• 제목/요약/키워드: Inter-stage pressure

검색결과 15건 처리시간 0.023초

중간 냉각기가 있는 고압 다단 왕복동식 압축기에 관한 열역학적 해석 (Thermodynamic Analysis of High Pressure Multi-stage Reciprocating Compressors with Inter-coolers)

  • 이억수;김명훈;이승홍
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1238-1247
    • /
    • 2003
  • Simplified thermodynamic analysis of high pressure 4-stage reciprocating compressors with 4 inter-coolers has been investigated to predict a behavior of a compressor system for NGV(natural gas vehicles). A computer program has been developed to predict and estimate the performance of high pressure 4-stage reciprocating compressor system. Thermodynamic properties of compressed natural gas(CNG) were calculated by ideal gas theory and compression cycle was assumed as reversible adiabatic compression and expansion processes, and isobaric intake and discharge processes. Comparison between results predicted by calculation model and measured by experimental tests is presented.

의료인을 위한 구강점막욕창 시각적 감별도구의 신뢰도 (Reliability of the Visual Discrimination Scale on Oral Mucosa Pressure Ulcer for Healthcare Providers)

  • 엄주연;김명수
    • 한국융합학회논문지
    • /
    • 제11권11호
    • /
    • pp.443-450
    • /
    • 2020
  • 본 연구는 구강점막욕창의 시각적 감별도구에 대한 신뢰성을 평가하기 위한 연구이다. 연구의 절차는 개발단계와 평가단계로, 개발단계에서는 자료수집, 자문단의 타당도와 신뢰도 평가, 최종도구개발이 수행되었으며, 평가단계에서 대상자들에게 9장의 사진도구를 평가하게 하였다. 세 군에서 측정자 간 신뢰도를 구한 결과, 상처 전문간호사군에서는 Krippendorff's alpha 가 .75이었고, 중환자 전문간호사군에서는 .70이었다. 치과의사군에서의 Cohen's weighted kappa값은 .78 로 나타났다. 측정자 내 신뢰도를 살펴본 결과, 중환자실 일반간호사군들의 intra-rater reliability는 .73으로 나타났다. 신뢰도가 입증된 9장의 사진은 실제 중환자실과 같은 구강점막욕창 위험을 가진 환자를 돌보는 임상환경에서 교육용으로 활용될 수 있을 것으로 보인다.

Effect of Ambient Gas on the Early Stage of the OLED Degradation

  • Kwak, Jeong-Hun;Cho, Hyun-Duck;Hong, Yong-Taek;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1467-1469
    • /
    • 2007
  • We report on the effect of ambient gas on the OLED degradation. The operating voltage and quantum efficiency increases when the device is exposed to the atmospheric gas and then returns to the initial level of the device in vacuum when the atmospheric gas is evacuated. These changes in the OLED performance can be attributed to the ambient gas pressure.

  • PDF

75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험 (Inter Propellant Seal Performance test for 75 ton Class Turbopump)

  • 전성민;곽현덕;박민주;김진한
    • 한국추진공학회지
    • /
    • 제14권5호
    • /
    • pp.57-64
    • /
    • 2010
  • 75톤급 터보펌프용 추진제 혼합 방지 실의 누설 성능 및 내구 성능을 평가하기 위한 수류환경 성능 시험을 수행하였다. 추진제 혼합 방지 실 시제품은 연료펌프 부와 산화제펌프 부 각각 누적 시험 시간 2,100초 동안 수류환경에서 내구 성능 시험이 이루어 졌다. 1단의 카본 플로팅 링 실로 구성된 연료펌프 부는 성능 시험 동안 평균 실 차압 9.4 bar에서 평균 누설 유량 13.7 gram/sec의 결과를 얻었다. 반면, 2단의 카본 플로팅 링 실로 구성된 산화제펌프 부는 성능 시험 동안 평균 실 차압 9.5 bar에서 평균 누설 유량 7.3 gram/sec의 결과를 얻었다. 내구 성능 시험 후, 추진제 혼합 방지 실은 양호한 상태를 보였다. 향후 액체 질소를 시험 매질로 하는 극저온 환경에서 추진제 혼합 방지 실 누설 성능 시험이 수행될 예정이다.

75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험 (Inter Propellant Seal Performance test for 75 ton Class Turbopump)

  • 전성민;곽현덕;박민주;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.47-53
    • /
    • 2010
  • 75톤급 터보펌프용 추진제 혼합 방지 실의 누설 성능 및 내구 성능을 평가하기 위한 수류환경 성능 시험을 수행하였다. 추진제 혼합 방지 실 시제품은 연료펌프 부와 산화제펌프 부 각각 누적 시험시간 2,100초 동안 수류환경에서 내구 성능 시험이 이루어 졌다. 1단의 카본 플로팅 링 실로 구성된 연료펌프 부는 성능 시험 동안 평균 실 차압 9.4 bar에서 평균 누설 유량 13.7 gram/sec의 결과를 얻었다. 반면, 2단의 카본 플로팅 링 실로 구성된 산화제펌프 부는 성능 시험 동안 평균 실 차압 9.5 bar에서 평균 누설 유량 7.3 gram/sec의 결과를 얻었다. 내구 성능 시험 후, 추진제 혼합 방지 실은 양호한 상태를 보였다. 향후 액체 질소를 시험 매질로 하는 극저온 환경에서 추진제 혼합 방지실 누설 성능 시험이 수행될 예정이다.

  • PDF

Staged Finite Element Modeling with Coupled Seepage and Stress Analysis

  • Lee, Jae-Young
    • 한국전산구조공학회논문집
    • /
    • 제23권6호
    • /
    • pp.703-714
    • /
    • 2010
  • This paper proposes an approach for staged finite element modeling with coupled seepage and stress analysis. The stage modeling is based on the predefined inter-relationship between the base model and the unit stage models. A unit stage constitutes a complete finite element model, of which the geometries and attributes are subject to changes from stage to stage. The seepage analysis precedes the mechanical stress analysis at every stage. Division of the wet and dry zone and the pore pressures are evaluated from the seepage analysis and used in determining input data for the stress analysis. The results of the stress analysis may also be associated with the pore water pressures. For consolidation analysis, the pore pressure and the displacement variables are mixed in a coupled matrix equation. The time marching solution produces the dissipation of excess pore pressure and variation of stresses with passage of time. For undrained analysis, the excess pore pressures are computed from the stress increment due to loading applied in the unit stage and are used in revising the hydraulic head. The solution results of a unit stage are inherited and accumulated to the subsequent stages through the relationship of the base model and the individual unit stages. Implementation of the proposed approach is outlined on the basis of the core procedures, and numerical examples are presented for demonstration of its application.

원심압축기 소음측정과 계산에 관한 연구 (An Experimental and Numerical Study on Centrifugal Compressor Noise)

  • 선효성;엄승신;신형기;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.119-124
    • /
    • 2000
  • The 3-stage centrifugal compressor is used in order to measure the noise spectra of compressor, and analyze the results. Two cases are investigated for compressor noise components. Case I includes total system such as compressor, inter-cooler, motor, and Case II excludes cooling system. BPF tonal noise is important in compressor, and cooling system including inter-cooler contributes to broadband noise. Also, motor, gear box, and motor cooling fan are the second contributions to total compressor noise. Centrifugal compressor flow-field is calculated using two-dimensional grid and Navier-Stokes equations. Static pressure increases, and total pressure decreases, as air passes through the compressor components.

  • PDF

저압가스질화에서 탄소강의 초기 화합물층 형성 거동 (Behavior of Initial Formation of Iron Nitride on Carbon Steel at Low Pressure Gas Nitriding)

  • 김윤기;김상권
    • 한국표면공학회지
    • /
    • 제44권3호
    • /
    • pp.75-81
    • /
    • 2011
  • Growth behaviors of iron-nitride on S45C steels at low pressure gas nitriding were examined. Surfaces of the steels covered with fine and porous oxide during the pre-oxidation using $N_2O$ gas. Well faceted particles connected with them were observed after 1 min nitriding. They grew steadily and filled inter-pores during additional nitriding process. From the X-ray diffraction analysis, ${\gamma}'$-iron nitride was dominantly formed at the initial stage but the amount of ${\varepsilon}$-iron nitride was rapidly increased as nitriding treatment time. The porous layer was formed on the particles and thickened up to half of nitride layer after 60 min nitriding. The observed growth behaviors were discussed in internal stress related with volume expansion involved in transforming from iron to iron-nitrides.

간호사의 입원환자 욕창 사정에 대한 정확성 (Accuracy of Nurses' Assessments of Pressure Ulcers in Hospitalized Patients)

  • 권은옥;엄인향;장선주;심미영;이수희
    • 임상간호연구
    • /
    • 제18권1호
    • /
    • pp.29-38
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the accuracy of general nurses' assessments of pressure ulcers in hospitalized patients. Methods: A total of 129 nursing records of assessments on pressure ulcers were analyzed. Assessment records of pressure ulcers by general nurses were compared to those by Wound, Ostomy, Continence Nurses (WOCN) on the same pressure ulcers. A WOCN of a nursing unit was a nurse certified by the hospital after completion of a formal WOCN course and passing a cyber education course, both offered by the hospital. The formal WOCN course was taught by an internationally certified WOCN. The inter-rater reliability among WOCNs was 98.2%. General nurses in this study did not receive a structured pressure ulcer education. Results: The accuracy for nursing assessment of pressure ulcers by general nurses compared to WOCNs' were evaluated in various ways and resulted in as follows; the existence of pressure ulcer 91.4%, site of pressure ulcer 85.3%, stage of pressure ulcer 85.3%, Braden scale 36.3%, size of pressure ulcer 51.9~64.3%, details of pressure ulcer 0~100%. Conclusion: The structured education about pressure ulcer assessment is important to enhance the accuracy of pressure ulcer assessment of hospitalized patients by general nurses.