다이 및 와이어 본딩 공정을 위한 Sn-Sb Backside Metal의 계면 구조 및 전단 강도 분석 (Enhancing Die and Wire Bonding Process Reliability: Microstructure Evolution and Shear Strength Analysis of Sn-Sb Backside Metal)

  • 최여진;백승문;이유나;안성진
    • 한국재료학회지
    • /
    • 제34권3호
    • /
    • pp.170-174
    • /
    • 2024
  • In this study, we report the microstructural evolution and shear strength of an Sn-Sb alloy, used for die attach process as a solder layer of backside metal (BSM). The Sb content in the binary system was less than 1 at%. A chip with the Sn-Sb BSM was attached to a Ag plated Cu lead frame. The microstructure evolution was investigated after die bonding at 330 ℃, die bonding and isothermal heat treatment at 330 ℃ for 5 min and wire bonding at 260 ℃, respectively. At the interface between the chip and lead frame, Ni3Sn4 and Ag3Sn intermetallic compounds (IMCs) layers and pure Sn regions were confirmed after die bonding. When the isothermal heat treatment is conducted, pure Sn regions disappear at the interface because the Sn is consumed to form Ni3Sn4 and Ag3Sn IMCs. After the wire bonding process, the interface is composed of Ni3Sn4, Ag3Sn and (Ag,Cu)3Sn IMCs. The Sn-Sb BSM had a high maximum shear strength of 78.2 MPa, which is higher than the required specification of 6.2 MPa. In addition, it showed good wetting flow.

금전착이 치과용 합금과 전장 레진간의 접착 강도에 미치는 영향 (EFFECT OF GOLD ELECTRODEPOSIT ON THE BOND STRENGTH BETWEEN ALLOYS AND VENEERED RESIN)

  • 양홍서;박영준
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.103-117
    • /
    • 1997
  • The purpose of this experiment was to determind whether the gold electrodeposit on Pd-Ag and Ni-Cr alloys influences on the shear bond strength between veneering resin and silicoated metal surface. All the metal specimens were sandblasted with $250{\mu}m$ aluminum oxide and followed by silicoating and resin veneering. According to the metal surfaces to be veneered, experimental groups were divided into five. Group Prec : Gold alloy without gold coating Group Semi : Pd-Ag alloy without gold coating Group Base : Ni-Cr alloy without gold coating Group Semi-G : Pd-Ag alloy with gold coating Group Base-G : Ni-Cr alloy with gold coating All specimens were thermocycled 1,000 times at temperature of $5^{\circ}C$ to $55^{\circ}C$. The effects of gold electrodeposit on the shear bond strength between resin and metal interface were measured and fractured surface of the resin veneered metal was examined under the scaning electron microscope. The following results were obtained 1. The shear bond strength between resin and metal was $64.51{\pm}11.11Kg/cm^2$ in Prec group, $62.77{\pm}11.23Kg/cm^2$ in Base group and $58.97{\pm}9.20Kg/cm^2$ in Semi Group. There was no significant difference among the groups. 2. The bond strength in groups Semi-G and Base-G decreased about 17%, compared to the nongold-electrodeposit groups(Semi, Base). 3. In groups of non electrodeposit(Prec, Semi, Base), fracture occurred at the interface between alloy and resin, while fracture interface was observed between gold coating and resin in group Semi-G, and between metal substrate and gold coating in group Base-G respectively.

  • PDF

구조용 압연강재와 연청동 합금의 반용융 확산접합 (A Semi-solid Bonding between Rolled Steel for Structural Parts and Lead Bronze Alloy)

  • 김우열;박홍일;이길근;서원찬
    • Journal of Welding and Joining
    • /
    • 제18권1호
    • /
    • pp.70-76
    • /
    • 2000
  • A rolled steel for structural parts and lead bronze alloy were bonded each other by a new semi-solid diffusion bonding process to investigate the effect of the process parameters, for example bonding temperature and bonding time, on the interface characteristics, and bonding behavior. It can be possible that manufacture of the bonded steel/lead bronze which has a cylindrical shape with inserted the lead bronze alloy into the steel ring by the diffusion bonding process under the semi-solid condition of the lead bronze alloy without any pressure and flux. It has been know that the control of the amount of the liquid phase in semi-solid lead bronze alloy was very important to obtain soundness interface, since the shear strength of the bonded steel/lead bronze at 850℃ for 60 minutes under the condition of about 40% of the liquid phase in the lead bronze alloy shows maximum value, 210 MPa. The shear strength increases with an increase in bonding time and show maximum value, and then decreases.

  • PDF

RC자켓팅으로 보강된 기존 벽체의 면외방향 내진성능 실험평가 (Experimental Investigation of Out-of-Plane Seismic Resistance of Existing Walls Strengthened with RC Jacketing)

  • 엄태성;허무원;이상현;이범식;천영수
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.239-248
    • /
    • 2019
  • In this study, the out-of-plane seismic resistance of lightly-reinforced existing walls strengthened with thick RC jacket was investigated. The thick RC jacket with a thickness of 500 mm was placed at one side of the thin existing wall with a thickness of 150 mm. At the interface between the wall and RC jacket, a tee-shaped steel section with a number of anchor bolts and dowel bars was used as the shear connector. To investigate the connection performance and strengthening effects, the cyclic loading tests of four jacketed wall specimens were performed. The tests showed that the flexural strength of the jacketed walls under out-of-plane loading was significantly increased. During the initial behavior, the tee shear connector transferred forces successfully at the interface without slip. However, as the cracking, spalling, and crushing of the concrete increased in the exiting walls, the connection performance at the interface was significantly degraded and, consequently, the strength of the jacketed walls was significantly decreased. The flexural strength of the jacketed walls with tee shear connector was estimated considering the full and partial composite actions of the tee shear connector.

LMC로 보강된 철근콘크리트 보의 파괴거동 (Fracture Behavior of Reinforced Concrete Beams Repaired by Latex-Modified Concrete)

  • 김성환;정원경;김기헌;김동호;윤경구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.475-480
    • /
    • 2003
  • Latex modification of concrete provides the material with higher flexural strength. This increase in flexural strength can attribute to the crack-arresting action of polymer in concrete, and also to the bonding they provide between the matrix and aggregates. This experimental study presents the fracture behavior of 12 flexural reinforced concrete beams repaired or strengthened by latex-modified concrete with the main experimental variables such as overlay thickness, strength thickness, and shear reinforcement. The results are as follow: All beam specimens having shear reinforcement were failed by delamination rupture at concrete interface at about 80% of ultimate loading after flexural cracking. All specimens overlayed and strengthened by latex-modified concrete (LMC) showed higher ultimate flexural strength than OPC control specimen, but lower than LMC control specimen. This increase in flexural strength could attribute to the high bonding they provide between the matrix and aggregates. All specimens except two shear unreinforced showed quite similar and consistent displacement behavior. The effect of overlay and strength thickness on the load-displacement relationship were a small at this study.

  • PDF