• 제목/요약/키워드: Inter-laboratory comparison

검색결과 39건 처리시간 0.025초

Inter-laboratory Comparison of Stable Carbon and Nitrogen Isotopic Composition Data Using Elemental Analyzer-isotope Ratio Mass Spectrometers

  • Kim, Jung-Hyun;Kang, Sujin;Bong, Yeon-Sik;Park, Kwangkyu;Kang, Tae-Woo;Park, Yong-Se;Kim, Dahae;Choi, Seunghyun;Joo, Young Ji;Choi, Bohyung;Nam, Seung-Il;Lee, Sang-Mo;Shin, Kyung-Hoon
    • 환경분석과 독성보건
    • /
    • 제21권4호
    • /
    • pp.229-236
    • /
    • 2018
  • In this study, inter-laboratory comparison was done using elemental analyzer-isotope ratio mass spectrometers (EA-IRMSs) to determine carbon and nitrogen contents as well as stable carbon and nitrogen isotopic compositions (${\delta}^{13}C$ and ${\delta}^{15}N$) of five environmental samples containing lake and marine sediments, higher plant leaves, and fish muscle, and one organic analytical standard (Protein (Casein) Standard OAS). Five national laboratories participated in this comparison study, and each laboratory analyzed all five samples and the analytical standard. Results showed that variations in total organic carbon (TOC) and total nitrogen (TN) contents as well as ${\delta}^{13}C_{TOC}$ and ${\delta}^{15}N_{TN}$ values among the laboratories were large compared to the analytical uncertainties. The results highlighted the inhomogeneity of the test samples and thus, the need to select suitable standard reference materials for future inter-laboratory studies. Further inter-laboratory comparison exercises could promote good measurement practices in the acquisition of stable carbon and nitrogen isotopic composition data.

표준백금저항온도계를 이용한 온도측정능력 상호비교 (Inter-comparison of temperature measurement capability using standard platinum resistance thermometers)

  • 감기술;강주식;이용재;이광복;김용규;박승남
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.86-94
    • /
    • 2009
  • Temperature measurement capability was inter-compared using the transfer standard platinum resistance thermometers(SPRT) among four laboratories of KRISS. The transfer SPRTs were primarily calibrated at the triple point of water and Ga melting point, then used at inter-comparison experiment. Temperature difference of calibration value between temperature laboratory and length laboratory at $20^{\circ}C$ was -0.7 mK and +2.4 mK at density laboratory. Temperature measured near $20^{\circ}C$, $25^{\circ}C$ and $30^{\circ}C$ at fluid flow laboratory was deviated by $34.2{\sim}80.4\;mK$ from the calibration values of the transfer SPRT. Ga melting points was inter-compared among three laboratories, and the difference of Ga melting points against the standard Ga melting point of temperature laboratory were $0.03{\sim}0.54\;mK$ at length laboratory and 0.02 mK at density laboratory.

Reference dosimetry for inter-laboratory comparison on retrospective dosimetry techniques in realistic field irradiation experiment using 192Ir

  • Choi, Yoomi;Kim, Hyoungtaek;Kim, Min Chae;Yu, Hyungjoon;Lee, Hyunseok;Lee, Jeong Tae;Lee, Hanjin;Kim, Young-su;Kim, Han Sung;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2599-2605
    • /
    • 2022
  • The Korea Retrospective Dosimetry network (KREDOS) performed an inter-laboratory comparison to confirm the harmonization and reliability of the results of retrospective dosimetry using mobile phone. The mobile phones were exposed to 192Ir while attached to the human phantoms in the field experiment, and the exposure doses read by each laboratory were compared. This paper describes the reference dosimetry performed to present the reference values for inter-comparison and to obtain additional information about the dose distribution. Reference dosimetry included both measurement using LiF:Mg,Cu,Si and calculation via MCNP simulation to allow a comparison of doses obtained with the two different methodologies. When irradiating the phones, LiF elements were attached to the phones and phantoms and irradiated at the same time. The comparison results for the front of the phantoms were in good agreement, with an average relative difference of about 10%, while an average of about 16% relative difference occurred for the back and side of the phantom. The differences were attributed to the different characteristics of the physical and simulated phantoms, such as anatomical structure and constituent materials. Nevertheless, there was about 4% of under-estimation compared to measurements in the overall linear fitting, indicating the calculations were well matched to the measurements.

Damping of Inter-Area Low Frequency Oscillation Using an Adaptive Wide-Area Damping Controller

  • Yao, Wei;Jiang, L.;Fang, Jiakun;Wen, Jinyu;Wang, Shaorong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.27-36
    • /
    • 2014
  • This paper presents an adaptive wide-area damping controller (WADC) based on generalized predictive control (GPC) and model identification for damping the inter-area low frequency oscillations in large-scale inter-connected power system. A recursive least-squares algorithm (RLSA) with a varying forgetting factor is applied to identify online the reduced-order linearlized model which contains dominant inter-area low frequency oscillations. Based on this linearlized model, the generalized predictive control scheme considering control output constraints is employed to obtain the optimal control signal in each sampling interval. Case studies are undertaken on a two-area four-machine power system and the New England 10-machine 39-bus power system, respectively. Simulation results show that the proposed adaptive WADC not only can damp the inter-area oscillations effectively under a wide range of operation conditions and different disturbances, but also has better robustness against to the time delay existing in the remote signals. The comparison studies with the conventional lead-lag WADC are also provided.

철도차량용 디스크 브레이크 라이닝의비교시험 연구 (A Study on Comparison Test of Disk Brake Lining for Rolling Stock (KRRI -CARS))

  • 홍용기;권성태;정종덕;김정남
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.483-488
    • /
    • 2004
  • The inter-laboratory comparison test which is demanded on the authorized test of ISO/IEC 17025 is the program to guarantee the confidence of test result. This paper, as a part of the inter-laboratory comparison test between South Korea and China, is refered to the characteristic of friction coefficient of disk brake lining for rolling stock according to disk type. Brake tests were carried out under constant brake force and operating sequence by using dynamo-tester according to disk and disk lining types. To establishing the confidence of test result, we calculated A type uncertainty about friction coefficient and investigated the factors about the variation of friction coefficient.

  • PDF

제동 라이닝애 대한 시험소간 비교에 의한 숙련도시험 (Proficiency Testing by Inter-Laboratory Comparisons for Braking Lining)

  • 정종덕;권성태;홍용기;김원경
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.586-591
    • /
    • 2003
  • This paper describes the result of proficiency testing by inter-laboratory comparisons for braking lining. Proficiency testing provides an objective means of assessing and demonstrating the validity and reliability of test results produced by laboratories. To more accuracy comparison test for braking lining test, they will be made the same test procedure and environment conditions.

  • PDF

생체시료 중 중금속 및 유기용제 대사물 분석의 실험실간 정도관리 프로그램 (Inter-laboratory Comparison for Analyses of Heavy Metals and Organic Solvent Metabolites in Biological Samples)

  • 양정선;이미영;박인정;강성규
    • 분석과학
    • /
    • 제13권2호
    • /
    • pp.258-267
    • /
    • 2000
  • 1995년부터 실시해 온 산업보건 분야의 '유해물질 및 대사물 분석의 실험실간 정도관리 프로그램'(공식명: 특수건강진단기관 분석정도관리)의 5년간 실시 경과와 결과를 보고하고, 고찰을 통하여 우리나라 산업보건분야 실험실 서비스의 질관리를 위한 앞으로의 방향 등을 제시하고자 한다. 산업현장에서 많이 쓰이는 4가지 혈중 중금속과 5가지 유기용제 대사물에 대하여 연구원에서 제조된 표준시료를 분배하고 결과 분석값과 크로마토그람 등 관련 자료들을 분석하여 참가기관에 대한 분석능력 평가를 실시하였다. 연 2회 실시된 정도관리 결과는 인터넷 등을 통하여 고시하여 산업보건 관련 실험실들의 자율적인 질관리 서비스 경쟁을 유도하고, 관련 실험실 서비스의 사용자인 근로자, 사업주, 산업보건 관련자들의 알 권리를 충족시켜, 실험실의 분석데이타에 대한 객관적인 신뢰도를 확보하고 산업보건 서비스의 질 향상에 크게 기여하였다.

  • PDF

2014년 JCOMM 해수 염분 측정 국제 상호비교실험 결과 보고 (Summary of 2014 JCOMM Pilot Inter-Comparison Project for Seawater Salinity Measurements)

  • 이정한;김은수;이용국
    • Ocean and Polar Research
    • /
    • 제38권3호
    • /
    • pp.247-257
    • /
    • 2016
  • The inter-comparison project for seawater salinity measurements, in which 25 laboratories from 16 countries took part, was conducted by JCOMM (Joint WMO/IOC Technical Commission for Oceanography and Marine Meteorology) for the first time in 2014. Two seawater samples of different salinity values ranging from 30-35 and 20-25 for Sample A and Sample B respectively and which had sufficient homogeneity and stability were distributed to all participants. Participants measured the salinity in their own laboratories at least 3 times and reported the results. Statistical treatments were applied to the results to assess discrepancies among laboratories. 20 out of the 25 laboratories used laboratory salinometers and statistics for this group were denoted as belonging to group ${\alpha}$; while 5 out of the 25 laboratories used hand-held measuring instruments and statistics for this group were denoted as belonging to group ${\beta}$. Bias described as discrepancy among laboratories in group ${\alpha}$ was within ${\pm}0.001$ and expanded uncertainty (k = 2) was in the vicinity of 0.002. The bias and the uncertainty of Korea Institute of Ocean Science and Technology (KIOST), in group ${\alpha}$, were 0.000 and 0.002, respectively. The biases of group ${\beta}$ were greater than group ${\alpha}$ because of constraints related to instrument accuracy. Biases from 3 laboratories in group ${\beta}$ exceed the accuracy specification of the corresponding instruments. Considering that the uncertainty of Standard Seawater (SSW) is of the order 0.001 to 0.002, the inter-comparison results show that 16 laboratories among the 25 laboratories made high quality measurements, largely indistinguishable from one another.

Linear versus Non-linear Interference Cancellation

  • Buehrer, R.Michael;Nicoloso, Steven P.;Gollamudi, Sridhar
    • Journal of Communications and Networks
    • /
    • 제1권2호
    • /
    • pp.118-133
    • /
    • 1999
  • In this paper we compare linear and non-linear inter-ference cancellation for systems employing code division multi-ple access (CDMA) techniques. Specifically, we examine linear and non-linear parallel interference cancellation(also called multi-stage cancellation) in relationship to other multiuser detection al-gorithms. We show the explicit relationship between parallel inter-ference cancellation and the decorrelator (or direct matrix inver-sion). This comparison gives insight into the performance of paral-lel interference cancellation (PIC) and leads to vetter approaches. We also show that non-linear PIC approaches with explicit chan-nel setimation can provide performance improvement over linear PIC, especially when using soft non-linear symbol estimates. The application of interference cancellation to non-linear modulation techniques is also presented along with a discussion on minimum mean-squared error(MMSE) symbol estimation techniques. These are shown to further improve the performance of parallel cancella-tion.

  • PDF

The generation of cloud drift winds and inter comparison with radiosonde data

  • Lee, Yong-Seob;Chung, Hyo-Sang;Ahn, Myeung-Hwan;Park, Eun-Jung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.135-139
    • /
    • 1999
  • Wind velocity is one of the primary variables for describing atmospheric state from GMS-5. And its accurate depiction is essential for operational weather forecasting and for initialization of NWP(Numerical Weather Prediction) models. The aim of this research is to incorporate imagery from other available spectral channels and examine the error characteristics of winds derived from these images. Multi spectral imagery from GMS-5 was used for this purpose and applied to Korean region with together BoM(Bureau of Meteorology). The derivation of wind velocity estimates from low and high resolution visible, split window infrared, and water vapor images, resulted in improvements in the amount and quality of wind data available for forecasting.

  • PDF