• 제목/요약/키워드: Interconnection capacity

검색결과 59건 처리시간 0.037초

동북아시아 연계계통의 신뢰도평가 (Reliability Evaluation for Interconnecting the Power Systems in North East Asia)

  • 최재석;권중지;트란트룽틴;윤재영;박동욱;문승일;차준민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.17-19
    • /
    • 2005
  • This paper illustrates the case studies of reliability evaluation for interconnecting power systems in the north east Asia by using the tie line constrained equivalent assisting generator model(TEAG), which has been already developed in the second project year. A reliability evaluation program, it is named, NEAREL. based on the TEAS model was made. The reliability evaluation results for the seven interconnection scenarios of the actual power systems of six countries in the north east Asia are introduced and compared. The reasonable capacity of the tie line for three countries interconnection senario is suggested from sensitivity analysis.

  • PDF

EMTP를 이용한 ESS가 연계된 배전계통에서 직격뢰 발생 시 계통 및 ESS 측의 서지 해석 (Analysis of Surge in Distribution System and ESS due to Direct Lightning in Distribution System with ESS using EMTP)

  • 서훈철
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.47-53
    • /
    • 2015
  • The study concerning about the grid connection of the large-capacity energy storage system(ESS) is increasing. However, the transient study such as lightning or switching surge necessarily occurred at power system with ESS has been hardly performed. Therefore, this paper performs the analysis of lightning surge in distribution system with ESS using electromagnetic transient program(EMTP). The battery model in Matlab/Simulink is modeled by EMTP, which is the specialized software for power system transient study. Also, the bi-directional power electronics for interconnection of the battery and distribution system are modeled by EMTP. When the lightning is occurred at interconnection point of ESS, this paper simulates the existence of ESS and operation conditions of ESS and analyzes the surge in distribution system and ESS according to the various conditions.

발전기 형태를 고려한 열병합발전시스템의 배전계통 연계운전시의 순시전압변동 해석 (Analysis on Momentary Voltage Dips with the Interconnection Operation of Utility-interactive Cogneration Systems Considering Their Generator Type)

  • 최준호;김재철
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.23-30
    • /
    • 2000
  • 열병합발전 시스템은 환경 친화적인 동시에 상대적으로 고 효율의 에너지 시스템으로서 분산 방전설비의 혁신 기술중 하나이다, 아울러 열병합발전 시스템운 열과 전기의 분산공급에 적절한 발전 시스템이다. 그러나, 열병합발전 시스템의 계통 연계는 전압 소정, 전압변동, 보호협조, 안전등의 제반 연제문제를 수반한다. 특히, 이러한 연계문제 중 열병합발전 시스템의 배전계통 연계.분리 운전은 배전계통의 전압조정 및 변동에 영향을 미칠 것이 예상된다. 최근 수용가 소유의 컴퓨터 및 민감한 전자소자의 사용 증가로 인하여 전력품질온 중요한 고려사항이 되고 있다. 따라서 열병합발전 시스템과 관련한 전압품질은 반드시 분석되어야만 한다. 왜냐하면 전압품질은 전력 품질의 중요한 요소이기 때문이다. 본 논문에서는 열병합발전 시스템의 배전계통 연계 운전에 따른 순서전압변통 에 대하여 컴퓨터 시물레이션을 롱하여 분석하였고、 또한 이의 억제 대책을 제시하였다. 아울러 순시전압변동 측면에서 본 피더 당 열병합발전시스템의 단위 도입 용량을 평가하였다. 본 논문의 결과는 열병합발전 시스템 또는 분산형 전원의 계통 연계 표준. 가이드라인에 유용한 자료가 되리라 믿는다.

  • PDF

국가철도망 구축에 따른 한국철도의 현대화 방안에 관한 연구 (Korean Railway Modernization)

  • 김현웅
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1101-1104
    • /
    • 2005
  • The overall objectives for Korean railway system of the future are speedup, capacity management, increase safety, environmental protection. and enhancement efficiency. To achieve these, interconnection within the railway system must be optimised and designed on a customer-friendly basis. This principles applies to both passenger and freight traffic. for which cost-effective and time-efficient facilities must be provided. As the result. Korean railway network modernization is based on seeking out optimum conditions for improving railway business.

  • PDF

두 종류의 불순물을 가진 광굴절 물질의 체적 홀로그램 광연결에서 생기는 모드간 공간 전하 필드 (Intermode Space Charge Fields in Photorefractive Material with Two Impurities for Volume Holographic Interconnections)

  • 황병준;이혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.666-669
    • /
    • 1993
  • The space charge fields, including intermode apace charge fields in photorefractive material with two impurities are obtained for the small light intensity at large modulation depth, and their implication of high-capacity volume holographic interconnection are presented. In the following data regions the effect of intermode space charge fields are suppresed and the criteria for optimal implementation of volume holographic interconnections are satisfied.

  • PDF

효과적인 웹-캐싱 네트웍 구축전략에 관한 실증 연구 (An Empirical Study on the Construction Strategy of Web-caching Network)

  • 이주헌;조병룡
    • 정보기술과데이타베이스저널
    • /
    • 제8권2호
    • /
    • pp.41-60
    • /
    • 2001
  • Despite the growth in Internet users, demand for multi-medial, large data files and resulting explosive growth in data traffic, there has been lack of investment in Middle-Mile, interconnection of various networks, resulting in bottleneck effect, which is acerbating. One strategy to overcome such network bottleneck is Content Delivery Network (CDN). CDN does not achieve efficient delivery of large file data through physical improvement/increase in network capacity, but by delivering large file contents, the cause of bottlenecks, from distributed servers. Since it is impracticable to physically improve networks capacity to accommodate the growth in internet traffic, CON, by strong CPs contents at cache servers deployed at major ISPs networks, is able to deliver requested contents to the requesting Web clients without the loss of data and long latency.

  • PDF

EMTCD를 이용한 154kV 송전계통에서의 초전도 한류기 적용 해석 (Application Analysis of a Resistive type SFCL for Transmission Systems)

  • 허태전;배형택;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.409-411
    • /
    • 2004
  • The need for Fault Current Limiters (FCL) is associated with the continuous growth and interconnection of modem power systems and increase in dispersed generation facilities, which result in progressive increase in the short circuit capacity far beyond their original design capacity. Fault Current Limiters (FCL) clips the fault currents and reduces the electromechanical stresses on the network and the need to handle excessive fault currents. In addition, the reduction of the fault duration Provided by the limiter should increase the power transmission capability and improve the dynamic stability. This paper proposes the model of resistive type superconducting fault current limiter using EMTDC(Electromagnetic transients for DC analysis program). In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current in a transmission system through the EMTDC based simulation by using the modeled component of a resistive type SFCL is peformed and the detailed results are given.

  • PDF

기존선-고속선 연결선 구간에서 최대부하용량 평가 (Estimation of Maximum Load Capacity at Interconnection Line of High-Speed and Conventional Line)

  • 이장무;이한민;오세찬;김길동;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1069-1070
    • /
    • 2008
  • At the coupling area linking high speed line and conventional line, according to distance between trains due to speed limit of conventional line, the power load of substation supplying to this conventional line increase. At the coupling area between Kimcheon SS and Kyoungsan SS, train operation have problems caused by instantaneous voltage drop. So, this paper propose evaluation method of maximum load capacity at current normal feeding condition.

  • PDF

분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘 (An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations)

  • 신동열;김동명;차한주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

Hybrid 인터커넥션 구현을 위한 광전 복합케이블 제작에 관한 연구 (Study on the Photoelectric Composite Cable for Hybrid Interconnection Implementation)

  • 김재열;유관종;박력
    • 한국기계가공학회지
    • /
    • 제16권3호
    • /
    • pp.138-145
    • /
    • 2017
  • With the increasing use of smart electronic devices, the size of the related I/O interface market is increasing rapidly. Demand is also growing for the continuous increase of data and video signals-such as faster data processing speed and data storage capacity-in the smart electronic device input/output interface market. Currently, the POF hybrid cable used in the smart electronic device input / output interface market cannot transmit over a long distance because the optical loss is too large, and the GOF hybrid cable is both vulnerable to bending and other sudden outside changes, and expensive. Therefore, in this study, the design and fabrication of a GOF hybrid cable and fiber guide were carried out in order to develop a cable which can easily withstand external impact, has low optical losses, and meets the demand for continuous data and video signal increase in the smart electronic device input / output interface market.